Miller LDR-14 REMOTE CONTROL (043955) Owners manual

Page 1
OWNER’S MANUAL
For LDR-14 Remote Control 043 955
OM-2808 196 319H
May 2005
WARNING
1. Typical Connection
1
READ SAFETY BLOCKS in welding power source Owner’s Manual before proceeding.
3
1 LDR-14 Remote Control 2 Remote 14 Receptacle
3 120 V AC Auxiliary Power Receptacle Insert LDR-14 remote 14 plug into match-
ing 14-socket receptacle on welding gener­ator. Tighten collar.
2. Using LDR-14 120 V AC Receptacle
2
802 173-K
Insert LDR-14 auxiliary power plug into matching 120 V AC receptacle on welding generator.
1 120 V 20 A AC GFCI
1
Receptacle
Receptacle supplies 60 Hz single­phase power at weld/power speed. Maximum output from receptacle equals maximum output from cor­responding receptacle on welding generator.
Overload protection is provided by the corresponding ac receptacle circuit breaker on the welding gen­erator.
If a ground fault is detected, the LDR-14 GFCI Reset button pops out and the receptacle does not work. Check for faulty tools plugged in receptacle. Press but­ton to reset GFCI receptacle and resume operation.
. At least once a month, run en-
gine at weld/power speed and press test button to verify GFCI is working properly.
Page 2
3. Combination Remote Amperage/Voltage Control
NOTE
Example Of Combination Front Panel And Remote Amperage Control
Set Switch
A PipePro 304 is shown in example. See welding generator Owner’s Manual for information on using remote controls with your unit.
Set Desired Process
In Example: Process = Stick (Electrode Hot) Front Panel Amperage Setting = About 185 A (Midrange) Remote Control Amperage Range = 5 to 185 A
Set Desired Maximum
Amperage For Application
Min 5 A DC
Adjust remote control to increase
or decrease weld output.
Max
185 A DC
Example Of Remote Voltage Control
Set Switch
Set Desired Process
In Example: Process = MIG Front Panel Voltage Setting = Any Position Remote Control Voltage Range = 10 to 34 V DC
Control Position Does Not
Matter In MIG
Min 10 V DC
Adjust remote control to increase
or decrease weld output.
Max
34 V DC
OM-2808 Page 2
Ref. 189 438-A
Page 3
4. Wiring Diagram
221 070−B
OM-2808 Page 3
Page 4
5. Parts List
Y Read warning label on remote control before servicing.
2
10
1
3
. Hardware is common and
not available unless listed.
9
6
4
7
5
8
Figure 1. Complete Assembly
Item
No.
Dia.
Mkgs.
Part
No.
Description
Complete Assembly
1 196085 Box, Outlet/Control Weatherable W/Covers & Hardware 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 151981 Rcpt, Str Dx Grd 2p3w 20a 125v *5−20r Gfi 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 035897 Pot, Cp Std Slot 1t 2. W 1k Linear 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 097924 Knob, Pointer 1.625 Dia X .250 Id W/Set Screwsplstc 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 209603 Cable,Set Spliced W/Molded Jacket 6 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 196088 Plate, Ident Control Rating 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 134734 Conn, Circ Ms/Cpc 14pin Size 20 Plug Cable Pushin 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
134731 Conn, Circ Ms/Amp Pin Pushin 1418ga .110−.150 Insu 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 079739 Conn, Circ Cpc Clamp Str Rlf Size 17−20 .703od 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 196087 Plug, Str Grd 2p3w 15a 125v Nema 515 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 196003 Label, warning electric shock can kill 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .