Manitowoc Ice UD0140A, UD0140W, UD0140AE, UY0140A, UY0140W Operator’s Manual

...
4.4 (5)

Manitowoc

UnderCounter

Ice Machines

Installation, Use & Care Manual

This manual is updated as new information and models are released.

Visit our website for the latest manual. www.manitowocice.com

America’s #1 Selling Ice Machine

Part Number 040002909 Rev02 4/15

Table of Contents

Section 1

 

General Information

 

Model Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Bin Caster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Arctic Pure Water Filter System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Manitowoc Cleaner and Sanitizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Section 2

 

Installation Instructions

 

Location of Ice Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Ice Machine Heat of Rejection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Leveling the Ice Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

Electrical Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Fuse/Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Total Circuit Ampacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Ground Fault Circuit Interrupter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Water Service/Drains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Water Inlet Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Drain Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Cooling Tower Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Water Supply and Drain Line Sizing/Connections . . . . . . . . . . . . . . . . . . . . . . . .

11

Water Level Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Water/Drain Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Before Starting the Ice Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Section 3

 

Operation

 

Touch Pad Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Clean . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Bin Full . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Ice Making Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Safety Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Part Number 040002909 Rev02 4/15

1

Table of Contents (continued)

Section 4

Maintenance

Interior Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Cleaning and Sanitizing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Remove Parts for Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Preventative Maintenance Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Ice Machine Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Cleaning the Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Removal from Service/Winterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Section 5

Customer Support

Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Safety Limit Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Commercial Ice Machine Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Residential Ice Machine Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

2

Part Number 040002909 Rev02 4/15

Section 1

General Information

Model Numbers

This manual covers the following models:

Self-Contained

Self-Contained

Air-Cooled

Water-Cooled

UD0140A

UD0140W

UD0140AE

--

UY0140A

UY0140W

UY0140AE

--

UR0140A

--

UR0140AE

--

UD0190A

--

UD0190AE

--

UY0190A

--

UY0190AE

--

UR0190A

--

UR0190AE

--

UD0240A

UD0240W

UD0240AE

UD0240WE

UY0240A

UY0240W

UY0240AE

UY0240WE

UR0240A

--

UR0240AE

--

UD0310A

UD0310W

UD0310AE

--

UY0310A

UY0310W

UY0310AE

--

UR0310A

UR0310W

UR0310AE

--

SHIPPING WEIGHT

Model Family

Shipping Weight

U0140

153 lbs (69 kg)

U0190

153 lbs (69 kg)

U0240

160 lbs (73 kg)

U0310

211 lbs (96 kgs)

Read These Before Proceeding:

 

 

 

 

 

! Warning

 

 

 

 

 

 

 

Do not operate equipment that has been misused,

 

 

abused, neglected, damaged, or altered/modified

 

 

from

that

of

or iginal

manufactured

specifications.

 

 

This

appliance

is n ot

intended for

use

by per sons

 

 

(including children) with reduced physical, sensory

 

 

or mental capabilities, or lack of experience and

 

knowledge,

 

unless

they

have

 

been

give

 

supervision

concerning

use

of the

appliance

by a

 

 

person responsible for their safety. Do not allow

 

children to play with this appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

! Caution

 

 

 

 

 

 

 

Proper

installation,

care

and

maintenance

 

are

 

essential

for

maximum performance

and trouble

-

 

free operation of your equipment. Visit our website

 

 

 

www.manitowocfsg.com

 

for

manual

updates,

 

translations,

 

or cont

act

information

for

service

 

agents in your area.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Important

Routine adjustments and maintenance procedures outlined in this ma nual are not covered by the warranty.

 

 

! Warning

 

 

 

 

Read this manual thoroughly before operating,

 

installing

or

performing

maintenance

on

the

equipment.

Failure to follow instructions in

this

 

manual can cause property damage, injury or death.

