Miller Electric ICE-12C, 125C User Manual

0 (0)
Miller Electric ICE-12C, 125C User Manual

Visit our website at

www.MillerWelds.com

OM-2248

213 990E

2007−02

Processes

Air Plasma Cutting

and Gouging

Description

Air Plasma Cutter

SpectrumR125C

And ICE-12C Torch

File: Plasma Cutters

Miller is the first welding equipment manufacturer in the U.S.A. to be registered to the ISO 9001:2000 Quality System Standard.

From Miller to You

Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way.

That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy.

Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929.

This Owner’s Manual is designed to help you get the most out of your Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite.

We’ve made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you figure out what the problem is. The parts list will then help you to decide the exact part you may need to fix the problem. Warranty and service information for your particular model are also provided.

Miller Electric manufactures a full line

of welders and welding related equipment. For information on other quality Miller

products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. To locate your nearest distributor or service agency call 1-800-4-A-Miller, or visit us at www.MillerWelds.com on the web.

Mil_Thank 2005−04

Working as hard as you do − every power source from Miller is backed by the most hassle-free warranty in the business.

TABLE OF CONTENTS

SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-2. Plasma Arc Cutting Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1-4. California Proposition 65 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1-5. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1-6. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2-1.

Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

2-2. Dangers liés au coupage à l’arc au plasma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement

 

 

et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

2-4.

Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

2-5.

Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

SECTION 3 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

3-1.

Symbols And Definitions For Nameplate And Serial Number/Rating Label . . . . . . . . . . . . . . . . . . . . . .

9

SECTION 4 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

4-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4-2. Specifications For Torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4-3. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4-4. Torch Dimensions And Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

4-5. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

4-6. Connecting Work Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

4-7. Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

SECTION 5 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

5-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

5-2. Cutting Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

5-3. Trigger Safety Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

5-4. Sequence Of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

SECTION 6 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

6-1.

Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

6-2. Overload Protection: Trouble Light And Checking Shield Cup Shutdown System . . . . . . . . . . . . . . . . .

17

6-3. Torch And Work Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

6-4.

Checking/Replacing Retaining Cup, Tip, And Electrode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

6-5.

Troubleshooting Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

6-6.

Troubleshooting Torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

SECTION 7 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

SECTION 8 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24

OPTIONS AND ACCESSORIES

 

WARRANTY

 

SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING

pom _4/05

Y Warning: Protect yourself and others from injury — read and follow these precautions.

1-1. Symbol Usage

Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.

Y Marks a special safety message.

. Means “Note”; not safety related.

1-2. Plasma Arc Cutting Hazards

YThe symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-5. Read and follow all Safety Standards.

YOnly qualified persons should install, operate, maintain, and repair this unit.

YDuring operation, keep everybody, especially children, away.

CUTTING can cause fire or explosion.

Hot metal and sparks blow out from the cutting arc. The flying sparks and hot metal, hot workpiece, and hot equipment can cause fires and burns. Check and be sure the area is safe before doing any cutting.

DRemove all flammables within 35 ft (10.7 m) of the cutting arc. If this is not possible, tightly cover them with approved covers.

DDo not cut where flying sparks can strike flammable material.

DProtect yourself and others from flying sparks and hot metal.

DBe alert that sparks and hot materials from cutting can easily go through small cracks and openings to adjacent areas.

DWatch for fire, and keep a fire extinguisher nearby.

DBe aware that cutting on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side.

DDo not cut on closed containers such as tanks or drums.

DConnect work cable to the work as close to the cutting area as practical to prevent cutting current from traveling long, possibly unknown paths and causing electric shock, sparks, and fire hazards.

DDo not use plasma cutter to thaw frozen pipes.

DNever cut containers with potentially flammable materials inside − they must be emptied and properly cleaned first.

DDo not cut in atmospheres containing explosive dust or vapors.

DDo not cut pressurized cylinders, pipes, or vessels.

DDo not cut containers that have held combustibles.

DWear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap.

