Lg B-mmh09fa-1, B-mmc12fa-1, B-mmc09fa-1, A-mmh36fa-1, A-mmc36fa-1 Service Manual

...
0 (0)

HEAT CONTROLLER, INC.

Wall Mounted

Multi-Split System

Air Conditioning/Heat Pump

Indoor Unit: B-MMC09FA-1

B-MMH09FA-1

B-MMC12FA-1

B-MMH12FA-1

Outdoor Unit : A-MMH18FA-1

A-MMC24FA-1

A-MMH24FA-1

A-MMC36FA-1

A-MMH36FA-1

Before servicing the unit, read the “safety precautions” in this manual.

Only for authorized service personnel.

Multi type Air Conditioner Service Manual

 

TABLE OF CONTENTS

 

Combination table.......................................................................................................................................

3

Safety Precautions......................................................................................................................................

4

Installation guide at the seaside..............................................................................................................

10

Dimensions................................................................................................................................................

11

Indoor Unit..............................................................................................................................................

11

Outdoor Unit ...........................................................................................................................................

12

Product Specifications .............................................................................................................................

15

Indoor Unit..............................................................................................................................................

15

Outdoor Unit ...........................................................................................................................................

16

Installation .................................................................................................................................................

19

Installation Parts.....................................................................................................................................

19

Installation Tools.....................................................................................................................................

19

Select the best location .........................................................................................................................

20

Piping length and elevation ....................................................................................................................

21

Fixing Installation Plate(Standard Type).................................................................................................

22

Drill a hole in the wall ...........................................................................................................................

22

Flaring Work and Connection of Piping..................................................................................................

23

Flaring work............................................................................................................................................

24

Connecting the Piping ............................................................................................................................

24

Connecting the Cable between Indoor Unit and Outdoor Unit .............................................................

31

Connect the cable to the Indoor unit. .....................................................................................................

31

Connect the cable to the Outdoor unit....................................................................................................

32

Connection method of the connecting cable(Example)..........................................................................

33

Connect the cable to the indoor unit.......................................................................................................

34

Checking the Drainage, Forming the Pipings and Long Pipe Setting .................................................

35

Checking the drainage............................................................................................................................

35

Forming the piping..................................................................................................................................

36

Air Purging and Evacuation .....................................................................................................................

37

Checking method ...................................................................................................................................

37

Evacuation..............................................................................................................................................

38

Charging ....................................................................................................................................................

39

Test Running .............................................................................................................................................

40

Operation ...................................................................................................................................................

41

Function of control..................................................................................................................................

41

Function of Indoor Unit ...........................................................................................................................

46

Function of Outdoor Unit ........................................................................................................................

47

Remote Control Operation .....................................................................................................................

48

Disassembly ..............................................................................................................................................

49

Indoor Unit..............................................................................................................................................

49

Schematic Diagram...................................................................................................................................

52

Electronic Control Device .......................................................................................................................

52

Wiring Diagram.......................................................................................................................................

55

Components Locations...........................................................................................................................

57

Troubleshooting Guide.............................................................................................................................

61

Refrigeration Cycle Diagram ..................................................................................................................

61

Self-diagnosis Function ..........................................................................................................................

64

Cycle Troubleshooting Guide..................................................................................................................

65

Electronic Parts Troubleshooting Guide .................................................................................................

66

Error Code..............................................................................................................................................

71

2-way, 3-way Valve ....................................................................................................................................

75

Exploded View ..........................................................................................................................................

79

Indoor Unit .............................................................................................................................................

79

Outdoor Unit ...........................................................................................................................................

81

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 2 -

Only for training and service purposes

LGE Internal Use Only

 

 

 

 

 

 

 

 

Combination table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination table

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18 kBtu( 2 rooms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit-A

 

Unit-B

 

Total

 

 

 

 

 

 

 

 

 

 

 

1 UNIT

9

 

 

-

9

 

 

 

 

 

 

 

 

 

 

 

 

2 UNIT

9

 

 

9

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 kBtu( 2 rooms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit-A

 

Unit-B

 

Total

 

 

 

 

 

 

 

 

 

 

 

1 UNIT

9

 

 

-

9

 

 

 

 

 

 

 

 

 

 

 

12

 

 

-

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

9

18

 

 

 

 

 

 

 

 

 

 

 

 

2 UNIT

9

 

 

12

21

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

12

24

 

 

 

 

 

 

 

 

 

 

36 kBtu (3 rooms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit-A

 

Unit-B

 

Unit-C

 

Total

 

 

 

 

 

 

 

 

 

 

 

1 UNIT

9

 

-

 

-

 

9

 

 

 

 

 

 

 

 

 

 

 

12

 

-

 

-

 

12

 

 

 

 

 

 

 

 

 

9

 

9

 

-

 

18

 

 

 

 

 

 

 

 

 

 

 

 

2 UNIT

9

 

12

 

-

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

12

 

-

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

9

 

9

 

27

 

 

 

 

 

 

 

 

 

 

 

 

3 UNIT

9

 

9

 

12

 

30

 

 

 

 

 

 

 

 

 

 

 

9

 

12

 

12

 

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

12

 

12

 

36

 

 

 

 

 

 

 

 

 

 

 

Notes :

1.Cooling Capacity is based on : indoor temp. 26.7°C(80.1°F)DB, 19.4°C(66.9°F)WB; outdoor temp. 35°C(95°F)DB, 23.9°C(75°F)WB

2.Heating Capacity is based on : indoor temp. 21.1°C(70°F)DB, 15.6°C(60.1°F)WB; outdoor temp. 8.3°C(46.9°F)DB, 6.1°C(43°F)WB

SymbolsUsedinthisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that could cause harm to the air conditioner.