 

 

 

 

 

 

 

 

Part Number 040002909 Rev02 4/15

3

Manitowoc Ice UD0140A, UD0140W, UD0140AE, UY0140A, UY0140W Operator’s Manual
Part Number 040002909 Rev02 4/15
4
Do not store gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
This product is hermetically sealed and contains fluorinated greenhouse gas R404A.
! Warning
! Warning
! Warning
Do not obstruct machine vents or openings.
Clean up any water or ice o n counter or floor to prevent personal injuries. Always inspect the equipment for leakage after cleaning, maintenance
or service procedures are performed.
All covers and access panels must be in place and properly secured, before operating this equipment.
! Warning
! Warning
Do not damage the refrigeration circuit when Do not damage the refrigeration circuit when installing, maintaining or servicing the unit. installing, maintaining or servicing the unit.
! Warning
! Warning
! Warning
This equipment contains high voltage electricity and refrigerant charge. Installation and repairs are to be performed by properly trained technicians aware of the dangers of dealing with high voltage electricity and refrigerant under pressure. The technician must
also be ce rtified in proper refrigerant handling and
servicing procedures. All lo ckout and tag outRead this man ual thoroughly before operating, procedures must be followed when working on this installing or performing maintenance on the equipment. equipment.
! Warning
Only trained and qualified personnel aware of the dangers of refrigerant under pressure, electrical shock, and incorrect lifting/moving hazards, should install, maintain or service this equipment.
! Warning
It is the responsibility of the equipment owner to ! Warning perform a Personal Protective Equipment Hazard
Personal injury is possible when moving this Assessment to ensure adequate protection during equipment. Two or more people aware of the maintenance procedures.
possible lifting and moving hazards are required when moving or relocating this equipment.
! Warning
Do not use electrical appliances or accessories other than those supplied by Manitowoc for your ice machine model.
! Warning
Do not clean with water jet.
General Information
! Warning
Section 1

Section 1

General Information

 

 

Accessories

Contact your Manitowoc distributor for these optional accessories:

BIN CASTER

Replaces standard legs.

ARCTIC PURE WATER FILTER SYSTEM

Engineered specifically for Manitowoc ice machines, Arctic Pure water filters are an efficient, dependable, and affordable method of inhibiting scale formation, filtering sediment, and removing chlorine taste and odor.

MANITOWOC CLEANER AND SANITIZER

Manitowoc Ice Machine Cleaner and Sanitizer are available in convenient 16 oz. (473 ml) and 1 gal (3.78 l) bottles. These are the only cleaner and sanitizer approved for use with Manitowoc products.

Cleaner Part Number

Sanitizer Part Number

16oz

94-0456-3

16oz

94-0565-3

1 Gallon

94-0580-3

1 Gallon

94-0581-3

LUMINICE™

The LuminIce™ growth inhibitor recirculates the air in the ice machine foodzone over a UV bulb. This process will inhibit the growth of common micro-organisms on all exposed foodzone surfaces.

LuminIce™ bulbs require replacement on a yearly basis.

Cleanup Procedure for Accidental Bulb Breakage

The cleanup procedure is identical to the procedure used to clean up compact fluorescent (CFL) or fluorescent tube lights. These lights contain a small amount of mercury sealed within a glass tube. Breaking these types of lights will release mercury and mercury vapor. The broken bulb can continue to release mercury vapor until it is cleaned up and removed.

The latest EPA procedures can be viewed on their website at www.epa.gov/cfl/cflcleanup.html.

Part Number 040002909 Rev02 4/15

5

General Information

Section 1

 

 

THIS PAGE INTENTIONALLY LEFT BLANK

6

Part Number 040002909 Rev02 4/15

Section 2

Installation Instructions

Location of Ice Machine

The location selected for the ice machine must meet the following criteria. If any of these criteria are not met, select another location.

The location must be indoors.

The location must be free of airborne and other contaminants.

The air temperature must be at least 40 F (4 C), but must not exceed 110 F (43 C).

The location must not be near heat-generating equipment or in direct sunlight.

The location must be capable of supporting the weight of the ice machine and a full bin of ice.

The location must allow enough clearance for water, drain and electrical connections in the rear of the ice machine.