DDo not locate unit on or over combustible surfaces.

DRemove any combustibles, such as a butane lighter or matches, from your person before doing any cutting.

DFollow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B for hot work and have a fire watcher and extinguisher nearby.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. The torch and work circuit are electrically live whenever the output is on. The input power circuit and machine internal circuits are also live when power is on. Plasma arc cutting requires

higher voltages than welding to start and maintain the arc (200 to 400 volts dc are common), but also uses torches designed with safety interlock systems which turn off the machine when the shield cup is loosened or if tip touches electrode inside the nozzle. Incorrectly installed or improperly grounded equipment is a hazard.

This group of symbols means Warning! Watch Out! possible

ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards.

DDo not touch live electrical parts.

DWear dry, hole-free insulating gloves and body protection.

DInsulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.

DDo not touch torch parts if in contact with the work or ground.

DTurn off power before checking, cleaning, or changing torch parts.

DDisconnect input power before installing or servicing this equipment. Lockout/tagout input power according to OSHA CFR 1910.147 (see Safety Standards).

DProperly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.

DCheck and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet − always verify the supply ground.

DWhen making input connections, attach proper grounding conductor first.

DFrequently inspect input power cord for damage or bare wiring − replace cord immediately if damaged − bare wiring can kill.

DTurn off all equipment when not in use.

DInspect and replace any worn or damaged torch cable leads.

DDo not wrap torch cable around your body.

DGround the workpiece to a good electrical (earth) ground if required by codes.

DUse only well-maintained equipment. Repair or replace damaged parts at once.

DWear a safety harness if working above floor level.

DKeep all panels and covers securely in place.

DDo not bypass or try to defeat the safety interlock systems.

DUse only torch(es) specified in Owner’s Manual.

DKeep away from torch tip and pilot arc when trigger is pressed.

DClamp work cable with good metal-to-metal contact to workpiece (not piece that will fall away) or worktable as near the cut as practical.

DInsulate work clamp when not connected to workpiece to prevent contact with any metal object.

ELECTRIC SHOCK can kill.

SIGNIFICANT DC VOLTAGE exists in inverter power sources AFTER the removal of input power.

DTurn Off unit, disconnect input power, check voltage on input capacitors, and be sure it is near zero (0) volts before touching any parts. Check capacitors according to instructions in Maintenance Section of Owner’s Manual or Technical Manual before touching any parts.

OM-2248 Page 1

EXPLODING PARTS can injure.

DOn inverter power sources, failed parts can explode or cause other parts to explode when

power is applied. Always wear a face shield and long sleeves when servicing inverters.

FLYING SPARKS can cause injury.

Sparks and hot metal blow out from the cutting arc.

Chipping and grinding cause flying metal.

DWear approved face shield or safety goggles with side shields.

DWear proper body protection to protect skin.

DWear flame-resistant ear plugs or ear muffs to prevent sparks from entering ears.

ARC RAYS can burn eyes and skin.

Arc rays from the cutting process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.

DWear face protection (helmet or shield) with a proper shade of filter lenses to protect your face and eyes when cutting or watching. ANSI

Z49.1 (see Safety Standards) suggests a No. 9 shade (with No. 8 as minimum) for all cutting currents less than 300 amperes. Z49.1 adds that lighter filter shades may be used when the arc is hidden by the workpiece. As this is normally the case with low current cutting, the shades suggested in Table 1 are provided for the operator’s convenience.

DWear approved safety glasses with side shields under your helmet or shield.

DUse protective screens or barriers to protect others from flash, glare and sparks; warn others not to watch the arc.

DWear protective clothing made from durable, flame-resistant material (leather, heavy cotton, or wool) and foot protection.

Table 1. Eye Protection For Plasma Arc Cutting

Current Level In Amperes

Minimum Shade Number

Below 20

#4

20 − 40

#5

40 − 60

#6

60 − 80

#8

NOISE can damage hearing.

