DRYER SAFETY...........................................................................

2

INSTALLATION REQUIREMENTS..............................................

4

Tools and Parts.......................................................................

4

LOCATION REQUIREMENTS.....................................................

5

ELECTRIC DRYER POWER HOOKUP – CANADA ONLY.........

6

GAS DRYER POWER HOOKUP..................................................

7

INSTALL LEVELING LEGS..........................................................

9

MAKE GAS CONNECTION.........................................................

9

VENTING....................................................................................

10

Venting Requirements..........................................................

10

Plan Vent System..................................................................

11

Install Vent System...............................................................

12

CONNECT INLET HOSE (STEAM MODEL ONLY)...................

12

CONNECT VENT........................................................................

14

LEVEL DRYER...........................................................................

14

COMPLETE INSTALLATION CHECKLIST................................

15

DOOR REVERSAL (OPTIONAL)................................................

15

SÉCURITÉ DE LA SÉCHEUSE...................................................

23

EXIGENCES D’INSTALLATION..................................................

25

Outillage et pièces..............................................................

25

EXIGENCES D’EMPLACEMENT................................................

26

SÉCHEUSE ÉLECTRIQUE RACCORDEMENT À

 

L’ALIMENTATION ÉLECTRIQUE – CANADA SEULEMENT.....

27

RACCORDEMENT D’UNE SÉCHEUSE À GAZ.........................

28

INSTALLATION DES PIEDS DE NIVELLEMENT.......................

30

RACCORDEMENT AU GAZ.......................................................

30

ÉVACUATION..............................................................................

31

Exigences concernant l’évacuation..................................

31

Planification du système d’évacuation.............................

32

Installation du système d’évacuation...............................

34

RACCORDEMENT DU TUYAU D’ALIMENTATION

 

(MODÈLE À VAPEUR UNIQUEMENT).......................................

34

RACCORDEMENT DU CONDUIT D’ÉVACUATION..................

36

RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE..........................

36

ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION...........

37

INVERSION DE LA PORTE (FACULTATIF).................................

37

Para una version de estas instrucciones en español, visite www.Whirlpool.com

INSTALLATION NOTES

NOTES CONCERNANT L’INSTALLATION

Date of purchase: __________________________________

Date d’achat:______________________________________

Date of installation:_ ________________________________

Date d’installation:__________________________________

Installer: _________________________________________

Installateur:_______________________________________

Model number: ____________________________________

Numéro de modéle:_________________________________

Serial number:_____________________________________

Numéro de série:___________________________________

W11101336A W11101338A-SP

Whirlpool ywed72hedw, ymed8100dw, ymed8100dc, ymed7100dw, ymed7100dc Installation Instructions

DRYER SAFETY

2

WARNING:

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building, or area of all occupants.

Immediatelyinstructions. call your gas supplier from a neighbor’s phone. Follow the gas supplier’s

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by the State of Massachusetts.

Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.

A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Tools needed for all installations:

 

 

 

Flat-blade screwdriver

 

#2 Phillips screwdriver

 

 

 

 

 

 

1/4" and 5/16" nut driver

 

Level

(recommended)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tape measure

Pliers

Parts supplied (all models):

Leveling legs (4)

Parts package is located in dryer drum. Check that all parts are included.

NOTE: Do not use leveling legs supplied with dryer if installing with a pedestal or a stack kit.

Parts needed (steam models):

“Y” connector

 

Short inlet hose

 

 

 

 

 

 

 

 

 

 

Utility knife

Tin snips (new vent installations)

 

 

 

 

 

 

 

 

Caulking gun and compound

Adjustable wrench that opens to

(new vent installations)

1" (25 mm) or hex-head socket wrench

Tools needed for gas installations:

Rubber washer

Inlet hose

Parts needed (not supplied with dryer): ■■Vent clamps

■■Vent elbows and vent work

Additional parts may be required, depending in your installation. Check local codes. Check existing electrical supply and venting. Read “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Optional Equipment: (Not supplied with dryer)

Refer to your Use and Care Guide for information about accessories available for your dryer.

8" or 10" pipe wrench

8" or 10" adjustable wrench

 

(for gas connections)

 

 

Pipe-joint compound resistant to propane gas

4

LOCATION REQUIREMENTS

DRYER DIMENSIONS

Front view:

27" (686 mm)

383/4" Min.

(984 mm)

39" Max. (990 mm)

You will need:

■■A location allowing for proper exhaust installation. See “Venting Requirements.”

