Specifications
64-5/16" [1634]
63" [1600]
ECHEL60IN
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH VIEWING AREA
ECHEL60
50,000 BTU (NG)
37,500 BTU (LP)
ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING
Actual Framing Actual Framing Actual Framing Actual Framing
70" 72-1/4" 70" 72-1/4" 47-3/4" 48" 17-1/8" 18-1/4"
ECHELON II 60
Direct Vent Gas Fireplace
59-1/2" x 12-1/2"
30-1/2"
[775]
23-3/4"
[603]
47-3/4"
[1213]
24-1/2"
[622]
18-5/8"
[473]
17-1/8"
[435]
70" [1778]
TOP
74" [1880]
63-1/8" [1603]
J
o
8" [203]
CENTERED ON APPLIANCE
1" [25]
8-9/16"
[217]
15-5/8"
[397]
48-1/2"
[1232]
63"
[1600]
4" [102]
2-3/4" [70]
8-9/16"
[217]
2-3/8" [60]
8-7/8"
[225]
5/8" [16]
25"
24"
[610]
61-3/16" [1554]
CFT FRONT PFF FRONT
Additional information can be found online at www.majesticproducts.com
7-1/4"
[184]
GAS ACCESS
13-1/8"
[333]
16-3/4
[425]
ELECTRICAL ACCESS
8-9/16"
[217]
FRONTLEFT RIGHT
23-3/8"
28-5/16"
[719]
10-1/16"
[256]
61-1/4" [1556]
4-15/16"
[126]
The PFF decorative front has an installed depth of 3/4" [19mm], measured from the
front of the non-combustible finishing material to the front of the decorative front.
71" [1803]
13-1/8"
[333]
[594]

Specifications
MEASUREMENT FROM
TOP EDGE OPENING
24
27
30
31
TO CEILING
9
6
3
Measurement from top edge
opening to bottom of appliance
=24-1/2"
MAX.
Note:
All measurements in inches.
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
Header depth
not to exceed
3-1/2" [89]
Adjust framing dimensions
for interior sheathing (such
as Sheetrock).
If appliance is installed o of oor,
maintain required clearances to
combustibles. Construct platform in
accordance with local building codes.
10" [254]
48"
[1219]
18-1/4"
[464]
72-1/4"
[1835]
31" [787]
0" [0]
0" [0]
55-1/2" [1410]
48" [1219]
1" [25]
1" [25]
ECHEL60
APPLIANCE LOCATION
1"
[807]
[25]
1"
"
[25]
[2019]
72-1/4
[1835]**
112-3/8"
[2854]
Refer to Section 10 of install manual for hearth,
mantel and wall projection information.
If a Heat-Zone
refer to
Section 5.E of install manual for information.
2 HEAT-ZONES = Add 4" to ** dimension
1 HEAT-ZONE = Add 2" to ** dimension
72-1/4 [1835]**
18-1/4"
WALL PENETRATION
Do not pack with insulation or
other material.
10"
63"
[1600]
12"
72-1/4 [1835]**
®
or Heat-Duct will be installed,
[464]
62"
[1570]
* Shows center of vent framing
hole for top venting. Center of hole
is 1" [25] above center of horizontal
vent pipe.
See clearances
in install manual
72-1/4
[1835]**
FRAMING DIMENSION
CLEARANCES TO COMBUSTIBLES
MANTEL PROJECTIONS - COMBUSTIBLE
MANTEL PROJECTIONS - NON-COMBUSTIBLE
Note: All measurements in inches.
MAX.
3
2
1
Measurement from top edg e of opening
to bottom of appliance = 2 4-1/2"
TO CEILING
13-16
6
5
4
7
6
MEASUREMENTS FROM TOP ED GE
OF THE APPLIANCE OPENING
31
MIN.
18
11
10
9
8
OVERLAP FIT
Note: All measurements in inches.
MAX.
INSIDE FIT
TO CEILING
14-16
31 MIN.
7
18
6
5
11
10
9
4
MEASUREMENTS FROM TOP E DGE
OF THE APPLIANCE OPENI NG
Measurement from top edge of opening
to bottom of applianc e = 24-1/2"
Majestic — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | majesticproducts.com
MANTEL LEG/WALL PROJECTIONS
COMBUSTIBLE OR NON-COMBUSTIBLE
Note: Clearance from
opening to
perpendicualar wall
Top View
4-1/2"
minimum
3' maximum
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Acceptable on both sides of opening
PRODUCT LISTING CODES
US ANSI Z21.88-2014
CAN CSA 2.33-2014
UL307B
Top View
FIREPLACE OPENING
See appliance dimension diagram
in install manual - Dimension B
Product information provided is not
complete and is subject to change
without notice. Product installation
must adhere strictly to instructions
accompanying product to avoid risk
of fire and potential injury.
7"
minimum
Note: Clearance from
opening to
perpendicualar wall
UNLIMITED
GS/MAJ/ECHEL60_1118