 

NOTICE

This symbol indicates special notes.

 

 

 

 

 

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 3 -

Only for training and service purposes

LGE Internal Use Only

 

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

WARNING This symbol indicates the possibility of death or serious injury.

CAUTION This symbol indicates the possibility of injury or damage to properties only.

■ Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

WARNING

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.

There is risk of fire or electric shock.

For electrical work, contact the

Always ground the product.

dealer, seller, a qualified electrician,

 

 

 

 

or an Authorized Service Center.

 

 

 

 

• Do not disassemble or repair the

• There is risk of fire or electric

product. There is risk of fire or

shock.

electric shock.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install the panel and the cover

Always install a dedicated cir-

of control box securely.

cuit and breaker.

• There is risk of fire or electric

• Improper wiring or installation may

shock.

cause fire or electric shock

Use the correctly rated breaker or fuse.

There is risk of fire or electric shock.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 4 -

Only for training and service purposes

LGE Internal Use Only

 

Safety Precautions

Do not install, remove, or re-

Be cautious when unpacking

install the unit by yourself

and installing the product.

(customer).

 

• There is risk of fire, electric shock,

• Sharp edges could cause injury.

 

Be especially careful of the case

 

edges and the fins on the con-

 

denser and evaporator.

Do not install the product on a

Be sure the installation area

defective installation stand.

does not deteriorate with age.

For installation, always contact the dealer or an Authorized Service Center.

There is risk of fire, electric shock, explosion, or injury.

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.

• It may cause injury, accident, or

• If the base collapses, the air condi-

 

tioner could fall with it, causing

 

property damage, product failure,

 

and personal injury.

Moisture may condense and wet or damage furniture.

Do not allow water to run into electric parts.

It may cause There is risk of fire, failure of the product, or electric shock.

Do not store or use flammable

Do not use the product in a

gas or combustibles near the

tightly closed space for a long

product.

time.

• There is risk of fire or failure of

• Oxygen deficiency could occur.

product.

 

Gasolin

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 5 -

Only for training and service purposes

LGE Internal Use Only

 

Safety Precautions

When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.

Do not use the telephone or turn switches on or off. There is risk of explosion or fire

If strange sounds, or smoke

Stop operation and close the

comes from product. Turn the

window in storm or hurricane.

breaker off.

If possible, remove the prod-

 

uct from the window before

 

the hurricane arrives.

• There is risk of electric shock or

• There is risk of property damage,

fire.

failure of product, or electric shock.

When the product is soaked

Be cautious that water could

(flooded or submerged), contact

not enter the product.

an Authorized Service Center.

 

• There is risk of fire or electric

• There is risk of fire, electric shock,

 

or product damage.

to time when

Turn the main power off when cleaning or

etc.

maintaining the product.

 

• There is risk of electric shock.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 6 -

Only for training and service purposes

LGE Internal Use Only

 

Safety Precautions

When the product is not to be used for a long time, disconnect the power by turning off the breaker.

Take care to ensure that nobody could step on or fall onto the outdoor unit.

• There is risk of product damage or failure, or unintend- • This could result in personal injury and product damage.

CAUTION

Installation

Always check for gas (refrigerant) leakage after installation or repair of product.

• Low refrigerant levels may cause

Do not install the product where the noise or hot air from the outdoor unit could oftend neighbors.

• It may cause a problem for your

neighbors.

 

Keep level even when installing the product.

To avoid vibration or water leakage.

90°

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 7 -

Only for training and service purposes

LGE Internal Use Only

 

Lg B-mmh09fa-1, B-mmc12fa-1, B-mmc09fa-1, A-mmh36fa-1, A-mmc36fa-1 Service Manual

Safety Precautions

Operational

Do not expose the skin directly to cool air for long periods of time.

(Don't sit in the draft.)

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

Do not block the inlet or outlet of air flow.

• There is risk of damage or loss of • It may cause product failure. property.

Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.

There is risk of fire, electric shock, or damage to the plastic parts of

Do not touch the metal parts of

Do not step on or put anyting

the product when removing the

on the product. (outdoor

air filter. They are very sharp!

units)

• There is risk of personal injury.

• There is risk of personal injury and

 

failure of product.

Wax

Thinner

Always insert the filter secure-

Do not insert hands or other

ly. Clean the filter every two

objects through the air inlet or

weeks or more often if neces-

outlet while the product is

sary.

operated.

• A dirty filter reduces the efficiency of

• There are sharp and moving parts

the air conditioner and could cause

that could cause personal injury.

product malfunction or damage.

 

Do not drink the water drained from the product.

It is not sanitary and could cause serious health issues.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 8 -

Only for training and service purposes

LGE Internal Use Only

 

Safety Precautions

Use a firm stool or ladder when cleaning or maintaining the product.

• Be careful and avoid personal injury.

If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.

• There is risk of fire or explosion

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

The chemicals in batteries could cause burns or other health hazards.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 9 -

Only for training and service purposes

LGE Internal Use Only

 

Installation guide at the seaside

Installation guide at the seaside

1.Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.

