LG TD-V14247E, TD-V10247G, TD-V14247G User Manual

0 (0)

TD-V10247G

TD-V14247E

TD-V14247G

Thank you for buying an LG Dryer.

Please read your manual carefully, as it provides instructions on safe Installation, use and maintenance.

Record the model and serial numbers, and retain the manual for future reference.

P/No.: 3828EL3004P

PRODUCT FEATURES

1

OUTSTANDING PERFORMANCE

Not to mention unmatched big capacity, you can benefit from good time efficiency, quiet operation and energy saving system.

2

ARTISTIC DESIGN

Modern front panel look and big crystal-clear glass door make your house look stylish.

3

DIGITAL FABRIC CARE

Multi-level temperature control heater takes a better care on your valued clothes.

4EASY OF USE

A whole selection of user-friendly functions always make you comfortable with dryer operation.

What are Sensor Dry and Time Dry?

Your dryer provides sensor drying and time drying programs.

Sensor Dry

The dryer senses the dampness of the laundry and automatically determines the heat level and operation time. You might see a sudden increase or decrease in operation time if the sensor determines more or less drying is required. This is not a malfunction.

Time Dry

Use TIME DRY to select heat level and drying time manually. This can be used if clothes are not as dry as you like them at the end of the cycle. Use TIME DRY for heavy and bulky items and thick work.

2

Part 1 SPECIFICATIONS

Type : Electric and Gas Dryer

Rating : Please refer to the rating label regarding detailed information.

Size : 686 x 761 x 983(mm)

Capacity : Please refer to the rating label regarding detailed information.

Weight : 57.2 kg

Specifications are subject to change by manufacturer.

■ ACCESSORIES

 

 

 

 

 

 

 

 

 

 

 

Design of pedestals is subject to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

change without manafaturers notice.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stacking Kit

 

 

Pedestal

 

Purchased Separately

 

 

 

Purchased Separately

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See page 16 for instructions.

 

See page 17 for instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS

SEEKING WARRANTY SERVICE

WARNING!

For your safety, the recommendations in this manual must be followed. To reduce the risk of fire or explosion, electric shock or to prevent property damage, personal injury, or death when using your appliance follow basic precautions.

4

Part 2 IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

Your Safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word DANGER or WARNING. These words mean:

DANGER You can be killed or seriously injured if you don’t Immediately follow instructions. WARNING You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how the reduce the chance of injury, and tell you what can happen if the instructions are not followed.

BASIC SAFETY PRECAUTIONS

WARNING To reduce the risk of fire, electric shock or injury to persons when using your appliance, follow basic precautions, including the following :

Read all instructions before using the dryer.

Before use, the dryer must be properly installed as described in this manual.

Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, other flammable or explosive substances as they give off vapors that could ignite or explode.

Do not reach into the dryer if the drum is moving.

Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.

Do not tamper with controls.

Before the dryer is removed from service or discarded, remove the door to the drying compartment.

Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.

Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.

Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.

The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.

Do not install or store the dryer where it will be exposed to the weather.

Do not reach into the dryer while parts are moving.

Always check the inside of the dryer for foreign objects

Clean lint screen before or after each load.

SAVE THESE INSTRUCTIONS

5

Part 2 IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance or any other appliance.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

BASIC SAFETY PRECAUTIONS

WARNING To reduce the risk of fire, electric shock or injury to persons when using your appliance, follow basic precautions, including the following :

GROUNDING INSTRUCTIONS

This appliance must be grounded.

In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance must be equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING - Improper connection of the equipmentrounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the appliance is properly grounded.

Do not modify the plug provided with the appliance.

If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance must be connected to a grounded metal, permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

6

Part 2 IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

WHAT TO DO IF YOU SMELL GAS

WARNING To reduce the risk of fire, electric shock, or injury to persons when using the appliance, follow basic precautions, including the following:

1.Do not try to light a match or cigarette, or turn on any gas or electrical appliance.

2.Do not touch any electrical switches. Do not use any phone in your building.

3.Clear the room, building, or area of all occupants.

4.Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s phone. Follow the gas supplier’s instructions carefully.

