Mitsubishi Electronics SKM22ZD-S, SKM25ZD-S, SKM35ZD-S, SKM50ZD-S, SKM28ZD-S User Manual

5 (1)
This air conditioner complies with EMC Directive 89/336/EEC, LV
Directive 73/23/EEC.
Ce climatiseur est conforme à la Directive EMC: 89/336/EEC, LV
Directive 73/23/EEC.
Dieses Kimagerät erfüllt die EMC Direktiven 89/336/EEC, LV
Direktiven 73/23/EEC.
Questo condizionatore d’aria è conforme alla Direttiva EMC: 89/
336/EEC, LV Direttiva 73/23/EEC.
Deze airconditioner voldoet aan EMC Directive 89/336/EEC, LV
Directive 73/23/EEC.
Este acondicionador de aire cumple con la directiva EMC: 89/
Este aparelho de ar condicionado está em conformidade com a
Directiva EMC 88/336/CEE e a Directiva LV 72/23/CEE.
∞˘Щfi ЩФ ОПИМ·ЩИЫЩИОfi В›У·И Ы‡МКˆУФ Ì ÙȘ ÚԉȷÁڷʤ˜ Ù˘
√‰ËÁ›·˜ EMC 88/396 Î·È Ù˘ √‰ËÁ›·˜ LV 73/23 Ù˘ ∂√∫.
USER’S MANUAL
MITSUBISHI DAIYA
ROOM AIR CONDITIONER
RWA012A226
ENGLISH
SKM22ZD-S
SKM25ZD-S
SKM28ZD-S
SKM35ZD-S
SKM50ZD-S
MANUEL DE L’UTILISATEUR
CLIMATISEUR D’INTERIEUR
ANWENDERHANDBUCH
BETRIEBSEINHEIT KLIMAGERA
¨
T
DEUTSCH
ISTRUZIONI PER L’USO
CONDIZIONATORE D’ARIA COMPATTO
ITALIANO
MANUAL DEL PROPIETARIO
ACONDICIONADOR AMBIENTAL DE AIRE INCORPORADO
ESPAN
˜
OL
GEBRUIKERSHANDLEIDING
KAMER-AIR-CONDITIONING
NEDERLANDS
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO DE INTERIOR
PORTUGUÊS
√¢∏°π∂™ Ã∏™∏™
∫§πª∞∆π™∆π∫√ ∂™ø∆∂ƒπ∫√À Ãøƒ√À
∂§§∏¡π∫∞
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
КОМНАТНЫЙ КОНДИЦИОНЕР ВОЗДУХА
РУССКИЙ
KULLANIM KILAVUZU
SPL‹T KL‹MA
TÜRKÇE
FRANÇAIS
C
–1–
Thank you for purchasing a Mitsubishi Daiya Air Conditioner. To get the best long-lasting
performance, read and follow this User’s Manual carefully before using your air condi-
tioner. After reading, please store the Manual in a safe place and refer to it for operational
questions or in the event of any irregularities.
This air conditioner is intended for domestic use.
A new refrigerant (R410A) is used in this air-conditioner. When asking the dealer for
service or inspection and maintenance, explain the dealer about this matter.
