Please read this instruction manual completely before installing the product.

When the power cord is damaged, replacement should be performed by authorized personnel only.

Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

Room Air Conditioner Installation Manual

TABLE OF CONTENTS

Installation

 

Requirements

 

Safety Precautions .........................

3

Introduction .....................................

9

Symbols Ued in This Manual......

9

Features .......................................

9

Installation .....................................

10

Installation Parts ........................

10

Installation Tools ........................

10

Installation Map..........................

11

Confirm The Refrigerant ...........

12

Select The Best Location .........

13

Piping Length And Elevation.....

14

How To Mount Installation Plate..

15

Drill a Hole In The Wall..............

15

Flaring Work...............................

16

Connecting The Piping..............

17

Connection Of The Drain Hose...

22

Connection Of Piping -Outdoor...

22

Connection Of The Cable .........

23

Checking The Drainage ............

25

Forming The Piping...................

26

Air Purging .................................

27

Air Purging With Vacuum Pump..27

Charging.....................................

29

Test Running .................................

30

Installation guide

 

at the seaside ................................

31

Required Parts

Installation plate

Four type "A" screws

Connecting cable

Pipes: Suction line Evaporator line (Refer to page 13)

Insulation materials

Additional drain pipe

(Outer Diameter .........15.5mm(0.61in))

Two type "B" screws

Required Tools

Level gauge

Screwdriver

Electric drill

Hole core drill(ø70mm(2.76in))

Flaring tool set

Specified torque wrenches 4.2kg.m, 6.6kg.m

(different depending on model No.) (Refer to page 17)

Spanner .....................Half union

A glass of water

Screw driver

Hexagonal wrench(4mm(0.16in))

Gas Leak Detector

Vacuum pump

Manifold Gauge

Owner's manual

Thermometer

Remote Control Holder

2 Room Air Conditioner

Lg Lsn093he, Lsn180ce, Lsn180he, Lsn240ce, As-c0914dz0 Installation Guide

Safety Precautions

To prevent the injury of the user or other people and property must be followed.

Incorrect operation due to ignoring instruction will cause harm or classified by the following indications.

This symbol indicates the possibility of

This symbol indicates the possibility of

■ The meanings of the symbols used in this manual are as shown

Be sure not

Be sure to follow the

Safety Precautions

ENGLISH

Installation

Do not use damaged power cords, plugs, or a loose socket.

• There is risk of fire or electric shock.

Install the panel and the cover of control box securely.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.

• There is risk of fire or electric shock.

Do not modify or extend the power cord.

• There is risk of fire or electric shock.

• There is risk of fire or electric shock.

Always use the power plug and socket with the ground terminal.

• There is risk of electric shock.

Do not install, remove, or reinstall the unit by yourself (customer).

There is risk of fire, electric shock, explosion or injury.

Installation Manual 3

Safety Precautions

Be cautious when unpacking and

For installation, always contact

installing the product.

the dealer or an Authorized

 

Service Center.

Do not install the product on a defective installation stand.

• Shape edges could cause injury. Be

• There is risk of fire, electric shock,

• It may cause injury, accident, or

especially careful of the sharp edges.

explosion, or injury.

damage to the product.

Be sure the installation area does not deteriorate with age.

Install the indoor unit on the wall where the height from the floors more then 1.5m(4.9ft)

Do not handle the pipe by yourself(customer)

If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

• There are sharp moving parts that

• High-Pressure refrigent may cause

could cause personal injury.

personal injury.

1.5m(4.9ft)

Operation

Use a dedicated outlet for this

Grasp the plug to remove the

appliance.

cord from the outlet. Do not

 

touch it with wet hands.

Do not allow water to run into electric part.

• There is risk of fire or electric shock.

• There is risk of fire or electric shock.

• There is risk of fire, failure of the

 

 

product, and/or electric shock.

4 Room Air Conditioner

 

 

Safety Precautions

 

 

 

Do not place a heater or other

Do not let the air conditioner run

Do not store of use flammable

appliances near the power cable.

for a long time when the

gas or combustibles near the air

 

humidity is very high and a door

conditioner.