■■A separate 15or 20-amp circuit for a gas dryer or 30-amp circuit for an electric dryer.

■■If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”

■■Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance.

■■Cold water faucets located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20–120 psi (138–827 kPa). You may use the water supply for your washer using the necessary parts as noted (which you will need to purchase).

■■Level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.

■■For garage installation, place dryer at least 18" (460 mm) above floor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.

■■The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

IMPORTANT: Do not operate, install, or store dryer where

it will be exposed to water, weather, or at temperatures below 40°F (4°C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times.

Side view:

*Approx. measurement

Back view:

61/4"

(159 mm)

 

 

 

297/8"*

 

Water inlet

(759 mm)

53/4"*

(Steam Models Only)

 

Vent

 

31/2"*

(146 mm)

 

 

 

 

(89 mm)

 

Gas

 

 

 

 

 

61/8"*

3/4"*

14

3

(156 mm)

(18 mm)

/8"

 

(365 mm)

 

 

 

 

253/4"

 

 

 

(654 mm)

 

*Approx. measurement

 

 

 

NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”

5

Installation Clearances

For each arrangement, consider allowing more space for ease of installation and servicing, as well as spacing for companion appliances and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.

Installation spacing for recessed area or closet installation

All dimensions show recommended and minimum spacing allowed.

■■Additional spacing should be considered for ease of installation and servicing.

■■Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line.

■■Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

■■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

■■Companion appliance spacing should also be considered.

Recommended installation clearances (dryer only):

 

3"

 

18" min.

(76 mm)

48 in.2 min.

(457 mm)

 

 

(310 cm2)

 

 

 

24 in.2 min.

5"

*

 

(155 cm2)

 

3"

(127 mm)

 

 

(76 mm)

 

 

 

 

1"

*

1"

 

(25 mm)

 

(25 mm)

 

 

*0" (0 mm) spacing is allowed.

Mobile home – Additional installation requirements:

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR,

Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

■■Metal exhaust system hardware, available for purchase from your dealer. For further information, see the “Assistance or Service” section in your Use and Care Guide.

■■Special provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.

For mobile home installation of gas dryers:

■■Mobile Home Installation Hold-Down Kit Part Number 346764 is available to order. For further information, see the “Assistance or Service” section in your Use and Care Guide.

ELECTRIC DRYER POWER HOOKUP – CANADA ONLY

ELECTRICAL REQUIREMENTS

It is your responsibility:

■■To contact a qualified electrical installer.

■■To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code, C22.1 – latest edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

■■To supply the required 4-wire, single-phase, 120-/240-volt, 60 Hz, AC-only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

■■This dryer is equipped with a UL-listed

or CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall receptacle is

within reach of dryer’s final location. 4-wire receptacle (14-30R)

6

If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 8529008.

For further information, please reference service numbers located in “Assistance or Service” section of your Use and Care Guide.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.

SAVE THESE INSTRUCTIONS

GAS DRYER POWER HOOKUP

ELECTRICAL REQUIREMENTS

■■120-volt, 60 Hz, AC-only, 15or 20amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a quali•ed electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not •t the outlet, have a proper outlet installed by a quali•ed electrician.

SAVE THESE INSTRUCTIONS

GAS SUPPLY REQUIREMENTS

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line. Install a shut-off valve.

Securely tighten all gas connections.

If connected to propane, have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

GAS TYPE

Natural Gas:

This dryer is equipped for use with natural gas. It is designcertified by UL for use with propane gas with appropriate conversion.

■■Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your Use and Care Guide.

Propane Gas Conversion:

IMPORTANT: Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.

7

GAS SUPPLY LINE

Option 1 (Recommended Method)

Flexible stainless steel gas connector:

■■If local codes permit, use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking.

Option 2 (Alternate Method)

Approved aluminum or copper tubing:

■■Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer. See illustration.

■■1/2" IPS pipe is recommended.

■■3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.

■■If you are using natural gas, do not use copper tubing.

■■Lengths over 20 ft. (6.1 m) should use larger tubing and a different size adapter fitting.

■■If your dryer has been converted to use propane gas, 3/8" propane compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe.

NOTE: Pipe-joint compounds that resist the action of propane gas must be used. Do not use TEFLON®† tape.

■■Must include shut-off valve.

In the U.S.A.:

An individual manual shut-off valve must be installed within 6 ft. (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.

In Canada:

An individual manual shut-off valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shut-off valve be installed within 6 ft. (1.8 m) of the dryer. The location should be easy to reach for opening and closing.