5.If you cannot reach your gas supplier, call the fire department.

7

Part 2 IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

SAFETY INSTRUCTION FOR INSTALLATION

WARNING To reduce the risk of fire, electric shock, or injury to persons when using the appliance, follow basic precautions, including the following:

Properly ground dryer to conform with all governing codes and ordinances. Follow details in the installation instructions.

Electrical shock can result if the dryer is not properly grounded.

Before use, the dryer must be properly installed as described in this manual.

Electrical shock can result if the dryer is not properly grounded.

Install and store the dryer where it will not be exposed to temperatures below freezing or exposed to the weather.

All repairs and servicing must be performed by an authorized servicer unless specifically recommended in this Owner's Guide.

Use only authorized factory parts. Failure to follow this warning can cause

serious injury,fire, electrical shock or death.

Do not install the washer in humid spaces to reduce the risk of electric shock.

Failure to follow this warning can cause serious injury,fire, electrical shock or death.

Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.

Improper power circuit can melt, creating electrical shock and/or fire hazard.

Remove all packing items and dispose of all shipping materials properly.

Failure to do so can result in death, explosion, fire or burns.

Place dryer at least 18 in. above the floor for a garage installation.

Failure to do so can result in death, explosion, fire or burns.

8

Part 2 IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

SAFETY INSTRUCTION FOR INSTALLATION (cont.)

Exhaust/Ducting:

Gas dryers MUST be exhausted to the outside.

Failure to follow these instructions can result in fire or death.

The dryer exhaust system must be exhausted to the outside of the dwelling.

The dryer is not exhausted outdoors, some fine lint and large amounts of moisture will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.

Use only rigid metal or flexible metal 4in. Diameter ductwork inside the dryer cabinet or for exhausting to the outside.

Use of plastic or other combustible ductwork can cause a fire. Punctured ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation.

Rigid or semi rigid metal ducting is recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a ULlisted flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time.

Failure to follow these instructions can result in fire or death.

Ductwork is not provided with the dryer, and you should obtain the necessary ductwork locally. The end cap should have hinged dampers to prevent back draft when the dryer is not in use.

Failure to follow these instructions can result in fire or death.

The exhaust duct must be 4 in. (10 cm) in diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer.

Failure to follow these instructions can result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. ¶U For complete details, follow the Installation Instructions.

Failure to follow these instructions can result in fire or death.

9

IMPORTANT WARRANTY AND SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

SAFETY INSTRUCTION FOR CONNECTING ELECTRICITY

WARNING To reduce the risk of fire, electric shock or injury to persons when using the appliance, follow basic precautions, including the following :

Do not, under any circumstances, cut or remove the ground prong from the power cord.

To prevent personal injury or damage to the dryer, the electrical power cord must be plugged into a properly grounded

For personal safety, this dryer must be properly grounded.

Failure to do so can result in electrical shock or injury

Refer to the installation instructions in this manual for specific electrical requirements for your model.

Failure to follow these instructions can create electrical shock and/or a fire hazard.

This dryer must be plugged into a properly grounded outlet.

Electrical shock can result if the dryer is not properly grounded.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

This will prevent shock hazard and assure stability during operating.

The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

Never unplug your dryer by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

The power cord can be cut by any movement of the core, resulting in electrical shock.

Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.

These power cord can melt, creating electrical shock and/or fire hazard.

When installing or moving the dryer, be careful not to pinch, crush, or damage the power cord.

This will prevent injury and damage to the dryer from fire and electrical shock.

1 0

Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER

through the initial steps of setting up your dryer for use. provides important information regarding the preparation and review this entire manual before proceeding with any

concerning electrical connections, gas connections, and of this manual.

STEP 1 Positioning the Dryer.

Choose a location with a solid floor for your dryer. Place the dryer at least eighteen inches above the floor for a garage installation. After placing the dryer in the desired location, please make sure that it has the required clearances shown below. If you are installing your dryer in a manufactured or mobile home, please refer to STEP 9 for additional instructions.

49.8” (126.4 cm)

38.7” (98.3 cm)

27”

29.96”

(76.1 cm)

(68.6 cm)

 

*Most installations require a minimum 51/2 inches. (14 cm) clearance behind the dryer for the exhaust vent with elbow.

