Lg Lmu365hv, Lmu186hv, Lmu245hv, Lmu185hv Owner's Manual

0 (0)

Website http://www.lgservice.com

LG

LG

Multi-Type

Air Conditioner

OWNER'S MANUAL

TYPE: Standard

Artcool Mirror

Ceiling Cassette

ESPAÑOL FRANÇAIS ENGLISH

IMPORTANT

Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.

Please retain this owner's manual for future reference after reading it thoroughly.

Multi-Type Air Conditioner Owner’s Manual

TABLE OF CONTENTS

A. Safety Precautions...............................

3

B. Electrical Safety ...................................

6

Temporary Use of an Adapter.......................

6

Symbols used in this Manual ........................

6

C. Product Introduction ...........................

7

Indoor Units...................................................

7

Outdoor Unit..................................................

7

D. Operating Instructions ........................

8

How to insert the Batteries............................

8

Wireless Remote Controller Maintenance.....

8

Operation Indication Lamps ..........................

9

Operating Method .........................................

9

Wireless Remote Controller ........................

10

Wired Remote Controller

 

(Ceiling Cassette Type Optional) ................

11

Operation Mode ..........................................

12

Healthy Dehumidification Operation............

13

Air Circulation Operation.............................

13

Auto Operation............................................

13

Jet Cool Operation ......................................

14

NEO PLASMA Purification Operation

 

(Optional) ....................................................

14

Auto Clean(Optional)...................................

15

Display Luminosity

 

(Artcool Mirror Type Only)...........................

15

Forced operation.........................................

16

Setting the Current Time.............................

17

Timer Setting...............................................

17

To cancel the Timer Setting ........................

17

Up/Down Airflow Direction Control..............

18

Left/Right Airflow Direction Control

 

(Optional) ....................................................

18

Auto Restart Function .................................

18

E. Maintenance and Service ..................

19

Standard/Artcool Mirror Type......................

19

Ceiling Cassette Type.................................

20

Operation Tips!............................................

21

Self-Diagnosis Function ..............................

21

FOR YOUR RECORDS

Write the model and serial numbers here:

Model #

Serial #

You can find them on a label on the side of each unit.

Dealer's Name

Date Purchased

Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.

You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of

Troubleshooting Tips first, you may not need to call for service at all.

PRECAUTION

Contact the authorized service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

The air conditioner is not intended for use by young children or invalids without supervision.

Young children should be supervised to ensure that they do not play with the air conditioner.

When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.

2 Multi Air Conditioner

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage.

■ Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

ENGLISH

Always use a power plug and socket with a ground terminal.

There is a risk of electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself.

There is risk of fire or electric shock.

Use the correctly rated breaker or fuse.

There is risk of fire or electric shock.

Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age.

It may cause product to fall.

In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work.

An charged capacitor can cause electrical shock.

Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse.

There is risk of fire or electric shock .

Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire.

There is risk of fire or electric shock.

Do not modify or extend the power cable. If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced.

There is risk of fire or electric shock.

Do not use a multi consent. Always use this appliance on a dedicated cicuit and breaker.

Otherwise it can cause electric shock or fire.

Install the panel and the cover of control box securely.

There is risk of fire or electric shock due to dust , water etc.

For installation, removal or reinstall , always contact the dealer or an Authorized Service Center.

There is risk of fire, electric shock, explosion, or injury.

Never install the outdoor unit on a

When the product is soaked (flooded or

moving base or a place from where it

submerged) in water , contact an

can fall down.

Authorized Service Center for repair

 

before using it again.

• The falling outdoor unit can cause damage or

• There is risk of fire or eletric shock.

injury or even death of a person.

 

When installing the unit, use the

Be sure to use only those parts which

installation kit provided with the product.

are listed in the svc parts list. Never

 

attempt to modify the equipment.

• Otherwise the unit may fall and cause severe

• The use of inappropriate parts can cause an

injury.

electrical shock, excessive heat generation or fire.

Owner's Manual 3

Safety Precautions

Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.

Improper or loose connections can cause heat generation or fire.

Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags.

Children may play with them and cause injury.

Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely.

Dirty, loose or broken power plug can cause electric shock or fire.

Be sure to check the refrigerant to the

Don't use a power cord, a plug or a loose

used. Please read the label on the product.

socket which is damaged.

Incorrect refrigerant used can prevent the normal operation of the unit.

Do not place a heater or other heating appliances near the power cable.

There is risk of fire and electric shock.

Do not use the product in a tightly closed space for a long time. Perform ventilation regularly.

Oxygen deficiency could occur and hence harm your health.

Otherwise it may cause a fire or electrical shock.

Do not allow water to run into electric parts. Install the unit away from water sources.

There is risk of fire, failure of the product, or electric shock.

Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product failure.

Do not touch , operate, or repair the product with wet hands. Hold the plug by hand when taking out

There is risk of electric shock or fire.

Do not store or use or even allow flammable gas or combustibles near the product.

There is risk of fire.

If strange sounds, smell or smoke comes from product.Immediately turn the breaker off or disconnect the power supply cable.

There is risk of electric shock or fire.

Ventilate the product room from time to

Turn the main power off and unplug the

time when operating it together with a

unit when cleaning or repairing the

stove, or heating element etc.

product.

• Oxygen deficiency can occur and hence harm

• There is risk of electric shock.

your health.

 

Take care to ensure that nobody

Take care to ensure that power cable

especially kids could step on or fall onto

could not be pulled out or damaged

the outdoor unit.

during operation.

• This could result in personal injury and

• There is risk of fire or electric shock.

When the product is not to be used for a long time, disconnect the power supply plug or turn off the breaker.

There is risk of product damage or failure, or unintended operation.

Do not place ANYTHING on the power cable.

There is risk of fire or electric shock.

Do not plug or unplug the power supply plug to turn the unit ON/OFF .

• There is risk of fire or electric shock.

When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.

Do not use the telephone or turn switches on or off. There is risk of explosion or fire.

Two or more people must lift and transport the product.

Avoid personal injury.

Keep level even when installing the product.

To avoid vibration or noise.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion on the product.

Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods.

It may cause a problem for your neighbors and hence dispute.

Install the drain hose to ensure that the condensed water is drained away properly.

A bad connection may cause water leakage.

Always check for gas (refrigerant) leakage after installation or repair of product.

Low refrigerant levels may cause failure of product.

4 Multi Air Conditioner

 

 

Safety Precautions

Do not use the product for special purposes,

Do not block the inlet or outlet of air flow.

Use a soft cloth to clean. Do not use

such as preserving foods, works of art, etc. It

 

harsh detergents, solvents or splashing

is a consumer air conditioner, not a precision

 

water etc .

refrigeration system.

 

 

• There is risk of damage or loss of property.

• It may cause product failure.

• There is risk of fire, electric shock, or damage

 

 

to the plastic parts of the product.

Do not touch the metal parts of the

Do not step on or put anyting on the

Always insert the filter securely after

product when removing the air filter.

product. (outdoor units)

cleaning. Clean the filter every two weeks

 

 

or more often if necessary.

• There is risk of personal injury.

• There is risk of personal injury and failure of

• A dirty filter reduces the efficiency.

 

product.

 

Do not insert hands or other objects

Be cautious when unpacking and

through the air inlet or outlet while the

installing the product.

product is operating.

 

• There are sharp and moving parts that could

• Sharp edges could cause injury.

cause personal injury.

 

Do not tilt the unit when removing or

Do not mix air or gas other than the

uninstalling it.

specified refrigerant used in the system .

• The condensed water inside can spill .

• If air enters the refrigerant system, an

 

excessively high pressure results, causing

 

equipment damage or injury.

If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas.

The refrigernat gas can cause frostbite (cold burn)

If the refrigerant gas leaks during the installation, ventilate the area immediately.

Otherwise it can be harmfull for your health.

Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.

There is risk of fire or product failure.

If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

Do not recharge or disassemble the batteries. Do not dispose off batteries in

afire.

They may burn or explode.

