Lift-Master WOMODKT User Manual

0 (0)
J500
H2
100A
UD
H2
100A
J406 LCD
J403
D2
3D2
100
16B
3D2
100
16B
3D2
16B
100A
3D2
100
16B
DEVICE 1,2
J401
D300
J402 LED
J200 SPKR
BT300
DEVICE 3,4
J405
for EL models
Model WOMODKT
Wiegand Module
J400
Position
J407
Position
Wiegand Module
2 modules can be mounted in the EL model.
Supporting up to 4 Wiegand devices.
Caution! A static discharge can
DAMAGE circuit boards.
© 2006 The Chamberlain Group, Inc.
All Rights Reserved
114A2970C
Callouts
Under Connector
®
J407 J400
J500
H2
100A
UD
H2
100A
UD
3D2
100
16B
J406 LCD
J201
MIC
J403
D2
D102
D153
3D2
100
16B
3D2
100
16B
3D2
100
16B
H2
100A
UD
3D2
100
16B
J400
+
DEVICE 1,2
J407
J401
D300
D513
D514
OV
UV
J404
J402 LEDJ200 SPKR
J300
BT300
DEVICE 3,4
SW300
J405
J301
Disconnect power to your unit! Unlock and open the unit.
1
Place Wiegand module(s) in J400 Plug - Device 1(J1)and 2(J2) and/or J407 Plug - Device 3(J1) and 4(J2) (4 screws per board).
2
All wires MUST go through the conduit hole in the back mounting plate of unit.
Connect the shield wire from the device(s) to the backplate or earth ground rod. Some Wiegand devices have a sixth blue wire.
DO NOT connect this blue wire to the unit. Insulate this wire from the unit to prevent a short (refer to instructions supplied with
the Wiegand device for more information). When using an Essex keypad (Chamberlain model # ESSWOKSG), do not connect the brown
LED control wire. Connecting this wire will cause the keypad to work intermittently.
3
Wiring callouts are under removable wire connectors.
After the installation is complete, each device connected to the Wiegand Module(s) must be tested by swiping a card or entering a digit
once, so that the new module is automatically detected. You can then go into programming and assign your devices to the doors.
4
+12V
+5V
DATA 0
DATA 1
LED
COM .12V
.5V
DATA 0
DATA 1
LED
COM
J1J2
+12V
+5V
DATA 0
DATA 1
LED
COM .12V
.5V
DATA 0
DATA 1
LED
COM
J1J2
+12V
+5V
DATA 0
DATA 1
LED
COM
J1
J2
Device
2 or 4
Device 4 Device 3 Device 2 Device 1
Loading...