T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R
MGE UPS SYSTEMS
PowerServicesTM
TelPac
Installation manual
34003602EN/AB - Page 1
Page 2 - 34003602EN/AB
Introduction
Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
PowerServices TelPac has been designed with the utmost care.
It comes in 2 versions: card (ref. 66096) or external (ref. 66097 or 66098).
The card version can be installed by the customer or by an MGE UPS SYSTEMS After Sales Service technician. The external version can only be installed by a specialised MGE UPS SYSTEMS After Sales Service technician. We recommend you take time to read this manual to take full advantage of the many features of this product.
To discover the entire range of MGE UPS SYSTEMS products, visit our Web site at www.mgeups.com or contact your nearest MGE UPS SYSTEMS representative.
Environment
MGE UPS SYSTEMS pays great attention to the environmental impact of its products during the design and manufacture stages and through to the end of its life cycle.
MGE UPS SYSTEMS products comply with the strictest regulations.
They do not contain CFCs or HCFCs.
Recycling of packaging
Packaging has been designed to be recycled. Please make sure it is correctly recycled (in compliance with applicable regulations).
Recycling of products at the end of their life cycle
MGE UPS SYSTEMS undertakes to recycle all recovered products at the end of their life cycle in installations complying with applicable regulations. Please contact our sales office.
See the environment section on our Web site at www.mgeups.com.
Special precautions
If the card or external unit must be stored prior to installation, always store in a dry location.
Storage temperature range: -10ºC to +70ºC.
34003602EN/AB - Page 3
Foreword
EMC compatibility
The PowerServices TelPac card and external versions comply with the following standards, on condition that they are installed and used in compliance with their intended use and manufacturer’s instructions:
Safety standards for IT equipment: EN 60950/A11 (1998).
EMC: EN 61000-6-2 (1999), EN 61000-6-3 (2002).
The PowerServices TelPac card and external versions comply with the following European directives:
|
Low voltage: |
73/23/EEC and 93/68/EEC. |
|
EMC: |
89/336/EEC and 93/68/EEC. |
Federal Communication Commission (FCC) statement
Part 15
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Part 68
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Radio and Telecommunications compatibility
The PowerServices TelPac card and external versions comply with the European R&TTE directive, on condition that they are installed and used in compliance with their intended use and manufacturer’s instructions.
Page 4 - 34003602EN/AB
Foreword
Modem compatibility and supported countries
The modem integrated in the PowerServices TelPac card is compatible with European standard CTR21 (01.98) in accordance with Council Decision 98/482/EC.
List of countries supported by the modem
Australia |
Denmark |
Ireland |
New Zealand |
South Africa |
|
Austria |
Finland |
Israel |
Netherlands |
Spain |
|
Belgium |
France |
Italy |
Norway |
Sweden |
|
Brazil |
Germany |
Japan |
Philippines |
Switzerland |
|
Bulgaria |
Greece |
Korea |
Poland |
Taiwan |
|
|
Hong Kong |
|
Portugal |
||
Canada |
Luxembourg |
United Kingdom |
|||
China |
Hungary |
Malaysia |
Russia |
||
United States |
|||||
Czechoslovakia |
India |
Mexico |
Singapore |
||
|
|||||
|
|
|
|
|
34003602EN/AB - Page 5
Foreword
Pictogram symbols
Important instructions that must always be followed.
Information and advice.
Visual indication.
Action.
UPS : Uninterruptible Power System.
The conventions used to represent indicator lights in the illustrations are as follows:
Indicator off.
Indicator on.
Flashing Indicator.