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.

Moisture may condense and wet or damage furniture.

Do not expose your skin or kids or

Do not drink the water drained from the

Use a firm stool or ladder when cleaning,

plants to the cool or hot air draft.

product.

maintaining or repairing the product at

 

 

an height.

• This could harm to your health.

• It is not sanitary and could cause serious

• Be careful and avoid personal injury.

 

health issues.

 

ENGLISH

Owner's Manual 5

Electrical Safety

Electrical Safety

This appliance must be properly grounded.

To minimize the risk of electric shock, you must alway plug into a grounded oulet.

Do not cut or remove the grounding prong from the power plug.

Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.

If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.

TemporaryUseofanAdapter

We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.

To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.

• Never use the appliance with a broken adapter.

SymbolsusedinthisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTE This symbol indicates special notes.

6 Multi Air Conditioner

Product Introduction

Product Introduction

Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type.

IndoorUnits

[Standard Type]

[Artcool Mirror Type]

Air inlet

Plasma filter (Optional)

Air filter

 

 

Signal

 

Louvers

receiver

Air outlet

 

(Vertical blades) Flap

 

 

 

 

(Horizontal blade)

Grille tab

Front grille

ON/OFF button

Air discharge

Front panel

Signal receiver

Air inlet

Air filter

Plasma filter

ON/OFF button

[Ceiling Cassette Type]

Cabinet

Air Discharge

Front Panel

Signal receiver

Air Inlet

ENGLISH

OutdoorUnit

Air intake vents

Control cover

Connecting wire

Connection pipe

Drain hose

Air outlet vents

Base plate

The figure can be changed according to model.

Owner's Manual 7

Operating Instructions

Operating Instructions

HowtoinserttheBatteries

1.Remove the battery cover by pulling it according to the arrow direction.

2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.(Battery Size = AAA)

3. Reattach the cover by sliding it back into position.

NOTE

1.Always use/replace both batteries of same type.

2.If the system is not to be used for a long time, remove the

batteries to save their working life.

3.If the display screen of remote controller starts, fading replace both of the batteries.

WirelessRemoteControllerMaintenance

1. Choose a suitable place where its safe & easy to reach.

2. Fix the holder to wall etc with the supplied screws firmly.

3. Slide the remote controller inside the holder.

NOTE

1.Remote controller should never be exposed to direct sunlight.

2.Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.

3.In case some other appliances also get operated with remote control, change their position or consult your serviceman.

8 Multi Air Conditioner

Operating Instructions

OperationIndicationLamps

[Standard/Artcool Mirror Type]

On/Off

: Lights up during the system operation, error code and auto restart setting.

Sleep mode

: Lights up during sleep mode auto operation.

Plasma

: The function illustrates its dynamic mode by using a multiple lighting system.

Timer

: Lights up during timer operation.

Defrost mode

: Lights up during defrost mode or *hot start operation

Power Display : Indicates the setting temperature and operation mode.

Operation

Cooling, heating,

 

 

Auto operation mode

 

 

Jet

Auto

mode

Dehumidification

Standard

Too hot

Hot

Comfortable

Cold

Too cold

Cool

clean

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shape of

Setting

 

 

 

 

 

 

 

 

display

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit.

*In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency.

[Ceiling Cassette Type]

 

On/Off

: Lights up during the system operation.

 

Filter Sign

: Lights up after 2400 hours from the time of first operating unit.

 

Timer

: Lights up during Timer operation.

 

Defrost Mode

: Lights up during Defrost Mode or Hot Start operation.(Heat pump model only)

Forced

: To operate the unit when the remote control can't be used

 

 

for any reason.

OperatingMethod

1.The signal receiver is inside the unit.

2.Aim the remote controller towards the unit to operate it. There should not be any blockage in between.

 

 

 

Standard Type

 

 

Artcool Mirror Type

Ceiling Cassette Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

Owner's Manual 9

Operating Instructions

WirelessRemoteController

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Operation Mode

Cooling Mode

Auto Operation

Dehumidification mode

Heating Mode

Fan Mode

• Cooling Model(), Heat Pump Model()

PLASMA Button (Optional)

Used to start or stop the plasma-purification function.