2.Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient performance.

3.If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it needs additional anticorrosion treatment on the heat exchanger.

Selecting the location(Outdoor Unit)

1)If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided. Install the outdoor unit on the opposite side of the sea wind direction.

Sea wind

Sea wind

2) In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.

Windbreak

Sea wind

It should be strong enough like concrete to prevent the sea wind from the sea.

The height and width should be more than 150% of the outdoor unit.

It should be keep more than 70 cm of space between outdoor unit and the windbreak for easy air flow.

3)Select a well-drained place.

1.If you can’t meet above guide line in the seaside installation, please contact LG Electronics for the additional anticorrosion treatment.

2.Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using water

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 10 -

Only for training and service purposes

LGE Internal Use Only

 

Dimensions

Dimensions

IndoorUnit

Split Type Indoor

H

D

W

Installation plate

 

Model

 

Split Type

 

S4

SE

Dimension

 

 

9 kBtu/h

12 kBtu/h

 

 

W

mm(in)

840(33)

895(35.2)

H

mm(in)

270(10.6)

282(11.1)

D

mm(in)

153(6)

165(6.5)

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 11 -

Only for training and service purposes

LGE Internal Use Only

 

Dimensions

OutdoorUnit

W

 

 

 

 

 

 

 

 

D

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L3

H

L4

L6

 

L5

 

L7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UE

 

 

MODEL

 

 

DIM

 

 

18kBtu/h

 

 

 

 

 

 

 

 

 

 

 

W

mm(in)

870(34.3)

 

 

 

 

 

H

mm(in)

655(25.8)

 

 

 

 

 

D

mm(in)

320(12.6)

 

 

 

 

 

L1

mm(in)

370(14.6)

 

 

 

 

 

L2

mm(in)

25(1.0)

 

 

 

 

 

L3

mm(in)

775(30.5)

 

 

 

 

 

L4

mm(in)

25(1.0)

 

 

 

 

 

L5

mm(in)

546(21.5)

 

 

 

 

 

L6

mm(in)

160(6.3)

 

 

 

 

 

L7

mm(in)

160(6.3)

 

 

 

 

 

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 12 -

Only for training and service purposes

LGE Internal Use Only

 

W

 

 

 

 

 

 

 

 

D

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H L3

L4

L6

 

L5

 

L7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UE 1

 

 

MODEL

 

 

DIM

 

 

24kBtu/h

 

 

 

 

 

 

 

 

 

 

 

W

mm(in)

870(34.3)

 

 

 

 

 

H

mm(in)

808(31.8)

 

 

 

 

 

D

mm(in)

320(12.6)

 

 

 

 

 

L1

mm(in)

370(14.6)

 

 

 

 

 

L2

mm(in)

25(1.0)

 

 

 

 

 

L3

mm(in)

775(30.5)

 

 

 

 

 

L4

mm(in)

25(1.0)

 

 

 

 

 

L5

mm(in)

546(21.5)

 

 

 

 

 

L6

mm(in)

160(6.3)

 

 

 

 

 

L7

mm(in)

160(6.3)

 

 

 

 

 

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 13 -

Only for training and service purposes

LGE Internal Use Only

 

Dimensions

W

L2

D

L1

 

L3

 

H

 

 

 

L4

 

 

L11

 

 

 

L10 L11 L11 L11 L11

L5

 

 

L9

L7

L6

L8

 

Gas side

3-way valve

Liquid side 2-way valve

 

 

 

 

UE2

 

 

 

MODEL

 

 

 

DIM

 

 

36kBtu/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

mm(in)

 

870(34.3)

 

 

 

 

 

 

 

 

 

 

H

mm(in)

 

1038(40.7)

 

 

 

 

 

 

 

 

 

 

D

mm(in)

 

320(12.6)

 

 

 

 

 

 

 

 

 

 

L1

mm(in)

 

360(14.2)

 

 

 

 

 

 

 

 

 

 

L2

mm(in)

 

340(13.4)

 

 

 

 

 

 

 

 

 

 

L3

mm(in)

 

25(1.0)

 

 

 

 

 

 

 

 

 

 

L4

mm(in)

 

1035(40.8)

 

 

 

 

 

 

 

 

 

 

L5

mm(in)

 

25(1.0)

 

 

 

 

 

 

 

 

 

 

L6

mm(in)

 

546(21.5)

 

 

 

 

 

 

 

 

 

 

L7

mm(in)

 

160(6.3)

 

 

 

 

 

 

 

 

 

 

L8

mm(in)

 

160(6.3)

 

 

 

 

 

 

 

 

 

 

L9

mm(in)

 

44(11.7)

 

 

 

 

 

 

 

 

 

 

L10

mm(in)

 

64.5(2.5)

 

 

 

 

 

 

 

 

 

 

L11

mm(in)

 

50(2.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 14 -

Only for training and service purposes

LGE Internal Use Only

 

Product Specifications

Product Specifications

Indoor Unit

Indoor Unit Type

 

 

Wall Mounted

 

 

Model

 

B-MMC09FA-1

B-MMH09FA-1

B-MMC12FA-1

B-MMH12FA-1

 

 

 

 

 

 

Nominal Cooling Capacity

kcal/h(W)

2,267(2,637)

2,267(2,637)

3,023(3,516)

3,023(3,516)

 

