Livan BT0512-03 User Manual

®
Bluetooth Thermometer BT0512
Display screen
On/Off
Elastic
LED light
Sensor
Battery cover
Extra wrist belt
Proper Use:
The Livan Thermometer BT0512 is a battery
powered wireless transmission device of the
sensor head under the arm to monitor the
body temperature, and the temperature value
will show on the display.
The device transfer the measured values to
the corresponding application on user’s smart-
phone by Bluetooth
Against Indications:
The device is not suitable for use in emergen-
cies situations.
Contact your doctor before using the device on
children who under 3 years
Caption:
This instruction manual belongs to
this device. It contains important
information about starting up and
operation. Read the instruction manual thoroughly.
Non-observance of these instructions can result in
serious injury or damage to the device.
WARNING
These warning notes must be observed
to prevent any injury to the user.
CAUTION
These notes must be observed to
prevent any damage to the device.
NOTE
These notes give you useful additional
information on the installation or
operation.
Lot number
Manufacturer
Date of manufacture
Classification: Type BF applied part
IP22 protection against solid foreign
objects of 12.5 mm Ø and greater and against
vertically falling water drops when enclosure
tilted up to 15°.
EN -IMPORTANT INFORMATION!-
RETAIN FOR FUTURE USE!
Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use. Should you give this device to an­other person, it is vital that you also pass on these instructions for use.
Safety Information
Only use the unit for the specific purpose desc-
rybed in the instruction manual. Any misuse will void the warranty.
A control measurement using a conventional
thermometer is recommended in the following cases:
1. If the reading is surprisingly low.
2. For new-born infants up to 100 days old.
3. For children under three years of age who have a weakened immune system or who react un­usually in the presence or absence of fever.
4. If you are using the thermometer for the first time or want to familiarize yourself with it
The unit is not designed for commercial use. Using this thermometer is not substitute for co-
nsulting a doctor.
The unit is designed for indoor use. This unit is intended measure body temperature. Please put the monitor sensor on armpit at least
10 minute when monitor the temperature
This device is not designed to be used by per-
sons (including children) with limited physical, sensory or mental abilities, or by persons with insufficient experience and/or knowledge, un­less under observation by a person responsible for their safety, or unless they have been instru­cted in the use of the device.
The patient is an intended operator
Children must be supervised to ensure that they
do not play with the device.
If a fault occurs or the unit is damaged, do not
attempt to repair the unit yourself, as this will void the warranty. Contact your dealer and only have repairs carried out by authorized service partners.
Do not open up the device. It contains small
parts which might be swallowed by children.
Do not use the thermometer in damp environ-
ments.
Do not immerse the thermometer in water or
other liquids. It is not watertight.
Do not shake or tap the thermometer. Do not
drop it.
Protect the device from direct sunlight, extre-
mely high or low temperatures, dirt and dust.
Do not use or store the unit in an environment
where the ambient temperature or humidity is too high or too low (see operating conditions in the “Technical specifications” section)
If the device is not going to be used for a long
period, remove the batteries.
Avoid using any kind of sharp object to touch
the device. Do not disassemble or modified.
Banned in high radiation environments or high
concentrations of flammable gases or nitrous oxide environment using this device.
The device should not both use with CT or MRI. Do not use the thermometer if it is damaged. When monitor the temperature, Must regularly
check the contact with the skin, avoid measure­ment errors.
The wireless transmission range may be affected
when obstructions or body height shelter
It may result in inaccurate measurements when
sudden movements or low battery power.
This device should not be used continuously for
more than 12 hours. when feel uncomfortable, please stop using and remove the device.
Only get genuine Parts from the original
supplier.
Before each use and after use, please clean the
device follow the instructions Cleaning and Maintenance
If the temperature measurement result is
abnormal, please consult your doctor.
A warning against servicing and maintenance
while the equipment is in use
BATTERY SAFETY INFORMATION
If a battery has been swallowed seek medical
attention immediately!