Contents
Safety precautions......................................................................................................................... 2
Choice of operations and features ................................................................................................ 4
Name of each part and its function ............................................................................................... 5
Operation and indication section for remote control .................................................................... 7
AUTO mode operation procedure ................................................................................................ 8
Temperature adjustment during AUTO........................................................................................ 8
COOL/HEAT/DRY mode operation procedure ........................................................................... 9
Concerning high power operation ................................................................................................ 9
Concerning economy operation ....................................................................................................9
Air flow direction adjustment procedure .................................................................................... 10
Emergency run operation............................................................................................................ 10
Present time setting produre ....................................................................................................... 11
OFF-TIMER operation procedure .............................................................................................. 11
ON-TIMER operation procedure................................................................................................ 12
Program TIMER operation procedure ........................................................................................ 12
About TIMER operation............................................................................................................. 13
About FAN SPEED .................................................................................................................... 13
Remote control handling procedure ........................................................................................... 13
When the operation fails with the remote control ...................................................................... 14
Operating hints ........................................................................................................................... 14
Maintenance................................................................................................................................ 15
Has the unit been installed correctly? ......................................................................................... 16
About the Multiple Air-conditioner............................................................................................ 17
Troubleshooting .......................................................................................................................... 17
Please remember! ....................................................................................................................... 18
When to contact your distributor without delay ......................................................................... 19
Air conditioner operating conditions .......................................................................................... 19
Power Blackout Auto Restart Function ...................................................................................... 19
Characteristics of HEAT mode operation .................................................................................. 20
Self diagnosis function ............................................................................................................... 20
ENGLISH
–2–
Safety precautions
Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system.
The safety precautions are classified as “
DANGER” and “ CAUTION”. Precautions as shown in the column “ DANGER” indicate that
improper handling could have dramatic consequences like death, serious injury, etc. Nevertheless, even precautions as shown in the column
CAUTION” might pose a serious problem, depending on the circumstances. Please observe these precautions with great care, since they are
essential to your safety.
Symbols which appear frequently in the text have the following meaning:
When you have read the instruction manual, please keep it near at hand for consultation. If someone else takes over as operator, make certain that the
manual is also passed on to the new operator.
Strictly prohibited Provide positive earthing
Do not expose yourself to the cooling air for prolonged peri-
ods.
This could affect your physical condition and cause health problems.
Make sure that the system has been properly earthed.
Earth cables should never be connected to a gas pipe, municipal water pipe, light-
ning conductor or telephone earth cable. Incorrect installation of the earth cable
may produce an electric shock.
Depending on the place of installation, a circuit breaker may
be necessary.
If you don’t fit a circuit breaker, you may cause an electric shock.
Do not install near places where inflammable gas may leak.
Gas leaks may cause fire.
Make sure that you drain the hose properly, so that all the
water has dripped out.
Negligence may cause flooding in the room resulting in wet furniture.
Observe instructions with
great care
Do not insert anything into the air inlet.
This may cause injury, as the internal fan rotates at high speed.
INSTALLATION PRECAUTIONS
DANGER
CAUTION
OPERATION PRECAUTIONS
DANGER
LPG
The system is meant for domestic, residential etc. use.
If used in inferior environments, such as an engineering workplace, the equipment
may function poorly.
The system must be installed by your dealer or a qualified pro-
fessional.
It is not advisable to install the system yourself, as faulty handling may cause leak-
age of water, electric shock or fire.
Store the remote controller out of reach of infants.
Failure to observe this may result in the batteries
being swallowed or other accidents.
–3–
Safety precautions
CAUTION
Do not place anything containing wa-
ter, like vases, on top of the unit.
Water entering the unit could damage the insula-
tion and therefore cause an electric shock.
Do not handle the switches with wet
hands.
This may cause an electric shock.
Do not wash the air conditioner with wa-
ter.
This could cause an electric shock.
The system should only be used for its original purpose
and not for anything else like, for instance, preservation of
food, plants or animals, precision devices or works of art.
The system is only intended for use in ordinary domestic rooms.
Any other use of the system may damage the quality of food, etc.
Do not install the system at a place
where the air stream of the blower is
aimed directly at plants or animals.
This will damage their health.
Do not sit on the outdoor unit nor put
anything on it.
If the unit falls down or things drop off it, people
could get hurt.
You should not expose any combus-
tion appliance directly to the air
stream of the air conditioner.
The appliance may then work inadequately.
Do not place a combustible insecticide
or paint spray near the blower, nor aim it
directly at the system.
This may result in a fire.
Consult your dealer for repairs to the
system.
Wrong repairs could cause an electric shock, fire, etc.
If you notice anything abnormal (smell of
burning, etc.), stop the system, turn off the
power switch and consult your dealer.