Prolonged noise from some cutting applications can damage hearing if levels exceed limits specified by

OSHA (see Safety Standards).

DUse approved ear plugs or ear muffs if noise level is high.

DWarn others nearby about noise hazard.

FUMES AND GASES can be hazardous.

Cutting produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use local forced ventilation at the arc to remove cutting fumes and gases.

DIf ventilation is poor, wear an approved air-supplied respirator.

DRead and understand the Material Safety Data Sheets (MSDSs) and the manufacturer’s instruction for metals to be cut, coatings, and cleaners.

DWork in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Fumes from cutting and oxygen depletion can alter air quality causing injury or death. Be sure the breathing air is safe.

DDo not cut in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not cut on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the cutting area, the area is well ventilated, and while wearing an air-supplied respirator.

The coatings and any metals containing these elements can give off toxic fumes when cut.

DDo not cut containers with toxic or reactive materials inside or containers that have held toxic or reactive materials − they must be emptied and properly cleaned first.

PLASMA ARC can cause injury.

The heat from the plasma arc can cause serious burns. The force of the arc adds greatly to the burn hazard. The intensely hot and powerful arc can quickly cut through gloves and tissue.

DKeep away from the torch tip.

DDo not grip material near the cutting path.

DThe pilot arc can cause burns − keep away from torch tip when trigger is pressed.

DWear proper flame-retardant clothing covering all exposed body areas.

DPoint torch away from your body and toward work when pressing the torch trigger − pilot arc comes on immediately.

DTurn off power source and disconnect input power before disassembling torch or changing torch parts.

DUse only torch(es) specified in the Owner’s Manual.

CYLINDERS can explode if damaged.

Gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of metalworking processes, be sure to treat them carefully.

DProtect compressed gas cylinders from excessive heat, mechanical shocks, physical damage, slag, open flame, sparks, and arcs.

DInstall and secure cylinders in an upright position by chaining them to a stationary support or equipment cylinder rack to prevent falling or tipping.

DKeep cylinders away from any cutting or other electrical circuits.

DNever allow electrical contact between a plasma arc torch and a cylinder.

DNever cut on a pressurized cylinder − explosion will result.

DUse only correct gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and associated parts in good condition.

DTurn face away from valve outlet when opening cylinder valve.

DKeep protective cap in place over valve except when cylinder is in use or connected for use.

DUse the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders.

DRead and follow instructions on compressed gas cylinders, associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards.

OM-2248 Page 2

1-3. Additional Symbols For Installation, Operation, And Maintenance

HOT PARTS can cause severe burns.

DDo not touch hot parts bare handed.

DAllow cooling period before working on torch.

DTo handle hot parts, use proper tools and/or wear heavy, insulated welding gloves and clothing to prevent burns.

FALLING UNIT can cause injury.

DUse lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories.

DUse equipment of adequate capacity to lift unit.

DIf using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.

MOVING PARTS can cause injury.

DKeep away from moving parts such as fans.

DKeep all doors, panels, covers, and guards closed and securely in place.

DHave only qualified persons remove doors, panels, covers, or guards for maintenance as necessary.

DReinstall doors, panels, covers, or guards when maintenance is finished and before reconnecting input power.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servicing unit.

DUse only genuine Miller/Hobart replacement parts.

FLYING METAL can injure eyes.

DWear safety glasses with side shields or face shield.

MAGNETIC FIELDS can affect pacemakers.

DPacemaker wearers keep away.

DWearers should consult their doctor before going near plasma arc cutting operations.

FIRE OR EXPLOSION hazard.

D Do not locate unit on, over, or near combustible surfaces.

D Do not install unit near flammables.

DDo not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.

STATIC (ESD) can damage PC boards.

D Put on grounded wrist strap BEFORE handling boards or parts.

D Use proper static-proof bags and boxes to store, move, or ship PC boards.

H.F. RADIATION can cause interference.

DHigh frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment.

DHave only qualified persons familiar with electronic equipment perform this installation.