JET COOL Button

Speed cooling operates super high fan speed.

OPERATION MODE SELECTION Button

Used to select the operation mode.

FUNCTION SETTING Button

Used to set or clear Auto Clean or Amart Clean.

LCD LUMINOSITY Button (Optional)

Used to adjust LCD luminosity

SMART CLEAN Button (Optional)

Used to start or stop Smart Clean.

CLEAR ALL Button

Used to clear all timer.

ROOM TEMPERATURE SETTING Button

Used to select the room temperature.

ON/OFF Button

Used to turn on/off the unit.

INDOOR FAN SPEED SELECTION Button

Used to select fan speed in four steps low, medium, high and chaos.

UP/DOWN AIRFLOW Button

Used to stop or start louver movement and set the desired up/down airflow direction.

LEFT/RIGHT AIRFLOW Button(Optional)

Used to set the desired left/right(horizontal) airflow direction.

TIMER AND TIME SETTING Button

Used to set the time of starting or stopping and sleeping operation.

ROOM TEMPERATURE CHECKING Button

Used to check the room temperature.

°C/°F SWITCH Button

Used to switch temperature reading from Celsius to Fahrenheit.

RESET Button

Used to reset the remote controller.

10 Multi Air Conditioner

WiredRemoteController(CeilingCassetteTypeOptional)

1

 

2

 

3

9

 

4

16

10

5

11

6

12

7

13

8

14

 

15

OPERATION INDICATION SCREEN

SET TEMPERATURE Button

WIRELESS REMOTE CONTROLLER RECEIVER

Some products don't receive the wireless signals.

VENTILATION Button

OPERATION MODE SELECTION

Button

SUBFUNCTION Button

FUNCTION SETTING Button

EXIT Button

ON/ OFF Button

ROOM TEMPERATURE Button

FAN SPEED Button

AIR FLOW Button

RESERVATION/ TIME SETTING

Button

SETTING/ CANCEL Button

UP, DOWN, LEFT, RIGHT Button

RESET Button

ENGLISH

NOTE

Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source.

The actual product can be different from above contents depending upon model type.

Owner's Manual 11

Operating Instructions

OperationMode

1

Press the ON/OFF BUTTON to turn

the unit on.

The unit will respond with a beep.

2

Open the door of the remote controller and press the

operation mode button. Each time the button is pressed, the

operation mode is shifted in the direction of the arrow.

1

3

4

2

Cooling

Auto

Healthy

Heating

Operation

Dehumidification

(Heat pump model only) Air Circulation

 

For cooling or heating operation set the desired indoor

3 temperature by pressing the ROOM TEMPERATURE SETTING

BUTTONS.

For cooling the temperature can be set within

18°C~30°C(64°F~86°F) and for heating the temperature range is 18°C~30°C(60°F~86°F).

To raise the temperature

To lower the temperature

4

Set the fan speed with the remote controller. You can select the fan speed in four steps-low,

medium, high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON.

Each time the button is pressed, the fan speed mode is shifted.

CHAOS Air

Fan speed is on low. Fan speed is on medium. Fan speed is on high.

Natural wind by the CHAOS logic

For fresher feeling, press the INDOOR FAN SPEED SELECTOR BUTTON selector and set to CHAOS mode.

In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

12 Multi Air Conditioner

Operating Instructions

Helpful information

Fan speed and cooling capacity.

The cooling/heating capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed.

High fan speed is recommended when you wish to cool/heat the room quickly.

High

Speed

High

Speed

HealthyDehumidificationOperation

During Healthy Dehumidification Operation

If you select the dehumidification mode on the OPERATION MODE SELECTION

BUTTON, the product starts to run the dehumidification function. It automatically sets the room temperature and airflow volume to the best condition for dehumidification, based on the sensed current room temperature.

In this case, however, the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either.

During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temperature status, so that the room condition is kept healthy and comfortable even in the very humid season.

