30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS |
|
|
|
|
|
PRODUCT DIMENSIONS |
|
|
|||||||||||||||
MGR7661W |
MGR7662W |
MGR7685A |
|
|
|
|
|
|
|
|
|
|
|||||||||||
Electrical Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time- |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
delay fuse or circuit breaker is also recommended. It is recommended that a |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
separate circuit serving only this range be provided. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Gas Supply Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Type of gas |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Natural gas: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
This range is design-certified by CSA International for use with Natural gas or, |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
A |
|
|
|
|
|
|
|
||||||||||||||
after proper conversion, for use with LP gas. |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
● This range is factory set for use with Natural gas. See “Gas Conversions” |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
section. The model/serial rating plate located on the oven frame behind the |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
top left side of the oven door has information on the types of gas that can be |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
used. If the types of gas listed do not include the type of gas available, check |
|
F |
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
C |
|
|||||||||||||||
|
|
|
|
|
B |
|
|
||||||||||||||||
with the local gas supplier. |
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
LP gas conversion: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Conversion must be done by a qualified service technician. No attempt shall be |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
made to convert the appliance from the gas specified on the model/serial |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
rating plate for use with a different gas without consulting the serving gas |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
supplier. See “Gas Conversions” section. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Gas Supply Line |
|
|
|
|
|
|
|
|
|
|
|
|
E |
|
|
||||||||
● Provide a gas supply line of ³⁄ " (1.9 cm) rigid pipe to the range location. A |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
smaller size pipe on longer runs may result in insufficient gas supply. With |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
D |
|
|
|
|
|
||||||||||||||
LP gas, piping or tubing size can be ¹⁄ " (1.3 cm) minimum. Usually, LP gas |
|
|
|
|
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
||||||||||||||
suppliers determine the size and materials used in the system. |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Do not use TEFLON®† tape. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Flexible metal appliance connector: |
|
|
|
|
|
|
|
A. 27⁄" (70.8 cm) max. depth with handle |
|
|
|||||||||||||
|
|
|
|
|
|
|
B. 36" (91.4 cm) cooktop height (max.) with leveling legs |
||||||||||||||||
● If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to |
|
|
|
||||||||||||||||||||
|
|
|
screwed all the way in* |
|
|
||||||||||||||||||
152.4 cm) long, ¹⁄ " (1.3 cm) or ³⁄ " (1.9 cm) I.D., flexible metal appliance |
|
|
|
|
|
||||||||||||||||||
|
|
|
C. 46⁄" (119.1 cm) overall height (max.) with leveling |
|
|
||||||||||||||||||
connector may be used for connecting range to the gas supply line. |
|
|
|
|
|
||||||||||||||||||
|
|
|
legs screwed all the way in* |
|
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D. 29⁄" (75.9 cm) width |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
E. 25⁄" (64.6 cm) depth. Back of range to front of |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
cooktop** |
|
|
||||
● A ¹⁄ " (1.3 cm) male pipe thread is needed for connection to the female pipe |
|
|
|
|
|
||||||||||||||||||
|
|
|
F. Model/serial rating plate (located on the oven frame |
|
|
||||||||||||||||||
threads of the inlet to the appliance pressure regulator. |
|
|
|
|
|
||||||||||||||||||
|
|
|
behind the top left side of the oven door) |
|
|
||||||||||||||||||
● Do not kink or damage the flexible metal tubing when moving the range. |
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Rigid pipe connection: |
|
|
|
|
|
|
|
|
|
|
IMPORTANT: Range must be level after installation. Follow the instructions in the |
||||||||||||
The rigid pipe connection requires a combination of pipe fittings to obtain an |
|
||||||||||||||||||||||
|
“Level Range” section. Using the cooktop as a reference for leveling the range is not |
||||||||||||||||||||||
in-line connection to the range. The rigid pipe must be level with the range |
|
recommended. |
|
|
|||||||||||||||||||
connection. All strains must be removed from the supply and fuel lines so |
|
**Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs. |
|||||||||||||||||||||
range will be level and in line. |
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
**Front of door and drawer may extend further forward, depending on styling. |
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
●Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the range opening, such as an adjacent cabinet. It should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the range.
|
B |
|
|
A. Gas supply line |
A |
|
|
B. Shutoff valve “open” position |
|
|
|
C. To range |
|
|
|
|
C |
|
|
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. |
|
Page 1 of 2 |
|
|
|
|
|
Because Whirlpool Corporation policy includes a continuous commitment to improve |
Dimensions are for planning purposes only. For complete details, see Installation |
Ref. W10526974A |
|
our products, we reserve the right to change materials and specifications without notice. |
Instructions packed with product. Specifications subject to change without notice. |
2/13/13 |