Mitutoyo 264-020 User manual

Mitutoyo Corporation 20-1, Sakado 1-Chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan
User's Manual No.99MAM033A
Rear side
2
4
5
1
3
en
USB Input Tool
Microsoft®, Windows®, and Excel® are registered trademarks and/or trademarks of Microsoft Corporation in the United States and/or other countries.
Safety Precautions
To ensure operator safety, use this instrument in conformance with the directions and specications given in this
Non-conformance to the instructions may compromise safety.
NOTICE
• Be sure to conrm the following to ensure this product is used correctly and safely.
This product operates using power supplied from a PC. Because the PC might generate a large amount of
noise depending on its manufacturer or type, check this product's operation with the entire system before
using it. To check the operation, perform the following procedure.
Connect this product to a measuring tool and a PC, and then tur
1) Perform Zero setting for the measuring tool. (Refer to the meas
2) After measuring, return the contact point/stylus to the zero se
3) returned to zero.
4) Repeat step 3) about ve times. If zero is indicated each time, there is no problem. You can use this
product safely.
5)
If any problems are found, please contact our ofce.
• Do not use this product in locations where it will can be direc
Do not use this product at sites where it will be exposed to di
product in a car left in the sunlight or near open ame.
Applying excessive force to this product or dropping it may dam
Do not disassemble this product or do anything that might cause
Clean dirt of
f this product by wiping it with a lint-free cloth or paper soaked in alcohol. Do not use an organic
solvent such as thinner.
1. Overview
This product is a tool for inputting the measurement data of a measuring tool into a PC. By simply pressing the DATA
button on this product or on the measuring tool, measurement data can be entered into spreadsheet software such as
Excel or a text editor. The operation of entering measurement data values using the PC's keyboard and pressing the
[Enter] key can be executed with a single button press.
n on the PC.
uring tool's User's Manual.)
t position, and check that the display has
tly affected by machining oil, water, dust, etc.
rect sunlight or blowing hot air. Do not leave this
age it. Please handle it with care.
it to short out.
3. Connecting This Product
Connect an optional digimatic connecting cable to the digimatic output port of the measuring tool and to the connector for
measuring tools of this product. Also, connect the USB cable to the USB port of the PC and to the USB connector of this
product. When this product is connected, a driver is automatically installed onto the PC.
Multiple measuring tools can be connected to one PC.
USB2.0
2
*1
*1:Type A
Type A
Type B
DATA
Type C
Type D
NOTICE
• When connecting the Type A/B/G to a measuring tool, be sure to tighten the mounting screws. If the screws are
not tightened, water resistance is not maintained, resulting in a failure. For the Type G, use the screws supplied
with the measuring tool. When attaching or removing screws, use the screwdriver supplied to the measuring tool,
or use a commercially-available size 0 screwdriver. Tighten screws using a torque of about 5 to 8 N·cm. For
details about connection methods, refer to each measuring tool's User's Manual.
When connecting multiple measuring tools, that number of USB po
required USB ports are not available on the PC, use a commercially-available USB hub.
USB hub (commercially­available)
Type E
Type F
Type G
Type SF
rts must be available. When the number of
2. Names and Functions of Each Part
1
3
USB connector side
Connector for measuring tools side
6
4
1 USB cable (A-Micro B type: 06AFZ050)
Connects to this product on one side, and the USB port of a PC or a commercially-available USB hub on the other side.
2
DATA button
Inputs measurement data into the PC. Connector for the foot switch
3
Connects to the optional foot switch (937179T or 12AAJ088).
USB connector (Micro-B Receptacle) Connects to the supplied USB cable.
5
Connector for measuring tools Connects to an optional digimatic connecting cable.
6
Label Indicates the code number, etc., of this product.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Printed in Japan
Mitutoyo Corporation 20-1, Sakado 1-Chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan
4. Inputting Measurement Data
Start up the software that will be used for inputting measurement data.
1
Set the PC's text input to single-byte input (only when using languages that support double-byte characters). 3
2
Change the cell position or move the cursor to the position where the measurement data will be input.
Press the DATA button on this product or on the measuring tool.
4
10.00
MS-Excel
10.000
MS-Excel
NOTICE
• When multiple measuring tools are connected, measurement data can be input from one tool at a time.
• To input measurement data from multiple measuring tools at once, the special software USB-ITPAK (option) is required.
(Refer to "5. Applications of Options".)
5. Applications of Options
The following various functions are available when the special software USB-ITPAK (option) is used.
• Inputting measurement data from multiple measuring tools at once
• Specifying the input destination for measurement data
• Using other software (software compatible with the communication interface of this product) to input measurement data via the
VCP driver (included with USB-ITPAK)
• Inputting measurement data via foot operation (optional foot switch and USB-FSW are required)
For details, refer to each option's User's Manual.