AirCirculationOperation

This operation circulates the air without cooling or heating. It can be activated by pressing the OPERATION MODE SELECTION

BUTTON. Once the air circulation is activated you can select the air speed by pressing the INDOOR FAN SPEED SELECTOR BUTTON.

NOTE

CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.

AutoOperation

In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature. If you feel hot or cold press the temperature setting buttons respectively for more cooling or heating effect.

NOTE : You cannot set the actual setting temperature and the indoor fan speed in this operation mode. But you can use the Chaos swing in this operation.

If the system is not operating as desired, switch manually to another mode.

ENGLISH

Owner's Manual 13

Operating Instructions

JetCoolOperation

Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.

You can activate this operation by pressing the JET COOL BUTTON. To change from jet cool mode to high fan speed cooling mode, press the JET COOL BUTTON or INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again.

NOTE

Jet cool function cannot be activated during heating mode.

Art Cool and Art Cool Wide models close the side discharges during jet cool operation, for strong cooling.

NEOPLASMAPurificationOperation(Optional)

Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons.

This plasma kills and destroys the contaminants completely to provide clean and hygienic air.

Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller.

Repressing it will deactivate the operation.

PLASMA

 

NOTE

This feature can be used in any operation mode and any fan speed can be used while plasma filter is functioning.

14 Multi Air Conditioner

Operating Instructions

AutoClean(Optional)

During auto clean function, moistures left in indoor units after cooling operation or healthy dehumidification operation can be removed.

This function operate when the unit is turned off.

1

Press the FUNCTION SETTING button 1 time.

 

 

 

 

 

 

 

Auto Clean symbol will blink.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

2 Press the SET/CLEAR button to reserve or cancel the Auto Clean function.

If the Auto Clean function is reserved, whenever the unit is turned off, the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation. Also the louver is closed.

This dries up any remains of moisture & cleans the unit internally.

DisplayLuminosity(ArtcoolMirrorTypeOnly)

The Display Luminosity can be adjusted by using the remote control.

Open the door of the remote controller, and press the LCD LUMINOSITY button.

Display will be dark. Press the button again to set bright display.

Because Display Luminosity is optional function, some product will not operate.

Owner's Manual 15

Operating Instructions

Forcedoperation

Operation procedures when the remote control can't be used.

The operation will be started if the ON/OFF button is pressed.

If you want to stop operation, re-press the button.

[Artcool Mirror Type]

[Standard Type]

ON/OFF

ON/OFF

button

 

button

[Ceiling Cassette Type]

Forced Operation

Button

 

Room Temp. 24°C(75.2°F)

21°C(69.8°F) Room Temp. < 24°C(75.2°F)

Room Temp. < 21°C(69.8°F)

 

 

 

 

Operating mode

Cooling

Healthy Dehumidification

Heating

 

 

 

 

Indoor FAN Speed

High

High

High

 

 

 

 

Setting Temperature

22°C(72°F)

23°C(74°F)

24°C(76°F)

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound

1 "beep".

If you want to stop the operation, re-press the button.

16 Multi Air Conditioner

Operating Instructions

SettingtheCurrentTime

1. Press the TIMER button for 3 seconds.

3. Press the SET / CLEAR button.

2. Press TIME SETTING buttons until the desired time is set.

NOTE

Check the indicator for A.M. and P.M.

TimerSetting

1. Press the TIMER button to

3. Press the SET / CLEAR button.

turn timer on or off.

 

2. Press TIME SETTING buttons until the desired time is set.

NOTE Select one of the following 3 types of operation.

Timer Sleep

Timer On

Timer Off

TocanceltheTimerSetting

• If you wish to cancel all timer setting, press the CLEAR ALL button.

• If you wish to cancel each timer setting, press the TIMER button to turn timer sleep or on or off as you want.

And then press the SET/CLEAR button aiming the remote controller at the signal receptor.

(The timer lamp on the air conditioner and the display will go off.)

ENGLISH

Owner's Manual 17

Operating Instructions

Up/Down Airflow Direction Control

The up/down airflow (Vertical Airflow) can be adjusted by using the remote controller.

