NAIS HC4HTM-DC6V, HC4HTM-DC48V, HC4HTM-DC24V, HC4HTM-DC12V, HC4HTM-DC110V Datasheet

...
0 (0)

VDE

1c, 2c, 4c

MINIATURE RELAY

FOR WIDER APPLICATIONS HC-RELAYS

20.8

27.2

20.8

27.2

.819

1.071

.819

1.071

 

 

 

 

 

 

 

 

 

 

35.2

35.2

1.386

1.386

 

 

HCE Amber Relays

mm inch

FEATURES

Extra long life — Min. 10 8 mechanical operations (DC type)

4 contact arrangements

4 Form C (for 5 A 250 V AC),

3 Form C (for 7 A 250 V AC),

2 Form C (for 7 A 250 V AC),

1 Form C (for 10 A 250 V AC)

Applicable to low to high level loads (100 A to 10A)

Amber sealed types available

Bifurcated contact types available as HC4D

SPECIFICATIONS

Contacts

Arrangement

1 Form C

2 Form C

3 Form C

4 Form C

 

 

 

 

 

Initial current resistance, max.

 

30 mΩ

 

(By voltage drop 6 V DC 1 A)

 

 

 

 

 

 

Contact material

Gold-flashed silver alloy

Gold-clad

silver nickel

 

 

 

 

 

 

Nominal

10 A

7 A

7 A

5 A

 

switching capacity

250 V AC

250 V AC

250 V AC

250 V AC

 

Max. switching

2,500 VA

1,750 VA

1,750 VA

1,250 VA

Rating

power

 

 

 

 

(resistive)

Max. switching

 

250 V AC

 

 

voltage

 

 

 

 

 

 

 

 

Max. switching

10 A

7 A

7 A

5 A

 

current

 

 

 

 

 

Coil

Nominal operating power

AC (50Hz): 1.3VA, AC (60Hz): 1.2 VA

DC:0.9 to 1.1W

Remarks

* Specifications will vary with foreign standards certification ratings. *1 Detection current: 10 mA

*2 Excluding contact bounce time

*3 Half-wave pulse of sine wave: 11ms; detection time: 10 s *4 Half-wave pulse of sine wave: 6ms

*5 Detection time: 10 s

*6 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).

Characteristics

Max. operating speed

 

20 cpm (at max. rating)

 

 

 

Initial insulation resistance

 

Min. 1,000 MW at 500 V DC

 

 

 

 

Initial

Between open contacts

700 Vrms for 1 min.

 

 

 

breakdown

Between contact sets

700 Vrms for 1 min.

voltage*1

 

 

 

Between contact and coil

2,000 Vrms for 1 min.

 

 

 

 

 

Operate time*2 (at nominal voltage)

Approx. 10 ms

(at 20°C)

 

 

(DC, AC type)

Release time (without diode)*2

Approx. 5 ms (DC type)

(at nominal voltage) (at 20°C)

Approx. 10 ms (AC type)

Temperature rise, max. (at 70°C)

80°C

(at nominal voltage)

 

 

 

Shock resistance

Functional*3

Min. 196 m/s2 {20 G}

Destructive*4

Min. 980 m/s2 {100 G}

 

 

 

 

Functional*5

10 to 55 Hz at double

 

 

amplitude of 1 mm

Vibration resistance

 

Destructive

10 to 55 Hz at double

 

 

 

 

amplitude of 2 mm

 

 

 

 

 

 

Conditions for operation,

Ambient

–50°C to +70°C

transport and storage*6

temp.

–58°F to +158°F

(Not freezing and condens-

Humidity

5 to 85% R.H.

ing at low temperature)

 

 

Unit weight

 

 

Approx. 30g 1.06 oz

Expected life (min. operations)

Electrical (at 20 cpm)

Voltage

 

125 V AC

250 V AC

 

30 V DC

 

 

 

 

 

 

 

 

 

 

 

Expected life

Load

 

Resistive

Inductive

Resistive

Inductive

Resistive

Inductive

 

(cos ϕ = 1)

(cos ϕ ] 0.4)

(cos ϕ = 1)

(cos ϕ ] 0.4)

 

 

 

 

 

 

 

 

HC1

 

 

10A

5A

10A

3A

 

2×105

 

Current

7A

3A

7A

2.5A

3A

 