NOTICE
When a foot switch is directly connected to this product, measurement data is input for the measuring tool that is
connected to the product.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Mitutoyo Corporation 20-1, Sakado 1-Chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan
6. Troubleshooting
If this product does not operate correctly, check if any of following problems apply.
If the following solutions do not resolve the problem, please contact the dealer or ofce where you obtained the product.
Problem Solution
• Even after this product is
connected to the PC, it is not
recognized by the PC.
• When the PC is restored from
suspension (sleep mode, standby
mode), this product is not
recognized by the PC.
Measurement data cannot be input
to the PC.
The measurement data input to the
PC is not displayed on separate
lines, but in a single row.
When this product is connected to
your PC or USB hub, etc.,
interference caused by noise
occurs. (For example, the zero
point of the measuring tool shifts.)
NOTICE
This product supports suspension (sleep mode, standby mode) function. However, operation with a PC or USB hub
of any type is not guaranteed.
When operation is impaired by using suspension function, set the PC's power management settings so that
suspension does not occur during operation.
• Disconnect this product from the PC, wait about 10 seconds, and then
reconnect it. Do not operate this product or the PC while the PC is recognizing
this product. Perform the following operations on the PC to check whether this
product is recognized by the PC.
(1) Open the [Device Manager] screen.
While pressing the Windows logo key, press X, and then select [Device
Manager].
(2) Open [Human Interface Devices] and disconnect and reconnect the USB
connector to check that the number of devices in [Human Interface
Devices] or [USB Input Devices] increases or decreases by one.
If the number of devices does not increase or decrease, try the following
solutions.
• If a spare PC or USB hub is available, replace the PC or USB hub being used
with the spare for the check.
• When connecting a USB hub to a USB hub, make sure the longest chain is
only two hubs long.
• The number of this product that can be recognized by a PC is 20 or less.
• If a spare PC or measuring tool is available, replace the PC or measuring tool
being used with the spare for the check.
• If a spare of this product is available, replace the product being used with the
spare. If data can be input using the replacement device, the problem device
may have a damaged DATA button, broken cable, or worn connector.
Set the PC's text input to single-byte input (only when using languages that
support double-byte characters).
This product is compliant with EMC directives, but operation when connected
to a PC or USB hub, etc., of any type is not guaranteed. If interference from
noise occurs, try the following noise measures.
• Attach a ferrite core to the cable of this product (near the USB connector).
• Use a USB hub that is self-powered (powered via its own power adapter).
• Ground the frame ground of the PC case. (Ground the PC case.)
7. Specications
Power supply : +5 V supplied by the PC main body via the USB connector ("A" plug)
Compatible operating systems : Windows 10 (operation using Windows 10 Mobile not guaranteed)
External dimensions : W 38 mm × D 64 mm × H 21 mm (Main body dimensions)
Cable length : 1 m
Mass : Approx. 55 g
Operating temperature : 0°C to 40°C
Storage temperature : -10°C to 60°C
Compliant standards : USB standard: USB 2.0 certied, communication speed: 12 Mbps (Full Speed)
CE marking/UKCA marking : EMC Directive/Electromagnetic Compatibility Regulations: EN61326-1
Immunity test requirement: Clause 6.2 Table 2
Emission limit: Class B
RoHS Directive/The Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment Regulations: EN IEC 63000
• A display value on this product may icker or disappear temporarily due to electromagnetic interference caused by
electrostatic discharge. However, this product will return to normal after removing the interference.
• External power supply models may not acquire correct measurement data due to electromagnetic interference acting
on the AC or DC power line.
If this is the case, check the circumference of the power line and then perform measurement again.
• External power supply models will be turned off automatically if a brownout occurs. However, this product will return to
normal after the recovery from the low voltage.
8. List of Digimatic Connecting Cables by the Tools to Be Connected
Select the digimatic connecting cable applicable to the measuring tool that is to be connected.
Equipped with the output
A
switch Waterproof type
Equipped with the output
B
switch Waterproof type
Equipped with the output
C
switch Straight
Flat (10-pin)
D
Round (6-pin)
E
Flat straight
F
Flat straight
G
Waterproof type
Digimatic S1
SF
straight
Part No.
1m 2m
05CZA624 05CZA625
05CZA662 05CZA663
959149 959150
965014
936937
965013
937387
905409
905338
21EAA190
21EAA194
06AGL011 06AGL021
Form of the
connector of
measuring tool
Main applicable measuring toolConnector type
ABS coolant proof caliper CD-PMX/PM/GM
Coolant proof micrometer MDC-MJ Quantumike MDE
ABS digimatic caliper CD-AX/CX/C
ABS digimatic indicator ID-H/F QM-Height QMH
Quick micro MDQ Digimatic Holtest HTD ABS Borematic SBM-C
ABS digimatic indicator ID-CX/C/S/U
ABS digimatic indicator ID-N/B
ABS digimatic indicator ID-F_NX
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...