http://www.lgservice.com
LG
LG
Room Air Conditioner
INSTALLATION MANUAL
ESPAÑOL FRANÇAIS ENGLISH
IMPORTANT
•Please read this instruction manual completely before installing the product.
•When the power cord is damaged, replacement should be performed by authorized personnel only.
•Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
•Please retain this installation manual for future reference after reading it thoroughly.
Room Air Conditioner Installation Manual
TABLE OF CONTENTS
Installation |
|
Requirements |
|
Safety Precautions ......................... |
3 |
Introduction ..................................... |
9 |
Symbols Ued in This Manual...... |
9 |
Features ....................................... |
9 |
Installation ..................................... |
10 |
Installation Parts ........................ |
10 |
Installation Tools ........................ |
10 |
Installation Map.......................... |
11 |
Confirm The Refrigerant ........... |
12 |
Select The Best Location ......... |
13 |
Piping Length And Elevation..... |
14 |
How To Mount Installation Plate.. |
15 |
Drill a Hole In The Wall.............. |
15 |
Flaring Work............................... |
16 |
Connecting The Piping.............. |
17 |
Connection Of The Drain Hose... |
22 |
Connection Of Piping -Outdoor... |
22 |
Connection Of The Cable ......... |
23 |
Checking The Drainage ............ |
25 |
Forming The Piping................... |
26 |
Air Purging ................................. |
27 |
Air Purging With Vacuum Pump..27 |
|
Charging..................................... |
29 |
Test Running ................................. |
30 |
Installation guide |
|
at the seaside ................................ |
31 |
Required Parts
Installation plate
Four type "A" screws
Connecting cable
Pipes: Suction line Evaporator line (Refer to page 13)
Insulation materials
Additional drain pipe
(Outer Diameter .........15.5mm(0.61in))
Two type "B" screws
Required Tools
Level gauge
Screwdriver
Electric drill
Hole core drill(ø70mm(2.76in))
Flaring tool set
Specified torque wrenches 4.2kg.m, 6.6kg.m
(different depending on model No.) (Refer to page 17)
Spanner .....................Half union
A glass of water
Screw driver
Hexagonal wrench(4mm(0.16in))
Gas Leak Detector
Vacuum pump
Manifold Gauge
Owner's manual
Thermometer
Remote Control Holder
2 Room Air Conditioner
Safety Precautions
To prevent the injury of the user or other people and property must be followed.
■Incorrect operation due to ignoring instruction will cause harm or classified by the following indications.
This symbol indicates the possibility of
This symbol indicates the possibility of
■ The meanings of the symbols used in this manual are as shown
Be sure not
Be sure to follow the
Safety Precautions
ENGLISH
■ Installation
Do not use damaged power cords, plugs, or a loose socket.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
• There is risk of fire or electric shock.
Do not modify or extend the power cord.
• There is risk of fire or electric shock. |
• There is risk of fire or electric shock. |
Always use the power plug and socket with the ground terminal.
• There is risk of electric shock.
Do not install, remove, or reinstall the unit by yourself (customer).
•There is risk of fire, electric shock, explosion or injury.
Installation Manual 3
Safety Precautions
Be cautious when unpacking and |
For installation, always contact |
installing the product. |
the dealer or an Authorized |
|
Service Center. |
Do not install the product on a defective installation stand.
• Shape edges could cause injury. Be |
• There is risk of fire, electric shock, |
• It may cause injury, accident, or |
especially careful of the sharp edges. |
explosion, or injury. |
damage to the product. |
Be sure the installation area does not deteriorate with age.
Install the indoor unit on the wall where the height from the floors more then 1.5m(4.9ft)
Do not handle the pipe by yourself(customer)
•If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
• There are sharp moving parts that |
• High-Pressure refrigent may cause |
could cause personal injury. |
personal injury. |
1.5m(4.9ft)
■ Operation
Use a dedicated outlet for this |
Grasp the plug to remove the |
appliance. |
cord from the outlet. Do not |
|
touch it with wet hands. |
Do not allow water to run into electric part.