Continued use of the system in abnormal circum-
stances may result in malfunctioning, electric shock,
fire, etc.
After a long period of use, check the unit's
support structure from time to time.
If you don't repair any damage straightaway, the
unit may fall down and cause personal injury.
If you operate the system together with
a combustion appliance, you must regu-
larly ventilate the indoor air.
Insufficient ventilation may cause accidents due to
oxygen deficiency.
If the air conditioner is moved else-
where, contact your dealer or a pro-
fessional fitter.
Faulty installation may cause water leakage, elec-
tric shock, fire, etc.
Don’t swing from the system.
If the system falls down,
you may get injured.
Only use approved fuses.
Use of steel or copper wire instead of an approved
fuse is strictly forbidden, as it may cause a breakdown
or fire.
PRECAUTIONS FOR TRANSFER OR REPAIRS
DANGER
Stand firmly on a stepladder or other
stable object when removing the in-
take grill and filters.
Failure to observe this may result in injury through
insecure objects toppling over.
Do not touch the aluminum fins on the
air heat exchanger.
Failure to observe this may result in injury.
When you clean the system, stop the
unit and turn off the power switch.
Never clean the unit while the internal fan is rotating.
–4–
Page 10
Page 11, 12
There are two timers, for ON and OFF.
They can be set as desired.
Page 13
When using the timer to switch on, the sys-
tem become operational shortly before the
set time, depending on the room tempera-
ture so that the desired temperature is
reached at the set time.
Choice of operations and features
Characteristics
Amenity facility
TIMER procedure
AIR SCROLL
This function sets the unit at the most suitable angle
for blowing, imitating a natural breeze.
MEMORY FLAP
Once the flap position has been set, the unit will
memorise it and continue in the same position the
next time.
Page 8
Automatic selection of operating mode.
The Auto mode automati-
cally selects the operation
mode (HEAT, COOL or
DRY), depending on the
room temperature when
switched on.
Adjustment of
airflow
AUTO
Page 9
Cooling by extracting heat from the room.
COOL
Choise of operations
Page 9
The unit draws in heat from the outside air, transfers it inside and
heats the room.
HEAT
Page 9
Drying by extracting damp from the room.
Functioning of micro-computer depends on setting and room tem-
peratures. It dehumidifies while keeping room temperature almost
constant.
DRY
Page 9
Turning up the power operates the air condi-
tioner in the power cooling and heating
mode.
HI POWER mode
Page 9
This is an economic and healthy level of op-
eration.
ECONOMY mode
5
Name of each part and its function
INDOOR UNIT
SKM22ZD-S
SKM25ZD-S
SKM28ZD-S
Air inlet grille
Draws in the indoor air.
Refrigerant piping connection electric flex
Up/down air flow direction adjustment flap
Page 10
Wireless remote control
Page 7
Drain hose
Drains water from the dehumidified air.
Left/right air flow adjustment fin
Page 10
Air outlet
Air blows out of here.
Air filter
Removes dust or dirt from the inlet air.
Page 15
Unit indication section and remote control signal receiver
Unit operation section
Room temperature detector
OUTDOOR UNIT
SCM45ZD-S
SCM60ZD-S
SCM80ZD-S
Air inlet
(on side & rear surface)
SKM35ZD-S
SKM50ZD-S
Photocatalytic washable deodorizing filter
Natural enzyme filter
Air outlet
–6–
Unit indication section
How to open the suction grill
How to close the suction grill
Push both sides evenly and press further lightly at the center.
Place fingers at the recesses on both sides of the grill and pull up the grill to this side so that it will be opened by about 60 degrees.
Unit ON/OFF button
Secure either the upper or lower edge of the suction grill by lightly pushing it in,
and then close the grill.
When removing the suction grill for internal cleaning or others, open the grill by
65 degrees and then pull it to this side.
In emergencies, this button can be used for turning on/off the unit when remote control is not available.
