Maytag MDB9600AWW, mdb8600awb, MDB8600AWW, MDB8600AWS, MDB9600AWQ User Manual

...
0 (0)

Technical InformationDishwasher

MDB8600AWB MDB8600AWQ MDB8600AWS MDB8600AWW MDB9600AWB MDB9600AWQ MDB9600AWS MDB9600AWW

Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service Manual 16021814.

!CAUTION

All safety information must be followed as provided in Service Manual 16021814.

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power.

Specifications

MDB8600AW*

MDB9600AW*

Benefits

MDB8600AW*

MDB9600AW*

Power Source

 

 

Wash cycles

5

6

Voltage AC

120 VAC

120 VAC

Heavy Wash

X

X

Amperage

15 A

15 A

Normal Wash

X

X

(Single Unit)

 

 

 

 

 

Frequency

60 Hz

60 Hz

Light Wash

X

X

Motor

1/3

1/3

Rinse Only

X

X

horsepower

 

 

 

 

 

Receptacle

N/A

N/A

Auto Clean

X

X

Plug

N/A

N/A

Drying System

X

X

Dimensions

 

 

Features

 

 

Height−overall

33 ½” to 35 ¼”

33 ½” to 35 ¼”

QuietSeries 300™

X

X

Width

23 7/8”

23 7/8”

*Sanitizer

X

X

Depth

23 1/2”

23 1/2”

*ToughScrub™

X

X

Weight

 

 

*160° Wash

 

X

Un-crated

65 lbs.

65 lbs.

*Extra Rinse

X

X

 

 

 

1-9 Hour Delay Start

X

X

 

 

 

Control Lock

X

X

 

 

 

Energy Star

X

X

 

 

 

Active Vent Dry

X

X

 

 

 

Finer Filtration

X

X

 

 

 

Hard Food

X

X

 

 

 

Disposer

 

 

 

 

 

Remaining Time

X

X

 

 

 

Countdown Display

 

 

 

 

 

Integrated Control

 

X

 

 

 

Panel

 

 

 

 

 

Angled Panel with

X

 

 

 

 

Microprocessor

 

 

 

 

 

Controls

 

 

 

 

 

11 Touch Pad

X

 

 

 

 

Controls

 

 

 

 

 

13 Touch Pad

 

X

 

 

 

Controls

 

 

*On selected models only

 

 

 

 

May 2004

1

16023220

©2004 Maytag Services

 

 

Maytag MDB9600AWW, mdb8600awb, MDB8600AWW, MDB8600AWS, MDB9600AWQ User Manual

Component Specifications

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power.

Illustration

Component

Test Procedure

Results

 

Dishwasher Motor

Measure resistance from

 

 

 

ST5 (Motor Common – blue) to ST8

 

 

CCW rotation only

(Motor Main - yellow) ...........................

3 to 4 Ω

 

viewed from shaft

See Component Specifications/Motor

 

 

end.

Connections for details.

 

1/3HP

120V/60hz, 3.2 amps, 3250 RPM

Main Wattage, 285 watts

Start Wattage, 1115 watts

Control Board See Component Specifications/ Membrane Readings for troubleshooting/pin-out instructions.

Water valve

Measure resistance from

 

 

J6 Pin 4 Aqua (Float switch) to ST4

 

120V/60hz, 7 watts

Black (Common) .................................

1.1 k Ω

1.13 ± .10 gpm at 20-

 

(This value assumes the float switch is

120 psi

 

closed).

Vent wax motor

Measure resistance from J6 Pin 1

120V with 1/4"

Purple (Vent) to ST4 Black (Common) 1.2 k Ω

 

actuation stroke

 

within 60 seconds

 

Dispenser wax motor

Measure resistance from J6 Pin 3

2 k Ω

 

Tan (Dispenser) to ST4 Black

 

120V with 1/4"

(Common).

 

actuation stroke

 

 

within 60 seconds

 

 

16023220

2

May 2004

 

 

©2004 Maytag Services

Component Specifications

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing, unless testing requires power.

Illustration

Component

Test Procedure

 

Results

 

Limit Thermostat

Close on Temperature drop @ 149°F

 

 

 

 

± 7°F (Temp) ......................................

0 Ω

= Closed

 

 

Open on Temperature drop @ 164°F

 

 

 

 

± 4°F (Temp) ......................................

Infinite Ω = Open

Sensor/Thermistor

10KΩ ± 3% at 77°F and 2.4 k Ω ±

 

 

 

6.5% at 140°F

 

 

 

J5 pin 1 - Orange (Temp) to J5 Pin 4 -

Infinite Ω = Open

 

Red (Neutral) .....................................

 

 

0 Ω

= Closed

 

 

 

 

Heater/Heating

Measure resistance from ST1

 

 

Element

Red/Black (Heater) to ST11 White

 

 

120v/60hz, 650 watts

(Common) ..........................................

16 Ω

 

 

(This value assumes the high limit

± 5% in air, 830 watts

 

thermostat is closed).

± 5% in coldwater

 

 

 

 

 

 

 

Drain Motor

Measure resistance from

 

 

 

ST6 Gray (Drain) to ST4 Black

 

 

120v/60hz

(Common) ..........................................

25 Ω

 

 

See section “Motor Connections and

 

 

 

Diagram” for wiring contacts.

 

 

May 2004

3

16023220

©2004 Maytag Services

 

 

Loading...
+ 5 hidden pages