Mitsubishi Electronics GT15-75QBUSL, GT15-75ABUS2L, GT15-75ABUSL, GT15-75QBUS2L User Manual

0 (0)
Mitsubishi Electronics GT15-75QBUSL, GT15-75ABUS2L, GT15-75ABUSL, GT15-75QBUS2L User Manual

GT15 BUS CONNECTION UNIT

User's Manual

GT15-75QBUSL

GT15-75QBUS2L

GT15-75ABUSL

GT15-75ABUS2L

Thank you for purchasing the GOT1000 Series.

Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.

MODEL

GT15-75BUSL-U

 

 

MODEL

1D7M04

CODE

 

IB(NA)-0800298-B(0504)MEE

zSAFETY PRECAUTIONSz

(Always read these precautions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.

The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".

Indicates that incorrect handling may cause DANGER hazardous conditions, resulting in death or

severe injury.

Indicates that incorrect handling may cause CAUTION hazardous conditions, resulting in medium or

slight personal injury or physical damage.

Note that the CAUTION level may lead to a serious accident according to the circumstances.

Always follow the precautions of both levels because they are important to personal safety.

Please save this manual to make it accessible when required and always forward it to the end user.

[DESIGN PRECAUTIONS]

CAUTION

zDo not bunch the control wires or communication cables with the main circuit or power wires, or lay them close to each other. As a guide, separate the lines by a distance of at least 100 mm (3.94 inch) otherwise malfunctions may occur due to noise.

[INSTALLATION PRECAUTIONS]

DANGER

zBefore mounting or dismounting this unit to or from the GOT, always shut off GOT power externally in all phases.

Not doing so can cause a unit failure or malfunction.

CAUTION

zUse this unit in the environment given in the general specifications of the GT15 User's Manual.

Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

zWhen installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range.

Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to screw or unit damage.

[WIRING PRECAUTIONS]

DANGER

zBefore connecting the Bus connection cable to this unit, always shut off GOT power and PLC CPU power externally in all phases.

Not doing so can cause a malfunction.

CAUTION

zInsert and fit the bus connection cable into the connector of the unit to be connected until it "clicks".

After fitting, check for lift which can cause a malfunction due to a connection fault.

[STARTUP AND MAINTENANCE PRECAUTIONS]

DANGER

zBefore starting cleaning, always shut off GOT power externally in all phases. Not doing so can cause a unit failure or malfunction.

CAUTION

zDo not disassemble or modify any unit.

This will cause failure, malfunction, injuries, or fire.

zDo not touch the conductive areas and electronic parts of this unit directly.

Doing so can cause a unit malfunction or failure.

zAlways secure the cables connected to the unit, e.g. run them in conduits or clamp them.Not doing so can cause unit or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault.

zDo not hold the cable part when unplugging any cable connected to the unit. Doing so can cause unit or cable damage or a malfunction due to a cable contact fault.

zAlways make sure to touch the grounded metal to discharge the electricity charged in the body, etc., before touching the unit. Failure to do so may cause a failure or malfunctions of the unit.

[DISPOSAL PRECAUTIONS]

CAUTION

z Dispose of this product as industrial waste.

[TRANSPORTATION PRECAUTIONS]

CAUTION

zMake sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User's Manual, as they are precision devices.

Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

Manuals

The following shows manuals relevant to this product.

Detailed Manual

Manual name

Manual Number

(Type code)

 

 

 

GT15 User's Manual

SH-080528ENG

(Option)

(1D7M23)

 

 

GOT1000 Series Connection Manual

SH-080532ENG

(Option)

(1D7M26)

 

 

Relevant Manuals

For relevant manuals, refer to the PDF manual stored within the drawing software used.

© 2004 MITSUBISHI ELECTRIC CORPORATION

Compliance with the EMC and Low Voltage Directives

When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives, refer to Chapter 4, "EMC Directives and Low Voltage Directives" of the manual (GT15 General Description) included with the GOT used.

The CE logo is printed on the rating plate of the GOT, indicating compliance with the EMC and low voltage directives.

By making this product conform to the EMC directive and low voltage instruction,it is not necessary to make those steps individually.

Product Components

The bus connection unit consists of the following items.

Product name

Quantity

Any one of GT15-75QBUSL,

GT15-75QBUS2L, GT15-75ABUSL, 1 GT15-75ABUS2L

Seals

12

1. Overview

This User's Manual describes the GT15 bus connection unit (hereafter abbreviated to the bus connection unit).

There are the following bus connection unit types.

Refer to the GT15 User's Manual for the applicable GOT.

Product

Model name

Description

name

 

 

 

 

 

 

GT1575QBUSL

QCPU (Q Mode) bus connection

 

Number of connectors: 1

 

 

Bus

GT1575QBUS2L

QCPU (Q Mode) bus connection

Number of connectors: 2

connection

 

 

 

QnA/ACPU bus connection

unit

GT1575ABUSL

 

Number of connectors: 1

 

 

 

GT1575ABUS2L

QnA/ACPU bus connection

 

Number of connectors: 2

Use the bus connection unit for making bus connection of the GOT.

Select the used bus connection unit according to the connection target and connection position.

<Bus connection unit selection example>

(1)Select the bus connection unit according to the connection target.

QCPU (Q Mode), motion controller Q series

: GT15-75QBUSL/GT15-75QBUS2L ACPU, QnACPU, motion controller A series

: GT15-75ABUSL/GT15-75ABUS2L

(2) Select the bus connection unit according to the GOT connection position.

Placed midway

: GT15-75QBUS2L/GT15-75ABUS2L

Placed at end

:GT15-75QBUSL/GT15-75ABUSL GT15-75QBUS2L/GT15-75ABUS2L

Refer to the GOT1000 Series Connection Manual for details of bus connection.