1A

5×105

(1 Form C)

 

 

 

 

5A

2A

5A

1.5A

 

1×106

 

 

 

 

HC2

 

 

7A

3.5A

7A

2A

 

2×105

 

Current

5A

2.5A

5A

1.5A

3A

 

0.6A

5×105

(2 Form C)

 

 

 

 

3A

1.5A

3A

1A

 

1×106

 

 

 

 

HC3

 

 

7A

7A

 

1×105

 

Current

3.5A

2A

 

2×105

(3 Form C)

 

 

 

 

5A

5A

3A

 

0.4A

5×105

 

 

 

 

HC4

 

 

5A

2A

5A

1A

 

2×105

 

Current

3A

1A

3A

0.8A

3A

 

0.4A

5×105

(4 Form C)

 

 

 

 

2A

0.5A

2A

0.4A

 

1×106

 

 

 

 

 

 

 

 

 

 

 

Mechanical life (at 180 cpm)

 

 

DC type: 108 , AC type: 5×107

 

 

 

 

 

 

 

 

 

 

 

 

 

 

395

HC

TYPICAL APPLICATIONS

Transportation, power station control

ed machines, amusement devices, medi-

equipment, refrigerators, building control

cal equipment, etc.

equipment, office machines, coin operat-

 

ORDERING INFORMATION

 

 

 

EX. HC

4

 

 

D

 

 

 

 

H

 

 

 

AC 240V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact arrangement

 

Type classifications

 

 

 

 

 

 

 

 

 

 

Terminal arrangement

 

Coil voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: 1 Form C

 

Nil: Standard type

 

 

 

 

 

 

 

 

 

H: Plug-in

 

AC 6, 12, 24, 48, 120/240 V

2: 2 Form C

 

D: Bifurcated contact type

 

 

 

 

 

 

 

 

 

HP: PC board terminal

 

DC 6, 12, 24, 48, 110 V

3: 3 Form C

 

(HC4D only. See Page 400.)

 

 

 

 

HTM: Top mounting

 

 

 

4: 4 Form C

 

K: Latching relay type

 

 

 

 

 

 

 

 

 

HL: Light emitting diode

 

 

 

 

 

 

(HC2K only. See Page 401.)

 

 

 

 

 

wired, plug-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HPL: Light emitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

diode wired, PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.When ordering VDE recognized types, add suffix VDE.

2.HC3 (3 Form C) series are not approved by VDE.

3.AC 48 V type is not available for LED wiring.

4.Standard packing Carton: 20 pcs.; Case: 200 pcs.

5.UL/CSA approved type is standard.

COIL DATA (Common for Standard, Amber sealed and Bifurcated contact types)

DC Type at 20°C 68°F

Coil voltage,

Pick-up voltage,

Drop-out voltage,

 

Max. allowable

Coil resistance,

Nominal coil

Operating power, W

 

voltage,

 

current,

 

 

V DC

V DC (max.)

 

V DC (min.)

 

 

Ω (±10%)

Nominal

Minimum

 

 

V DC

 

mA (±10%)

 

 

 

 

 

 

 

 

 

 

6

4.8

 

0.6

 

6.6

 

 

40

 

150

0.9

0.58

12

9.6

 

1.2

 

13.2

 

160

 

75

0.9

0.58

24

19.2

 

2.4

 

26.4

 

650

 

37

0.9

0.58

48

38.4

 

4.8

 

52.8

 

2,600

 

18.5

0.9

0.58

110

88.0

 

11.0

 

121.0

 

10,000

 

10

1.0

0.64

AC Types (50/60 Hz) at 60 Hz, 20°C 68°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil voltage,

 

Pick-up voltage,

 

Drop-out voltage,

 

Max. allowable

 

Nominal coil

Operating power, VA

 

 

 

 

voltage,

 

current,

 

 

V AC

 

V AC (max.)

 

V AC (min.)

 

 

V AC

 

mA (±20%)

Nominal

Minimum

 

 

 

 

 

 

 

 

 

 

 

6

 

4.8

 

 

1.8

 

 

 

6.6

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

9.6

 

 

3.6

 

 

 

13.2

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

19.2

 

 

7.2

 

 

 

26.4

 

50

1.20

0.77

 

 

 

 

 

 

 

 

 

 

 

 

 

48

 

38.4

 

 

14.4

 

 

 

52.8

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110/120

 

96

 

 

36

 

 

 

132

 

10.9/11.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

220/240

 

176.0

 

 

66.0

 

 

 

264.0

 

6.0/6.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.The range of coil current is ±15% for AC (60 Hz), and ±10% for DC, at 20°C.

