Miele DA252-3, DA 251, DA259-3 User Manual

0 (0)

Operating and installation instructions

Ventilation System

DA 251

DA 252-3

DA 259-3

To prevent accidents and machine damage, read these instructions before

UV

installation or use.

M.-Nr. 05 802 960

Table of Contents

IMPORTANT SAFETY INSTRUCTIONS

Functional description

Guide to the appliance

Operation

Turning on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Selecting the power level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Delayed Shut Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Turning off the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Turning the lighting on / off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Dimming the lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Indirect lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Grease filter timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Checking the grease filter timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Reprogramming the grease filter timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Cleaning and Care

Cleaning the casing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Grease filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Changing the light bulbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Indirect lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

After Sales Service

Installation instructions

Caring for the environment

Plywood backing

Installation accessories

Electrical data

Appliance dimensions and Installation Air extraction

Condensate trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

2

IMPORTANT SAFETY INSTRUCTIONS

Read these Operating Instructions carefully before installing or using the Ventilation System.

This appliance is intended for residential use only. Use the appliance only for its intended purpose. The manufacturer cannot be held responsible for damages caused by improper use of the hood.

This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage.

READ AND SAVE THESE

INSTRUCTIONS

CAUTION

For General Ventilating Use Only.

Do Not Use To Exhaust Hazardous

Or Explosive Materials And Vapors.

This appliance is designed to vent cooking smoke and odors only.

Be certain your appliance is properly installed and grounded by

a qualified technician.

To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician. The manufacturer can not be held responsible for damages caused by the lack, or inadequacy of, an effective grounding system.

Before connecting the appliance to the power supply make sure that

the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent machine damage. Consult a qualified electrician if in doubt.

Installation work and repairs should only be performed by a qualified

technician in accordance with all applicable codes and standards. Repairs and other work by unqualified persons could be dangerous and the manufacturer will not be held responsible.

3

IMPORTANT SAFETY INSTRUCTIONS

This equipment is not designed for maritime use or for use in mobile

installations such as caravans or aircraft. However, under certain conditions it may be possible for an installation in these applications. Please contact the nearest Miele dealer or the Technical Service Department with specific requirements.

Before servicing or cleaning the unit, switch power off at the service

panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means can not be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Before discarding an old appliance, unplug it from the

power supply and remove the power cord and any doors to prevent hazards.

Use

Do not allow children to play with or operate the appliance or its

controls. Supervise its use by the elderly or infirm.

Be careful when preparing a flambé beneath the hood.

Flames may be drawn up into the hood by the suction or grease filters may catch fire.

Never operate gas burners without pots.

Do not leave cooking surfaces unattended while in use.

Overheated food, oil and grease can catch fire.

Do not use the hood without the grease filters in place.

Clean the grease filters regularly. Dirty filters are a fire hazard.

Do not use a steam cleaner to clean the hood. Steam could penetrate electrical components and

cause a short circuit.

In areas subject to infestation by cockroaches or other pest, keep

the appliance and its surroundings clean at all times. Any damage caused by cockroaches or other pest will not be covered under warranty.

Always turn on the hood when using the cooktop to prevent

damage from condensation.

4

IMPORTANT SAFETY INSTRUCTIONS

, WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

Never leave surface units unattended at high settings.

Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings.

Always turn the hood “ON” when cooking at high heat or when

cooking flaming foods.

Clean ventilating fans frequently. Grease should not be allowed to

accumulate on the fan or filter.

Use proper pan size. Always use cookware appropriate for the size

of the surface element.

, WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal

tray, then turn off the burner.

BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,

EVACUATE AND CALL THE FIRE DEPARTMENT.

NEVER PICK UP A FLAMING PAN - You may be burned.

DO NOT USE WATER, including wet dishcloths or towels - a violent

steam explosion will result.

Use an extinguisher

ONLY if:

You know you have a Class ABC extinguisher, and you already know how to operate it.

The fire is small and contained in the area where it started.

The fire department is being called.

You can fight the fire with your back to an exit.

5

IMPORTANT SAFETY INSTRUCTIONS

Installation

, WARNING

To reduce the risk of fire only use metal ductwork.

When installing the hood, follow the recommended minimum safety

distances between a Miele cooktop and the hood:

22" (55 cm) above electric cooktops,

26" (65 cm) above gas cooktops,

26" (65 cm) above an open grill.

If local building codes require a greater safety distance, follow their requirement.

For non-Miele cooking appliances maintain the safety distances recommended by the appliance manufacturer in their instructions. If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance.

Be careful not to damage hidden electrical wiring or plumbing when

cutting or drilling into the wall or ceiling.

Do not use an extension cord to connect the appliance to electricity.

Extension cords do not guarantee the required safety of the appliance, (e.g. danger of overheating).

Do not install this hood over cooktops burning solid fuel.

Any fittings, sealant, or materials used to install the ductwork must be made of approved non-flammable

materials.

Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room ventilating ductwork. Seek professional advice before connecting

an exhaust hood vent to an existing, inactive chimney or vent flue.

Ducted fans must always be vented outdoors.

Make sure that the airflow in the room is sufficient for combustion

and exhausting of all non-electric heating appliances (water heaters, gas cooktops, gas ovens, etc.), otherwise backdrafts may occur. Follow the heating manufacturer’s guidelines and safety standards or those published by the National Fire Protection Association (NFPA), or the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE).

If in doubt, consult an experienced professional.

6

Functional description

The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filters and directed outside.

The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur. When the hood is turned on, the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside.

7

Miele DA252-3, DA 251, DA259-3 User Manual

Guide to the appliance

8

Guide to the appliance

a Chimney extension

b Chimney

c Canopy

d Grease filter

e Overhead lighting

f Indirect lighting

g Glass shelves

Each holds up to 8 lbs.

h Canopy storage surface

Max weight on entire surface not to exceed 17 lbs.

i Control panel

j Indirect lighting switch

k Light button

This button turns the light on and off and also dims the light.

The lighting can be used independently of the fan.

l On/Off button

m Fan power level buttons

Four fan speed selection.

n Delayed Shut Down

This button activates the Delayed Shut Down feature. The fan can be set to turn off automatically after either 5 or 15 minutes.

o Grease filter button

The indicator next to the grease filter button lights when the grease filters need to be cleaned. This button is also used:

to reset the grease filter timer after cleaning the grease filters (see "Cleaning and Care").

to show how long the grease filters have been in use (see "Operation / Grease filter timer").

to change the number of hours counted by the grease filter timer (see "Operation / Reprogramming the grease filter timer").

9

Operation

Turning on the fan

^ Press the On/Off button.

The fan runs at power level "2". The On/Off indicator lights.

Selecting the power level

^Use the _controls to select the desired power level.

&=increases the fan speed $=decreases the fan speed

Level "1" to "3" (green indicators) are usually sufficient for normal cooking.

Intensive setting

Level "4" (yellow indicator) should be used for a short period when frying or cooking food with a strong aroma.

Fan performance

The maximum air flow capacity is 625 cfm. Factors such as narrow duct diameter and bends will affect this value.

Level 1 operates at 40% capacity Level 2 operates at 60% capacity Level 3 operates at 80% capacity Level 4 operates at 100% capacity

Delayed Shut Down

If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes.

^Press the Delayed Shut Down button while the fan is still running.

Press once =

5 minute delay

 

(left indicator lights)

Press twice =

15 minute delay

 

(right indicator lights)

To cancel the Delayed Shut Down feature press the button again.

10

Loading...
+ 22 hidden pages