Mitsubishi Electronics QJ71E71-B5, QJ71E71-100, QJ71E71, QJ71E71-B2 User Manual

0 (0)
Mitsubishi Electronics QJ71E71-B5, QJ71E71-100, QJ71E71, QJ71E71-B2 User Manual

Series HMI Connection Manual

Mitsubishi Q Series Ethernet

Supports QJ71E71 / QJ71E71-B2 / QJ71E71-B5 / QJ71E71-100 Series Module

HMI Factory Setting:

Baud rate: 192.168.0.1

Controller Station Number: 1025

Control Area / Status Area: D0 / D10

Connection

Standard jumper Cable/ Network Cable without jumper (Auto-detected by HMI)

Definition of PLC Read/Write Address

 

 

 

 

a. Registers

 

 

 

 

 

Type

Format

Read/Write Range

 

 

Note

 

 

Word No. (n)

 

 

 

 

Word

 

Input

Xn

X0 – X1FF0

Hexadecimal,

 

 

 

 

 

2

Output

Yn

Y0 – Y1FF0

Word

Hexadecimal,

 

 

 

 

 

2

Internal Relay

Mn

M0 – M8176

Word

2

Special Internal Relay

Mn

M9000 – M9240

Word

3

Link Relay

Bn

B0 – B1FF0

Word

Hexadecimal,

 

 

 

 

 

2

Annunciator

Fn

F0 – F2032

Word

2

Timer Value

TNn

TN0 – TN2047

Word

 

Counter Value

CNn

CN0 – CN2047

Word

 

Data Register

Dn

D0 – D8191

Word

 

Special Data Register

Dn

D9000 – D9255

Word

 

Link Register

Wn

W0 – W1FFF

Word

Hexadecimal

b. Contacts

 

 

 

 

 

Type

Format

Read/Write Range

 

Note

Bit No. (b)

 

 

 

 

 

 

Input

Xb

X0 – X1FFF

 

 

Hexadecimal

134

V1.01 Revision November, 2011

Series HMI Connection Manual

Output

Yb

Y0 – Y1FFF

Hexadecimal

Internal Relay

Mb

M0 – M8191

 

Special Internal Relay

Mb

M9000 – M9255

 

 

 

 

 

Type

Format

Read/Write Range

Note

Bit No. (b)

 

 

 

Link Relay

Bb

B0 – B1FFF

Hexadecimal

Annunciator

Fb

F0 – F2047

 

Timer Contact

TSb

TS0 – TS2047

 

Timer Coil

TCb

TC0 – TC2047

 

Counter Contact

CSb

CS0 – CS2047

 

Counter Coil

CCb

CC0 – CC2047

 

NOTE

1)Before using this communication protocol, the user needs to set communication module via GX Developer programming tools. For more detailed information regarding the setting method, please refers to Mitsubishi PLC User Manual.

2)The device address must be the multiple of 16.

3)The device address must be the multiple of 16 plus 9000.

V1.01 Revision November, 2011

135