2.The relay is applicable to the range of

80% to 110% of the nominal coil voltage. However, it is recommended that the relay be used in the range of 85% to 110% to take temporary voltage variations into consideration.

3.The coil resistance of DC types is the

measured value at a coil temperature of 20°C. Please compensate coil resistance by ±0.4% for each degree centigrade coil temperature change.

4.All AC 240 V types are rated for double coil voltages, both AC 220 V and AC 240 V.

5. For use with 220 V or 240 V DC, connect a resistor as suggested in the chart below, in series with the 110 V DC relay.

Voltage

1 Form C, 2 Form C,

3 Form C, 4 Form C

 

 

 

220 V DC

11 kΩ (5 W)

240 V DC

13 kΩ (5 W)

396

HC

DIMENSIONS (Common for standard, Amber sealed and Bifurcated contact (4C only) types)

Plug-in type

HC1-H (1 Form C)

 

HC2-H (2 Form C)

 

HC3-H (3 Form C)

 

20.8

 

 

20.8

 

 

 

20.8

 

 

 

.819

 

 

.819

 

 

 

.819

 

 

1.7

1.7

27.2

1.7

1.7

 

27.2

1.7

1.7

 

27.2

.067

.067

1.071

.067

.067

 

1.071

.067

.067

 

1.071

 

 

0.6

 

 

0.6

 

 

 

0.6

 

 

 

.024

 

 

.024

 

 

 

.024

 

 

 

35.2

 

 

35.2

 

 

 

35.2

 

 

 

1.386

 

 

1.386

 

 

 

1.386

 

 

 

1

 

 

1

 

 

 

1

 

 

 

.039

 

 

.039

 

 

 

 

 

 

 

 

 

 

 

.039

 

 

 

 

 

 

 

 

 

 

 

 

 

6.4

 

 

6.4

 

 

 

6.4

 

 

2.54

.252

 

2.54

.252

 

 

2.54

.252

 

 

 

 

 

 

 

 

 

 

.100

0.5

 

.100

 

0.5

 

.100

 

0.5

 

13.35

.020

 

13.35

4.41

.020

 

13.35

4.41

.020

 

 

 

.526

.174

 

 

.526

.174

 

4.45

.526

4.41

 

 

 

 

 

 

 

4.06

 

 

 

4.06

 

.175

 

.174

 

 

 

 

 

 

 

 

4.06

 

 

.160

 

 

 

.160

 

 

 

 

 

6.35

 

 

 

6.35

 

 

 

.160

 

 

 

 

 

 

 

 

 

 

.250

 

 

 

.250

 

 

 

6.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.250

 

 

 

 

 

 

 

 

 

 

 

 

 

6.35

 

 

 

6.35

 

 

 

6.35

 

 

.250

 

 

 

.250

 

 

 

 

 

 

 

 

 

 

 

 

 

.250

 

 

 

 

 

 

 

 

mm inch

HC4-H (4 Form C)

 

20.8

 

 

1.7

.819

 

 

1.7

 

27.2

.067

.067

 

1.071

 

 

0.6

 

 

 

.024

 

 

 

35.2

 

 

 

1.386

 

 

 

1

 

 

 

.039

 

 

 

6.4

 

 

2.54

.252

 

 

 

 

 

.100

 

0.5

4.45

13.35

4.41

.020

.526

.174

 

.175

 

 

 

4.06

.160

6.35

.250

6.35

.250

General tolerance: ±0.2 ±.008

PC board type

HC4-H (4 Form C)

 

20.8

 

 

1.7

.819

 

 

1.7

 

27.2

.067

.067

 

1.071

 

 

0.6

 

 

 

.024

 

 

 

35.2

 

 

 

1.386

 

 

 

1

 

 

 

.039

 

 

 

1.5

 

 

 

.059

 

 

1.5

3.5

 

 

.059

0.5

 

.138

 

13.35

 

.020

 

4.41

 

4.45

.526

 

.174

 

.175

 

 

 

4.06

.160

6.35

.250

6.35

.250

General tolerance: ±0.2 ±.008

Dimensions of HC1-HP, HC2-HP, HC3-HP are the same as those of plug-in type except shapes of terminals.

