Moen 12341, 12242, TL182, 12342, 12189 User Manual

...
0 (0)
Moen 12341, 12242, TL182, 12342, 12189 User Manual

T187, T188, T189, T190, T191, T628, 2320, 2325, 2339, 2370, 2375, 2389 Series

MT692C

Models 12189, 12242, 12341, 12342, 62300, TL181, TL182, TL183, TL191

 

INSTALLATION INSTRUCTIONS

THESE INSTRUCTIONS MUST BE

LEFT WITH HOMEOWNER

POSI-TEMP

TUB AND SHOWER VALVES

Available with and without stops.

Connections are either 1/2 inch I.P.S. pipe or 1/2 inch copper sweat connections.

If the Moen Slip Fit spout is used, a 1/2 inch copper drop and lookout may be used.

Measurements

These are shown in the drawings. The depth measurement is critical. Use the front face of the plaster ground as a reference point for the finished wall position, including tile ( 1-3/4"[44mm] ). The supply piping centerline should be a maxium of 2" (51mm) and a minimum of 1" (25mm) behind the wall surface. Use thick wall handle extension kit 96945 for wall thickness 13/16" to 1-13/16". Use handle kit 96955 for wall thickness 1-13/16" to 2-13/16".

 

 

 

 

 

 

WALL LINE

 

 

 

 

 

 

 

 

 

IMPORTANT: SEE FLUSHING INSTRUC-

 

 

 

 

 

 

FACE OF STUD

TIONS PAGE 2

 

 

 

 

 

FINISHED WALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SURFACE

 

 

 

 

 

KNOB CAP

KNOB

KNOB

 

 

 

 

 

A

 

SCREW

HANDLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STOP

1-3/4" (44mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

ESCUTCHEON

TUBE

 

 

 

 

 

HANDLE

WASHER

TEMPERATURE

 

2-5/16" (59mm) MAX (IPS)

 

 

 

SCREW

 

LIMIT STOP

 

2-3/16" (56mm) MAX (CC)

6'6"

B

 

 

 

 

 

 

 

(1981mm)

PLUG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUTTON

 

 

 

 

 

 

 

 

 

 

 

KEY STOP

 

 

 

 

 

 

 

HANDLE

 

 

 

 

 

 

LEVER

 

ADAPTER

 

 

 

 

 

 

 

 

PLASTER GROUND

SHOWER 45" (1143mm) to 48" (1219mm)

 

HANDLE

 

 

 

 

 

 

 

32" (813mm) FOR TUB/SHOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMBINATIONS AND TUB

 

 

 

 

 

 

 

 

MODELS ONLY

 

C

 

 

 

TUB SPOUT

 

 

 

 

 

 

 

HANDLE

 

 

 

 

 

 

 

 

SCREW

 

 

 

 

 

 

 

CAP

 

FLOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCREW

 

 

 

 

 

 

 

 

HANDLE ASSEMBLIES

 

 

 

 

 

CAUTION:

Always turn water off before disassembling the valve. Open valve handle to relieve water

pressure and to insure that complete water shut-off has been accomplished.

Before turning water

on during either rough-in or trim-out, make sure that cartridge retainer clip is in place.

The cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed. This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure could force the cartridge out of the casting. Personal injury or water damage to the premises could result.

RETAINER

CLIP

Visit Moen's Web Site at www.moen.com

Stop Operation

WITH STOPS

WITHOUT STOPS

CC - This type is integral with casting, actuated by screwdriver, and require a 90° turn to open or close. When the screwdriver slot is vertical, the rubber stop is closed, and when the slot is horizontal, the rubber stop is open.

IPS - This type has been added to the basic shower casting and is actuated by a screwdriver. The stop is opened by rotating in a counterclockwise direction until it stops and closed by rotating in a clockwise direction until it bottoms.

Rough-In

MAKE SURE ALL WATER SUPPLIES ARE OFF.

7"

7"

SHOWER

SHOWER

 

 

SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

TUB

 

 

 

 

 

TUB

 

 

 

 

 

 

 

 

 

 

 

2-5/16" C.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

& I.P.S.

4-1/2"

2-3/4" C.C.

 

 

 

 

 

 

 

 

 

 

 

& I.P.S.

 

 

 

 

 

 

PLASTER

 

 

 

 

 

 

 

4-13/16" C.C.