DThe user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.

DIf notified by the FCC about interference, stop using the equipment at once.

DHave the installation regularly checked and maintained.

DKeep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.

OVERUSE can cause OVERHEATING.

DAllow cooling period; follow rated duty cycle.

DReduce amperage (thickness) or reduce duty cycle before starting to cut again.

EXPLODING HYDROGEN hazard.

DWhen cutting aluminum underwater or with the water touching the underside of the aluminum, free hydrogen gas may collect under the workpiece.

D See your cutting engineer and water table instructions for help.

ARC CUTTING can cause interference.

DElectromagnetic energy can interfere with sensitive electronic equipment such as computers and computer-driven equipment such as robots.

DTo reduce possible interference, keep cables as short as possible, close together, and down low, such as on the floor.

DLocate cutting operation 100 meters from any sensitive electronic equipment.

DBe sure this cutting power source is installed and grounded according to this manual.

DIf interference still occurs, the user must take extra measures such as moving the machine, using shielded cables, using line filters, or shielding the work area.

1-4. California Proposition 65 Warnings

YWelding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)

YBattery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

For Gasoline Engines:

YEngine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

For Diesel Engines:

YDiesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.

OM-2248 Page 3

1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Practices for Plasma Arc Cutting, American Welding Society Standard AWS C5.2, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American

Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202.

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018.

Cutting And Welding Processes, NFPA Standard 51B, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Standard for Fire Prevention During Welding, Cutting, and Other Hot

Work, NFPA Standard 51B, from National Fire Protection Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone: 617−770−3000,website: www.nfpa.org).

OSHA, Occupational Safety and Health Standards for General Industry, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there are 10 Regional Offices−−phone for Region 5, Chicago, is 312−353−2220,website: www.osha.gov).

1-6. EMF Information

Considerations About Welding Or Cutting And The Effects Of Low

Frequency Electric And Magnetic Fields

Welding or cutting current, as it flows through the welding or cutting cables, will cause electromagnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power-frequency electric and magnetic fields is a humanhealth hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep cutting power source and cables as far away from operator as practical.

5.Connect work clamp to workpiece as close to the cut as possible.

About Pacemakers:

Pacemaker wearers consult your doctor before welding/cutting or going near welding/cutting operations. If cleared by your doctor, then following the above procedures is recommended.

OM-2248 Page 4

SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION

pom_fre 5/04

2-1. Signification des symboles

Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives.

Y Identifie un message de sécurité particulier.

. Signifie NOTA ; n’est pas relatif à la sécurité.

Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles et aux directives ci-dessous afin de connaître les mesures à prendre pour éviter tout danger.

2-2. Dangers liés au coupage à l’arc au plasma

YLes symboles présentés ci-après sont utilisés tout au long du présent manuel pour attirer votre attention et identifier les risques de danger. Lorsque vous voyez un symbole, soyez vigilant et suivez les directives mentionnées afin d’éviter tout danger. Les consignes de sécurité présentées ci-après ne font que résumer l’information contenue dans les normes de sécurité énumérées à la section 2-4. Veuillez lire et respecter toutes ces normes de sécurité.

YL’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées.

YAu cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants.

LE COUPAGE présente un risque de feu ou d’explosion.

Des particules de métal chaud et des étincelles peuvent jaillir de la pièce au moment du coupage. Les étincelles et le métal chaud, la pièce à couper chauffée et l’équipement chaud peuvcnt causer un

feu ou des brûlures. Avant de commencer à travailler, assurez-vous que l’endroit est sécuritaire.

DProtégez−vous, ainsi que toute autre personne travaillant sur les lieux, contre les étincelles et le métal chaud.

DNe coupez pas dans un endroit où des étincelles pourraient atteindre des matières inflammables.

DDéplacez toute matière inflammable se trouvant à l’intérieur d’un périmètre de 10,7 m (35 pi) de la pièce à couper. Si cela est impossible, vous devez les couvrir avec des housses approuvées et bien ajustées.

