Page 1

,t_2005 Lennox Industries Inc,
Dallas, Texas, USA
505,058M
(38152A068)
08/05
Supersedes 06/05
AWARNING
13GCSX Series Units
READ ALL INSTRUCTIONS IN THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE
0 us
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other ap-
pliance.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Technical
L Publications
Lithe U.S.A.
,_)2005
GAS-FIRED
-&WARNING
0Qus
LISTED
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
08/05
Illfllllllllllllllllllllllllllllllllll
505,058M
Illlllllllllllllllllllllllllllllllllllllllllll
Page 2

COIL
BLOWERMOTOR
GAS
PRESSURE SWITC
CONTROL
SECTION
FAN
AIR INDUCER
GAS
1 - Keep unit area clear and free of combustible materi-
als, gasoline and other flammable vapors and liquids.
2 - Inspect return air duct to ensure duct is sealed to
the unit and terminates outside the space contain-
ing appliance.
3 - This unit requires air for combustion and ventilation
to ensure both proper and safe operation. Combus-
tion air is brought in through the condenser section.
Do not block or obstruct the condenser coil or con-
denser fan opening.
4 - Examine the unit periodically to ensure that the physi-
cal support of the unit is sound without sagging,
cracks, gaps, etc. There must be no obvious signs of
deterioration of the unit.
,&WARNING
COIL
,&WARNING
,&WARNING
,&WARNING
Page 1
Page 3

WARNING
THERMOSTAT
HEAT/'/i //'/ COOLI
50 60 70 80
10 15 202530
_,_\'\\\\"III1"////"////
[_Z3
AWARNING
A,WARNING
FOR YOUR SAFETY READ BEFORE LIGHTING
BEFORE LIGHTING the unit, smell all around the fur-
nace area for gas. Be sure to smell next to the floor be-
cause some gas is heavier than air and will settle on the
floor.
The gas valve on may be equipped with either a gas
control switch or gas control knob, Use only your hand
to push the lever or turn the gas control knob. Never use
tools. If the the switch will not move or the knob will not
push in or turn by hand, do not try to repair it. Call a quali-
fied service technician. Force or attempted repair may
result in a fire or explosion.
This unit is equipped with an automatic spark ignition sys-
tem. There is no pilot, In case of a safety shutdown, move
thermostat switch to OFF and return the thermostat
switch to HEAT. An electro-mechanical thermostat is
shown in figure 1. On units with electronic temperature
controls, shut main disconnect off and back on to reset
ignition control.
I FAN A_O OIN 1 1 \_
HEAT OFF COOL
Figure 1
To Place Unit into Operation:
1 - Turn off electrical power to unit.
2 - Set thermostat to lowest setting,
3 - Remove heat section access panel,
4-HoneywellVR8205 Gas Valve with ON/OFF
Switch - Set gas valve switch to ON. See figure 2.
Honeywell VR8205 Gas Valve with Knob -Turn knob
on gas valve counterclockwise 41_ to ON, Do not
force. See figure 3,
5 - Replace heat section access panel,
6 - Turn on electrical power to unit,
7 - Set room thermostat to desired temperature, (If ther-
mostat setpoint temperature is above room tempera-
ture after the pre-purge time expires, main burners
will light),
Honeywell VR8205 Series Gas Valve with
ON/OFF Switch
Regulator
Adjustment Gas Control Switch
Cap _
Inlet Pressure Tap Outlet Pressure Tap
1/8" NPT 1/8" NPT
Figure 2
Page 2
Page 4

Honeywell VR8205 Series Gas Valve with
Control Knob
MANIFOLD PRESSURE
ADJUSTMENT SCREW MANIFOLD
(under PRESSURE
barbed OUTLET
fitting)
Fan Operation
The thermostat fan switch allows you to choose whether
you wish the circulating air blower to operate in either the
AUTO or ON mode. When the AUTO mode is selected,
the circulating air blower will cycle on and offwith the cool-
ing or heating demand. When the ON mode is selected,
the circulating air blower will operate continuously,
INLET _
PRESSURE
PORT
GAS VALVE SHOWN IN OFF POSITION
Figure 3
To Shut Down:
1 - Set the thermostat to the lowest setting,
2 - Turn off electric power to unit,
3 - Remove heat section access panel,
4-HoneywellVR8205 Gas Valve with ON/OFF
Switch - Set gas valve lever to OFF.
Honeywell VR8205 Gas Valve with Knob - Turn
gas valve knob clockwise _ll toOFF, Do not force,
5 - Replace heat section access panel,
kWARNING
There are many styles of thermostats, Though their ap-
pearances may be different, there are many similarities,
System Switch
The thermostat system switch allows you to choose
whether you wish the unit to operate in either the HEAT or
COOL mode, When the HEAT mode is selected, the unit
will operate to satisfy a heating demand, When the COOL
mode is selected, the unit will operate to satisfy a cooling
demand, Some thermostats feature an AUTO system
mode, which automatically switches between the HEAT
and COOL modes to ensure comfort,
To maintain efficiency and longevity, your equipment
must be serviced yearly by a qualified service technician.
Failure to provide proof of proper service can void the
warranty.
AWARNING
Filters
Filter(s) must be installed in the return air system. Filters
should be checked monthly and replaced when neces-
sary. Take note of air flow direction marking on filter frame
when reinstalling filters, Replace disposable or clean per-
manent type as necessary, DO NOT replace permanent
type with disposable,
NOTE - Filters must be U.L.C. approved or equivalent for
use in Canada.
Motors
All motors are permanently lubricated and require no
further lubrication. Motors should be cleaned yearly to
prevent the accumulation of dust and dirt on the windings
or motor exterior,
Coil
Dirt and debris should not be allowed to accumulate on
the coil surfaces or other parts in the air conditioning cir-
cuit. Cleaning should be performed as often as neces-
sary, Use a brush, vacuum cleaner attachment, or other
suitable means. If water is used to clean the coil, be sure
the power to unit is shut off prior to cleaning.
NOTE - Care should be used when cleaning the coil so
that the coil fins are not damaged.
Do not permit the hot condenser air discharge to be ob-
structed by overhanging structures or shrubs,
Page 3
Page 5

Burners
=tWARNING
Typical Flame Appearance
Heat Exchanger
Burner J
Inspect the burner flame periodically during heating sea-
son to ensure proper burner operation,
Light the burners and allow unit to operate for a few min-
utes to establish normal burning conditions. Observe the
burner flames, Flames should be predominantly blue in
color and strong in appearance, Verify that all burners
are lit and that the flame does not impinge on the sides of
the heat exchanger. See figure 4,
Distorted flame or yellow tipping of the natural gas
flame (or long yellow tips on LP/propane flame) may be
caused by one or more of the following: lint or dirt inside
the burner or burner ports; lint or dirt at the air inlet be-
tween the burner and manifold pipe; or an obstruction
over the burner orifice,
Use a soft brush or vacuum to clean the affected areas,
Gas Manifold
Flame
(Blue Only)
Figure 4
Vent Outlet
Visually inspect vent outlet periodically to make sure that
the there is no buildup of soot and dirt. If necessary, clean
to maintain adequate opening to discharge flue products.
Call a qualified service technician if the unit is inopera-
tive, Before calling, always check the following to be
sure service is required:
1 - Be sure electrical disconnect switches are ON,
2 - Check room thermostat for proper setting,
3 - Replace any blown fuses or reset circuit breakers,
4 - Gas valve should be ON,
5 - Air filters should not be plugged, limiting air flow,
6 - Make sure all access panels are in place,
Page 4