 

 

Btu/h

9,000

9,000

12,000

12,000

 

 

 

 

 

 

 

 

Nominal Heating Capacity

 

kcal/h(W)

-

2,267(2,637)

-

3,023(3,516)

 

 

 

 

 

 

 

 

 

 

 

 

Btu/h

-

9,000

-

12,000

 

 

 

 

 

 

 

 

Air Circulation

H/M/L

 

CMM(CFM)

8.2(289)

8.2(289)

9.4(332)

9.4(332)

 

 

 

 

 

 

 

Setting temperature range(cool/heat)

°C

18~30

18~30

18~30

18~30

 

 

 

 

 

 

 

 

Fan motor

Output

 

W

15

15

15

15

 

 

 

 

 

 

 

 

 

Model

 

 

DL-88430LGIF

DL-88430LGIF

DL-88430LGIF

DL-88430LGIF

 

 

 

 

 

 

 

 

 

Input

 

V

DC36

DC36

DC36

DC36

 

 

 

 

 

 

 

 

Running Current

A

0.15

0.15

0.15

0.15

 

 

 

 

 

 

 

 

Fan

Type

 

 

Cross Flow Fan

Cross Flow Fan

Cross Flow Fan

Cross Flow Fan

 

 

 

 

 

 

 

 

No. Used / Diameter

EA/inch(mm)

1/3.74(95)

1/3.74(95)

1/3.74(95)

1/3.74(95)

 

 

 

 

 

 

 

Noise Level (Sound Press,1m) H/M/L

dBA

31 / 29 / 22

31 / 29 / 22

36 / 32 / 29

36 / 32 / 29

 

 

 

 

 

 

 

 

Temperature controller

 

 

Thermistor

Thermistor

Thermistor

Thermistor

 

 

 

 

 

 

 

Coil

Tube Size (OD)

inch(mm)

0.197(5.0)

0.197(5.0)

0.197(5.0)

0.197(5.0)

 

 

 

 

 

 

 

 

Fins per inch

 

20

20

18

18

 

 

 

 

 

 

 

 

No. of Rows & Column

 

2R,15C

2R,15C

2R,15C

2R,15C

 

 

 

 

 

 

 

 

Dehumidification Rate

 

l/h

-

1.1

-

1.2

 

 

 

 

 

 

 

 

Dimensions (W*H*D)

 

inch(mm)

33.0*10.6*6.0(840*270*153)

33.0*10.6*6.0(840*270*153)

35.2*11.1*6.5(895*282*165)

35.2*11.1*6.5(895*282*165)

 

 

 

 

 

 

 

 

Net Weight

 

 

kg(lbs)

7(15.4)

7(15.4)

9.5(20.9)

9.5(20.9)

 

 

 

 

 

 

 

 

Piping Connection

Liquid

 

inch(mm)

1/4 (6.35)

1/4 (6.35)

1/4 (6.35)

1/4 (6.35)

 

 

 

 

 

 

 

 

 

Gas

 

inch(mm)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

 

 

 

 

 

 

 

 

Drain hose (ID Ø)

mm

20

20

20

20

 

 

 

 

 

 

 

 

Packing Dimension (W*H*D)

 

inch(mm)

35.7*13.1*8.8(906*332*223)

35.7*13.1*8.8(906*332*223)

38.3*9.1*14.6(973*231*372)

38.3*9.1*14.6(973*231*372)

 

 

 

 

 

 

 

Stuffing Quantity

With(Without) S/Parts

20/40ft(hi-c)

440/910 (1091)

440/910 (1091)

353/719 (792)

353/719 (792)

 

 

 

 

 

 

 

 

Note : 1. See the page "Combination Table"

2. Due to our policy of innovation some specifications may be changed without notification.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 15 -

Only for training and service purposes

LGE Internal Use Only

 

Product Specifications

OutdoorUnit-Multiplepipingmodels

 

Model

 

A-MMH18FA-1

 

 

 

 

 

Cooling Capacity

 

 

Btu/hr

9,000~18,000

 

 

 

 

 

 

 

 

W

2637~5275

 

 

 

kcal/hr

2267~4536

Heating Capacity

 

 

Btu/hr

9,000~18,000

 

 

 

 

 

 

 

 

W

2637~5275

 

 

 

kcal/hr

2267~4536

Input

Cooling

 

W

1070~1980

 

 

 

 

 

 

Heating

 

W

1040~1960

Running Current (208/230V)

Cooling

 

A

4.9~8.8

 

 

 

 

 

 

Heating

 

A

4.6~8.6

Power Supply

 

 

Ø,V,Hz

1,208/230,60

 

 

 

 

 

Max. Number of Connectable Indoor Units

 

2

 

 

 

 

 

Compressor

Type

 

Rotary

(Constant)

Model

 

GK094K

 

Motor Type

 

 

Hermetic

 

 

 

 

 

 

Quantity

 

Ea

1

 

Motor Input

 

W

955

 

Oil Charge

cc

330±10

 

Oil Type

 

FVC68D

 

 

 

 

 

 

Capacitor

 

µF/Vac

30 / 370

 

O.L.P Type(model name)

 

External Type(MRA98996-12026)

Compressor

Type

 

Rotary

(Constant)

Model

 

GK113K

 

 

 

 

 

 

Motor Type

 

Hermetic

 

Quantity

 

Ea

1

 

Motor Input

 

W

1,120

 

 

 

 

 

 

Oil Charge

 

cc

330±10

 

 

 

 

 

 

Oil Type

 

FVC68D

 

Capacitor

 

µF/Vac

35 / 370

 

O.L.P Type(model name)

 

External Type(MRA12124-12026)

 

 

 

 

 

Refrigerant charge

Charge

 

g(oz)

1400(49)

 

Type

 

R410A

 

Control

 

EEV

Coil

Tube Size (OD)

 

inch(mm)

0.276(7.0)

 

 

 

 

 

 

Fins per inch

 

18

 

No. of Rows & Column/No.

