SECTION 2/Folio G05-30 REV. A

 

VP PARABOLIC VPA2G27PP332

Page 1 of 2

2'x4' RECESSED FLUORESCENT, 4" DEEP, 27 CELL (3x9) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)

Features

Meets IES RP1 for lighting VDT areas with intense use.

66% efficient (T8).

1.5 spacing mounting ratio.

Only 6" deep body.

One-piecehousing.

Specular low iridescence pre-anodizedlouver.

Spring-loadedlatches.

Concealed “T” hinges.

Louver frame with integral positive light stop.

Earthquake clips included.

Louver has protective film dust guard.

Air closure strips (optional).

Air flow pattern dampers (optional).

UL-Listedtwin knockout access plate.

Construction to meet Chicago Plenum Code is available.

MOUNTING METHODS

G exposedT-gridceiling.

 

 

 

 

1/4" max.

 

 

 

 

1-1/2"max.

 

 

24"

15/16"

 

 

 

 

 

or 1"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

concealed Z-splineceiling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-

1/8" min.

 

 

 

24-11/16"

3-

3/4" max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

plaster ceiling/flanged.

 

 

 

 

 

 

 

 

 

 

 

 

 

1-

1/8" min.

 

 

 

 

3-

3/4" max.

 

 

24-11/16"

13/16"

 

 

 

 

 

 

 

 

 

 

 

T exposed slotT-gridceiling.

 

 

 

1-7/8"max.

 

 

24"

9/16"

 

 

 

 

 

 

 

 

direct concealed two directional

 

T

 

T-gridceiling. (see options for

splay trim).

1/4" max.

1-7/8"max.

24"

drywall kit (see options).

Type “G”

Fixture

Support (by others)

Drywall (by others)

Ceiling

24-5/16"

15/16"

Opening

 

 

DIMENSIONS

 

 

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

24" (610mm)

 

 

 

 

 

 

 

6" (152mm)

 

 

 

 

 

 

 

 

2"x2-1/2"access plate

 

 

 

 

 

 

 

Air supply slots

 

 

 

 

 

 

 

 

 

 

 

 

 

with two K.O.s (7/8" dia.)

 

(VPA only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-1/2"(89mm)

39-1/4"(997mm)

47-31/32"(1218mm)

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

Lightolier a Genlyte Thomas Company www.lightolier.com Technical Information: (978)657-7600• Fax (978)658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131• Fax (508)674-4710We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

SECTION 2/Folio G05-30 REV. A

 

VP PARABOLIC VPA2G27PP332

Page 2 of 2

2'x4' RECESSED FLUORESCENT, 4" DEEP, 27 CELL (3x9) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)

PHOTOMETRY

 

 

LER = FP - 46.1

IW - 116.4

BF - 95.1

 

 

 

 

 

 

 

 

 

MODEL NO. VPA2G27PP332O3 Comparative yearly lighting energy cost per 1000 lumens = $5.20

 

 

 

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

 

RF

 

20

 

 

 

 

 

20

 

 

 

 

 

 

20

 

 

 

RC

 

80

 

 

 

 

 

50

 

 

 

 

 

 

30

 

 

 

RW

70

50

 

30

 

 

50

30

 

 

10

 

50

 

30

10

 

 

ratio

1

74

72

 

70

 

 

68

67

 

 

65

 

66

 

64

63

 

 

3

65

60

 

56

 

 

57

54

 

 

52

 

56

 

53

51

 

 

 

2

70

66

 

63

 

 

63

60

 

 

58

 

61

 

59

57

 

 

cavity

4

61

55

 

51

 

 

53

49

 

 

46

 

51

 

48

46

 

 

5

57

50

 

46

 

 

48

45

 

 

42

 

47

 

44

41

 

 

room

6

53

46

 

41

 

 

45

41

 

 

38

 

44

 

40

37

 

 

8

47

39

 

34

 

 

38

34

 

 

31

 

37

 

33

31

 

 

 

7

50

42

 

38

 

 

41

37

 

 

34

 

40

 

37

34

 

 

 

9

44

36

 

32

 

 

35

31

 

 

28

 

34

 

31

28

 

 

 

10

41

34

 

29

 

 

33

29

 

 

26

 

32

 

28

26

 

 

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

W

 

L

8.5

10.0

13.0

16.0

 

 

 

 

8.5

10.0

13.0

16.0

 

 

 

20

 

20

 

 

 

89

 

95

92

83

 

 

 

 

97

97

97

90

 

 

20

 

30

 

 

 

90

 

95

93

83

 

 

 

 

97

97

97

91

 

 

20

 

40

 

 

 

90

 

95

93

83

 

 

 

 

97

97

97

91

 

 

20

 

60

 

 

 

90

 

95

93

83

 

 

 

 

97

98

97

91

 

 

 

30

 

20

 

 

 

90

 

95

93

86

 

 

 

 

97

97

97

92

 

 

30

 

30

 

 

 

90

 

95

93

86

 

 

 

 

97

98

97

92

 

 

30

 

40

 

 

 

90

 

95

93

86

 

 

 

 

97

98

97

92

 

 

30

 

60

 

lengthwise

 

90

 

95

93

87

 

 

 

crosswise

97

98

97

92

 

