Fluid handled
Concentration
[%]
Max. temperature
[°C]
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Ferric sulphate (II) 5 80 Boiler feed water to VdTÜV1466 – 140
Iron phosphating solution (alkaline phosphating) approx
. 5
70
Cooling water
4)
(without anti-freeze)
– 60
Acetic acid 10 60 Closed circuit cooling water – 100
Acetic acid 5 60 Open circuit cooling water – 100
E-coating (water), anaphoresis – 35 Cooling water pH value > 7.5 (with anti-
freeze)
6)
– 110
E-coating (water), cataphoresis – 35 Paint-laden water containing residues of wood
paints
– 30
Ethanol – 60 Paint-laden water containing residues of
plastics paints
– 30
Ethylene glycol – 100 Paint-laden water containing residues of metal
paints
– 30
Ethylene glycol base anti-freeze, inhibited, closed
system
50 110
Slightly contaminated water
4)
– 60
Tannic acid 20 80 Tap water – 60
Glycerine 40 80
Clean water
7)
– 60
Potassium hydroxide 5 40
Raw water
4)
– 60
Potassium nitrate, acid-free 5 30
Swimming pool water (fresh water)
4)
– 60
Potassium sulphate, acid-free 3 20 Lake water (fresh water) – 60
Kerosene (jet fuel) – 80 Barrier water – 70
Condensate
5)
– 120 Fresh water – 60
Condensate, not conditioned – 120 Dam water – 60
Conventional paint on solvent basis 10-40 – Partly desalinated water – 120
Copper sulphate 5 80
Drinking water
4)
– 60
Magnesium sulphate 10 80 Permeate (osmosis) – 140
Maleic acid 10 60 Ultrafiltrate = permeate, pure filtrate, solids
content <1 %
– 30
Milk – 60 Deionised water, free of solids – 60
Lactic acid 5 60 Fully desalinated water – 120
Lactic acid 40 60 Hot water (brewery) – 60
Sodium carbonate 6 60 Water treated to VdTÜV1466 – 140
Sodium hydroxide 5 40
Water with anti-freeze, pH value > 7.5
4) 6)
– 110
Sodium nitrate, acid-free 10 60 Water, waste water, slightly contaminated
water, surface water
– 60
Sodium sulphate, acid-free 5 60 Water, fire-fighting water – 60
Sodium hydroxide 15-20 20 Water, surface water – 60
Oils/emulsions – – Water, rainwater, with strainer – 60
Peanut oil – 90 Water, raw water – 60
Corn oil – 100 Water, drinking water – 60
Linseed oil – 60 Tartaric acid 8 40
Rapeseed oil – 100 Citric acid 25 30
Soybean oil – 100 Lye for bottle rinsing – 90
Spare parts
List of spare parts
Description Ident. No.
Pressure sensor
-1..3 bar 0.6 m cable (red)
01146960
Pressure sensor
-1.0.10 bar 0.6 m cable (blue)
01146961
Description Ident. No.
Pressure sensor
-1.0.16 bar 0.6 m cable (light grey)
01146962
Pressure sensor
-1..25 bar 0.6 m cable (green)
01146963
Pressure sensor
-1..40 bar 0.6 m cable (black)
01146965
6)
Anti-freeze on ethylene glycol basis with inhibitors. Content: >20 % to 50 % (e.g. Antifrogen N)
7)
No ultra-pure water! Conductivity at 25 °C: < 800 µS/cm, neutral with regard to chemical corrosion
Monitoring
Intelligent Pressure Sensor
6