 

GROUND

 

 

 

 

 

 

SIZE AND

 

 

 

 

 

4-5/16"

 

 

 

 

 

 

 

 

 

 

 

WALL

 

 

 

 

 

NOMINAL

 

 

 

 

 

 

 

OPENING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note the word "TOP" on the casting. Install casting with the TOP facing UP. If the valve is to be

SUPPLY

 

used for a shower only, plug the bottom outlet. If the valve is to be used for both a shower and

 

a tub, connect the top outlet to the shower and the bottom outlet to the tub. Secure all pipes

 

and the shower and tub drop ells. Use thread seal tape on all threads.

 

Flushing

IMPORTANT: Before closing all wall openings, pressure test valve and complete system using flushing instructions

Pipe chips, sand and other solids found in new and renovated plumbing can damage the sealing surfaces of the cartridge causing a leak or cause the spool to become blocked. To avoid damage, DO NOT

TURN ON SUPPLY VALVES until instructed below.

Make sure both hot and cold supplies are off. Rotate the cartridge stem until the notched flat points up to relieve pressure and insure complete shut-off. Remove the cartridge assembly (see "Disassembly").

Slowly turn on both hot and cold supplies and thoroughly flush out the body and lines. Close the hot and

cold supplies and replace the cartridge assembly (see "Reassembly"), turn on both supplies and check the system for leaks.

If the balancing spool becomes stuck, it will be apparent at the trim-out test in that the valve will deliver only a small trickle of water, or it will deliver only hot or cold water. If this occurs, proceed as follows:

Make sure that both the hot and cold water service lines are "ON". Also make sure that both rubber stop valves are open (stop models). The valve WILL NOT OPERATE unless both supplies are "ON".

If the valve still does not function properly, turn off BOTH the hot and cold supplies and remove the cartridge assembly. A cartridge twisting tool is required for this. The inner spool in the cartridge assembly should shake back and forth freely. If this does not happen, remove the stem assembly from the cartridge sleeve, remove the cap from the stem assembly and remove the balance spool. Sometimes the stem assembly may have to be jarred to free the spool. Carefully clean any foreign material from the balance spool and stem assembly and reassemble (see illustration). CAUTION: DO NOT DAMAGE O-RINGS. The spool should move back and forth after the stem assembly is cleaned. If spool still does not free up, replace the entire cartridge assembly.

SUPPLY

CAUTION

This valve is equipped with the Moen long-life POSI-TEMP cartridge, designed for smooth, trouble-free operation. When soldering do not heat valve any higher than necessary to flow the solder. Overheating may damage the cartridge or rubber stop valves. Following this direction will allow you to solder without removing the cartridge or rubber stop valves.

WARNING: The cartridge and rubber stop valves MUST be removed before either brazing or resistance (electric) soldering.

CLIP/BARS

ORIENT THE CLIP IN THE SPOOL AND THE CAP FINGERS AS SHOWN ABOVE.

Make sure O-rings are free of foreign material and are lubricated. Re-assemble stem assembly into cartridge sleeve. Re-assemble cartridge into valve. (See "Reassembly"). Turn both water supplies on. The valve should function properly.

Slip-Fit spouts

C.C. SPOUT: The Moen Slip Fit spout is designed with an O-ring seal. It is specifically designed for installation with copper water tube. Lookout must be free from burrs inside and out. The edge must not be rolled inward from a dull tubing cutter. The outside surface must be free from nicks and scratches.

O-RINGS

STEM ASSEMBLY

CAP

BALANCE CLIP/BARS

SPOOL

Press and twist the spout onto the lookout upside down. Tighten the clamp screw with a 5/32" hex wrench until it just starts to bind. Turn spout upright into position against the wall and finish tightening the clamp screw by hand. The use of pliers or another wrench on the hex wrench is not necessary. Do not overtighten.

C.C. I.P.S.

CLAMP

SCREW

IPS SPOUT:

CAUTION: This spout is A.B.S. plastic and will crack when in contact with some pipe thread compounds.

Please read the pipe compound label to be certain. We recommend using thread seal tape thread sealant.

Screw tub spout onto pipe and tighten by hand. If final turn by wrench is needed, use small wrench with smooth jaws;otherwise, pad wrench teeth with rag. Pull outward on spout while tightening to avoid scratching wall. DO NOT INSERT TOOL INTO SPOUT END TO TURN SPOUT.

MT692C

Loading...
+ 2 hidden pages