MasterCool Refrigeration
Side-by-Side Merging Combinations
For SF Models
8mieleusa.com
Side-by-Side Merging Kit
KSK 1002
This merging kit should be used for side-by-side installation of the following models:
–K 18x1 SF, K 19x1 SF, K 18x3 SF, K 19x3 SF
–F 14x1 SF, F 18x1 SF, F 19x1 SF F 14x3 SF, F 18x3 SF, F 19x3 SF
–KF 18x1 SF, KF 19x1 SF, KF 18x3 SF, KF 19x3 SF
–KWT 16x1 SF, KWT 16x3 SF
Side-by-side
. . . without partition
If the appliances are installed directly next to each other (without a partition), they need to be attached together. A heating mat must also be installed. This will help avoid condensation and prevent damages.
. . . with partition
The minimum thickness of the partition is 5/8" (16 mm).
If there is a partition with a thickness
from 5/8" (16 mm) to 6 5/16" (160 mm) between the adjacent appliances, then
each appliance should be individually installed within its own niche using the mounting accessories included.
In this case, you will only need the heating mat from the "Merging Kit" to avoid condensation and prevent damages.
Page 2 of 12
Product and Cut-out Dimensions
48” Side-by-Side Combination
F14X3 & K18X3
FOR PROUD INSTALLATION
24" |
min. |
|
293/4"
84" |
3/4" |
17 |
|
|
24 5/8" |
O
48"
E |
83 1/2" - 85 3/8" |
|
10 1/4" |
||
|
||
|
1 1/8" |
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less than 9" above finished floor
Notes
•KSK1002 Merging kit must be used when combining units
•All Installations must be done in accordance with local codes
3 1/2" - 5 3/8"
Page 3 of 12
Product and Cut-out Dimensions
48” Side-by-Side Combination
F14X3 & K18X3
FOR FLUSH INSTALLATION
25" |
min. |
|
293/4"
84" |
3/4" |
17 |
|
|
24 5/8" |
O
48"
E |
83 1/2" - 85 3/8" |
|
10 1/4" |
||
|
||
|
1 1/8" |
Location Codes
E - 5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear
O - One (1) Standard NEMA 5-15 Duplex Outlet - locate less than 9" above finished floor
Notes
•KSK1002 Merging kit must be used when combining units
•All Installations must be done in accordance with local codes
•Sides of adjoining cabinets should be filled (flush to frame) to insure proper fit and finish
3 1/2" - 5 3/8"
Page 4 of 12