E

C

A

D

B

A.3/8" flexible gas connector

B.3/8" pipe to flare adapter fitting

C.1/8" NPT minimum plugged tapping

D.1/2" NPT gas supply line

E.Gas shut-off valve

®TEFLON is a registered trademark of Chemours.

GAS SUPPLY CONNECTION REQUIREMENTS

■■Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed, to avoid kinking.

■■Use only pipe-joint compound. Do not use TEFLON® tape.

■■This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.

BURNER INPUT REQUIREMENTS

Elevations above 2,000 ft. (610 m):

■■When installed above 2,000 ft. (610 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft. (305 m) increase in elevation.

Gas supply pressure testing

■■The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than 1/2 psi.

DRYER GAS PIPE

■■The gas pipe that comes out through the rear of your dryer has a 3/8" male pipe thread.

11/2"

(38 mm)

3/8" NPT dryer gas pipe

*53/4"

(146 mm)

*NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (254 mm) or

15.5" (394 mm) from the floor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the floor.

8

INSTALL LEVELING LEGS

1. Prepare dryer for leveling legs

To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently

lay dryer down on cardboard.

2. Screw in leveling legs

Diamond diamond marking marking

Examine leveling legs; find diamond marking. Screw legs into leg holes by hand, then use a wrench to finish turning legs until diamond marking is no longer visible.

Place a carton corner post from dryer packaging under each of the two dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

MAKE GAS CONNECTION

(gas models only)

1. Connect gas supply to dryer

A

B

 

A.Flared male fitting

B.Non-flared male fitting

Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to dryer. Use pipe-joint compound

on threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.

NOTE: For propane gas connections, you must use pipejoint compound resistant to action of propane gas. Do not use TEFLON® tape.

2. Plan pipe fitting connection (option 1)

D

C

A

B

 

A. 3/8" flexible gas connector

C. 3/8" to 3/8" pipe elbow

B. 3/8" dryer gas pipe

D. 3/8" pipe-to-flare adapter

 

 

fitting

A combination of pipe fittings must be used to connect dryer to existing gas line. A recommended connection is shown. Your connection may be different, according to supply line type, size, and location.

3. Open shut-off valve

A

B

A.Closed valve

B.Open valve

Open shut-off valve in supply line; valve is open when handle is parallel to gas pipe. Then, test all connections by brushing on an approved noncorrosive leak-detection solution.

Bubbles will show a leak. Correct any leak found.

9

VENTING

Venting Requirements

Exhaust hoods:

■■ An exhaust hood should cap the vent to keep rodents and insects from entering the home.

■■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

■■ Do not use an exhaust hood with a magnetic latch.

Recommended Styles:

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

■■ Following these venting requirements will minimize ducting air noise.

■■ Exhaust air must not be discharged into a flue for exhausting fumes from appliances burning gas or other fuels, including open fires (i.e., available airflow into the room should match airflow out from the room).

■■ Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

4" (102 mm)

4" (102 mm) heavy metal exhaust vent

■■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.

■■ Do not use plastic or metal foil vent.

Rigid metal vent:

■■ Recommended for best drying performance and to avoid crushing and kinking.

Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location.

■■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

■■ Do not install in enclosed walls, ceilings, or floors. ■■ The total length should not exceed 73/4 ft. (2.4 m).

■■ The length of flexible metal vent used must be included in the overall vent system design as shown in the “Vent System Charts.”

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal

or flexible metal vents. Review “Vent System Charts” and, if necessary, modify existing vent system to achieve best drying performance.

 

 

 

Louvered Hood

 

Box Hood

Acceptable Style:

Angled Hood

Elbows:

■■ 45° elbows provide better airflow than 90° elbows.

Good Better

Clamps:

■■ Use clamps to seal all joints.

■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

10

Plan Vent System

 

 

Choose your exhaust installation type

 

Recommended exhaust installation:

 

 

B

C

A

 

D

 

F

E

 

 

 

G

 

 

B

 

 

H

 

A. Dryer

F. Rigid metal or

 

B Elbow

flexible metal vent

 

C. Wall

G. Vent length

 

D. Exhaust hood

necessary to

 

E. Clamps

connect elbows

 

H. Exhaust outlet

 

 

 

Optional exhaust installations:

This dryer can be converted to exhaust out the right side, left side (models with standard vent system only), or through the bottom. If you prefer, you may contact your local dealer to have the dryer converted.