 

2R,28C

Fan motor

Model

 

IC-1640LG GE

 

Output

 

W

90

 

 

 

 

 

 

Capacitor

 

µF/Vac

6/370

Fan

Type

 

Propeller

 

No. Used / Diameter

 

EA/inch(mm)

1 / 460

 

 

 

 

 

 

Discharge

 

Side / Top

Side

 

 

 

 

 

Air Circulation

Outdoor

 

CMM(CFM)

50(1765.7)

Noise Level(H/L) at 230V

Sound Press,1m

 

dB(A) 1

51

Defrosting

 

 

 

Invertion Cycle

 

 

 

 

 

SVC Valve

Liquid

 

inch(mm)

1/4 (6.35) * 2EA

 

Gas

 

 

3/8 (9.52) * 2EA

Dimensions

W*H*D

 

inch(mm)

34.3*25.8*12.6 (870*655*320)

Net Weight

Outdoor

 

kg(lbs)

57(125.7)

 

 

 

 

 

Max. Interunit Piping Length

Total of Each Room

 

m

30

 

For One Room

 

m

15

Max. Installation

Indoor Unit~Outdoor Unit

 

m

7.5

Height Difference

Indoor Unit~Indoor Unit

 

m

7.5

 

 

 

 

 

Packing Dimension

W*H*D

 

inch(mm)

40.2*28.2*17.2 (1020*716*437)

Testing Combinations

 

 

 

S4 9k + S4 9k

Stuffing Quantity

 

 

20/40ft

81/171

Note:

1. Capacities are based on the following conditions:

Cooling:

- Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F) WB

 

- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F) WB

Heating:

- Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB

 

- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB

Piping Length

- Interconnecting Piping Length 7.5m

 

- Level Difference of Zero

2.Wiring cable size must comply with the applicable local and national code.

3.Capacities are Net Capacities.

4.: See the page "Combination Table"

5.The specification may be subject to change without prior notice for purpose of improvement.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 16 -

Only for training and service purposes

LGE Internal Use Only

 

Product Specifications

 

Model

 

A-MMC24FA-1

A-MMH24FA-1

 

 

 

 

 

 

Cooling Capacity

 

 

Btu/hr

9,000~24,000

9,000~24,000

 

 

 

 

 

 

 

 

 

W

2637~7033

2637~7033

 

 

 

kcal/hr

2267~6037

2267~6037

Heating Capacity

 

 

Btu/hr

-

9,000~24,000

 

 

 

 

 

 

 

 

 

W

-

2637~7033

 

 

 

kcal/hr

-

2267~6037

Input

Cooling

 

W

1170~2390

1170~2390

 

 

 

 

 

 

 

Heating

 

W

-

1220~2440

Running Current (208/230V)

Cooling

 

A

7.7~10.1

7.7~10.1

 

 

 

 

 

 

 

Heating

 

A

-

7.4~9.8

Power Supply

 

 

Ø,V,Hz

1,208/230,60

1,208/230,60

Max. Number of Connectable Indoor Units

 

2

2

 

 

 

 

 

 

Compressor

Type

 

Rotary

Rotary

(Constant)

Model

 

GK094K

GK094K

 

Motor Type

 

 

Hermetic

Hermetic

 

Quantity

 

Ea

1

1

 

 

 

 

 

 

 

Motor Input

 

W

955

955

 

Oil Charge

cc

330±10

330±10

 

Oil Type

 

FVC68D

FVC68D

 

 

 

 

 

 

 

Capacitor

 

µF/Vac

30 / 370

30 / 370

 

 

 

 

 

 

 

O.L.P Type(model name)

 

External Type(MRA98996-12026)

External Type(MRA98996-12026)

Compressor

Type

 

Rotary

Rotary

(Constant)

Model

 

GK141K

GK141K

 

 

 

 

 

 

 

Motor Type

 

Hermetic

Hermetic

 

 

 

 

 

 

 

Quantity

 

Ea

1

1

 

Motor Input

 

W

1430

1,430

 

Oil Charge

 

cc

350±10

350±10

 

 

 

 

 

 

 

Oil Type

 

FVE

FVE

 

Capacitor

 

µF/Vac

35 / 370

35 / 370

 

O.L.P Type(model name)

 

External Type(MRA12105-12026)

External Type(MRA12105-12026)

Refrigerant charge

Charge

 

g(oz)

1600

1600

 

 

 

 

 

 

 

Type

 

R410A

R410A

 

Control

 

EEV

EEV

Coil

Tube Size (OD)

 

inch(mm)

0.276(7.0)

0.276(7.0)

 

 

 

 

 

 

 

Fins per inch

 

18

18

 

 

 

 

 

 

 

No. of Rows & Column/No.

