2 Light T8 Direct/Indirect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight = 3.0 lb./ft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering Information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Family

Distribution

 

Lamp Type

 

 

No. of Lamps

Housing

Module Length

 

Wiring

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BSL

 

 

6

 

 

T

 

 

 

02

 

 

CN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 = Direct/

 

T = T8

 

 

02 = 2 Light

 

CN = Cutout

 

04 = 4’

 

1 = 1cct.

 

1 = 120V

 

 

 

 

 

 

 

 

 

 

 

 

 

Indirect

 

 

 

 

 

 

 

 

w/baffles

 

08 = 8’

2 = 2cct.

2 = 277V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 = 12’

3 = 1cct. w/EC/NL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

= 2cct. w/EC/NL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

= 1cct. w/EM Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

= 2cct. w/EM Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

= 1cct. w/Dimming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

= 1cct. w/1cct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thru wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

= 2cct. w/1cct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thru wire

 

Note: Please consult wiring section of spec sheets for more wiring options.

 

 

Ballast

Finish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E = Standard

 

C = Custom Color

 

 

 

 

<20% THD

W = Standard

 

F = Standard

White

 

 

<20% THD

 

 

 

 

w/fusing

 

 

 

G = <10% THD,

 

 

 

 

Instant Start

 

 

 

H = <10% THD,

 

 

 

 

Instant Start

 

 

 

 

w/fusing

 

 

 

J = <10% THD,

 

 

 

 

Program Start

 

 

 

K = <10% THD,

 

 

 

 

Program Start

 

 

 

 

w/fusing

 

 

Specifications

Features

1.Housing: die-formed 20ga. cold rolled steel

2.End Set: die-cast metal with baked powder coat finish

3.Lamping: two T8 lamps

4.Configuration: 4’, 8’ and 12’ module lengths or continuous rows

5.Ballasts: electronic 120V or 277V

Finish

High-quality white powder coat with textured matte finish.

Custom colors available. Consult factory.

Mounting

Aircraft cable gripper is tamper-resistant and provides infinite vertical adjustment capability. Aircraft cable, crimp and cable gripper independently tested to meet stringent safety requirements.

Electrical

All luminaires are factory pre-wired to module ends with quick-wire connectors.

Joints & Intersections

Self-aligning joining system with hands-free pre-joining wire access.

Labels

UL, CSA standards.

Ordering Instructions

Individual Fixtures

1.Determine the number of individual modules required

2.Order one end set per module

3.Order one non-power mount per module

4.Order one power mount per module

Continuous Rows*

1.Determine run length

2.Order the appropriate number and length of modules for complete run

3.Order one end set for each run

4.Order one non-power mount for each module

5.Order one power mount per run

6.Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)

*Note: Some runs may require additional power mounts. Please see the ‘Run Configuration’ table on next page for more details.

 

 

 

 

 

Job Information

Type:

 

 

 

 

 

 

 

 

 

 

 

 

Job Name:

Cat. No.:

Lamp(s):

Notes:

Lightolier a Genlyte Company www.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Lighting SystemsBaselyte-BSL1

Page

 

of 8

 

 

 

 

 

 

 

Performance

 

 

 

 

 

 

 

Candlepower Curve

Candlepower Summary

 

 

 

 

 

 

 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

 

 

DEG.

0

22.5

45

67.5

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

1045

1045

1045

1045

1045

 

 

 

 

 

175

1040

1038

1038

1035

1037

 

 

 

 

165

1001

994

1000

1003

1006

 

 

 

 

155

931

922

942

949

957

 

 

 

 

145

831

826

863

906

925

 

 

 

135

693

705

788

855

884

 

 

 

 

 

125

544

569

700

795

827

 

 

 

 

 

 

 

 

115

376

434

596

673

706

 

 

105

205

299

448

501

545

 

 

 

 

 

 

 

 

 

95

48

117

187

172

214

 

 

 

 

90

5

20

35

42

47

 

 

 

 

 

 

 

 

 

85

15

26

42

48

51

 

 

 

 

 

 

 

 

 

75

43

46

55

68

73

 

 

 

 

 

 

 

 

 

 

65

86

99

86

72

76

 

 

 

 

 

 

55

185

163

155

131

128

 

 

Report No: 2101580

45

300

249

227

212

212

35

412

354

314

281

286

Lamps: F32T8

25

515

463

437

384

384

Lumens per Lamp: 2950

15

598

567

548

515

516

Efficiency: 82.1%

5

646

637

636

619

623

Up: 76.9% Down: 23.1%

0

651

651

651

651

651

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH , -OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

2 Light T8 Direct/Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

82

82

82

73

73

73

 