The location must not obstruct airflow through or around the ice machine (condenser airflow is in and out the front). Refer to the chart below for clearance requirements.

The location must not be near garbage or other contaminants.

The ice machine must use legs or be sealed to the floor. Before sealing to the floor the rubber bumpers on the bottom of the ice machine must be removed.

 

Self-Contained

Self-Contained

 

Air-Cooled

Water-Cooled

Top/Sides

5" (127 mm)*

5" (127 mm)*

Back

5" (127 mm)*

5" (127 mm)*

NOTE: The ice machine may be built into a cabinet. There is no minimum clearance requirement for the top or left and right sides of the ice machine. The listed values are recommended for efficient operation and servicing only.

 

 

! Caution

 

 

 

The ice

mac hine

must beprotected

if it

will be

 

subjected

to temperatures below F32 (0C).

 

Failure

caused

by exposur

e

to fre

temperatures is not covered by the warranty. See

“Removal from Service/Winterization” Section 4.

 

 

 

 

 

 

Ice Machine Heat of Rejection

Series

Heat of Rejection*

Ice Machine

Air Conditioning**

Peak

U140

2400

2900

U190

2200

2600

U240

2400

3400

U310

3800

6000

*B.T.U./Hour

**Because the heat of rejection vari es during the ice making cycle, the figure shown is an average.

Ice machines, like other refrigeration equipment, reject heat through the condenser. It is helpful to know the amount of heat rejected by the ice machine when sizing air conditioning equipment where self-contained aircooled ice machines are installed.

! Warning

Two or more people or a lifting device are required to lift this appliance.

Leveling the Ice Machine

1.Screw the leveling legs onto the bottom of the ice machine.

2.Screw the foot of each leg in as far as possible.

! Caution

The legs must be screwed in tightly to prevent them from bending.

3. Move the ice machine into its final position.

! Warning

Do not obstruct ice machine vents or openings.

4.Level the ice machine by using a level on top of the ice machine. Turn each foot as necessary to level the ice machine from front to back and side to side.

ezing

Part Number 040002909 Rev02 4/15

7

Installation Instructions

Section 2

 

 

Electrical Service

GENERAL

! Warning

All wiring must conform to local, state and national codes.

! Caution

Operate equipment only onthe type of electricity indicated on the specification plate.

VOLTAGE

The maximum allowable voltage variation is 10% of the rated voltage on the ice machine model/serial number plate at start-up (when the electrical load is highest).

The 115/1/60 ice machines are factory pre-wired with a 8’ power cord, and NEMA 5-15P-plug configuration.

The 208-230/1/60 and 230/50/1 ice machines are factory pre-wired with a 8’ power cord only, no plug is supplied.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for each ice machine.

! Warning

The ice machine must be grounded in accordance with national and local electrical codes.

TOTAL CIRCUIT AMPACITY

The total circuit ampacity is used to help select the wire size of the electrical supply.

The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.

GROUND FAULT CIRCUIT INTERRUPTER

Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the electric circuit (opens it) when it senses an unexpected loss of power, presumably to ground. Manitowoc does not recommend the use of a GFCI/GFI circuit protection with our equipment. If code requires the use of a GFCI/GFI then you must follow the local code. The circuit must be dedicated, sized properly and there must be a panel GFCI/GFI breaker. We do not recommend GFCI/GFI outlets as they are known for more intermittent nuisance trips than panel breakers.

! Warning

If the supply cord is damaged, do not operate the equipment until the cord isreplaced by a service agent or similarly qualified person.

