Maytag MDB8751AW', MDB7751AW', MDB8951AW', MDBM755AW', ADB3500AW User Manual

0 (0)

Dishwasher — Technical Information

ADB3500AW*, MDBM755AW*, MDB7751AW*, MDB8751AW*, MDB8951AW*

Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.

Refer to Service Manual 16021814 for detailed installation, operating, testing, troubleshooting, and disassembly instructions

!CAUTION

All safety information must be followed as provided in Service Manual 16021814.

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

Benefits

ADB3500AW*

MDBM755AW*

MDB8751AW*

MDB8951AW*

 

 

MDB7751AW*

 

 

 

 

 

 

 

Wash cycles

5

4

6

5

Heavy Wash

X

X

X

X

Normal Wash

X

X

X

X

Quick Wash

X

 

 

 

Light Wash

 

X

X

X

Insta Wash

 

 

X

X

Auto Clean

 

 

X

X

Rinse Only

X

X

X

X

Features

 

 

 

 

Sound package

Sofsound III™

QuietSeries™

QuietSeries™

QuietSeries™

 

200

300

400

 

 

High Temp

X

X

X

X

Wash

 

 

 

 

Electronic

X

X

X

X

Controls

 

 

 

 

Sanitizer

 

X

X

X

Sensor clean

X

X

X

X

Water Filtration

100% Filtered wash

Micro-Fine Plus

Micro-Fine Plus

Micro-Fine Plus

water

Filtration

Filtration

Filtration

 

Delay Start

2,4 or 6 Hour Delay

2,4 or 6 Hour

1-9 Hour Delay

1-9 Hour Delay

Start

Delay Start

Start

Start

 

Energy Star

X

X

X

X

Hard Food

X

X

X

X

Disposer

 

 

 

 

Child lockout

X

X

X

X

Touch Pad

10

7

12

13

Controls

 

 

 

 

Silverware

In door

Wash

Wash

Wash

Location

Compartment

Compartment

Compartment

 

Low rinse aid

X

 

 

 

indicator

 

 

 

 

 

 

 

July 2005

1

16026394

©2005 Maytag Services

 

 

Maytag MDB8751AW', MDB7751AW', MDB8951AW', MDBM755AW', ADB3500AW User Manual

Component Specifications

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

Specifications

Value

 

 

Power Source

 

 

 

Voltage AC

120 VAC

 

Amperage (Single Unit)

15 A

 

 

Frequency

60 Hz

 

 

Motor horsepower

1/3

 

 

 

 

 

Dimensions

 

 

Height−overall

33 ½” to 35 ¼”

 

Weight

71

 

 

Illustration

Component

Test Procedure

Results

Dishwasher Motor

Measure resistance from

 

CCW rotation only

ST5 (Motor Common – blue) to ST8

 

(Motor Main - yellow) .........................

3 to 4 Ω

viewed from shaft

See Component Specifications/Motor

 

end.

 

Connections for details.

 

1/3HP

 

 

120V/60hz, 3.2 amps,

 

 

3250 RPM

 

 

Main Wattage, 285

 

 

watts

 

 

Start Wattage, 1115

 

 

watts

 

 

Control Panel

See Component Specifications/

 

 

 

Membrane Readings for

 

 

 

troubleshooting/pin-out instructions.

 

Water valve

Measure resistance from

 

120V/60hz, 7 watts

J6 Pin 4 Aqua (Float switch) to ST4

 

Black (Common) ...............................

1.1 k Ω

1.13 ± .10 gpm at 20-

 

(This value assumes the float switch is

120 psi

 

closed).

Vent wax motor

Measure resistance from J6 Pin 1

120V with 1/4"

Purple (Vent) to ST4 Black (Common) 1.2 k Ω

...........................................................

actuation stroke

 

within 90 seconds

 

16026394

2

July 2005

 

 

©2005 Maytag Services

Component Specifications

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

Illustration

Component

Test Procedure

Results

 

Dispenser wax motor

Measure resistance from J6 Pin 3

 

 

 

Tan (Dispenser) to ST4 Black

 

 

120V with 1/4"

(Common) .........................................

2 k Ω

 

actuation stroke

 

 

 

within 90 seconds

 

 

Limit Thermostat

Close on Temperature drop @ 149°F

 

 

 

± 7°F (Temp) .......................................

0 Ω

= Closed

 

Open on Temperature drop @ 164°F

 

 

 

± 4°F (Temp) .......................................

Infinite Ω = Open

Sensor/Thermistor

10KΩ ± 3% at 77°F and 2.4 k Ω ±

 

 

 

6.5% at 140°F

 

 

 

J5 pin 1 - Orange (Temp) to J5 Pin 4 -

Infinite Ω = Open

 

Red (Neutral) .......................................

 

 

0 Ω

= Closed

 

 

 

 

Heater/Heating

Measure resistance from ST1

 

 

Element

Red/Black (Heater) to ST11 White

 

 

120v/60hz, 650 watts

(Common) ...........................................

16 Ω

 

 

(This value assumes the high limit

± 5% in air, 830 watts

 

thermostat is closed).

± 5% in 90°F water

 

 

 

 

 

 

 

Drain Motor

Measure resistance from

 

 

 

ST6 Gray (Drain) to ST4 Black

 

 

120v/60hz

(Common) ...........................................

25 Ω

 

45 watts

 

 

 

July 2005

3

16026394