A B C

A.Standard rear offset exhaust installation

B.Leftor right-side exhaust installation

C.Bottom exhaust installation

Special provisions for mobile homes:

Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside.

Determine vent path:

■■Select route that will provide straightest and most direct path outdoors.

■■Plan installation to use fewest number of elbows and turns.

■■When using elbows or making turns, allow as much room as possible.

■■Bend vent gradually to avoid kinking. ■■Use as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

■■Use the “Vent System Charts” on the next page to determine type of vent material and hood combinations acceptable

to use.

NOTE: Do not use vent runs longer than those specified in “Vent System Charts.”

Exhaust systems longer than those specified will: ■■ Shorten life of dryer.

■■ Reduce performance, resulting in longer drying times and increased energy usage.

11

The “Vent System Charts” provide venting requirements that will help achieve best drying performance.

Standard Vent System Chart

Number of

Type

Angled

90° elbows

of vent

hoods

 

 

 

0

Rigid metal

64 ft. (20 m)

 

 

 

1

Rigid metal

54 ft. (16.5 m)

 

 

 

2

Rigid metal

44 ft. (13.4 m)

 

 

 

3

Rigid metal

35 ft. (10.7 m)

 

 

 

4

Rigid metal

27 ft. (8.2 m)

 

 

 

Long Vent System Chart*

Number of

Type

Angled

90° elbows

of vent

hoods

 

 

 

0

Rigid metal

160 ft. (48.8 m)

 

 

 

1

Rigid metal

150 ft. (45.7 m)

 

 

 

2

Rigid metal

140 ft. (42.7 m)

 

 

 

3

Rigid metal

130 ft. (39.6 m)

 

 

 

4

Rigid metal

120 ft. (36.6 m)

 

 

 

*For some models; for all other models, refer to the “Standard Vent System Chart” above. To find your model number, refer to the model and serial number plate in the inner door well.

NOTE: For long vent systems, use of box/louvered hoods will improve venting, regardless of length.

Install Vent System

1. Install exhaust hood

12" min.

(305 mm)

12" min.

(305 mm)

Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.

2. Connect vent to exhaust hood

Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent because they can catch lint.

CONNECT INLET HOSE

(STEAM MODEL ONLY)

For non-steam models, skip to “Connect Vent.”

The dryer must be connected to the cold water faucet using the new inlet hoses (not supplied). Do not use old hoses.

NOTE: Replace inlet hoses after five years of use to reduce the risk of hose failure. Record hose installation or replacement dates on the hoses for future reference.

Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found.

1. Turn cold water off, remove hose, and replace rubber washer

Turn cold water faucet off and remove washer inlet hose.

Remove old rubber washer from inlet hose and replace with new rubber washer.

12

2. Attach short hose and “Y” connector

5. Attach long hose to dryer fill valve

 

and tighten coupling

Attach short inlet hose to cold water faucet. Screw on coupling by hand until it is seated on faucet. Then attach “Y” connector to male end of the short inlet hose. Screw on coupling by hand until it is seated on connector.

3. Tighten couplings

Using pliers, tighten the couplings with additional 2/3 turn. NOTE: Do not overtighten. Damage to the coupling can result.

4. Attach long hose to “Y” connector and tighten couplings

Attach one of the 5 ft. (1.5 m) inlet hose ends to the “Y” connector. Attach washer cold inlet hose to other side of “Y” connector. Screw on coupling by hand until it is seated

on connector. Using pliers, tighten the couplings an additional 2/3 turn.

NOTE: Do not overtighten. Damage to the coupling can result.

Remove protective cap from water inlet valve. Attach other end

of long hose to fill valve at bottom of dryer

back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional 2/3 turn.

NOTE: Do not overtighten. Damage to the coupling can result.

6. Turn on cold water faucet

Check that the water faucets are turned on.

7. Check for leaks

Check for leaks around “Y” connector, faucet, and hoses.

13

CONNECT VENT

1. Connect vent to exhaust outlet

Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.

LEVEL DRYER

1. Level dryer

Place level here

Check levelness of dryer from

side to side. Repeat from front to back.

NOTE: The dryer must be level for the moisture sensing system to operate correctly.

2. Move dryer to final location

Not Level

LEVEL

Not Level

2. Adjust leveling legs

Move dryer to final location, taking care not to crush or kink vent or flexible gas line.

After dryer is in place, remove corner posts and cardboard from under dryer.

If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once dryer is level, make sure all four legs are snug against the floor and the dryer does not rock.