PC board pattern (Copper-side view)

1c

2c

 

4.1

 

4.1

.161

 

.161

 

 

16.8

 

 

.661

 

 

10.4

4.45

 

.409

 

8-2 dia.

.175

13.35

8

8-.079 dia.

.350

.526

 

3c

 

4c

 

 

4.1

 

4.1

 

.161

 

.161

 

10.4

 

 

 

.409

 

16.8

 

16.8

 

.661

 

.661

 

10.4

13.35

11-2 dia.

4.45

.409

 

.526

11-.079 dia.

.175

14-2 dia.

 

8.9

 

 

14-.079 dia.

 

 

.350 13.35

 

 

.526

 

Tolerance: ±0.1 ±.004

Note: Special PC terminal with 0.9 mm (.035 inch) width available with suffix "-31".

Schematic (bottom view)

 

 

 

 

 

 

 

 

 

 

 

 

HC1-H, HC1-HP (1 Form C)

HC2-H, HC2-HP (2 Form C)

HC3-H, HC3-HP (3 Form C)

HC4-H, HC4-HP (4 Form C)

2

 

 

1

4

 

1

2

3

1

2

3

4

7

12

 

5

8

 

4

5

6

5

6

7

8

 

 

 

9

12

 

7

8

9

 

 

 

 

13

14

 

13

14

 

 

 

 

 

9

10

11

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

14

 

 

 

 

 

 

13

 

13

 

 

LED AC type

 

LED AC type

 

LED AC type

 

LED AC type

2

 

1

 

4

 

1

 

2

3

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

7

12

5

 

8

 

4

 

5

6

5

6

7

8

 

9

 

12

 

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

13

14

13

 

14

13

 

 

 

9

10

11

12

( )

( )

 

 

 

14

13

 

 

 

 

( )

 

 

( )

 

)

 

 

( )

 

 

14

 

 

 

 

 

(

 

 

( )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

( )

LED DC type

 

LED DC type

 

LED DC type

 

LED DC type

2

 

1

 

4

 

1

2

3

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

7

12

5

 

8

 

4

5

6

5

6

7

8

 

9

 

12

 

7

8

9

 

 

 

 

 

 

 

 

 

 

 

 

13

14

13

()

14

13

 

 

 

9

10

11

12

()

 

 

 

14

13

 

 

 

 

(+)

 

 

(+)

 

)

 

()

 

 

14

 

 

 

 

 

 

(

 

(+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(+)

397

NAIS HC4HTM-DC6V, HC4HTM-DC48V, HC4HTM-DC24V, HC4HTM-DC12V, HC4HTM-DC110V Datasheet

HC

REFERENCE DATA

1. Life curve

2. Switching capacity range

3. H2S gas test

Load: 250 V AC resistive load

10,000

Mechanical life (DC type)

 

 

 

 

 

 

 

 

5,000

 

 

 

 

 

resistanceContact

100Ω

10Life,×

 

 

 

 

 

Vvoltage,AC

 

HC2c, 3c

times

Mechanical life (AC type)

 

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

100

 

 

 

 

10Ω

 

 

 

 

 

 

 

 

 

HC4c

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

400

 

1c

(250 V AC cosϕ = 1)

10

 

 

 

 

 

 

300

 

 

HC1c

 

 

100mΩ

 

 

2c

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

3c

 

 

 

 

 

 

 

 

 

10mΩ

 

100

 

 

 

 

 

 

 

 

 

 

4c

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110

 

 

2

4

6

8

10

1mA

10mA

1A

5A 10A

 

 

 

 

 

 

 

 

 

 

AC current

7A

 

 

 

 

 

 

Load current, A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard HC relay

Gas density:

2 to 5 ppm Temperature: 40°C Humidity: 90% RH

HCE Amber relay

20 50 100 200 500 1000 2000 5000

Exposure time, Hrs.

4. Coil temperature rise

Measured portion: Inside the coil Note: When the nominal voltage is applied to AC 120 or 240 V coil types respectively, the figures of coil temperature rise increase by approx. 10 degrees to the ones shown on each graph.

