D1 Wiring Type
CONVERSION INSTRUCTIONS
MODELS: T, GT, J, H, GH, SD, GSD
Instructions to convert a standard control box with type C2 / B2 control wiring to type D1 control wiring
Type D1 wiring Function: Constant contact to open and close with wiring for sensing device to stop
Locate terminal block in electrical control box.
Ensure C2 / B2 control jumper (red) wire is
positioned on terminal # 2 for (C2) constant
pressure to close.
Disconnect orange wire between terminal #7 and
R1 Relay normally open contact at Relay side and
tape end to terminate connection. Note: keeping
this wire will allow for reverting back to B2 / C2
wiring type in the future. Remove and discard wire
if desired.
Place a jumper between terminals #3 and #4.
SCHEMATIC DIAGRAM
Disconnect power to the operator(s) before
making control wiring modification.
Terminate
Connection between
terminal #7 and R1
Relay N.O. contact
Move yellow wire from
terminal #3 to #1
© 1998, The Chamberlain Group, Inc.
01-11969B All Rights Reserved
Place existing C2/B2
red wire on terminal #2
quick connect
Add Jumper between
terminal #3 and #4.