2. Specifications

The performance specifications of the bus connection unit are indicated below.

Refer to the used GT15 User's Manual for the general specifications of the bus connection unit.

Item

GT15-

GT15-

GT15-

 

GT15-

75QBUSL

75QBUS2L

75ABUSL

 

75ABUS2L

 

 

 

 

 

 

 

 

I/O

16 points (I/O assignment:

32 points (I/O assignment:

occupied

16 intelligent points)

Special

32 points)

points

 

 

 

 

 

 

 

 

 

 

 

Internal

 

 

 

 

 

consumed

0.44A

0.44A

0.12A

 

0.12A

current

 

 

 

 

 

 

(DC5V)*

 

 

 

 

 

 

 

 

 

 

 

Weight

0.13kg

0.14kg

0.13kg

 

0.14kg

 

 

 

 

 

 

*When the GOT power is on, the internal current consumption is included in the current consumption of the GOT.

When the GOT power is off, the internal current is supplied from the power supply of the PLC system.

3. Part Names and External Dimensions

 

136.8(5.39)

101.8(4.01)

4)

5)

 

 

4)

A

2)

1)

17.6 (0.69)

 

*1

 

Back view

3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT1575QBUSL

2.3(0.09)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT1575QBUS2L

2.3(0.09)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT1575ABUSL

3.9(0.15)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GT1575ABUS2L

3.9(0.15)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit: mm (inch)

*1 When the GT15-75QBUSL/GT15-75ABUSL is used, only the IN side connector is available.

No.

Name

Description

 

 

 

1)

Bus connector (IN side)

Connector for connecting the

bus connection cable (IN side)

 

 

 

2)

Bus connector (OUT

Connector for connecting the

side)

bus connection cable (OUT side)

 

 

 

 

3)

Extended connector

For connecting the extended

connector of the GOT

 

 

 

 

 

4)

Mounting screw

Screw (M3 screw) for fixing the

unit to the GOT

 

 

 

 

 

5)

Rating plate

-

 

 

 

4.Installation Procedure

(1)Power off the GOT.

(2)Remove the two expansion unit covers of the GOT.

(3)Fit the bus connection unit along the groove of the GOT case.

(4)Fasten the bus connection unit by tightening its mounting screws (4 places) with tightening torgue 0.36 to 0.48 N•m.

(5) After tightening screws, attach the supplied seals.

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.

For safe use

This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.

Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.

This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.

Country/Region

Sales office/Tel

U.S.A

Mitsubishi Electric Automation Inc.

 

 

500 Corporate Woods Parkway Vernon Hills, IL 60061

 

 

Tel : +1-847-478-2100

Brazil

MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.

 

 

Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar

 

 

Paraiso, Sao Paulo, SP Brazil

 

 

Tel : +55-11-5908-8331

Germany

Mitsubishi Electric Europe B.V. German Branch

 

 

Gothaer Strasse 8 D-40880 Ratingen, GERMANY

 

 

Tel : +49-2102-486-0

U.K

Mitsubishi Electric Europe B.V. UK Branch

 

 

Travellers Lane, Hatfield, Herts., AL10 8XB,UK

 

 

Tel : +44-1707-276100

Italy

Mitsubishi Electric Europe B.V. Italian Branch

 

 

Centro Dir. Colleoni, Pal. Perseo-Ingr.2

 

 

Via Paracelso 12, 20041 Agrate B., Milano, Italy

 

 

Tel : +39-039-6053344

Spain

Mitsubishi Electric Europe B.V. Spanish Branch

 

 

Carretera de Rubi 76-80

 

 

08190 - Sant Cugat del Valles, Barcelona, Spain

 

 

Tel : +34-93-565-3131

France

Mitsubishi Electric Europe B.V. French Branch

 

 

25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France

 

 

TEL: +33-1-5568-5568

South Africa

Circuit Breaker Industries LTD.

 

 

Tripswitch Drive, Elandsfontein Gauteng, South Africa

 

 

Tel : +27-11-928-2000

Hong Kong

Ryoden Automation Ltd.

 

 

10th Floor, Manulife Tower, 169 Electric

 

 

Road, North Point, HongKong

 

 

Tel : +852-2887-8870

China

Ryoden Automation Shanghai Ltd.

 

 

3F Block5 Building Automation

 

 

Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China

 

 

Tel : +86-21-6120-0808

Taiwan

Setsuyo Enterprise Co., Ltd.

 

 

6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang,

 

 

Taipei Hsine, Taiwan

 

 

Tel : +886-2-2299-2499

Korea

HAN NEUNG TECHNO CO.,LTD.

 

 

1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong

 

 

Kangsec-ku, Seoul, Korea

 

 

Tel : +82-2-3660-9552

Singapore

Mitsubishi Electric Asia Pte, Ltd.

 

 

307 Alexandra Road #05-01/02,

 

 

Mitsubishi Electric Building Singapore 159943

 

 

Tel : +65-6473-2308

Thailand

F. A. Tech Co.,Ltd.

 

 

898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3

 

 

Road, Bangkpongpang, Yannawa, Bangkok 10120

 

 

Tel : +66-2-682-6522

Indonesia

P.T. Autoteknindo SUMBER MAKMUR

 

 

Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan

 

 

Industri/Pergudangan Jakarta - Utara 14440

 

 

Tel : +62-21-663-0833

India

Messung Systems Put,Ltd.

 

 

Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,

 

 

PUNE-411026, India

 

 

Tel : +91-20-712-2807

Australia

Mitsubishi Electric Australia Pty. Ltd.

 

 

348 Victoria Road, PostalBag, No 2,

 

 

Rydalmere, N.S.W 2116, Australia

 

 

Tel : +61-2-9684-7777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice.

Printed in Japan on recycled paper.

Loading...