DAssurez−vous qu’aucune étincelle ni particule de métal ne peut se glisser dans de petites fissures ou tomber dans d’autres pièces.

DAfin d’éliminer tout risque de feu, soyez vigilant et gardez toujours un extincteur à la portée de la main.

DSi vous coupez sur un plafond, un plancher ou une cloison, soyez conscient que cela peut entraîner un feu de l’autre côté.

DNe coupez pas sur un contenant fermé tel qu’un réservoir ou un bidon.

DFixez le câble de masse sur la pièce à couper, le plus près possible de la zone à couper afin de prévenir que le courant de coupage ne prenne une trajectoire inconnue ou longue et ne cause ainsi une décharge électrique ou un feu.

DNe coupez jamais des contenants qui peuvent contenir des matières inflammables. Vous devez en premier lieu les vider et les nettoyer convenablement.

DNe coupez pas dans un endroit où l’atmosphère risque de contenir de la poussière ou des vapeurs explosives.

DNe coupez pas de bouteilles, de tuyaux ou de contenants pressurisés.

DNe coupez pas de contenants qui ont déjà reçu des combustibles.

DPortez des vêtements de protection exempts d’huile tels que des gants en cuir, une veste résistante, des pantalons sans revers, des bottes et un casque.

DNe placez pas le poste sur une surface combustible ou au−dessus de celle−ci.

DAvant le coupage, retirez tout combustible de vos poches, par exemple un briquet au butane ou des allumettes.

UNE DÉCHARGE ÉLECTRIQUE peut entraîner la mort.

Le fait de toucher à une pièce électrique sous tension peut donner une décharge fatale ou entraîner des brûlures graves. Le chalumeau et le circuit de masse sont automatiquement actifs lorsque le

poste est sous tension. L’alimentation d’entrée et les circuits internes de l’appareil le sont également. Le coupage au plasma d’arc exige des tensions plus élevées que le soudage pour amorcer et maintenir l’arc (souvent de 200 à 400 V CC), c’est pourquoi on fait appel à des chalumeaux conçus avec un système de verrouillage sécuritaire qui met l’appareil hors tension lorsque la capsule anti−feu est desserrée ou si le tube touche l’électrode à l’intérieur de la buse. Un poste incorrectement installé ou inadéquatement mis à la terre constitue un danger.

DNe touchez pas aux pièces électriques sous tension.

DPortez des gants isolants et des vêtements de protection secs et sans trous.

DIsolez−vous de la pièce à couper et du sol en utilisant des housses ou des tapis assez grands afin d’éviter tout contact physique avec la pièce à couper ou le sol.

DNe touchez pas aux pièces du chalumeau si vous êtes en contact avec la pièce à couper ou le sol.

DMettez l’appareil hors tension avant d’effectuer la vérification, le nettoyage ou le changement d’une pièce du chalumeau.

DCoupez l’alimentation d’entrée avant d’installer l’appareil ou d’effectuer l’entretien. Verrouillez ou étiquetez la sortie d’alimentation selon la norme OSHA 29 CFR 1910.147 (reportez−vous aux Principales normes de sécurité).

DInstallez le poste correctement et mettez-le à la terre convenablement selon les consignes du manuel de l’opérateur et les normes nationales, provinciales et locales.

DAssurez−vous que le fil de terre du cordon d’alimentation est correctement relié à la borne de terre dans la boîte de coupure ou que la fiche du cordon est branchée à une prise correctement mise à la terre − vous devez toujours vérifier la mise à la terre.

DAvant d’effectuer les connexions d’alimentation, vous devez relier le bon fil de terre.

DVérifiez fréquemment le cordon d’alimentation afin de vous assurer qu’il n’est pas altéré ou à nu, remplacez−le immédiatement s’il l’est. Un fil à nu peut entraîner la mort.

DL’équipement doit être hors tension lorsqu’il n’est pas utilisé.

