Amana 9QZ22RC, 10QZ22RC, 12QZ22RC, 9QZ22RC1, 10QZ22RC1 QZ22RC Rotary Switch Conversion Service Kit

...
0 (0)
Amana 9QZ22RC, 10QZ22RC, 12QZ22RC, 9QZ22RC1, 10QZ22RC1 QZ22RC Rotary Switch Conversion Service Kit

 

20194801

 

QZ22RC Rotary Switch

 

 

Installation

 

Conversion

 

 

Instructions

 

Service Kit

 

 

 

 

 

 

 

 

 

 

 

Description

The Rotary Switch Conversion Kit convert QZ model window units from electronic control to rotary switch control. The kit consists of a rotary control switch, thermostat, escutcheon plate, parts label and wiring diagram.

Kit #

Model #

RSCK01A

9QZ22RC

 

10QZ22RC

 

12QZ22RC

 

9QZ22RC1

 

10QZ22RC1

 

12QZ22RC1

Unit Preparation

WARNING

To avoid death or personal injury due to electrical shock, turn fan control off and unplug power cord before performing maintenance. After performing the required maintenance, reconnect power.

Instructions

1.Remove horizontal insert (indoor grill), filter, electronic board selector knobs (2), and front (4 screws).

2.Remove sensing bulb and bulb clips from coil.

3.Remove the control panel (3 screws) and unplug the control board from the terminal housing.

4.Remove the four screws connecting the control board to the control panel. Discard the board.

WARNING

Discharge a capacitor through a 20 to 30 ohm resistor before handling.

6.Disconnect the black BK-10 wire from the capacitor (“C” terminal) on the terminal housing.

7.Cut the remaining five (5) wires on the terminal housing and discard terminal housing.

8.Strip the wires and place and crimp a quick connect terminal on each wire.

9.Attach the new rotary control switch (2 screws) to the control panel with the knob stem through the same hole that the temperature control knob stem was located, and orient switch such that the side with the four terminals will be beside the evaporator coil, and the side with the single terminal will be on your right.

10.Attach the new thermostat body to the control panel (2 screws) with knob stem through the same hole that the fan control knob stem was located, and orient the thermostat body with the wiring terminals on the bottom.

ROTARY CONTROL

SWITCH

THERMOSTAT

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION

ATTENTION SERVICE PERSONNEL

As a professional servicer you have an obligation to know the product better than the customer. This includes all safety precautions and related items.

Prior to actual installation, thoroughly familiarize yourself with these instructions. Pay special attention to all safety warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation.

Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use.

Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good safety practices...follow them.

The precautions listed in these instructions should not supersede existing practices but should be considered as supplemental information.

September 1997