• There is risk of fire or electric shock. |
• There is risk of fire or electric shock. |
• There is risk of fire, failure of the |
|
|
product, and/or electric shock. |
4 Room Air Conditioner
|
|
Safety Precautions |
|
|
|
Do not place a heater or other |
Do not let the air conditioner run |
Do not store of use flammable |
appliances near the power cable. |
for a long time when the |
gas or combustibles near the air |
|
humidity is very high and a door |
conditioner. |
|
or a window is left open. |
|
• There is risk of fire, failure of the product, |
• Moisture may condense and wet or |
• There is risk of fire or product failure. |
and/or electric shock. |
damage furnishings. |
|
Wax |
Thinner |
|
ENGLISH
Do not use the product in a tightly closed space for a long time.
•Oxygen deficiency could occur.
•Some ventilation by opeing window is necessary for the fresh air.
Stop operation and close any window in storm or hurricane. before the hurricane arrives.
•There is risk of property damage, failure of product, or electric shock.
When flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on. Do not use the telephone or turn switches on or off.
• There is risk of explosion or fire.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
•There is risk of physical injury, electric shock, or product.
Unplug the unit if strange sounds odors or smoke comes from it.
•There is risk of fireproduct failure and/or electric shock.
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
• There is risk of electrical shock.
Installation Manual 5
Safety Precautions
Ventilate the product from time to |
Unplug the appliance before |
time when operating it together |
performing cleaning or |
with a stove, etc. |
maintenance. |
• There is risk of fire or electrical shock. |
• There is risk of electric shock. |
When the product is not be used for a long time disconnect the power supply plug or turn off the breaker.
•There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody fall onto the outdoor unit.
• There could result in personal injury and
hands or other objects through the air while the air conditioner is plugged
and moving parts that could cause
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
hose to ensure |
Keep level even when installing |
|
|
|||
|
away |
the product. |
|
|
may cause water |
• To avoid vibration or water leakage. |
product failure. |
leakage. |
90˚
6 Room Air Conditioner
Safety Precautions
Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
•It may cause a problem for your neighbors.
Use two or more people to lift |
Do not install the product where |
and transport the air conditioner |
it will be exposed to sea wind |
|
(salt spray) directly. |
• Avoid personal injury. |
• It may cause corrosion in the product. |
|
Corrosion, particularly on the |
|
condenser and evaporator fins, could |
|
cause product malfunction or |
|
inefficient operation. |
ENGLISH
Do not direct airflow at room occupants.
• This could damage your health.
Use a soft cloth to clean.
Do not use harsh detergents, solvents, etc.
•There is risk of fire, electric shock or damage to the plastic parts of the product.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.
•There is risk of damage or loss of property.
Do not touch the metal parts of the product when removing the air filter. They are very sharp!
• There is risk of personal injury.
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Do not step on or put anything on the product. (outdoor unit)
•There is risk of personal injury and failure of product.
Installation Manual 7
Safety Precautions
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
Do not drink the water drained from the unit.
• A dirty filter reduces the efficiency of the air conditioner and |
• It is not sanitary and could cause serious health issues. |
could cause product malfunction or damage. |
|
Use a firm stool or ladder when cleaning or maintaining the air conditioner.
• Be careful and avoid personal injury.
Replace all the batteries in the remote.
• There is risk of fire or explosion.
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
• They may burn or explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.
•The chemicals in batteries could cause burns or other health hazards.
8 Room Air Conditioner
Introduction
Introduction
SymbolsUsedInThisManual
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
NOTICE This symbol indicates special notes.
Features
ENGLISH
Air Inlet
Air Filter
Air Intake
Vents
Air Outlet
Vents
Base Plate
Front Panel
Signal Receptor
Air Intake Vents
Connecting
Connecting Wires
Wires
Piping |
Piping |
|
Drain Hose
Drain Hose |
|
Air Outlet Vents |
Base Plate |
|
Installation Manual 9
Installation
Installation
Read carefully, and then follow step by step.
InstallationParts
Installation plate |
Type "A" screw and plastic anchor |
Type "B" screw |
Remote Control Holder |
InstallationTools
Figure |
Name |
Figure |
Name |
|
Screw driver |
|
Ohmmeter |
Electric Drill |
Hexagonal wrench |
Measuring Tape, Knife |
Ammeter |
Hole Core Drill |
Gas Leak Detector |
|
Spanner |
Thermometer, |
|
Level |
||
|
Torque wrench |
Flaring Tool Set |
10 Room Air Conditioner