56

56

56

1

72

69

66

64

61

59

 

49

47

46

2

63

58

54

56

52

49

 

43

40

38

3

55

50

45

49

45

41

 

38

35

32

4

49

43

38

44

39

35

 

34

30

27

5

44

37

33

39

34

30

 

30

26

24

6

39

33

28

35

30

26

 

27

23

21

7

35

29

25

31

26

22

 

25

21

18

8

32

26

22

29

23

20

 

22

19

16

9

29

23

19

26

21

18

 

20

17

14

10

26

21

17

24

19

16

 

19

15

13

Zonal Lumen Summary

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

1117

18.9

23.1

90-180

3728

63.2

76.9

0-180

4845

82.1

100.0

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

 

 

 

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Dust Cover

BSLDCS = 4’ suspended dust cover

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

Type:

 

 

 

 

 

 

Lightolier a Genlyte Company

www.lightolier.com

 

 

 

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Lightolier BSL1 User Manual

 

Lighting SystemsBaselyte-BSL1

Page of 8

2 Light T8 Direct/Indirect

Mounting Options

Mount Type: T-Bar 15/16” (On-Grid)*

65 lbs maximum load

Canopy: Diameter of 3 3/4“x 7/32”

Cable: 7x7 stranded aircraft cable

Supported by T-bar and secured to structure

J-Box: 4” square (supplied by others)

Fully adjustable vertically at fixture

1-Power Mount Non-Power Mount

 

 

Supension Length

 

1-Power Mount

 

 

 

 

2’

4’

8’

12’

 

 

 

 

 

3 Conductor

BSLM6102P13

BSLM6104P13

BSLM6108P13

BSLM6112P13

 

 

 

 

 

4 Conductor

BSLM6102P14

BSLM6104P14

BSLM6108P14

BSLM6112P14

 

 

 

 

 

7 Conductor

BSLM6102P17

BSLM6104P17

BSLM6108P17

BSLM6112P17

Non-Power Mount

 

 

 

 

 

 

 

 

BSLM6102N

BSLM6104N

BSLM6108N

BSLM6112N

 

 

 

 

 

Mount Type: T-Bar 9/16” (On-Grid)*

65 lbs maximum load

Canopy: Diameter of 3 3/4“x 7/32”

Cable: 7x7 stranded aircraft cable

Supported by T-bar and secured to structure

J-Box: 4” square (supplied by others)

Fully adjustable vertically at fixture

1-Power Mount Non-Power Mount

 

 

Supension Length

 

 

 

 

1-Power Mount

 

 

 

 

 

 

 

2’

4’

8’

12’

 

 

 

 

 

 

 

 

 

 

 

3 Conductor

BSLM6202P13

BSLM6204P13

BSLM6208P13

BSLM6212P13

 

 

 

 

 

 

 

 

 

 

 

4 Conductor

BSLM6202P14

BSLM6204P14

BSLM6208P14

BSLM6212P14

 

 

 

 

 

 

 

 

 

 

 

 

 

7 Conductor

BSLM6202P17

BSLM6204P17

BSLM6208P17

BSLM6212P17

 

 

 

Non-Power Mount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BSLM6202N

BSLM6204N

BSLM6208N

BSLM6212N

 

 

 

 

 

 

 

 

 

 

 

Mount Type: T-Bar 9/16” by 5/16” Slot Grid (On-Grid)*

65 lbs maximum load

Canopy: Diameter of 3 3/4“x 7/32”

Cable: 7x7 stranded aircraft cable

Supported by T-bar and secured to structure

J-Box: 4” square (supplied by others)

Fully adjustable vertically at fixture

*Note: Standard T-bar mounts are currently not available for tegular tile ceilings, however certain tegular tile / T-bar combinations may be supported by the use of the slot-grid mount. For more information, please consult factory.

1-Power Mount Non-Power Mount

 

 

 

 

Supension Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-Power Mount

 

 

 

 

 

 

 

2’

 

4’

8’

12’

 

 

 

 

 

 

 

 

 

3 Conductor

BSLM6302P13

BSLM6304P13

BSLM6308P13

BSLM6312P13

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Conductor

BSLM6302P14

BSLM6304P14

BSLM6308P14

BSLM6312P14

 

 

 

 

 

 

7 Conductor

BSLM6302P17

BSLM6304P17

BSLM6308P17

BSLM6312P17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-Power Mount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BSLM6302N

BSLM6304N

BSLM6308N

BSLM6312N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

Type:

 

 

 

 

 

 

 

 

 

Lightolier a Genlyte Company

 

 

www.lightolier.com

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Loading...
+ 5 hidden pages