 

40

 

40

 

 

90

 

95

93

87

 

 

 

97

98

97

92

 

 

30

 

80

 

 

 

90

 

95

93

87

 

 

 

 

97

98

97

92

 

 

 

40

 

20

 

 

 

90

 

95

93

86

 

 

 

 

97

97

97

92

 

 

40

 

30

 

 

 

90

 

95

93

86

 

 

 

 

97

98

97

92

 

 

40

 

60

 

luminaries

 

90

 

95

93

87

 

 

 

luminaries

97

98

97

92

 

 

40

 

80

 

 

90

 

95

93

87

 

 

 

97

98

97

92

 

 

40

 

100

 

 

 

90

 

95

93

87

 

 

 

 

97

98

97

92

 

 

 

60

 

30

 

 

 

90

 

95

93

86

 

 

 

 

97

98

97

92

 

 

60

 

40

 

 

 

90

 

95

93

87

 

 

 

 

97

98

97

92

 

 

60

 

60

 

 

 

90

 

95

93

87

 

 

 

 

97

98

97

92

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

80

 

 

 

91

 

95

91

87

 

 

 

 

97

98

97

92

 

 

60

 

100

 

 

 

91

 

95

91

87

 

 

 

 

97

98

98

93

 

 

 

100

 

40

 

 

 

90

 

95

93

87

 

 

 

 

97

98

97

92

 

 

100

 

60

 

 

 

91

 

95

91

87

 

 

 

 

97

98

97

92

 

 

100

 

80

 

 

 

91

 

95

91

87

 

 

 

 

97

98

98

93

 

 

 

100

 

100

 

 

 

91

 

95

91

87

 

 

 

 

97

98

98

93

 

ORDERING INFORMATION

Explanation of Catalog Number. Example: VPA2G27PP332120O3GLR

 

VP

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

P

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOUVER

 

 

 

 

 

 

 

 

 

BODY

STYLE:

 

 

CEILING TYPE:

 

 

 

 

 

 

LAMP

 

 

 

 

 

 

 

 

A=Air Handling

 

 

G= Grid

 

 

 

FINISH*:

 

 

 

QUANTITY

 

 

 

 

 

 

 

 

S=Static

 

 

 

(lay-inT bar)

 

 

 

P=Low

 

 

 

 

 

 

 

 

 

 

 

VP:

 

 

 

 

 

 

 

 

F=Flanged

NUMBER OF

Iridescence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIXTURE

DUAL “V”

 

 

 

 

LAMP TYPE/

 

4" Deep Pre-

 

 

 

 

 

WIDTH

(overlap)

CELLS:

Specular

REFLECTORS

 

 

 

 

FIXTURE

 

 

 

 

 

 

 

Z spline and

 

 

 

 

 

 

 

 

anodized

 

 

 

 

 

 

 

 

(3 rows of

 

 

 

 

 

 

 

 

 

 

LENGTH:

 

 

 

 

 

 

 

 

 

plaster frame

 

 

 

 

 

 

 

 

 

 

 

Aluminum

 

 

 

 

 

 

 

 

9 cells)

 

 

 

 

 

 

 

 

 

 

32=T8

 

 

 

 

 

 

 

 

T=Slot grid or

 

 

 

 

 

 

 

 

 

 

 

Louver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34=T12

 

 

 

 

 

 

 

 

 

two-directional

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Intense

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Nominal 48")

 

 

 

 

 

 

 

 

 

concealed T

 

 

 

 

 

 

 

 

 

 

 

 

 

VDT Use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see options)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE:

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONS:

 

 

120 or 277

 

 

Add appropriate

 

 

 

 

 

 

 

 

suffix to catalog

 

 

 

 

 

 

 

 

 

 

 

 

no, ie: (GLR)

 

 

 

 

 

 

 

 

BALLAST TYPE:

 

 

 

 

 

1 & 2 Lamp Mag. T12

 

LE

<10THD

 

 

 

 

 

<20THD

 

 

1 & 2 Lamp Elec. T8

 

SO*

 

HI*

 

 

1-3Lamp Elec. T8

 

O3*

 

H3*

 

 

LOL T8 Dimming

 

PS

 

 

 

*Instant Start Standard

Other dimming options consult factory.

OPTIONS & ACCESSORIES

PLASTER FRAME: Catalog Number: PF24.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM(each joint). SPLAY TRIM:For T ceiling type only. SUFFIX: CTZ24 S2 SPLAY TRIM.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

AIR CLOSURE STRIPS: SUFFIXACS4 (factory installed).

DRYWALL KIT: Order Catalog Number:FK92X4. Request FolioOA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 3 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .72 with a spacing to mounting ratio of 1.5 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort probability) shall not be less than 90 either crosswise or lengthwise and the maximum average brightness at 55°, 65°, 75° and 85° shall not exceed 745, 0, 0 and 0 candelas per square meter respectively in the 0°, 45°, and 90° horizontal planes.

AIR HANDLING: (VPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal).

FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence specular anodized vertical grain aluminum reflector sheet is standard.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL andC-UL.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

Type:

 

 

 

 

 

 

 

 

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

 

 

Technical Information: (978) 657-7600• Fax (978)658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131• Fax (508)674-4710We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902