 

or a window is left open.

 

• There is risk of fire, failure of the product,

• Moisture may condense and wet or

• There is risk of fire or product failure.

and/or electric shock.

damage furnishings.

 

Wax

Thinner

 

ENGLISH

Do not use the product in a tightly closed space for a long time.

Oxygen deficiency could occur.

Some ventilation by opeing window is necessary for the fresh air.

Stop operation and close any window in storm or hurricane. before the hurricane arrives.

There is risk of property damage, failure of product, or electric shock.

When flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on. Do not use the telephone or turn switches on or off.

• There is risk of explosion or fire.

Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product.

Unplug the unit if strange sounds odors or smoke comes from it.

There is risk of fireproduct failure and/or electric shock.

When the product is soaked (flooded or submerged), contact an Authorized Service Center.

• There is risk of electrical shock.

Installation Manual 5

Safety Precautions

Ventilate the product from time to

Unplug the appliance before

time when operating it together

performing cleaning or

with a stove, etc.

maintenance.

• There is risk of fire or electrical shock.

• There is risk of electric shock.

When the product is not be used for a long time disconnect the power supply plug or turn off the breaker.

There is risk of product damage or failure, or unintended operation.

Take care to ensure that nobody fall onto the outdoor unit.

• There could result in personal injury and

hands or other objects through the air while the air conditioner is plugged

and moving parts that could cause

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hose to ensure

Keep level even when installing

 

 

away

the product.

 

may cause water

• To avoid vibration or water leakage.

product failure.

leakage.

90˚

6 Room Air Conditioner

Safety Precautions

Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.

It may cause a problem for your neighbors.

Use two or more people to lift

Do not install the product where

and transport the air conditioner

it will be exposed to sea wind

 

(salt spray) directly.

• Avoid personal injury.

• It may cause corrosion in the product.

 

Corrosion, particularly on the

 

condenser and evaporator fins, could

 

cause product malfunction or

 

inefficient operation.

ENGLISH

Do not direct airflow at room occupants.

• This could damage your health.

Use a soft cloth to clean.

Do not use harsh detergents, solvents, etc.

There is risk of fire, electric shock or damage to the plastic parts of the product.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

There is risk of damage or loss of property.

Do not touch the metal parts of the product when removing the air filter. They are very sharp!

• There is risk of personal injury.

Do not block the inlet or outlet of air flow.

• It may cause product failure.

Do not step on or put anything on the product. (outdoor unit)

There is risk of personal injury and failure of product.

Installation Manual 7

Safety Precautions

Always insert the filter securely. Clean the filter every two weeks or more often if necessary.

Do not drink the water drained from the unit.

• A dirty filter reduces the efficiency of the air conditioner and

• It is not sanitary and could cause serious health issues.

could cause product malfunction or damage.

 

Use a firm stool or ladder when cleaning or maintaining the air conditioner.

• Be careful and avoid personal injury.

Replace all the batteries in the remote.

• There is risk of fire or explosion.

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

• They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

8 Room Air Conditioner

Introduction

Introduction

SymbolsUsedInThisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

Features

ENGLISH

Air Inlet

Air Filter

Air Intake

Vents

Air Outlet

Vents

Base Plate

Front Panel

Signal Receptor

Air Intake Vents

Connecting

Connecting Wires

Wires

Piping

Piping

 

Drain Hose

Drain Hose

 

Air Outlet Vents

Base Plate

 

Installation Manual 9

Installation

Installation

Read carefully, and then follow step by step.

InstallationParts

Installation plate

Type "A" screw and plastic anchor

Type "B" screw

Remote Control Holder

InstallationTools

Figure

Name

Figure

Name

 

Screw driver

 

Ohmmeter

Electric Drill

Hexagonal wrench

Measuring Tape, Knife

Ammeter

Hole Core Drill

Gas Leak Detector

Spanner

Thermometer,

Level

 

Torque wrench

Flaring Tool Set

10 Room Air Conditioner

Loading...