DVérifiez et remplacez les cosses du câble du chalumeau si elles sont usées ou altérées.

DLe câble du chalumeau ne doit pas s’enrouler autour de votre corps.

DSi les normes le stipulent, la pièce à couper doit être mise à la terre.

DUtilisez uniquement de l’équipement en bonne condition. Réparez ou remplacez immédiatement toute pièce altérée.

DPortez un harnais de sécurité si vous devez travailler au−dessus du sol.

DAssurez−vous que tous les panneaux et couvercles sont correctement en place.

DN’essayez pas d’aller à l’encontre des systèmes de verrrouillage de sécurité ou de les contourner.

DUtilisez uniquement le ou les chalumeaux recommandés dans le manuel de l’opérateur.

DN’approchez pas le tube du chalumeau et l’arc pilote lorsque la gâchette est enfoncée.

DLe câble de masse doit être pincé correctement sur la pièce à couper, métal contre métal (et non de telle sorte qu’il puisse se détacher), ou sur la table de travail le plus près possible de la ligne de coupage.

OM-2248 Page 5

DIsoler la pince de masse quand pas mis à la pièce pour éviter le contact avec tout objet métallique.

Il y a DU COURANT CONTINU IMPORTANT dans les convertisseurs après la suppression de l’alimentation électrique.

DArrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie entretien avant de toucher les pièces.

DÉCHARGES ÉLECTRIQUES potentiellement mortelles.

Les pièces internes des sources d’alimentation de l’inverseur ont DES CHARGES C.C. SIGNIFICATIVES même APRÈS coupure du courant d’alimentation.

DMettre l’unité hors tension, mesurer la tension des condensateurs d’entrée et s’assurer qu’elle est pratiquement nulle avant de toucher à l’une quelconque des pièces. Mesurer cette tension conformément aux directives énoncées à la section Entretien du manuel de l’utilisateur ou du manuel technique avant de toucher à l’une quelconque des pièces.

Risque de blessure en cas

D’EXPLOSION DES PIÈCES.

DMise sous tension, toute pièce défectueuse des sources d’alimentation de l’inverseur peut exploser ou faire exploser d’autres pièces. Pour entretenir les inverseurs, toujours porter un masque protecteur et un vêtement à manches longues.

LES ÉTINCELLES VOLANTES risquent de provoquer des blessures.

Le coupage plasma produit des étincelles et projections de métal à très haute température. Lorsque la pièce refroidit, du laitier peut se former.

DPortez une visière ou des lunettes de sécurité avec des écrans latéraux approuvées.

DPortez des vêtements de protection adéquats afin de protéger votre peau.

DAyez recours à des protège−tympans ou à un serre−tête ignifuges afin d’éviter que les étincelles n’entrent dans vos oreilles.

LES RAYONS D’ARC peuvent entraîner des brûlures aux yeux et à la peau.

Les rayons d’arc provenant du procédé de coupage produisent des rayons visibles et invisibles intenses (ultraviolets et infrarouges) qui peuvent entraîner des brûlures aux yeux et à la

peau.

DLorsque vous coupez ou regardez quelqu’un couper, portez un masque ou un écran facial avec le filtre approprié. La norme ANSI Z49.1 (reportez−vous aux Principales normes de sécurité) suggère d’utiliser un filtre de teinte nd 9 (nd 8 étant le minimum) pour tout travail de coupage faisant appel à un courant de moins de 300 A. On mentionne également dans la norme Z49.1 qu’un filtre plus faible peut être utilisé lorsque l’arc est caché par la pièce à couper. Comme cela est habituellement le cas pour les travaux de coupage à faible courant, les teintes énumérées au tableau 1 sont fournies à titre d’information pour l’opérateur.

DPorter des lunettes de sécurité à coques latérales sous votre casque ou écran facial.

DAyez recours à des écrans protecteurs ou à des rideaux pour protéger les autres contre les rayonnements et les éblouissements; prévenez toute personne sur les lieux de ne pas regarder l’arc.