Page 6 - 34003602EN/AB
Contents
1.Presentation
1.1 |
Unpacking and checking the contents |
.......................................................................................................... 9 |
1.2 |
Overview ......................................................................................................................................................... |
10 |
1.3 |
Functions ...................................................................................................................................................... |
11 |
1.4 |
Technical data sheet....................................................................................................................................... |
12 |
1.5 |
Indicator lights ................................................................................................................................................ |
13 |
2.Installation
2.1 |
Procedure ........................................................................................................................................................ |
14 |
2.2 |
Preliminary check ........................................................................................................................................... |
14 |
2.3 |
The various installation types ....................................................................................................................... |
15 |
2.4 |
Recommendations ......................................................................................................................................... |
16 |
2.5 |
Fitting the warning label ................................................................................................................................ |
16 |
2.6 |
Setting up the RS485 link .............................................................................................................................. |
18 |
|
General ............................................................................................................................................................. |
18 |
|
"Single-unit" type installation ............................................................................................................................ |
18 |
|
Impedance matching and bias settings ............................................................................................................ |
19 |
|
Configuring the shielding terminal .................................................................................................................... |
20 |
|
Configuring the RS485 card for Comet ............................................................................................................ |
21 |
|
Configuring the RAUZ card for Galaxy ............................................................................................................ |
22 |
2.7 |
Installing the PowerServices TelPac card .................................................................................................... |
23 |
2.8 |
Installation of the PowerServices TelPac external unit for Comet UPSs .................................................. |
24 |
2.9 |
Installing the PowerServices TelPac external unit for Galaxy UPSs ......................................................... |
26 |
2.10 |
Connecting contact type inputs .................................................................................................................... |
28 |
34003602EN/AB - Page 7
Contents
3. Maintenance |
|
3.1 Cable diagrams ............................................................................................................................................... |
30 |
Serial cable diagrams (ref. 34003618) ............................................................................................................. |
30 |
Modem cable (ref. 34003729) .......................................................................................................................... |
30 |
Comet link cable (ref. 34003747) ..................................................................................................................... |
30 |
Page 8 - 34003602EN/AB
1.1 Unpacking and checking the contents
PowerServices
Telpac
Installation and user manual
|
F |
C |
A |
|
|
|
Phone Settings JBUS / RS485 |
|
CD |
A 5V B R+ R- T+ T- |
D |
UPS |
PowerServices TelPac |
|
66096
G
MGE ATTENTION : Onduleur sous Teleservice |
|
MGEWARNING:ATTENTIONUPS: underOnduleurTeleservicesous leservice |
|
MGEWARNING:ATTENTIONUPS: underOnduleurTeleservicesous leservice |
|
Ne pas mettreWARNING:hors tensionUPSsansunderavoir Teleserviceau préalable |
E |
arrêtéNe lapaslignemettretéléphoniquehors tension sans avoir au préalable |
|
Do arrêténotNeswitchlapasligneoffmettrewithouttéléphoniquehorsfirsttensiondisconnectingsans avoir au préalable |
|
theDotelephonearrêténot switchlalineligneoff withouttéléphoniquefirst disconnecting |
|
theDotelephonenot switchlineoff without first disconnecting |
|
the telephone line |
|
B
Phone |
Settings |
JBUS / RS485 |
CD |
|
A 5V B R+ R- T+ T- |
UPS |
|
PowerServices TelPac |
PowerServices
Telpac
Installation and user manual
F
MGE ATTENTION : Onduleur sous Teleservice MGEWARNING:ATTENTIONUPS: underOnduleurTeleservicesous leservice
MGEWARNING:ATTENTIONUPS: underOnduleurTeleservicesous leservice Ne pas mettreWARNING:hors tensionUPSsansunderavoir Teleserviceau préalable arrêtéNe lapaslignemettretéléphoniquehors tension sans avoir au préalable
Do arrêténot switchla ligneoff withouttéléphoniquefirst disconnecting
Ne pas mettre hors tension sans avoir au préalable theDotelephonenot switchlineoff without first disconnecting
arrêté la ligne téléphonique theDotelephonenot switchlineoff without first disconnecting
the telephone line
A
C
66097, 66098
G
EI
H
J |
Phone |
Settings |
JBUS / RS485 |
H |
|
CD |
|
A 5V B R+ R- T+ T- |
|
D |
UPS |
|
PowerServices TelPac |
|
|
|
|
1. Presentation
Content of the card version
A:PowerServices TelPac communication card.
B:cover plate specifically designed for
Galaxy PW UPSs.
C:5m telephone cable equipped with RJ11 plugs.
D:2.5m serial communication cable used for configuration and maintenance operations.
E:3 warning labels.
F:this manual.
G:information form needed to activate Teleservice.
Content of the external version
A: PowerServices TelPac external communication unit with its fixing kit.
C:5m telephone cable equipped with RJ11 plugs.
D:2.5m serial communication cable.
E:3 warning labels.
F:this manual.
G:information form needed to activate Teleservice.
H:UPS link cable and fixing accessories.
I:cleaning kit.
J:plug-in 5V DC power adapter.
34003602EN/AB - Page 9