NAIS CA1bS-12V-N-5, CA1bS-12V-C-5, CA1bS-12V-A-5, CA1bFS-12V-N-5, CA1bFS-12V-C-5 Datasheet

...
0 (0)
NAIS CA1bS-12V-N-5, CA1bS-12V-C-5, CA1bS-12V-A-5, CA1bFS-12V-N-5, CA1bFS-12V-C-5 Datasheet

AUTOMOTIVE POWER

RELAYS — SMALL SIZE, CA-RELAYS

LIGHT WEIGHT AND COMPLETELY WATER TIGHT

FEATURES

1. Small size and light weight

For space saving, the outside dimensions of the main body are reduced to be 21.5 mm (length) × 14.4 mm (width) × 37 mm (height) (.846 × .567 × 1.457 inch). and the weight is also reduced to be approx. 19 g .67 oz (Direct coupling 1 Form A,

1 Form B type)

2. Water tightness

Since the relays comply with the water tightness standards, JIS D 0203, water and dust will not enter the relay even if it is mounted in the engine area.

3.Low operaing power (1.4W) type is available (1 Form A, 1 Form B)

4.Since the terminal arrangement complies with JIS D5011 B4-M1, commercial connectors are available for these types of relays.

SPECIFICATIONS

Contact

Type

 

 

 

 

 

12 V DC

 

 

24 V DC

 

 

 

 

 

 

 

 

 

 

Arrangement

 

 

1 Form A

 

 

1 Form B

1 Form C

 

1 Form C

 

 

 

 

 

 

 

 

Initial contact resistance, max.

 

 

 

50 m ohm

 

 

(By voltage drop 6 V DC 1A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact material

 

 

 

silver alloy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3 V

 

 

 

 

 

 

 

 

 

 

After electrical life test,

 

0.3 V

0.4 V

 

0.4 V

 

 

 

 

by voltage drop

 

 

 

 

 

 

 

 

After electrical life test,

After electrical life test,

After electrical life test,

Contact voltage drop, max.

12 V DC 20 A

 

 

 

by voltage drop

by voltage drop

 

by voltage drop

 

 

 

 

(1.4 W type),

 

 

 

 

 

 

 

 

 

12 V DC 20 A

12 V DC 20 A

 

24 V DC 10 A

 

 

 

 

12 V DC 30 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1.8 W type)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 A 12 V DC

 

 

 

 

 

 

 

 

Nominal switching capacity

(1.4 W type)

 

 

20 A 12 V DC

 

10 A 24 V DC

 

 

(resistive load)

30 A 12 V DC

 

 

 

(ON: 2s, OFF: 2s)

 

 

 

 

 

 

 

 

 

 

 

(1.8 W type)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. switching voltage

 

16 V

 

15 V

 

30 V

Rating

 

 

 

 

 

 

 

 

 

 

 

Max. switching current

120 A (1.4 W type)

 

 

120 A

100 A

 

50 A (Inrush current)

 

 

150 A (1.8 W type)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 A continuous

 

 

 

 

 

 

 

 

Max. carrying current

(1.4 W type)

 

 

20 A continuous

20 A continuous

 

10 A continuous

 

 

30 A for 1 min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1.8 W type)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal operating power

1.4 W / 1.8 W

 

1.8 W

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical (at 120 cpm)

 

106

 

 

5×105

Expected

 

 

20 A

105

 

 

 

 

 

 

life (min.

 

Electrical

(1.4 W, 1.8 W type)

(ON: 2s, OFF: 2s)

 

 

105 (ON 2s, OFF 2s)

 

105

operations)

 

 

 

 

 

 

 

30 A

2×104

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1.8 W type)

(ON: 3s, OFF: 15s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

383

CA

Characteristics (at 20°C 68°F )

Type

 

 

 

 

 

 

 

12 V DC

 

24 V DC

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. operating speed

 

 

 

15 cpm

(

1.4 W type: at nominal load

)

 

15 cpm (at nominal load)

 

 

 

 

1.8 W type: at 20 A

 

 

Initial insulation resistance

 

 

 

 

 

 

 

Min. 10 Ω at 500 V DC

 

Initial breakdown

Between open contacts

 

 

 

 

 

500 V rms for 1 min.

 

voltage*1

Between contacts and coil

 

 

 

 

 

500 V rms for 1 min.

 

Operate time*2 (at nominal voltage)

 

 

 

 

Max. 10 ms at 20°C

 

Max. 10 ms

Release time (without diode)*2

 

 

 

 

 

 

Max. 10 ms at 20°C

 

Max. 10 ms

(at nominal voltage)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shock resistance

 

 

Functional

 

 

 

Min. 200 m/s2 {20 G}

 

 

Min. 100 m/s2 {10 G}

Min. 100 m/s2 {10 G}*3

 

 

Destructive*4

 

 

 

 

 

Min. 1,000 m/s2 {100 G}

 

 

 

 

 

 

 

 

 

 

 

 

 

Functional*5

Rubber bracket A type: Min. 100 m/s2 {10 G}, 50 to 500Hz

 

Min. 44.1 m/s2 {4.5 G},

 

 

 

Direct coupling type or Screw-mounting type: Min. 44.1 m/s2 {4.5 G}, 10 to 100 Hz

10 to 100Hz

Vibration resistance

 

 

 

Destructive

Rubber bracket A type: Min. 100m/s2 {10 G},50 to 500Hz

 

Min. 44.1 m/s2 {4.5 G},

 

 

 

 

 

 

 

Direct coupling type or Screw-mounting type: Min. 44.1 m/s2 {4.5 G}, 10 to 100 Hz

10 to 500Hz

 

 

 

 

Conditions for operation,

 

Ambient

 

 

 

 

–30°C to +80°C –22°F to +176°F

 

transport and storage*6

 

temp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Not freezing and condensing

 

Humidity

 

 

 

 

 

 

5 to 85% R.H.