 

2R,36C

2R,36C

Fan motor

Model

 

IC-1640LG GE

IC-1640LG GE

 

Output

 

W

90

90

 

 

 

 

 

 

 

Capacitor

 

µF/Vac

6/370

6/370

 

 

 

 

 

 

Fan

Type

 

Propeller

Propeller

 

No. Used / Diameter

 

EA/inch(mm)

1 / 460

1 / 460

 

Discharge

 

Side / Top

Side

Side

 

 

 

 

 

 

Air Circulation

Outdoor

 

CMM(CFM)

53(1872)

53(1872)

Noise Level(H/L) at 230V

Sound Press,1m

 

dB(A) 1

54

54

Defrosting

 

 

 

-

Invertion Cycle

SVC Valve

Liquid

 

inch(mm)

1/4 (6.35) * 2EA

1/4 (6.35) * 2EA

 

 

 

 

 

 

 

Gas

 

 

3/8 (9.52) * 2EA

3/8 (9.52) * 2EA

Dimensions

W*H*D

 

inch(mm)

34.3*31.8*12.6 (870*808*320)

34.3*31.8*12.6 (870*808*320)

Net Weight

Outdoor

 

kg(lbs)

64(141.1)

64(141.1)

 

 

 

 

 

 

Max. Interunit Piping Length

Total of Each Room

 

m

30

30

 

 

 

 

 

 

 

For One Room

 

m

15

15

Max. Installation

Indoor Unit~Outdoor Unit

 

m

7.5

7.5

Height Difference

Indoor Unit~Indoor Unit

 

m

7.5

7.5

 

 

 

 

 

 

Packing Dimension

W*H*D

 

inch(mm)

40.2*34.3*17.2 (1022*870*437)

40.2*34.3*17.2 (1022*870*437)

 

 

 

 

 

 

Testing Combinations

 

 

 

SE 12K +SE 12K

SE 12K +SE 12K

Stuffing Quantity

 

 

20/40ft

54/114

54/114

Note:

1. Capacities are based on the following conditions:

Cooling:

- Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F) WB

 

- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F) WB

Heating:

- Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB

 

- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB

Piping Length

- Interconnecting Piping Length 7.5m

 

- Level Difference of Zero

2.Wiring cable size must comply with the applicable local and national code.

3.Capacities are Net Capacities.

4.: See the page "Combination Table"

5.The specification may be subject to change without prior notice for purpose of improvement.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 17 -

Only for training and service purposes

LGE Internal Use Only

 

Product Specifications

 

Model

 

A-MMC36FA-1

A-MMH36FA-1

 

 

 

 

 

 

Cooling Capacity

 

 

Btu/hr

9,000~36,000

9,000~36,000

 

 

 

 

 

 

 

 

 

W

2637~10,550

2637~10,550

 

 

 

kcal/hr

2267~9071

2267~9071

 

 

 

 

 

 

Heating Capacity

 

 

Btu/hr

-

9,000~36,000

 

 

 

 

 

 

 

 

 

W

-

2637~10,550

 

 

 

kcal/hr

-

2267~9071

Input

Cooling

 

W

1320~3680

1320~3680

 

 

 

 

 

 

 

Heating

 

W

-

1410~3340

Running Current (208/230V)

Cooling

 

A

5.9~16.6

5.9~16.6

 

 

 

 

 

 

 

Heating

 

A

-

6.3~15.0

Power Supply

 

 

Ø,V,Hz

1,208/230,60

1,208/230,60

Max. Number of Connectable Indoor Units

 

3

3

Compressor

Type

 

Rotary

Rotary

(Constant)

Model

 

GK141K

GK141K

 

Motor Type

 

 

2 Pole Induction(PSC)

2 Pole Induction(PSC)

 

Quantity

 

Ea

1

1

 

Motor Input

 

W

1430

1430

 

 

 

 

 

 

 

Oil Charge

cc

350Å}10

350Å}10

 

 

 

 

 

 

 

Oil Type

 

FVC68D

FVC68D

 

Capacitor

 

µF/Vac

35 / 370

35 / 370

 

O.L.P Type(model name)

 

External Type

External Type

 

 

 

 

 

 

Compressor

Type

 

Rotary

Rotary

 

 

 

 

 

 

(Constant)

Model

 

GJ230K

GJ230K

 

Motor Type

 

2 Pole Induction(PSC)

2 Pole Induction(PSC)

 

Quantity

 

Ea

1

1

 

 

 

 

 

 

 

Motor Input

 

W

2370

2370

 

Oil Charge

 

cc

700±10

7000±10

 

Oil Type

 

FVC68D

FVC68D

 

Capacitor

 

µF/Vac

50 / 400

50 / 400

 

 

 

 

 

 

 

O.L.P Type(model name)

 

Internal Type

Internal Type

Refrigerant charge

Charge

 

g(oz)

2400

2400

 

Type

 

R410A

R410A

 

 

 

 

 

 

 

Control

 

EEV

EEV

 

 

 

 

 

 

Coil

Tube Size (OD)

 

inch(mm)

0.276(7.0)

0.276(7.0)

 

Fins per inch

 

18

18

 

No. of Rows & Column/No.