Do not disassemble batteries! Clean the battery and device contacts if
necessary before putting in the batteries!
Remove discharged batteries from the device
immediately!
Increased risk of leakage, avoid contact with skin,
eyes and mucous membranes! If battery acid comes in contact with any of these parts, rinse the affected area with copious amounts of fresh water and seek medical attention immediately! Insert the batteries correctly, observing the polarity!
Keep the battery compartment well sealed! Remove the batteries if you do not wish to use
the unit for an extended period of time. Otherwise there is a danger that the batteries may leak.
Keep batteries out of children's reach! Do not attempt to recharge these batteries!
There is a danger of explosion!!!!
Do not short circuit! There is a danger of
explosion!!!!
Do not throw into a fire! There is a danger of
explosion!!!!
Keep unused batteries in their packaging away
from metal objects in order to prevent short circuiting!
Do not throw used batteries into the household
refuse; put them in a hazardous waste container or take them to a battery collection point, at the shop where they were purchased!
NOTE:
The battery contains the following contaminants: Li (lithium)
Package Contents
Please check the package and the contents are
complete, and no any damage on it.
If in doubt, do not operate the device and associated
with the dealer or Service positions.
1 x Bluetooth thermometer BT-0512 1 x CR2032, 3V button battery 1 x Instructions manual
The packaging is reusable or can be recycled. Observe the environmental protection rules of regarding the disposal when you no longer need the packaging. If you found any damage during open the packing, contact your dealer immediately.
WARNING:
Be sure to put the packaging film out of reach of children. Or it may cause suffocation.
Installing and removing - battery
Install battery before using the device.
Use Phillips screwdriver to remove the screw by anticlockwise rotation, open the battery cover ➐. Then put the battery into the device, be sure the battery is in the correct position. ( POSITIVE (+) IS VISIBLE ) then put pack the battery cover ,and use the Philips screwdriver to lock the screw by clockwise rotation.
Battery drops after a period of use, display will show “,please change the battery
The device is use 1 x CR-2032 , 3V button battery
Download the Application
Download and install the thermometer application on your iOS / Android device.
You can download for free in Apple App Store or Google Play Store
Search « Livan Thermo App »
CAUTION
A typical smart device with a maximum
output power of 2 W yields d = 3.3 m at an immunity level of 3 V/m
Establish a connection
Please turn on your Bluetooth on your iOS or Android device.
Press On/Off on the thermometer at least 3 sec to turn on the thermometer.
Lunch the App on your iOS or Android device and follow the instruction for the application to establish the connection with the Livan Bluetooth thermometer BT-0512, then the devices will be synchronize.
Once the connection has been established, the temperature is show on the screen of the App on your iOS or Android device.
Please turn off your airplane mode and active Bluetooth on your iOS or Android device, or the connection will be not restricted by calls
Measuring the temperature
Please put the steel sensor on aimpit to monitor
the temperature. Hold the position at least 10 min, to ensure correct measurement values.
To ensure a good connection between the
device and the iOS or Android device, the distance between devices should not exceed 5 meters. Connection is more secure, if the devices is located in the ipsilateral of body
In normal Bluetooth connection, the scope can
reach up to 10 m, the scope can be reduced by obstacles. (E.g wall )
The application on the iOS or Android device
will show the measured temperature Value by the thermometer
Instructions
Power ON by On/Off button(Press 3 sec), display
on for 5 sec, blue LED continue ON for 5 sec, then put the sensor of the device on armpit to start monitor the temperature.
The device wll continue monitor the tempera-
ture, when press On/Off button once, the deivce will show the current temperature on display
If the measuring temperature is below 32℃,
there will show »Lo« on the display. If the tem-
perature is higher than 32, the value will be show on the display directly. If the temperature is higher then 42℃, there will show »Hi«.