8

Part Number 040002909 Rev02 4/15

Section 2

 

 

 

Installation Instructions

 

 

 

 

 

 

 

ELECTRICAL SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

Ice Machine

Voltage

Air-Cooled

Water Cooled

 

 

Phase

Maximum Fuse/

Total Amps

Maximum Fuse/

Total Amps

 

 

Cycle

Circuit Breaker

 

Circuit Breaker

 

 

U140

115/1/60

15

5.0

15

5.0

 

 

208-230/1/60

15

2.5

--

--

 

 

230/1/50

15

2.5

--

--

 

U190

115/1/60

15

6.0

--

--

 

 

208-230/1/60

15

2.5

--

--

 

 

230/1/50

15

2.5

--

--

 

U240

115/1/60

15

7.0

15

6.0

 

 

208-230/1/60

15

4.0

15

3.0

 

 

230/1/50

15

4.0

15

3.0

 

U310

115/1/60

15

10.0

15

10.0

 

 

208-230/1/60

15

4.5

15

4.0

 

 

 

 

 

 

 

 

 

230/1/50

15

4.5

--

--

 

Part Number 040002909 Rev02 4/15

9

Installation Instructions

Section 2

 

 

Water Service/Drains

WATER SUPPLY

Local water conditions may require treatment of the water to inhibit scale formation, filter sediment, remove chlorine, and improve taste and clarity.

! Caution

Plumbing must conform to state and local codes.

DRAIN CONNECTIONS

Follow these guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin:

Drain lines must have a 1.5 inch drop per 5 feet of run (2.5 cm per meter), and must not create traps.

The floor drain must be large enough to accommodate drainage from all drains.

 

Important

 

 

 

If you

are inst alling

a nitowocMa water

filter

 

system,

refer to the

Inst

allation

Instructions

supplied with the filter system for ice making water

inlet connections.

 

 

 

 

 

 

 

 

 

 

! Warning

For ice making, connect to a potable water supply only.

WATER INLET LINES

Follow these guidelines to install water inlet lines:

Do not connect the ice machine to a hot water supply. Be sure all hot water restrictors installed for other equipment are working. (Check valves on sink faucets, dishwashers, etc.)

If water pressure exceeds the maximum

(80 psig-551.5 kPA) recommended pressure, obtain a water pressure regulator from your Manitowoc distributor.

Install a water shut-off valve and union for both the ice making and condenser water lines.

Insulate water inlet lines to prevent condensation.

Run separate bin and water-cooled condenser drain lines. Insulate them to prevent condensation.

Vent the ice machine drain. Do not vent the condenser drain on water-cooled models.

COOLING TOWER APPLICATIONS

(Water-Cooled Models)

A water cooling tower installation does not require modification of the ice machine. The water regulator valve for the condenser continues to control the refrigeration discharge pressure.

It is necessary to know the amount of heat rejection and the pressure drop through the condenser and water valves (inlet and outlet) when using a cooling tower on an ice machine.

Water entering the condenser must not exceed 90 F (32 C).

Water flow through the condenser must not exceed 5 gallons (19 liters) per minute.

Allow for a pressure drop of 7 psi (48 kPA) between the condenser water inlet and the outlet of the ice machine.

Water exiting the condenser must not exceed 110 F (43 C).

 

Important

 

The

Commonwealth

of Massachusetts requires

 

that

all water-cooled

models must be connected

 

only to a closed loop, cooling tower system.

 

 

 

 

 

10

Part Number 040002909 Rev02 4/15

Section 2

 

 

 

 

Installation Instructions

 

 

 

 

 

 

Water Supply and Drain Line Sizing/Connections

 

 

 

 

 

 

 

 

 

 

Location

Water

Water

 

 

Ice Machine

Tubing Size Up to Ice

 

Temperature

Pressure

 

 

Fitting

Machine Fitting

Ice Making

40 F (4 C) Min.

20 psi (137.9 kPA) Min.

 

3/8" Female Pipe

3/8" (9.5 mm) minimum

Water Inlet

90 F (32 C) Max.

80 psi (551.5 kPA) Max.

 

Thread

inside diameter

CondenserWater

 

 

 

 

3/8" Female Pipe

3/8" (9.5 mm) minimum

Inlet

40 F (4 C) Min.

20 psi (137.9 kPA) Min.

 

Thread

inside diameter

 

 

U310 Only

U310 Only

 

90 F (32 C) Max.

150 psi (1034.2 kPA) Max.