 

2R,48C

2R,48C

 

 

 

 

 

 

Fan motor

Model

 

ARC286B01 * 2

ARC286B01 * 2

 

Output

 

W

102

102

 

Capacitor

 

µF/Vac

2/370

2/370

Fan

Type

 

Propeller

Propeller

 

 

 

 

 

 

 

No. Used / Diameter

 

EA/inch(mm)

2 / 15.7(400)

2 / 15.7(400)

 

Discharge

 

Side / Top

Side

Side

Air Circulation

Outdoor

 

CMM(CFM)

63(2225)

63(2225)

Noise Level(H/L) at 230V

Sound Press,1m

 

dB(A) 1

51

51

 

 

 

 

 

 

SVC Valve

Liquid

 

inch(mm)

1/4 (6..35) * 3EA

1/4 (6..35) * 3EA

 

Gas

 

 

3/8 (9.52) * 3EA

3/8 (9.52) * 3EA

Dimensions

W*H*D

 

inch(mm)

34.3*40.7*12.6 (870*1038*320)

34.3*40.7*12.6 (870*1038*320)

 

 

 

 

 

 

Net Weight

Outdoor

 

kg(lbs)

84(185.2)

84(185.2)

 

 

 

 

 

 

Max. Interunit Piping Length

Total of Each Room

 

m

45

45

 

For One Room

 

m

15

15

Max. Installation

Indoor Unit~Outdoor Unit

 

m

7.5

7.5

 

 

 

 

 

 

Height Difference

Indoor Unit~Indoor Unit

 

m

7.5

7.5

 

 

 

 

 

 

Packing Dimension

W*H*D

 

inch(mm)

41.3*44.9*17.3 (1048*1140*439)

41.3*44.9*17.3 (1048*1140*439)

Stuffing Quantity

 

 

20/40ft

53/111

53/111

Note:

1. Capacities are based on the following conditions:

Cooling:

- Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F) WB

 

- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F) WB

Heating:

- Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB

 

- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB

Piping Length

- Interconnecting Piping Length 7.5m

 

- Level Difference of Zero

2.Wiring cable size must comply with the applicable local and national code.

3.Capacities are Net Capacities.

4.: See the page "Combination Table"

5.The specification may be subject to change without prior notice for purpose of improvement.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 18 -

Only for training and service purposes

LGE Internal Use Only

 

Installation

Installation

Read carefully, and then follow step by step.

InstallationParts

Installation plate

Type "A" screw and plastic anchor

Type "B" screw

Remote Control Holder

InstallationTools

Figure

Name

Figure

Name

 

Screw driver

 

Ohmmeter

Electric Drill

Hexagonal wrench

Measuring Tape, Knife

Ammeter

Hole Core Drill

Gas Leak Detector

Spanner

Thermometer,

Level

 

Torque wrench

Flaring Tool Set

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 19 -

Only for training and service purposes

LGE Internal Use Only

 

Installation

Select the best location

Indoor unit

1.Do not have any heat or steam near the unit.

2.Select a place where there are no obstacles in front of the unit.

3.Make sure that condensation drainage can be conveniently routed away.

4.Do not install near a doorway.

5.Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.

6.Use a Metal Detector or Metal Scanner to locate studs to prevent unnecessary damage to the wall.

More than 10 cm

 

(3.9 inch)

cm

 

More than 2.4m

(8 ft)

More than 10 cm (3.9 inch)

CAUTION: Install the indoor unit on the wall where the height from the floors more than 2.4 m (8 ft).

Outdoor unit

1.If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.

2.Ensure that the spaces indicated by arrows around front, back and side of the unit.

3.Do not place animals and plants in the path of the warm air.

4.Take the air conditioner weight into account and select a place where noise and vibration are minimum.

5.Select a place so that the warm air and sound from the air conditioner do not disturb neighbors.

Rooftop Installations:

If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.

18 / 24 kBtu

more than 30 cm

 

(11.8 inch)

more than 30 cm

 

(11.8 inch)

 

more than 70 cm

(27.6 inch)

more than 60 cm (23.6 inch)

36 kBtu

more than 30 cm

 

 

(11.8 inch)

more than 30 cm

 

(11.8 inch)

 

more than 70 cm (27.6 inch)

more than 60 cm (23.6 inch)

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 20 -

Only for training and service purposes

LGE Internal Use Only

 

Installation

Piping length and elevation

Multi Piping Type

 

Max total length

Max length of

Min length of

Max Elevation

Max elevation

 

between each

Capacity

of all pipes

each pipe

 

each pipe

 

between indoor

 

 

indoor unit and

 

(A+B/A+B+C)

 

(A/B/C)

 

(A/B/C)

 

outdoor unit (h1)

units (h2)

 

 

 

 

 

 

 

 

18 kBtu

30 m (100 ft)

15 m (50 ft)

 

3 m (10 ft)

 

7.5 m (25 ft)

 

7.5 m (25 ft)

24 kBtu

30 m (100 ft)

15 m (50 ft)

 

3 m (10 ft)

 

7.5 m (25 ft)

 

7.5 m (25 ft)

36 kBtu

45 m (150 ft)

15 m (50 ft)

 

3 m (10 ft)

 

7.5 m (25 ft)

 

7.5 m (25 ft)

 

 

 

 

 

Pipe Size

 

 

 

Indoor Capacity

 

Liquid

Standard Length

 

Additional

 

Gas

 

 

Refrigerant

 

 

 

 

 

 

 

 

 

9 kBtu

9.52 mm (3/8")

6.35 mm (1/4")

7.5 m (25 ft)

20 g/m (0.22 oz/ft)

12 kBtu

9.52 mm (3/8")

6.35 mm (1/4")

7.5 m (25 ft)

20 g/m (0.22 oz/ft)

18 / 24 kBtu

A

 

 

 

36 kBtu

A

 

 

 

 

 

 

 

 

 

h2

h2

B

B

 

h2

h1

h1

 

C

h1

h1

 

 

h1

B

CAUTION: Capacity is based on standard length and maximum allowance length is on the basis of reliability.