 

 

low temperature)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water-proof standard

 

 

 

Plastic sealed type: JIS DO203S2, Dust cover type: JIS DO203R2

JIS DO203S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rubber bracket A type : 23 g .81 oz

 

 

 

 

 

Unit weight

 

 

 

Direct coupling type or Screw-mounting type:

 

31 g 1.09 oz

 

 

 

 

19 g .67 oz

 

 

 

 

 

 

 

 

Electrical life (min. operation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal coil voltage, V DC

 

Motor load

Halogen lamp load

 

 

 

 

(operating frequency ON: 2 s, OFF: 2 s)

(operating frequency ON: 1 s, OFF: 14 s)

 

 

 

 

 

 

 

 

1 Form A, 1 Form B

 

 

12

 

 

 

105, 20 A 12 V DC

105, 20 A 12 V DC

1 Form C

 

 

 

12

 

 

 

105, 20 A 12 V DC

105, 20 A 12 V DC

 

 

 

24

 

 

 

105, 10 A 24 V DC

105, 6 A 24 V DC

 

 

 

 

 

 

 

Remarks

* Specifications will vary with foreign standards certification ratings. *1 Detection current: 10 mA

*2 Excluding contact bounce time

*3 Half-wave pulse of sine wave: 11ms; detection time: 10 s

*4 Half-wave pulse of sine wave: 6ms *5 Detection time: 10 s

*6 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61)

ORDERING INFORMATION

 

 

 

 

 

 

CA

 

1a

 

 

F

 

 

S

 

 

 

 

12 V

 

 

 

 

 

A

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact

 

Protective construction

 

 

Nominal operating power

 

Coil voltage

 

 

 

Mounting method

 

Classification by type

arrangement

 

 

 

 

(DC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1a: 1 Form A

Nil: Plastic sealed type

Nil: Standard type (1.8 W)

12 V

 

A: Rubber bracket A type

 

Nil: 1 Form C

1b: 1 Form B

F: Dust cover type

 

 

 

S: Low operating power type (1.4 W)

24 V (1 Form C only)

A: (1 Form A, 1 Form B)

 

5: 1 Form A or

1 : 1 Form C

 

 

 

 

 

 

 

 

 

(1 Form A, 1 Form B)

 

 

 

 

 

 

 

 

 

 

 

N: Screw mounting type

 

1 Form B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C: Direct coupling type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: 1. Type with resistor/diode inside are available as options. Please consulf our sales office.

 

 

 

 

 

 

 

 

 

 

 

2. Standard packing: Carton: 20 pcs. Case: 200 pcs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Standard type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal

Pick-up voltage,

 

 

 

Drop-out

 

 

Nominal oper-

Coil resistance,

 

 

Nominal

Usable

 

 

 

Plastic sealed

 

 

 

 

 

 

 

voltage, V DC

 

 

ating current,

 

 

operating

voltage

 

Mounting type

Dust cover type

voltage,

 

 

V DC (max.)

 

 

 

Ω (±10%)

 

 

arrangement

 

 

type

 

 

 

 

 

 

 

 

(min.)

 

 

mA (±10%)

 

 

 

power, mW

range, V

 

 

 

 

 

 

 

 

 

 

 

 

 

V DC

 

(at 20°C 68°F)

 

 

 

 

(at 20°C 68°F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(at 20°C 68°F)

 

 

(at 20°C 68°F)

 

(at 20°C 68°F)

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rabber bracket A

CA1a-12V-A-5

CA1aF-12V-A-5

12

8

 

 

 

 

 

 

0.6 to 6

 

 

150

80

 

1.8

 

10 to 16

1 Form A

 

Screw-mounting

CA1a-12V-N-5

CA1aF-12V-N-5

12

8

 

 

 

 

 

 

0.6 to 6

 

 

150

80

 

1.8

 

10 to 16

 

 

 

Direct coupling

CA1a-12V-C-5

CA1aF-12V-C-5

12

8

 

 

 

 

 

 

0.6 to 6

 

 

150

80

 

1.8

 

10 to 16

 

 

 

Rabber bracket A

CA1b-12V-A-5

CA1bF-12V-A-5

12

8

 

 

 

 

 

 

0.6 to 6

 

 

150

80

 

1.8

 

10 to 16

1 Form B

 

Screw-mounting

CA1b-12V-N-5

CA1bF-12V-N-5

12

8

 

 

 

 

 

 

0.6 to 6

 

 

150

80

 

1.8

 

10 to 16

 

 

 

Direct coupling

CA1b-12V-C-5

CA1bF-12V-C-5

12

8

 

 

 

 

 

 

0.6 to 6

 

 

150

80

 

1.8

 

10 to 16

 

 

 

Screw-mounting

CA1-DC12V-N

 

 

12

8

 

 

 

 

0.6

 

 

 

 

 

150

80

 

1.8

 

10 to 15

1 Form C

 

Direct coupling

CA1-DC12V-C

 

 

12

8

 

 

 

 

0.6

 

 

 

 

 

150

80

 

1.8

 

10 to 15

 

Screw-mounting

CA1-DC24V-N

 

 

24

16

 

 

 

 

1.2

 

 

 

 

 

75

 

320

 

1.8

 

20 to 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct coupling

CA1-DC24V-C

 

 

24

16

 

 

 

 

1.2

 

 

 

 

 

75

 

320

 

1.8

 

20 to 30

384