Certain minimum clearances are required above, behind, and to the sides of the unit, as shown below. Those required minimum clearances are set forth in the picture below. Please keep the following instructions in mind when installing in a closet or recessed area:

Consider allowing additional clearance for installation and servicing.

Wall, door and floor molding may necessitate additional clearances.

An additional inch of clearance is recommended to minimize noise transfer.

Consider space needed for companion appliances.

For closet installations, the picture below shows the minimum required ventilation openings for the door. A louvered door with comparable ventilation openings is also acceptable.

ventilation

hole

ventilation

hole

Note

Closet Door

Closet-side View

 

Leveling legs should be secured.

All four legs are stably placed on a solid and even floor.

If dryer is not level, laundry may not tumble properly and sensor will not detect accurate humidity information.

When leveling, please be cautious not to injure your fingers and toes.

If you install the dryer on the optional pedstal, it is nessary to level with the pedestal leveling legs.

Closet-front View

1 1

Part 3 INITIAL STEPS FOR INSTALLING YOUR DRYER

Once in position, adjust the leveling legs of the dryer until it is level from left to right and front to back. The leveling legs must remain firmly on the floor and the dryer should not rock. The maximum slope of the dryer from left to right or front to back should not exceed 2.5 cm (1 inch). If the dryer is not level,

STEP 2 Procedure for Reversing the Door

The door on your dryer can be installed to open either to the left or the right. Follow these instructions to reverse the direction in which your door opens:

Note

Door and latch should be aligned at the center when closed.

1

2

3

INSTALLING YOUR DRYER

STEP 3 Connecting the Exhaust

and Venting System.

WARNING!

Use a heavy metal vent.

Do not use plastic or thin foil duct.

Clean old ducts before installing this dryer.

Failure to follow these instructions can result in death or fire.

Note

The exhaust must be vented to the outside. Improper taping and incorrect installation will cause dryer malfunction.

In addition to the following warnings, please refer to manual section on Exhaust Requirements and Maintenance. Warning: The dryer must be vented to the outdoors. Please follow the instructions (and all others in this manual) very carefully. Failure to follow these instructions can result in death or fire.

Do not use plastic or thin foil duct.

Rigid or semi-rigid metal ducting is recommended for use as transition ducting between the dryer and and the wall. In special installations when it is impossible to make a connection with the above recommendations, then a UL-listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect dry time.

Position the dryer such that the exhaust duct run is as short as possible.

Clean old ducts before installing this dryer

The male end of each section of exhaust duct must point away from the dryer.

Use as few elbow joints as possible.

Use duct tape on all duct joints.

Insulate ductwork that runs through unheated areas in order to reduce condensation and lint build-up on pipe walls.

PLEASE BE AWARE THAT FAILURE TO EXHAUST THE DRYER CORRECTLY WILL VOID THE DRYER’S WARRANTY.

ALTERNATE EXHAUST DIRECTIONS

1.Remove screw and exhaust duct. (Use exhaust kit part #3911EZ9131X.)

2-1. Detach and remove the knockout that matches the desired venting direction (Right side not available on Gas Dryers)

2-2. Connect a short piece of duct to the blower housing and attach the duct to the base.

3-1. Insert the male end of a 4" elbow into the female end of a short duct. Tape the joint.

3-2. Insert this assembly elbow first through the hole in the dryer and push the female end of the elbow onto the male end of the blower output shaft. Tape the joint.

1 3

STEP 4 Connection of Gas Supply

(Gas dryer only). In addition to the following, please refer to manual section on Gas Requirements and Instructions.

1.New stainless steel flexible connector. Use this type of connector only if allowed by local codes. Use Design AGA Certified Connector.

2.1/8" NPT Pipe Plug (for checking inlet gas pressure)

3.Equipment Shut-Off Valve Installed within 6’ (1.8 m) of dryer.

4.Iron Pipe. Shorter than 20’ (6.1 m) Use 3/8" pipe.

Longer than 20’ (6.1 m) - Use 1/2" pipe.

