OWNER’S MANUAL
For LDR-14 Remote Control 043 955
OM-2808 196 319H
May 2005
WARNING
1. Typical Connection
1
READ SAFETY BLOCKS in welding power
source Owner’s Manual before proceeding.
3
Y Stop engine.
1 LDR-14 Remote Control
2 Remote 14 Receptacle
3 120 V AC Auxiliary Power Receptacle
Insert LDR-14 remote 14 plug into match-
ing 14-socket receptacle on welding generator. Tighten collar.
2. Using LDR-14 120 V AC Receptacle
2
802 173-K
Insert LDR-14 auxiliary power plug into
matching 120 V AC receptacle on welding
generator.
1 120 V 20 A AC GFCI
1
Receptacle
Receptacle supplies 60 Hz singlephase power at weld/power speed.
Maximum output from receptacle
equals maximum output from corresponding receptacle on welding
generator.
Overload protection is provided by
the corresponding ac receptacle
circuit breaker on the welding generator.
If a ground fault is detected, the
LDR-14 GFCI Reset button pops
out and the receptacle does not
work. Check for faulty tools
plugged in receptacle. Press button to reset GFCI receptacle and
resume operation.
. At least once a month, run en-
gine at weld/power speed and
press test button to verify
GFCI is working properly.

3. Combination Remote Amperage/Voltage Control
NOTE
Example Of Combination Front Panel
And Remote Amperage Control
Set Switch
A PipePro 304 is shown in example. See welding generator Owner’s Manual for
information on using remote controls with your unit.
Set Desired Process
In Example:
Process = Stick (Electrode Hot)
Front Panel Amperage Setting = About 185 A (Midrange)
Remote Control Amperage Range = 5 to 185 A
Set Desired Maximum
Amperage For Application
Min
5 A DC
Adjust remote control to increase
or decrease weld output.
Max
185 A DC
Example Of Remote Voltage Control
Set Switch
Set Desired Process
In Example:
Process = MIG
Front Panel Voltage Setting = Any Position
Remote Control Voltage Range = 10 to 34 V DC
Control Position Does Not
Matter In MIG
Min
10 V DC
Adjust remote control to increase
or decrease weld output.
Max
34 V DC
OM-2808 Page 2
Ref. 189 438-A

5. Parts List
Y Read warning label on remote control before servicing.
2
10
1
3
. Hardware is common and
not available unless listed.
9
6
4
7
5
8
Figure 1. Complete Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Complete Assembly
1 196085 Box, Outlet/Control Weatherable W/Covers & Hardware 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 151981 Rcpt, Str Dx Grd 2p3w 20a 125v *5−20r Gfi 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 035897 Pot, Cp Std Slot 1t 2. W 1k Linear 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 097924 Knob, Pointer 1.625 Dia X .250 Id W/Set Screwsplstc 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 209603 Cable,Set Spliced W/Molded Jacket 6 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 196088 Plate, Ident Control Rating 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 134734 Conn, Circ Ms/Cpc 14pin Size 20 Plug Cable Pushin 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
134731 Conn, Circ Ms/Amp Pin Pushin 14−18ga .110−.150 Insu 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 079739 Conn, Circ Cpc Clamp Str Rlf Size 17−20 .703od 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 196087 Plug, Str Grd 2p3w 15a 125v Nema 5−15 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 196003 Label, warning electric shock can kill 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
802 426-C
Quantity
OM-2808 Page 4