DPortez des vêtements confectionnés avec des matières résistantes et ignifuges (cuir et laine) et des bottes de protection.

Tableau 1. Protection des yeux pour le coupage au plasma d’arc

Intensité de courant en ampères

Filtre de teinte (minimum)

Moins de 20

no. 4

20 − 40

no. 5

40 − 60

no. 6

60 − 80

no. 8

LE BRUIT peut endommager l’ouïe.

Certaines applications de coupage produisent un bruit constant, ce qui peut endommager l’ouïe si le niveau sonore dépasse les limites permises par l’OSHA (reportez−vous aux Principales normes de sécurité).

DUtilisez des protège−tympans ou un serre−tête antibruit si le niveau sonore est élevé.

DPrévenez toute personne sur les lieux du danger relié au bruit.

LES FUMÉES ET LES GAZ peuvent être dangereux.

Le coupage produit des vapeurs et des gaz. Respirer ces vapeurs et ces gaz peut être dangereux pour la santé.

DNe mettez pas votre tête au−dessus des vapeurs. Ne respirez pas ces vapeurs.

DSi vous êtes à l’intérieur au moment du coupage, ventilez la pièce ou ayez recours à une ventilation aspirante installée près de l’arc pour évacuer les vapeurs et les gaz.

DSi la ventilation est médiocre, utilisez un respirateur anti−vapeurs approuvé.

DVeuillez lire le Material Safety Data Sheets (MSDS) et les instructions du fabricant pour obtenir plus de renseignements sur les métaux à couper, les enrobages et les nettoyants.

DTravaillez dans un espace restreint uniquement s’il est bien ventilé ou si vous portez un respirateur anti−vapeurs. Les vapeurs causées par le coupage et l’épuisement de l’oxygène peuvent altérer la qualité de l’air et entraîner des blessures ou la mort. Assurez−vous que l’air ambiant est sain pour la santé.

DNe coupez pas dans un endroit près d’opérations de décapage, de nettoyage ou de vaporisation. La chaleur et les rayons d’arc peuvent réagir avec les vapeurs et former des gaz hautement toxiques et irritants.

DNe coupez pas des métaux enrobés tels que des métaux galvanisés, contenant du plomb ou de l’acier plaqué au cadmium, à moins que l’enrobage ne soit ôté de la surface du métal à couper, que l’endroit où vous travaillez ne soit bien ventilé, ou, si nécessaire, que vous ne portiez un respirateur anti−vapeurs. Les enrobages ou tous métaux qui contiennent ces éléments peuvent créer des vapeurs toxiques s’ils sont coupés.

DNe coupez pas de contenants qui renferment ou ont renfermés des matières toxiques ou réactives − vous devez en premier lieu les vider et les nettoyer convenablement.

LE PLASMA D’ARC peut entraîner des blessures.

La chaleur dégagée par le plasma d’arc peut entraîner de sérieuses brûlures. La force de l’arc est un facteur qui s’ajoute au danger de brûlures. La chaleur intense et la puissance de l’arc peuvent rapidement passer au travers de gants et de tissus.

DN’approchez pas le tube du chalumeau.

DNe saisissez pas la pièce à couper près de la ligne de coupage.

DL’arc pilote peut causer des brûlures − n’approchez pas le tube du chalumeau lorsque vous avez appuyé sur le gâchette.

DPortez des vêtements de protection adéquats qui recouvrent tout votre corps.

DNe pointez pas le chalumeau en direction de votre corps ni de la pièce à couper lorsque vous appuyez sur la gâchette − l’arc pilote s’allume automatiquement.

DMettez l’alimentation hors tension et débranchez le cordon d’alimentation avant de démonter le chalumeau ou de changer une pièce du chalumeau.

DUtilisez uniquement le ou les chalumeaux recommandés dans le manuel de l’opérateur.

OM-2248 Page 6

Loading...
+ 22 hidden pages