1.Press the ON/OFF button to start the unit.

2.Press UP/DOWN AIRFLOW button and the louvers will swing up and down.

Press the UP/DOWN AIRFLOW button again to set the vertical louver at the desired airflow direction.

NOTICE

If you press the UP/DOWN AIRFLOW button, the horizontal airflow direction is changed automatically based on the Auto Swing algorithm to distribute the air in the room evenly and at the same time to make the human body feel more comfortable, as if enjoying a natural breeze.

Always use the remote controller to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand, could damage the air conditioner.

When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.

Left/Right Airflow Direction Control (Optional)

The left/right(horizontal) airflow can be adjusted by using the remote control.

1.Press the ON/OFF button to start the unit.

2.Press the LEFT/RIGHT AIRFLOW button and the louvers will swing left and right. Press

the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction.

Up/Down and Left/Right Airflow function isn’t shown on display of remote controller.

AutoRestartFunction

This function is useful in the situation of power failure.

When power regains after a failure this feature restore the previous operating condition and the air conditioner will run in the same settings.

NOTE

This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp will blink 4 times.

To enable it, press the button again for 6 seconds. The unit will beep twice and the indicator lamp will blink 4 times.

18 Multi Air Conditioner

Lg Lmu365hv, Lmu186hv, Lmu245hv, Lmu185hv Owner's Manual

Maintenance and Service

Maintenance and Service

Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord.

Standard/ArtcoolMirrorType

Clean the unit with a soft dry cloth. Do not use bleach or abrasives.

Never use any of these

oilne

Water hotter than 40°C(104°F). It may cause deformation and discoloration.

Volatile substances. They may damage the surface of the air

conditioner.

Air Filters

The air filters behind the front panel / grill should be checked and cleaned once in every 2 weeks or more often if necessary. To remove the filters see the self explanatory diagrams for each model type. Clean the filters with a vacuum cleaner or warm soapy water. If dirt is not easily removed, wash with a solution of detergent in luke warm water. Dry well in shade after washing and reinstall the filters back in place.

Plasma Filters

The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary. To remove the filters see the self explanatory diagrams for each model type. Clean the filters with a vacuum cleaner. If it is dirty wash it with water and dry well in shade an install back in place.

Deodorizer Filters

Remove the deodorizer filters behind the air filter

and expose them in direct sunlight for 2 hours.

And then insert these filters into original position. Deodorizer filter

Removal of Filters

Plasma filter

 

Open the front panel as shown.

Then pull the filter tab slightly forward to remove the air filter.

After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward.

[Artcool Mirror Type]

Plasma filter

Front panel

[Standard Type]

Deodorizer

filter

Plasma filter

Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.

ENGLISH

Owner's Manual 19

Maintenance and Service

How to use the front panel [Artcool Mirror Type]

1. Front panel closing

2. Front panel removing

Move the link upward and close the front panel.

Raise the link up to hook hanger and remove

 

front panel forward.

CeilingCassetteType

Grille, Case and Remote Control

Turn the system off before cleanining, To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

NOTE

Supply power must be disconnected before cleaning the indoor unit.

Air Filters

The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary.

Never use any of the followings:

Water hotter than 40°C.

Could cause deformation and/or discoloration.

Volatile substances.

Could damage the surfaces of the air conditioner.

 

SI

 

 

 

NNER

S

 

 

 

COURING

B

 

CL

BA RGER

enzene

 

 

1 Remove the Air filters.

Take hold of the tab and pull slightly forward to remove the filter.

CAUTION: When the air filter is to be removed, do not touch the metal parts of the indoor unit.

It may cause an injury.

2 Clean dirt from the air filter using a vacuum cleaner or washing with water.

If dirt is conspicuous, wash with a neutral detergent in lukewarm water.

If hot water (50°C or more) is used, it may be deformed.

3 After washing with water, dry well in the shade.

Do not expose the air filter to direct sunlight or heat from a fire when drying it.

4 Install the air filter.

20 Multi Air Conditioner