5.3/8" N.P.T. Gas Connection.

Note

Make sure the burner orifice is proper for the type of gas you have.

For instance, using LPG with LNG orifice will result in death, fire or explosion. Or using LNG with LPG nozzle will not allow the burner to ignite.

If needed, orifice conversion should be done by a qualified service technician and mark or put the label of the current type of orifice on the dryer.

If changing the orifice, also adjust the gas valve.

1.Confirm that the type of gas available in your laundry room is appropriate for the dryer. The dryer is prepared for Natural Gas with a 3/8" NPT gas connection.

2.Remove the shipping cap from the gas connection at the back of the dryer. Make sure that you don’t damage the threads of the gas connection pipe when you remove the shipping cap.

3.Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector (as noted below, use a new stainless steel flexible connector if allowed by your local codes).

4.Securely tighten all connections between the dryer and your laundry room’s gas supply. Turn on your laundry room’s gas supply and check all pipe connections (both internal and external) for gas leaks with a non-corrosive leak detection fluid. Refer to Part 7 (page 20)

5.For LP (Liquefied Petroleum) gas connection, refer to this manual’s section entitled Gas Requirements and Instructions.

STEP 5 Electrical Plug Connections

Following are several warnings and instructions concerning making the electrical connection for electric dryers. More detailed information concerning the electrical connection is provided in the manual section entitled Electrical Requirements for Electric Dryer.

It is important that you thoroughly review that section and the remainder of this manual, before taking any steps to install or use this dryer.

1.Use only a new UL listed No. 10 (copper wire only) three conductor power supply cord kit rated 240 Volts (minimum) 30 Amperes and labeled as suitable for use in a clothes dryer.

2.A four-wire cord is required for manufactured (mobile) home installations and where local codes do not allow grounding of this appliance through neutral.

3.Electrical Plug Connections.

4.For additional instruction on connecting the dryer to an electrical power source, please refer to this manual’s section on Electrical Requirements and Electric Dryer.

Note

Burner input requirements

If your house is located at the elevations up to 10,000 feet.

Adjusting burner input setting is not needed at this elevation because AGA certifies this dryer will not have any problem with the BTU rating at this altitude.

If your house is above 10,000 feet, you are required to adjust a four percent (4%) reduction of the burner BTU rating indicated on the model/serial rating plate.

WARNING!

Use a new UL listed 30 amp power supply cord.

Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal.

Ground wire (green or bare wire) must be connected to green ground connector.

Securely tighten all electrical connections

See installation instructions for complete instructions.

Failure to do so can result in fire or electrical shock.

STEP 6 Preparation of the Dryer.

Prior to the first use of this appliance, use allpurpose cleaning products or a solution of detergent

STEP 7 Confirming Heat Source

Operation.

Confirming Heat Source in Gas Dryers

Close the door to the dryer drum/drying compartment and, after completing all steps in this manual for proper installation of this dryer, start the dryer on a heat setting. After the dryer starts, the igniter will glow red and the main burner will ignite.

Warning: If all air is not purged from the gas line, the gas igniter may go off before the gas and the main burner have ignited. If this happens, the igniter will re-attempt gas ignition after approximately two minutes.

Confirming Heat Source in Electric Dryers

Close the door to the dryer drum/drying compartment and, after completing all steps in this manual for proper installation of this dryer, start the dryer on a heat setting. The exhaust air or the exhaust pipe should be warm after the dryer has been operating for three minutes.

STEP 8 Dryer Airflow.

Effective dryer operation requires appropriate dryer airflow. The adequacy of the airflow can be measured by evaluating the static pressure.

Static pressure in the exhaust duct can be measured with a manometer, placed on the exhaust duct approximately 2 ft. (60.9 cm) from the dryer. Static pressure in the exhaust duct should not exceed 5/8 inches (1.5 cm). The dryer should be checked while the dryer is running with no load.

Measuring Static pressure

Manometer

Exhaust Duct

MAXIMUM STATIC

PRESSURE IN

WATER COLUMN

5/8 inches (1.5 cm)

1 5

Stacking Kit Installation Instructions

To ensure safe and secure installation, please observe the instructions below.

