Moen 8700, 7300 User Manual

0 (0)
7300, 8700 SERIES
MT170
®
INSTALLATION INSTRUCTIONS
THESE INSTRUCTIONS MUST BE
LEFT WITH HOMEOWNER
KITCHEN DECK FAUCETS
Single-Handle - for Eight-Inch Centers
Measurements
7-1/2" (191mm)
OPEN POSITION
NOMINAL
2-1/8"
(54mm)
1/2" STRAIGHT
PIPE THREAD
MOUNTING
NUT/WASHER
TAILPIECE NUT
FOR 8" (203mm) CENTERS
DECK ESCUTCHEON
10" (254mm) X 2" (51mm) WIDE
(DECK GASKET IS ONLY
USED WITH DECORATOR MODELS)
9" (229mm)
SPOUT
5-3/8" (137mm)
NOMINAL
(9" SPOUT)
7-1/8" (181mm)
NOMINAL
(12" SPOUT)
DECK
GASKET
"FLOW-RATOR"
AERATOR
Complies with ASME A112.18.1M and CSA B125
Equipped with Flow-Rator® Aerator or Swing-N-Spray Aerator
Always turn water off before disassembling the valve. Open valve
CAUTION:
Before turning water on during either rough-in or trim-out, make sure that cartridge retainer clip is in place. The cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed. This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure could force the cartridge out of the casting. Personal injury or water damage to the premises could result.
handle to relieve water pressure and insure that complete water shut­off has been accomplished.
EAR
Installation
TO INSTALL FAUCET: Be sure sink or mounting surface is clean and dry. Place deck gasket on bottom of faucet and insert faucet supplies down through deck holes. Center deck gasket and faucet on sink. Tighten mounting nuts from below deck. Carefully trim excess deck gasket. Make connections to your hot and cold water supplies.
TO INSTALL HOSE AND SPRAY: Place a bead of plumber's putty under the rim of the spray escutcheon. Install spray head escutcheon and tighten locknut by hand, from below the deck. Feed spray hose down through spray head escutcheon, apply tape to the spray hose nipple and screw into faucet.
Flushing
IMPORTANT:
Pipe chips, sand, stones, and other solids found in new and renovated plumbing can damage the sealing surface of the cartridge and cause a leak. To avoid damage, DO NOT OPERATE THE VALVE until you have followed these instructions:
1. After installing and connecting the faucet turn the valve on in the full cold position (handle pointing to the right) and turn on the cold supply for 15 seconds.
2. Without closing the valve turn to the full hot position (handle pointing to the left) and turn on the hot supply for 15 seconds.
3. Close the valve, unscrew aerator from the end of the spout and clean the cone screen.
4. Replace aerator.
5. Check the system for leaks.
Maintenance
Your new Moen faucet will give good service for an extended period of time. Should foreign materials in the system affect its operation, routine repairs can be easily made.
If your faucet drips from the spout end or leaks up through the handle, follow "Disassembly" instructions and replace the cartridge. If your faucet leaks from either the top or bottom of the spout hub, replace o-rings. Be sure to use only genuine Moen replacement parts. Re-assemble, following "Reassembly" instructions. For proper water flow, aerator must be free of foreign particles. If flow is weak or irregular, unscrew aerator, clean and replace.