MDE 5KP Datasheet

Loading...
MDE 5KP Datasheet

MDE Semiconductor, Inc.

78-150 Calle Tampico, Unit 210, La Quinta, CA. U.S.A. 92253 Tel: 760-564-8656 • Fax: 760-564-2414

5KP SERIES

GLASS PASSIVATED JUNCTION TRANSIENT VOLTAGE SUPPRESSOR

VOLTAGE-5.0 TO 180 Volts

5000 Watt Peak Pulse Power

FEATURES

Glass passivated junction

5000W Peak Pulse Power capability on 10/1000 µs waveform

Glass passivated junction

Low incremental surge resistance

Excellent clamping capability

Repetition rate (duty cycle): 0.05%

Fast response time: typically less than

1.0ps from 0 volts to BV

Typical IR less than 1µA above 10V

MECHANICAL DATA

The devices listed in this document take the following physical form:

Diameter

Height

5KP TVS Cells: Assembled with 220mm Hex Die Max. Height 2.5mm, 0.100 Inch

Max. Dia 7.6mm, 0.300 inch

All dice are passivated either glass or SiO2

These cell TVS devices are specially designed for TVS modules and hybrid circuit applications. The benefit of this package is less space and easier assembly Users should be cautioned that the assembled modules must be properly protected to avoid the glass or Si02 passivated die damage.

DEVICES FOR BIPOLAR APPLICATIONS

For Bidirectional use C or CA Suffix for types 5KP5.0 thru types 5KP180 (e.g. 5KP5.0C, 5KP180CA) Electrical characteristics apply in both directions.

MAXIMUM RATINGS AND CHARACTERISTICS

Ratings at 25°C ambient temperature unless otherwise specified.

RATING

SYMBOL

VALUE

UNITS

Peak Pulse Power Dissipation on 10/1000 µs

Pppm

Minimum 5000

Watts

waveform (NOTE 1, Fig.1)

 

 

 

Peak Pulse Current of on 10/1000 µs waveform (Note 1,Fig 3)

Ippm

SEE TABLE 1

Amps

Steady State Power Dissipation at TL = 75°C

Pm(AV)

8.0

Watts

Lead lengths .375", 9.5mm (Note 2)

 

 

 

Peak Forward Surge Current, 8.3ms Single Half Sine-wave

IFSM

400

Amps

Superimposed on Rated Load, (JEDEC Method)(Note 3)

 

 

 

Operatings and Storage Temperature Range

Tj, Tstg

-55 +175

°C

NOTES:

 

 

 

1.Non-repetitive current pulse, per Fig.3 and derated above Ta=25 °C per Fig.2.

2.Mounted on Copper Pad area of 0.8x0.8" (20x20mm) per Fig.5.

3.8.3ms single half sine-wave, or equivalent square wave, Duty cycle=4 pulses per minutes maximum.

10/7/2002