WARNING!

The weight of the dryer and the height of installation makes the stacking procedure too risky for one person. This procedure should be performed by 2 or more experienced service personnel.

Incorrect installation can cause serious accidents.

Stacking kit

1 Place washer firmly on a stable, even and solid floor.

2 Peel protective paper off the tape from the stacking kit side bracket.

3 Fit the stacking kit side bracket firmly to the side of top plate by attaching the doublesided tape to top plate as picture shows.

Note

4

5

6

7

Secure stacking kit side bracket to the washer with a screw on the back of bracket. Repeat Steps 2, 3, 4 for the other side.

Place the dryer

of the washer by fitting

legs as shown in the picture. Avoid finger

injuries - be careful not to pinch fingers

between the washer and dryer. Slide dryer

slowly backwards to the stopper of kit.

WARNING!

Do not stack a washer on the top of the dryer.

Incorrect installation can cause serious accidents.

Dryer

Washer

Insert the front rail. Push the front rail back to the stoppers of side stacking kit.

Attach both sides of the front kit with screws.

Clean the surface before attaching the brackets and double-sided tape.

1 6

Do not use stacking kit with a gas dryer in potentially unstable conditions like a mobile home.

Pedestal Installation Instructions

The pedestal accessory includes:

Drawer divider (1)

Wrench (1)

Screws (18) †

Retainers (4) ††

† Dryer installation only uses 8 screws

†† For dryer only

Tools Needed for Installation:

Phillips-head screwdriver

Wrench (supplied)

To ensure safe and secure installation, please thoroughly follow the instructions below.

1 To set the dryer to the same height as the washer, fully retract the leveling feet of the dryer by turning them counterclockwise, then turn them clockwise 1-1/2 turns.

NOTE: The appliance and pedestal assembly must be placed on a solid, sturdy, level floor for proper operation.

Retract fully

Then loosen

 

1-1/2 turns

2 Insert the T-clip of the 4 retainers into the dryer base as shown. Press up on the back of the clip and pull outward to lock into place.

T-clip

Retainer

3 Place the dryer on the pedestal. Make sure the front and back feet are in the correct positions. The dryer feet will fit into the innermost positions as shown.

For dryer

For washer/combo

4 Make sure the screws on the pedestal align with the holes in the retainers, then install 4 screws at each corner to securely attach the appliance to the pedestal.

NOTE: If the screws are not installed properly, noise and vibration may result.

Move the appliance to the desired location.

5

Loosen the locknuts on all 4 leveling feet of the

pedestal until you can turn them with the wrench.

Turn clockwise to raise or counterclockwise to lower

until the pedestal is level and all 4 feet are solidly against the floor.

Raise

Lower

6 Securely tighten all locknuts by hand.

NOTE: Noise and vibration may result if locknuts are not tightened.

Be sure to connect the appliances to all water, power, or gas lines and draining or venting connections before operation.

If there is excessive vibration during the first operation after installation, slightly adjust the leveling feet.

Locknut

1 7

Part 5 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS

The following are additional instructions regarding electrical connections and requirements for electric dryers.

Warning: The wiring and grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all applicable local regulations. Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer. Failure to do so can result in fire or electrical shock.

120V/ 240V, 60 Hertz, 3-Wire Installation

Instructions for Grounding of your Electric Dryer:

a)This dryer must be connected to a grounded metal, permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.

b)The dryer has its own terminal block that must be connected to a separate 60 Hertz single phase AC circuit, fused at 30 Amperes (the circuit must be fused on both sides of the line). ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF MAXIMUM RATE VOLTAGE LISTED ON THE NAMEPLATE. DO NOT CONNECT DRYER TO 110, 115, OR 120 VOLT CIRCUIT.

c)If branch circuit to dryer is fifteen feet (4.50 m) or less in length, use U.L. (Underwriters Laboratories) listed No. 10 A.W.G. wire (copper wire only), or as required by local codes. If over fifteen feet (4.50 m), use U.L. (Underwriters Laboratories) listed No. 8 A.W.G. wire (copper wire only), or as required by local codes. Allow sufficient slack in wiring so dryer can be moved from its normal location when necessary.

d)The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of pigtail and gauge of wire must conform to local codes and with instructions mentioned on the following pages.

e)The method of wiring the dryer is optional and subject to local code requirements. Refer to examples on next page.

f)You must select the method by which to wire your dryer according to local code and ordinance requirements. Sample methods are included in the following pages.