Page 10
Removal, installation of suction grill
ON/OFF button
RUN (HOT KEEP) light (green)
Illuminates during operation.
Blinks at air flow stop due to the ‘HOT KEEP’.
Page 17
ECONOMY light (orange)
Illuminates during ECONOMY operation.
TIMER light (yellow)
Illuminates during TIMER operation.
HI POWER light (green)
Illuminates during HI POWER operation.
–7–
LO
MED
HI
AUTO
HI POWER
ECONO
ON OFF
AM PM
Operation and indication section for remote control
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
ON OFF
AM PM
Operation section
FAN SPEED button
Each time the button is pushed, the indi-
cator is switched over in turn.
The above illustration shows all controls, but in practice
only the relevant parts are shown.
OPERATION MODE select button
Each time the button is pushed, the indi-
cator is switched over in turn.
AIR FLOW button
This button changes the flap mode. When
pressed, this button changes the mode in the
following order:
Page 10
ON/OFF button
Press for starting operation, press again for
stopping.
HI POWER button
This button changes the HI POWER mode.
Page 9
ECONOMY button
This button changes the ECONOMY mode.
Page 9
RESET switch
Switch for resetting microcomputer.
Page 13
ON TIMER button
This button selects ON TIMER operation.
Page 12
Clock switch
This switch for setting the clock.
Page 11
OFF TIMER button
This button selects OFF TIMER operation.
Page 11
TEMPERATURE button
This button sets the room temperature.
(This button changes the present time and
TIMER time.)
CANCEL button
This button cancels the ON timer and OFF
timer.
RESERVE button
This button sets the present time and
TIMER time.
Indication section
OPERATION MODE Indicator
Indicates selected operation with lamp.
[
(Auto) • (Cool) • (Heat) • (Dry)]
TEMPERATURE Indicator
Indicates set temperature.
(Does not indicate temperature when operation
mode is on AUTO)
FAN SPEED Indicator
Indicates set air flow rate with lamp.
AIR FLOW Indicator
Shows selected flap mode.
HI POWER MODE indicator
Indicates during Hi power mode operation.
ECONOMY MODE indicator
Indicates during economy mode operation.
ON TIMER Indicator
Indicates during ON TIMER operation.
Clock Indicator
Indicates present time or timer setting time.
OFF TIMER Indicator
Indicates during OFF TIMER operation.
Transmission procedure
When each button on the remote control is pressed – with the remote control pointing towards the air conditioner unit – a signal is transmitted.
When the signal is received correctly, the unit will beep.
(Air scroll) (SWING)
–8–
Aim the remote control at the air conditioner.
Press the ON/OFF button.
When the unit is not in AUTO mode:
Press MODE button.
Move the [ mark] to the (Auto) position.
Temperature adjustment during AUTO
Air temperature adjustment is possible even during automatic operation. There are 6 levels of adjustment possible with the button or the button.
1
AUTO mode operation procedure
Automatically selects the operation mode (HEAT, DRY, COOL) depending on the room temperature when switched on.
2
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
AM
Air flow direction adjustment
procedure.
Page 10
NOTE
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
AM
WARM
Press the
button.
COOL
Press the
button.
1
When a change in temperature is desired.
Press the or button.
If you don’t want the AUTO mode programme, change to
HEAT, DRY or COOL instead of AUTO.
Page 9
AUTO mode can be
operated by simply
pressing the ON/OFF
button.
To stop: Press the ON/OFF button.
Each time the
button is pushed, the switch over occurs in the following order –6 –5 ............ –1 ±0 +1 ............ +6.
When +6 is indicatored, even if the
button is pushed, the indicator does not change.
Each time the
button is pushed, the switch over occurs in the following order +6 +5 ............ +1 ±0 –1 ............ –6.
When –6 is indicatored, even if the
button is pushed, the indicator does not change.
Air is not blowing out during the op-
eration.
Page 18
Simultaneous automatic operation.
