Linear WOR User Manual

0 (0)
Linear WOR User Manual

WOR

Wiegand

Output

Receiver

Installation

Instructions

(760) 438-7000 • FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

1.OPEN CASE

OPEN CASE FROM

ANTENNA END

BOARD SLIDES OUT

 

FROM 3RD SLOT UP

REMOVE FOUR

INSIDE CASE

SCREWS AND WASHERS

3.SET VOLTAGE INPUT JUMPER

PLACE VOLTAGE INPUT JUMPER

 

IN THIS POSITION TO SELECT A

PLACE VOLTAGE INPUT JUMPER

8-24 VOLT DC INPUT FROM THE

IN THIS POSITION TO SELECT A

ACCESS CONTROL PANEL

REGULATED 5 VOLT DC INPUT

 

FROM THE ACCESS CONTROL

 

PANEL

5.SET TRANSMITTER FACILITY CODE

SET XMTR FACILITY CODE SWITCHES TO MATCH THE FACILITY CODE PRE-PROGRAMMED INTO TRANSMITTER BLOCK

XMTR FACILITY

 

SWT0

 

SWT1

 

SWT2

 

SWT3

 

 

 

 

 

 

CODE SWITCHES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

TRANSMITTER BLOCK

5

 

 

 

 

 

 

 

 

FACILITY CODE 0-15

6

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

(ASSIGNED WHEN

 

8

 

 

 

 

 

 

 

 

TRANSMITTER BLOCK IS

9

 

 

 

 

 

 

 

 

ORDERED FROM LINEAR)

10

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

=SWITCHON

12

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

=SWITCHOFF

14

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

NOTE: THE FACTORY SETTINGS

 

 

 

 

 

 

 

 

 

OF FACILITY CODE "0" WILL

 

 

 

 

 

 

 

 

 

ALLOW VALIDATION OF ANY

 

 

 

 

 

 

 

 

 

TRANSMITTER FACILITY CODE

 

 

 

 

 

 

 

 

 

INTRODUCTION

The Model WOR remote radio receiver is designed for use as an access control interface for Linear’s block coded digital transmitters. The unit receives signals from transmitters, adds a facility code to the data, and sends the information to the Wiegand input of the access control panel via a 5-wire connection.

Several transmitter and receiver options can be set using the unit’s dipswitches. Three different Wiegand output formats (26, 30, & 31-bit) are supported. Three receiver options (lockout, hold, & button offset) can be set. Transmitter buttons on multi-button units can be selectively disabled. The facility code is set using 16 dipswitches.

Three antenna types can be used with this receiver. The local whip antenna (supplied) screws directly on to the receiver. The directional (EXA-2000) and omni-directional (EXA-1000) remote antennas attach to the receiver’s antenna input via RG-59 cable and a type “F” connector.

An on-board RADIO RANGE knob allows adjustment of the receiver’s gain. It can be set to limit the maximum radio range that the receiver can achieve. Two indicators display the receivers performance and operation. The red RADIO indicator lights when the receiver detects a radio signal. The two color red/green STATUS indicator lights green when the receiver is sending Wiegand data and during the 1-second post receiver lockout timer (if receiver lockout is enabled). The indicator turns red when the receiver’s HOLD input (connected to the access control panel) is active. Receiver test points are provided for listening to the incoming signals with an audio amplifier.

Power input to the receiver can be either regulated 5 volts or 8-24 volts DC (jumper selected).

The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements.

2.LOCATE COMPONENTS

 

ANTENNA

RADIO RANGE KNOB

CONNECTOR

(HIDDEN)

(CLOCKWISE FOR

 

MAXIMUM GAIN)

 

 

INPUT

MAX

VOLTAGE

JUMPER

 

 

PROGRAM

 

BUTTON

OPTION

DIPSWITCHES POWER AND DATA TERMINALS

RADIO

GND

AUDIO

STATUS INDICATOR

RED = HOLD, GREEN = DECODE

 

 

TEST POINTS

RADIO INDICATOR

4.SET OUTPUT FORMAT & RECEIVER OPTIONS

WIEGAND OUTPUT FORMAT

SWITCH 1 26-BIT SELECT THE WIEGAND OUTPUT FORMAT

SWITCH 2 30-BIT THAT MATCHES THE ACCESS CONTROL

SWITCH 3 31-BIT SYSTEM BEING USED

BUTTON OFFSET TABLE

LEFT

RIGHT

TOP

BOTTOM LEFT OR RIGHT

0

16384

32768

49152

 

 

 

 

RECEIVER OPTIONS

SWITCH 1 - LOCKOUT DISABLE

OFF - (FACTORY SETTING) CAUSES RECEIVER TO IGNORE TRANSMITTER SIGNALS FOR ONE SECOND AFTER A VALIDATED TRANSMISSION. ON - ALLOWS RECEIVER TO PASS WIEGAND DATA INSTANTLY WITH EACH VALIDATED TRANSMISSION.

SWITCH 2 - HOLD ENABLE

OFF - (FACTORY SETTING) HOLD INPUT SIGNALS ARE IGNORED.

ON - WHEN HOLD INPUT IS ACTIVE, ANY WIEGAND DATA WILL BE HELD FOR A MAXIMUM OF ONE SECOND THEN DISCARDED UNLESS THE HOLD INPUT IS RELEASED DURING THE ONE SECOND TIME.

SWITCH 3 - BUTTON OFFSET ENABLE

OFF - (FACTORY SETTING) TRANSMITTERS PASS THEIR ID NUMBER TO THE WIEGAND OUTPUT WITHOUT ANY CHANGES. ON - THE TRANSMITTER ID IS OFFSET TO THE RANGE ABOVE, BASED ON WHICH BUTTON IS PRESSED.

6.SET TRANSMITTER BUTTON OPTIONS

 

BOTH

 

 

FUNCTION

 

AS LEFT

TOP

 

BUTTON

BUTTON

 

LEFT

RIGHT

 

BUTTON

 

BUTTON

 

TOP

 

BUTTON

 

 

 

RIGHT

LEFT

BUTTON

BUTTON

 

BOTTOM-RIGHT

BOTTOM-LEFT

 

 

BUTTON

BUTTON

 

 

 

 

RIGHT

 

 

BUTTON

LEFT

LEFT

BUTTON

BUTTON

 

THE FACTORY SETTING ALLOWS ALL

TRANSMITTER BUTTONS TO OPERATE

SET XMTR BUTTON DISABLE SWITCH(ES) ON TO PREVENT SELECTED TRANSMITTER BUTTONS FROM OPERATING

SWITCH 4 - TOP

SWITCH 5 - BOTTOM RIGHT

OPERATE

SWITCH 6 - BOTTOM LEFT

AS TOP

SWITCH 7

- RIGHT OR TOP RIGHT

BUTTON

 

SWITCH 8

- LEFT OR TOP LEFT

Loading...