HC1 AC coil

Ambient temperature: 25°C 77°F

 

 

 

100

 

 

 

 

 

°C

90

 

 

 

 

 

80

 

 

 

 

10A

rise,

 

 

 

 

70

 

 

 

 

7A

Temperature

 

 

 

 

 

 

 

 

 

5A

60

 

 

 

 

2A

 

 

 

 

 

0A

50

 

 

 

 

 

40

 

 

 

 

 

 

30

 

 

 

 

 

 

20

 

 

 

 

 

 

10

 

 

 

 

 

 

0

80

90

100

110

120

 

 

Coil applied voltage, %V

HC2 AC coil

Ambient temperature: 30°C 86°F

 

 

 

100

 

 

 

 

 

 

90

 

 

 

 

7A

°C

80

 

 

 

 

 

rise,

 

 

 

 

 

70

 

 

 

 

5A

Temperature

60

 

 

 

 

0A

 

 

 

 

 

50

 

 

 

 

 

40

 

 

 

 

 

 

30

 

 

 

 

 

 

20

 

 

 

 

 

 

10

 

 

 

 

 

 

0

80

90

100

110

120

 

 

Coil applied voltage, %V

HC3 AC coil

Ambient temperature: 18°C 64°F

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7A

 

 

90

 

 

 

 

 

 

 

 

 

 

 

°C

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

rise,

 

 

 

 

 

 

 

 

 

 

 

5A

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0A

40

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

90

100

110

120

 

 

 

Coil applied voltage, %V

HC2 DC coil

Ambient temperature: 29°C 84°F

 

 

 

100

 

 

 

 

 

 

90

 

 

 

 

 

°C

80

 

 

 

 

 

rise,

 

 

 

 

 

70

 

 

 

 

7A

 

 

 

 

 

Temperature

 

 

 

 

 

60

 

 

 

 

5A

50

 

 

 

 

 

 

 

 

0A

40

 

 

 

 

 

 

30

 

 

 

 

 

 

20

 

 

 

 

 

 

10

 

 

 

 

 

 

0

80

90

100

110

120

 

 

 

 

 

Coil applied voltage, %V

HC4 AC coil

HC1 DC coil

Ambient temperature: 15 to 21°C 59 to 70°F

Ambient temperature: 29°C 84°F

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

°C

180

 

 

 

 

 

°C

90

 

 

 

 

 

160

 

 

 

 

 

80

 

 

 

 

 

rise,

 

 

 

 

 

rise,

 

 

 

 

 

140

 

 

 

 

 

70

 

 

 

 

 

Temperature

 

 

 

 

 

Temperature

 

 

 

 

 

120

 

 

 

 

5A

60

 

 

 

 

10A

 

100

 

 

 

 

3A

 

50

 

 

 

 

5A

 

 

 

 

 

 

 

 

 

 

0A

 

80

 

 

 

 

1A

 

40

 

 

 

 

 

 

60

 

 

 

 

 

 

30

 

 

 

 

 

 

40

 

 

 

 

 

 

20

 

 

 

 

 

 

20

 

 

 

 

 

 

10

 

 

 

 

 

 

0

80

90

100

110

120

 

0

80

90

100

110

120

 

 

 

 

 

 

 

Coil applied voltage, %V

 

 

 

Coil applied voltage, %V

HC3 DC coil

HC4 DC coil

Ambient temperature: 29°C 84°F

 

 

Ambient temperature: 17 to 18°C 62 to 64°F

 

100

 

 

 

 

 

 

100

 

 

 

 

 

Temperaturerise, °C

90

 

 

 

 

 

 

90

 

 

 

 

 

80

 

 

 

 

 

Temperaturerise, °C

80

 

 

 

 

5A

40

 

 

 

 

7A

40

 

 

 

 

 

70

 

 

 

 

 

 

70

 

 

 

 

 

 

60

 

 

 

 

5A

 

60

 

 

 

 

3A

 

50

 

 

 

 

0A

 

50

 

 

 

 

1A

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

30

 

 

 

 

 

 

20

 

 

 

 

 

 

20

 

 

 

 

 

 

10

 

 

 

 

 

 

10

 

 

 

 

 

 

0

80

90

100

110

120

 

0

80

90

100

110

120

 

 

 

 

 

 

 

Coil applied voltage, %V

 

 

 

 

Coil applied voltage, %V

398