Page 17
When the included clean filter is in-
stalled the air conditioner will clean
the air during automatic operation.
–9–
1
2
COOL/HEAT/DRY mode operation procedure
Air flow direction adjustment procedure. Page 10
Program changing procedure
Set the new program.
The operation program can also be set or changed when
the air conditioner is not in operation.
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
AM
Aim the remote control at the air conditioner.
Press the ON/OFF button.
Press the MODE select button.
Move the [ mark] to the desirable operation position.
(Cool), (Heat), (Dry)
Press the TEMP button.
Press or button for the desired temperature.
Standard
Press the FAN SPEED button
Set the air flow rate as desired.
4
3
COOL
DRY
FAN
HEAT
26°C~28°C21°C~24°C22°C~24°C
To stop: Press the ON/OFF button.
NOTE
Concerning high power operation
Pressing the high power button intensifies the operating power and initiates a powerful cooling or heating operation for 15 minutes continuously.
The remote controller illuminates but the wind capacity display is erased.
Concerning economy operation
Pressing the economy button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating. The unit operates
1.5°C higher than the setting temperature for the weak wind capacity during cooling or 2.5°C lower than that during heating. A message is
displayed on the remote controller. The wind capacity display is erased.
NOTE
NOTE
During the high power operation, the room temperature is not con-
trolled. When it causes an excessive cooling or heating, press the
high power button once more to cancel the high power operation.
High power operation is not available during the dehumidifying
operation.
During ON timer operation, HI POWER operation will start when
the ON time is reached.
If the economy operation is selected while operating with the
strong or medium wind capacity, it takes about 1 minute before the
wind capacity drops to the weak level.
HI POWER
ECONO
When the following operations are conducted HI POWER opera-
tion will be canceled.
1 When the HI POWER button is pressed again.
2 When the operation mode is changed.
3 When ECONOMY operation is conducted.
When the following operations are conducted ECONOMY opera-
tion will be canceled.
1 When the ECONOMY button is pressed again.
2 When HI POWER operation is selected.
Air is not blown out during the operation.
Page 18
The air-conditioners cannot be in different
operating modes at the same time, such as
one unit being in the “Cool” mode and one
unit being in the “Heat” mode.
10
Air scroll
Flap moves up and down
continuously.
If the room temperature control (thermostat) switches to the heating mode or if the defrosting operation is on, the blow flap changes automatically to a horizontal
position.
If the heating operation has just started and the room temperature is still low, it may take a while before the flap moves to the above sway operation angle.
The flap may stop at the tilted down-blow position during the “sway operation” in the heating mode.
NOTE
MEMORY FLAP (FLAP STOPPED)
Adjusting left/right air flow direction
CAUTION
Please stop the air conditioner when
adjusting the air flow direction.
When you press the AIRFLOW button once while the flap is operating, it stops swinging at an
angle.Since this angle is memorized in the micro-computer, the flap will automatically be set at this
angle when the next operation is started.
Recommended angle of the flap when stopping
Emergency run operation
The ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.
Operation program
OPERATION MODE : AUTO
FAN SPEED : AUTO
AIR FLOW : AUTO
Operation starts by pressing the ON/OFF button; it stops if you press the button again.
Unit ON/OFF button
DANGER
Avoid constant airflow to the body for hours on end.
CAUTION
When in COOL or DRY operation, do not operate for hours on end with the air
flow blowing straight down. Otherwise, condensation may appear on the outlet
grill and drip down.
Do not try to adjust the flaps by hand, as the control angle may change or the flap
may not close properly.
Air flow direction adjustment procedure
HEAT
(Horizontal
blowing)
(Slant forward
blowing)
COOL, DRY
Adjust the direction by moving the left/right
air flow fin by hand.
SWING FLAP
Thick line : moves quickly
Thin line
: moves slowly
Thick line
: moves quickly
Thin line
: moves slowly
Stops at this position
for 5 seconds.
Stops at this position
for 5 seconds.
