Side-by-Side Merging Kit

KSK 1002

This merging kit should be used for side-by-side installation of the following models:

K 18x1 SF, K 19x1 SF, K 18x3 SF, K 19x3 SF

F 14x1 SF, F 18x1 SF, F 19x1 SF F 14x3 SF, F 18x3 SF, F 19x3 SF

KF 18x1 SF, KF 19x1 SF, KF 18x3 SF, KF 19x3 SF

KWT 16x1 SF, KWT 16x3 SF

Side-by-side

. . . without partition

If the appliances are installed directly next to each other (without a partition), they need to be attached together. A heating mat must also be installed. This will help avoid condensation and prevent damages.

. . . with partition

The minimum thickness of the partition is 5/8" (16 mm).

If there is a partition with a thickness

from 5/8" (16 mm) to 6 5/16" (160 mm) between the adjacent appliances, then

each appliance should be individually installed within its own niche using the mounting accessories included.

In this case, you will only need the heating mat from the "Merging Kit" to avoid condensation and prevent damages.

Page 2 of 12

Product and Cut-out Dimensions

48” Side-by-Side Combination

F14X3 & K18X3

FOR PROUD INSTALLATION

24"

min.

 

293/4"

84"

3/4"

17

 

24 5/8"

O

48"

E

83 1/2" - 85 3/8"

10 1/4"

 

 

1 1/8"

Location Codes

E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear

O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less than 9" above finished floor

Notes

KSK1002 Merging kit must be used when combining units

All Installations must be done in accordance with local codes

3 1/2" - 5 3/8"

Page 3 of 12

Product and Cut-out Dimensions

48” Side-by-Side Combination

F14X3 & K18X3

FOR FLUSH INSTALLATION

25"

min.

 

293/4"

84"

3/4"

17

 

24 5/8"

O

48"

E

83 1/2" - 85 3/8"

10 1/4"

 

 

1 1/8"

Location Codes

E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear

O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less than 9" above finished floor

Notes

KSK1002 Merging kit must be used when combining units

All Installations must be done in accordance with local codes

Sides of adjoining cabinets should be filled (flush to frame) to insure proper fit and finish

3 1/2" - 5 3/8"

Page 4 of 12