If the measuring temperature is higher then
38℃, the LED on the device will flash red light for 5 min, then the device will prompted again when the temperature is increased by 0.5
After using, press the On/Off button for 5 sec,
the LED will flash red light for 5 sec, then the device will shutdown to save battery power.
The extra wrist belt is using when the belt on the
thermometer may not long enough to tied.
Note
The applied part is the sensor head.
The device has automatic shutdown when sensor doesnt any temperature measured for 30 min.( below 32).
Cleaning and Maintenance
To clean the thermometer, use a soft cloth
slightly dampened with mild soapy water or 70% isopropyl alcohol. Do not let water get into the unit. Only use the unit again when completely dry.
Never use aggressive cleaning agents, thinners,
benzine or tough brushes.
Remove the batteries if you do not wish to use
the unit for an extended period of time. Otherwise there is a danger that the batteries may leak.
If the thermometer is used as described in these
instructions, no regular maintenance or calibration is required.
CAUTION
Do not immerse the thermometer in water or any other liquid. It is not watertight
Disposal
This product must not be disposed of together with domestic waste. All users are obliged to hand in all electrical or electronic
devices, regardless of whether or not they contain toxic substances, at a municipal or commercial collection point so that they can be disposed of in an environ-mentally acceptable manner.
Please remove the batteries before disposing of the device/unit.
Do not dispose of old batteries with your household waste, but at a battery collection station at a recycling site or in a shop.
Consult your municipal authority or your dealer for information about disposal.
Technical specifications
Name & model :
Livan Bluetooth thermometer BT0512
Power supply :
3V = 1 x CR2032 Button battery
Measuring range :
32℃~42℃
Accuracy of measurement :
±0.1
Operating Conditions :
+5℃~ +40°C(+41°F ~ +104°F) Relative humidity 15-93 Atmospheric pressure 80-106 KPa
Storage & transport conditions :
-25℃ ~ +70°C(-13°F ~ +158°F)
Relative humidity 10-93 Atmospheric pressure 70-106 KPa
Dimensions :
Host : 36mm x 30mm x 11mm Wrist belt :24mm x 220mm (Sensor position : 28mm) Extra belt :24mm x 170mm
Material :
Host : ABS plastic Wrist belt : Velvet Sensor : Steel
Weight :
about 10g (without battery)
Lifetime
2 years
Compatible with :
iOS : 7.0 or higher. Android : 4.3 or higher. Bluetooth 4.0 or higher.
FCC ID
2AHQNBT0512
Article No. :
BT0512-03
Manual No.:
051216001
0434
CE certification of the device refers to the EU Directive 93/42 / EEC.
we declare that the Livan Bluetooth thermometer BT­0512, art. BT-0512-03, respects the fundamental requirements of the European R & TTE Directive 1995/5 / EC.
You can request the complete conformity EC declaration to Livan Technology Co., Ltd.
Recommended separation distances between portable and mobile RF communications equipment and the equipment
The equipment is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communica­tions equipment (transmitters) and the equipment as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter ( W )
Separation distance according to frequency of transmitter ( m )
800 MHz to 2.5 GHz
0.01
0.23
0.1
0.73
1
2.3
10
7.3
100
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
In accordance with our policy of continual product
improvement, we reserve the right to make technical and optical changes without notice.
Electromagnetic compatibility
The device complies with the EN 60601-1-2 standard for electromagnetic compatibility.
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or tele-
vision reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
CAUTION: To assure continued FCC compliance:
Any changes or modifications not expressly approved by the
grantee of this device could void the user's authority to operate
the equipment.
FCC Label Compliance Statement:
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference.
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Exposure to Radio Frequency Radiation:
This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This transmitter must not
be co-located or operating in conjunction with any other antenna
or transmitter.
Livan Technology Co., Ltd
3F., No.3, Ln. 133, Baozhong Rd., Xindian Dist., New Taipei City 23144, Taiwan(R.O.C) E-mail: info@livan-co.com
Loading...