In COOL and DRY operation In HEAT operation
Adjusting up/down air flow direction
Up/down direction can be adjusted with the AIRFLOW button on the remote control. Each time when you press this button the mode changes
as follows:
Change to AIRFLOW mode.
(Air scroll) (SWING)
(flap stopped)
11
2
Present time setting procedure
When inserting the batteries, the present time is automatically set to PM 1:00.
Example: Set to AM 10:30.
Press the TIME switch.
Press with the tip of a ball pen, etc.
The time indicator blanks and can be set to the current time.
Press the or button.
(Set to AM 10:30)
Press the RESERVE button.
The indication changes from blinking to steady lighting and the setting is complete.
The timer is set on the basis of the present time, so please set it correctly.
1
3
NOTE
Press within
15 sec.!
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
AM
1
2
OFF-TIMER operation procedure
The unit stops automatically at the end of the set period of time.
3
Example: You wish it to stop PM 10:30.
If the air conditioner is not operating, aim the remote control at the air conditioner.
Press the ON/OFF button.
Press the OFF TIMER button.
OFF TIMER indicator
OFF
is blinking.
Press the or button.
Each time the button is pressed, the indicator is switched in the order of:
AM
0:00
AM
0:10
AM
0:20
... ...
AM
1:00
AM
1:10
Each time the button is pressed, the indicator is switched in the order of:
AM
0:00
PM
11:50
PM
11:40
... ...
PM
11:00
PM
10:50
Set at PM 10:30.
Press the RESERVE button.
The indication changes from blinking to steady lighting and the setting is complete.
The timer light (yellow) is on.
The unit stops at the end of the set period of time.
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
OFF
PM
4
Changing of set time
Set a new time by using the OFF TIMER button.
Depending on the temperature, the operation may be stopped earlier than the set
time.
Releasing procedure
Press the CANCEL button to turn off the timer indicator.
NOTE
12
ON-TIMER operation procedure
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
ON
AM
1
2
Changing of set time
Set a new time by using the ON TIMER button.
Example: In the case you wish to bring the temperature to nearly set temperature in at AM 8:00.
Press the ON TIMER button.
ON TIMER indicator
ON
is blinking.
Press the or button.
Each time the button is pressed, the indicator is switched in the order of:
AM
0:00
AM
0:10
AM
0:20
... ...
AM
1:00
AM
1:10
Each time the button is pressed, the indicator is switched in the order of:
AM
0:00
PM
11:50
PM
11:40
... ...
PM
11:00
PM
10:50
Set at AM 8:00.
Press the RESERVE button.
The indication changes from blinking to steady lighting and the setting is complete.
The timer light (yellow) is on.
Operation starts 5 to 60 minutes before the set time.
The TIMER light goes out at the set time.
Releasing procedure
Press the CANCEL button to turn off the timer indicator.
3
Program TIMER operation procedure
The timer operations that consist of the combination of the timer being set at both on and off. Once this has been set and operations started,
operations will commence and end at the same time every day as long as the ON/OFF button is not pressed.
Example: When it is desired to stop at 10:30 PM, and then start operation at 8:00 AM,
near the set temperature.
Press the ON/OFF button.
OFF TIMER operation setting
Set by the procedures on page 11.
Set to
OFF
PM
.
ON TIMER operation setting
Set by the above mentioned ON TIMER operation procedures.
Set to
ON
AM
.
The setting of the lighting of the timer lamp (yellow) of this unit is complete.
The time will be displayed on the remote control unit. The display will change
depending on the operational status.
ON OFF
ON OFF
1
(Stopped) (Operating)
Changing of set time
Set a new time by using the OFF TIMER or ON TIMER button.
Releasing procedure
Press the CANCEL button to turn off the timer indicator.
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
ON OFF
PM
If the room temperature is at near optimum temperature at the set time, the operation starts 5 to 60 minutes before the set time. Page 13
Loading...
+ 29 hidden pages