 

1/2" Female Pipe

1/2" (12.7 mm)

 

 

 

 

 

 

 

 

 

 

Thread

minimum inside diameter

CondenserWater

---

---

 

 

1/2" Female Pipe

1/2" (12.7 mm) minimum

Drain

 

 

 

 

Thread

inside diameter

 

---

---

 

 

1/2" Female Pipe

1/2" (12.7 mm) minimum

Bin Drain

 

 

 

 

Thread

inside diameter

ICE THICKNESS ADJUSTMENT

 

 

 

 

 

The ice thickness can be adjusted to three levels.

 

 

 

 

1. Pull forward on the bottom of the bracket until clear

WATER/DRAIN CONNECTIONS

of the tab.

 

 

 

A. Potable Water Inlet

 

2. Slide the bracket over the desired tab and release.

 

 

 

B. Drain

 

• The center position is the normal factory setting.

 

 

 

C. Condenser Water Inlet - (Water-cooled Only)

• To increase bridge thickness, raise the water level.

 

 

D. Condenser Water Outlet - (Water-cooled Only)

 

 

 

 

To decrease bridge thickness, lower the water level.

C D

A

B

 

Thicker

Factory

Thinner

 

Default

 

Bridge

 

Setting

Bridge

 

 

 

 

 

 

 

Model

 

 

 

Total ice weight from one cycle

 

Minimum - Maximum

Minimum - Maximum

 

 

U140

 

 

1.13 - 1.36 lbs

513

- 617 grams

U190

 

 

2.26 - 2.93 lbs

1025

- 1329 grams

U240

 

 

2.26 - 2.93 lbs

1025

- 1329 grams

U310

 

 

2.26 - 2.93 lbs

1025

- 1329 grams

Part Number 040002909 Rev02 4/15

11

Installation Instructions

Section 2

 

 

Before Starting the Ice Machine

All Manitowoc ice machines are factory-operated and adjusted before shipment. Normally, new installations do not require any adjustment.

To ensure proper operation, follow the Operational Checks in Section 3 of this manual. Starting the ice machine and completing the Operational Checks are the responsibilities of the owner/operator.

Adjustments and maintenance procedures outlined in this manual are not covered by the warranty.

! Warning

Do not operate equipment that has been misused, abused, neglected, damaged, or altered/modified from that of original manufactured specifications.

Installation Checklist

Is the ice machine level?

Has all of the internal packing been removed?

Have all of the electrical and water connections been made?

Has the supply voltage been tested and checked against the rating on the nameplate?

Is there proper clearance around the ice machine for air circulation?

Is the ice machine grounded and polarity correct?

Has the ice machine been installed where ambient temperatures will remain in the range of 40° – 110°F (4° – 43°C)?

Has the ice machine been installed where the incoming water temperature will remain in the range of 40° – 90°F (4° – 32°C)?

Is there a separate drain for the water-cooled condenser?

Is the ice machine drain vented?

Are all electrical leads free from contact with refrigeration lines and moving equipment?

Has the owner/operator been instructed regarding maintenance and the use of Manitowoc Cleaner and Sanitizer?

Has the owner/operator completed the warranty registration card?

Has the ice machine and bin been sanitized?

Has the On/Off button been pressed?

Is there a separate drain for the bin?

12

Part Number 040002909 Rev02 4/15

Section 3

Operation

Touch Pad Features

The touch pad offers a series of pressure sensitive buttons to control ice machine operation and provide operational status.

On/Off - Blue = Machine On

Off = Machine Is Off

Delay - Blue = Delay Mode On

Off = Delay Mode Is Off

Clean - Yellow = Clean Cycle On

Flashing = Clean Cycle Paused

Off = Cleaning is Off

Bin Full - Blue = Bin Is Full

Off = Bin Is Not Full

Service - Red = Safety Limit

Off = Doesn’t Need Service

ON/OFF

The On/Off Button is used to start and stop ice making. The blue light indicates whether the ice machine is in Ice Making (light on) or Off (light off).