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 21 -

Only for training and service purposes

LGE Internal Use Only

 

Installation

Fixing Installation Plate(Standard Type)

The wall you select should be strong and solid enough to prevent vibration

1.Mount the installation plate on the wall with

type "A" screws. If mounting the unit on a concrete wall, use anchor bolts.

Mount the installation plate horizontally by aligning the centerline using a level.

2.Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely.

CHASSIS

 

Distance (mm)

 

(Grade)

 

 

 

 

A

B

C

D

 

 

 

 

 

 

S4

50

105

59

105

 

 

 

 

 

SE

65

110

85

110

Installation Plate

Chassis

Hook

Type "A" screw

D

 

Installation plate

B

 

 

 

 

Ø70mm

C

 

A

Ø70mm

 

Left rear piping

 

Right rear piping

 

Drill a hole in the wall

Drill the piping hole with a Ø 70 mm (Ø 2.75 inch) hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side.

 

WALL

Indoor

Outdoor

5-7 mm

(0.2"~0.3")

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 22 -

Only for training and service purposes

LGE Internal Use Only

 

Flaring Work and Connection of Piping

Flaring Work and Connection of Piping

Flaringwork

Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure.

Cut the pipes

1.Use the piping kit accessory or the pipes purchased locally.

2.Measure the distance between the indoor and the outdoor unit.

3.Cut the pipes a little longer than measured distance.

4.Cut the cable 1.5m (5.0ft) longer than the pipe length.

Burrs removal

1.Completely remove all burrs from the cut cross section of pipe/tube.

2.Put the end of the copper tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.

Putting nut on

Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.

(not possible to put them on after flaring work)

Flaring work

Carry out flaring work using flaring tool as shown below.

Firmly hold copper pipe in a Bar in the dimension shown in the table Below.

Copper

 

Slanted

Uneven Rough

pipe

90°

 

 

Pipe

 

 

 

Reamer

Point down

Flare nut

Copper tube

Outside diameter

A

 

 

 

mm

inch

mm

Ø6.35

1/4

0~0.5

Ø9.52

3/8

0~0.5

 

"A"

 

Handle

Bar

Bar

 

 

Yoke

 

 

 

 

 

 

Cone

 

Copper pipe

 

 

 

Clamp handle

Red arrow mark

 

 

 

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 23 -

Only for training and service purposes

LGE Internal Use Only

 

Flaring Work and Connection of Piping

Check

1.Compare the flared work with the figure by.

2.If a flared section is defective, cut it off and do flaring work again.

Smooth all round

Inside is shiny without scratches

= Improper flaring =

Inclined Surface Cracked Uneven

damaged thickness

Even length all round

Connecting the Piping

Indoor

1. Prepare the indoor unit's piping and drain hose for installation through the wall.

2. Remove the plastic tubing retainer(see the illustration by) and pull the tubing and drain hose away from chassis.

3. Replace only the plastic tubing holder 1, not the holder 2 in the original position.

For right rear piping

1.Route the indoor tubing and the drain hose in the direction of rear right.

2.Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

3.Tape the tubing, drain hose, and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the Upper side can cause drain pan to overflow inside the unit.

If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors. *Foamed polyethylene or equivalent is recommended.

Drain hose

Tape

Connecting pipe

Drain hose

Connecting cable

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 24 -

Only for training and service purposes

LGE Internal Use Only

 

Flaring Work and Connection of Piping

4.Indoor unit installation

Hook the indoor unit onto the upper portion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.

Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

Connecting the piping to the indoor unit and drain hose to drain pipe.

1.Align the center of the pipes and sufficiently tighten the flare nut by hand.

2.Tighten the flare nut with a wrench.

Outside diameter

 

Torque

 

 

 

 

 

mm

inch

kg.m

 

lbf.in

Ø6.35

1/4

1.8

 

156.2

Ø9.52

3/8

4.2

 

364.5

3.When extending the drain hose at the indoor unit, install the drain pipe.

Wrap the insulation material around the connecting portion.

1.Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there may be no gap.

2.Wrap the area which accommodates the rear piping housing section with vinyl tape.

3.Bundle the piping and drain hose together by wrapping them with vinyl tape for enough to cover where they fit into the rear piping housing section.

Connecting

cable

Drain hose

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit tubing

Flare nut Pipes

 

 

 

 

 

 

 

 

 

 

Open-end wrench (fixed)

Flare nut

Wrench

Connection pipe

Indoor unit tubing

Drain pipe

Indoor unit drain hose

Adhesive Vinyl tape(narrow)

Plastic bands Insulation material

Connection pipe

Indoor unit pipe

Vinyl tape (wide)

Wrap with vinyl tape

Connecting cable

Pipe

Vinyl tape(narrow)

Wrap with vinyl tape

Pipe

Vinyl tape(wide)

Drain hose

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 25 -

Only for training and service purposes