Part 5 ELECTRICAL REQUIREMENTS

Review the following options to determine for your home:

4-wire receptacle (NEMA type14-30R)

Use the instructions in this section if your home has a 4-wire receptacle (NEMA type 14-30R) and you will be using a UL listed, 120/240 volt minimum, 30 amp, dryer power supply cord.

3-wire receptacle (NEMA type10-30R)

Use the instructions in this section if your home has a 3-wire receptacle (NEMA type 10-30R) and you will be using a UL listed, 120/240 volt minimum, 30 amp, dryer power supply cord.

4-wire direct

If this type is available at your home. you will be connecting to a fused disconnect or circuit breaker box.

4-wire connection : Direct wire

Warning : Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. Failure to do so can result in fire or electrical shock.

Prepare minimum 5 ft (1.52 m) of length in order for dryer to be replaced.

First, peel 5 inches (12.7 cm) of covering material from end. Strip 5 inches of ground wire insulation. After cutting 11/2 inch (3.8 cm) from 3 other wires peel insulation back 1 inch (2.5 cm). Make ends of 3 wires a hook shape.

Then, put the hooked shape end of the wire under the screw of the terminal block (hooked end facing to the right) and pinch the hook together and screw tightly.

3-wire direct

If this type is available at your home. you will be connecting to a fused disconnect or circuit breaker box.

Note

Connect the power supply wire to the terminal block. Colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Otherwise,a short or excessive current flow may result.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect red and black wires to the left and right terminal block screws.

3.Connect ground wire (green) of power cord to external ground screw and move neutral ground wire of appliance and connect it to center screw.

4.Make sure that the strain relief screw is tightened. Be sure that all terminal block nuts are on tight and power cord is in right position.

1 9

REQUIREMENTS

3-wire connection : Direct wire

Warning : Grounding through the neutral conductor is prohibited for (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. Failure to do so can result in fire or electrical shock.

Prepare minimum 5 ft (1.52 m) of length in order for dryer to be replaced.

First, strip 3 1/2 inches (8.9 cm) of outer sheath from end and strip 1 inch of insulation from each conductor.

Then, put the hooked shape end of the wire under the screw of the terminal block (hooked end facing rightward) and pinch the hook together and tighten the screw securely.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect red and black wires to the left and right terminal block screws.

3.Make sure that the strain relief screw is tightened. Be sure that all terminal block nuts are on tight and power cord is in right position.

2 0

Option 1: 4-wire connection with a power supply cord.

lf your local codes or ordinances do not allow the use of a 3-wire connection, or you are installing your dryer in a mobile home, you must use a 4-wire connection.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect red and black wires to the left and right terminal block screws.

3.Connect ground wire (green) of power cord to external ground screw and move neutral ground wire of appliance and connect it to center screw.

4.Make sure that the strain relief screw is tightened. Be sure that all terminal block nuts are on tight and power cord is in right position.

LG TD-V14247E, TD-V10247G, TD-V14247G User Manual

REQUIREMENTS

Option 2: 3-Wire connection with a power supply cord.

or ordinances permit the frame-grounding conductor to the these instructions. If your local

do not allow the connection of conductor to the neutral wire, under Section 1: Optional 3-

.

Section 1

Option 3: Optional 3-wire

connection.

If your local codes or ordinances do not allow the connection of a frame-grounding conductor to the neutral wire, use the instructions under this section.

1.Connect neutral wire (white) of power cord to center terminal block screw.

2.Connect ground wire of appliance and neutral wire of power cord to center terminal block screw.

3.Connect red and black wires to the left and right terminal block screws.

4.Make sure the strain relief screw is tightened. Be sure that all terminal block nuts are on tight and power cord is in right position.

5.Connect a independent ground wire from external ground connector to proper ground.

2 1

Loading...
+ 47 hidden pages