NOTE: If ice is on the evaporator (during the freeze or harvest cycle) and the On/Off button is pressed; the next cycle will have a thick slab of ice. Press the On/Off button and allow the ice to melt off the evaporator, then start a new freeze cycle.

DELAY

Pressing the Delay button will start a delay period. The ice machine will finish the freeze and harvest cycle and then start the delay period.

Pressing the button once will start a 4 hour delay period.

Pressing the button twice will start a 12 hour delay period.

Pressing the button three times will start a 24 hour delay period.

Pressing the button four times will cancel the delay periods.

NOTE: The delay period will be canceled if power is interrupted to the ice machine. When power is restored, the ice machine will remain Off.

CLEAN

Pressing the Clean button for 3 seconds with the machine off will start a clean cycle. After the clean cycle is complete, the ice machine will automatically start an ice making cycle.

Pressing the Clean button ag ain within 45 seconds of the clean cycle starting will abort the clean cycle.

Pressing the On/Off button anytime during the Clean cycle will de-energize the On/Off LED and the ice machine will stop after the Clean cycle is complete.

Pressing the Clean button will pause the Clean cycle. The On/Off and Clean lights will flash on/off to indicate pause mode. Pressing the Clean button again will continue the Clean cycle from the point of interruption.

NOTE: Opening the ice damper for 30 seconds will cancel the clean cycle.

BIN FULL

The Bin Full light energizes when the bin is full or is deenergized if the bin is not full.

SERVICE

The service light indicates the machine needs attention.

Refer to Section 5 for more information if this light is energized.

Part Number 040002909 Rev02 4/15

13

Operation

Section 3

 

 

Ice Making Sequence of Operation

NOTE: The On/Off button must be depressed and the ice damper must be closed before the ice machine will start.

Water Purge Cycle

The ice machine purges any remaining water from the water trough down the drain.

Freeze Cycle

Prechill - The refrigeration system chills the evaporator before water flow over the evaporator starts. The water inlet valve energizes during the pre-chill and remains on until the ice thickness float switch is satisfied.

Freeze - Water flowing across the evaporator freezes and builds ice on the evaporator. After a sheet of ice has formed, the harvest float switch signals the control board to start a harvest cycle.

Harvest Cycle

Any remaining water is purged down the drain as refrigerant gas warms the evaporator. When the evaporator warms, the sheet of cubes slides off the evaporator and into the storage bin. If all cubes fall clear of the ice damper the ice machine starts another freeze cycle.

Full Bin Cycle

If the ice damper is held open by ice cubes the ice machine shuts off. When the ice damper closes the ice machine starts a new cycle at the water purge.

Control Board Timers

The control board has the following non-adjustable timers:

The ice machine is locked into the freeze cycle for 6 minutes before a harvest cycle can be initiated.

The maximum freeze time is 45 minutes at which time the control board automatically initiates a harvest sequence.

The maximum harvest time is 7 minutes. The control board automatically initiates a freeze sequence when these times are exceeded.

SAFETY LIMITS

Safety limits are stored and indicated by the control board. The number of cycles required to stop the ice machine varies for each safety limit.

Safety limits can be reset by pressing the On/Off button and starting a new ice making cycle.

A safety limit is indicated by an energized Service Light on the touch pad. Refer to Section 5 if you receive a safety limit indication.

Safety Limit 1 -If the freeze time reaches 45 minutes, the control board automatically initiates a harvest cycle. After 6 consecutive 45-minute freeze cycles occur, the ice machine stops.

Safety Limit 2 - If the harvest time reaches 3.5 minutes, the control board automatically energizes the water pump and extends the harvest cycle another 3.5 minutes (7 minutes total). After 7 minutes the ice machine automatically starts a new freeze cycle. If 3 consecutive 7 minute harvest cycles occur, the ice machine stops.

Safety Limit 3 - If the freeze time reaches 4 minutes and water is not sensed, the ice machine stops and initiates a 30 minute delay period. The ice machine will automatically restart at the end of the 30 minute delay period. If 100 consec utive failures occur the ice machine stops.

14

Part Number 040002909 Rev02 4/15

Loading...