Page 3
Monitoring
Intelligent Pressure Sensor
PumpMeter
PumpMeter
Product description
The PumpMeter device is an intelligent pressure sensor for pumps, with local output of measured values and operating data.
The device consists of two pressure sensors and a display unit. It records the load profile of the pump in order to indicate any potential for optimising energy efficiency and availability.
PumpMeter is supplied completely assembled and parameterised for the corresponding pump. It is ready for operation as soon as the M12 plug connector is plugged in.
Main applications
Industry:
Refrigeration/distributionHeat generation/distributionWater conditioningCooling lubricant distributionWater extractionService water supply
Water:
Water extraction/withdrawalWater treatment/conditioningWater distribution/transport
Building Services:
Air-conditioning systems
Heat generation/distributionWater supply systems
Technical data
Technical data of the display unit
Characteristics Value Power supply 24V DC ± 15% Power input 150 mA Analog signal output 4-20 mA, 3-core Digital connection RS485, Modbus RTU
(Slave)
Enclosure
IP 65
1)
Service interface RS232 Bearing temperature -30 °C to 80 °C Operating temperature -10 °C to 60 °C
Technical data of the sensors
Characteristics Value Signal 4-20 mA Gauge pressure 40 bar max. Enclosure
IP 67
1)
Burst pressure 80 bar max. Fluid temperature -30 °C to 140 °C Installation torque 10 Nm Ambient temperature -10 °C to 60 °C
Materials
Overview of materials
Wetted components Material Pressure sensor measuring unit 1.4542 Pressure sensor process connection 1.4301 Adapter for fitting a sensor
2)
1.0037 or 1.4571
Joint ring Centellen®
Product benefits
Transparent pump operation
Local output of the relevant operating data, especially the operating point of the pump.
Identifies energy saving potentials
by recording and analysing the load profile and displaying the energy efficiency icon (EFF), if applicable.
Saves time and money
The sensors are fitted to the pump at the factory, unlike conventional instruments used in systems.
Helps increase pump availability
by recognising and avoiding operation outside of the intended operating range.
Functions
Pressure transmitter function The discharge pressure or differential pressure of the pump are transmitted as a 4-20 mA signal. Connection via the RS485 serial interface with Modbus protocol is also possible.
1)
Provided that the plugs are connected correctly
2)
Depending on the basic material design of the pump
Monitoring
Intelligent Pressure Sensor
PumpMeter
3
Page 4
Operating data display The device alternately displays the suction pressure and discharge pressure as well as the differential pressure or head.
Recording and analysing of the load profile
The operating hours of the pump in the different modes of operation are recorded in a load profile and saved in a non-volatile memory (protected against power failure). The energy efficiency symbol is displayed when a potential for optimisation is recognised.
Qualitative indication of the pump's current operating point The flashing segment indicates the position of the current operating point on the generalised characteristic curve.
Qualitative indication of the pump's current operating point
Operating range Segment display Description Operation at
extremely low flow
3)
First quarter flashing (1)
Pump possibly not
operated in accordance with its intended use
Increased load on
the components
Operation at moderately low flow
3)
Second quarter flashing (2)
Operation with
potential for optimising energy efficiency
Operation near the optimum
Third quarter flashing (3)
Operation within
intended operating range. Optimum energy efficiency
Operation in overload conditions
Fourth quarter flashing (4)
Limit of the
intended operating range
Possibly overload
of pump and/or motor
Design variants
Adapter:
Depending on thread type and size of the pump's pressure gauge connections
Cable length:
600 mm or 1200 mm, depending on the pump size
Measuring ranges of the pressure sensors:
Depending on the inlet pressure and maximum head
Available measuring ranges
Colour code Measuring range
Minimum Maximum red -1 bar 3 bar blue -1 bar 10 bar light grey -1 bar 16 bar green -1 bar 25 bar black -1 bar 40 bar
Electrical connections
1
1 2 3 4
2
3
4
1 2
3
4
Connections at the device
1 IN1 / port for the suction-side pressure sensor 2 IN2 / port for the discharge-side pressure sensor 3 Service interface 4 EXT / external port for energy supply and signal output
Dimensions and weights
Dimensions of the sensor
3)
For some pump characteristics, no differentiation is made between the low-flow operating conditions in the curve's first two quarters (both flashing simultaneously).
Monitoring
Intelligent Pressure Sensor
4
PumpMeter
Page 5
Dimensions of the display unit
Scope of supply
Display unit fittedSensors fitted with adapter
Fluids handled
Overview of fluids handled
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Alum, acid-free 3 80 Diesel oil 80 Alkaline solution, bottle rinsing, max. 2% sodium
hydroxide
40 Diesel oil, fuel oil EL 60
Alcohol Lubricating oil, turbine oil, does not apply to
SF-D oils (hardly flammable)
80
Aluminium sulphate, acid-free 5 60 Heating oil 80 Ammonium bicarbonate 10 40 Water-oil emulsion (95%, 5%), free of solids 80 Ammonium sulphate 20 60 Phosphate sludge …10 60 Anolyte (dialyte) with acetic acid or formic acid,
free of solids
30 Phosphoric acid 5 20
Accelerator (as preparation) Propanol 80 Drilling/grinding emulsion 60 Cleaning agents – Spirits (40% ethanol) 60 Juice (fruit and sugar juice) 60 Service water 60 Nitric acid 15-20 80 Brewery applications Silicate-free, alkaline degreasing or cleaning
solution containing solid particles
0.3-5 80
Beer mash 100 Fuel – Beer wort 100 Trisodium phosphate 4 80 Brewing water 60 Water – Ice water (brewery) 60 Deionised water (fully desalinated) 140 Vapour condensate (brewery) 140 Dealkalised water 120 Butanol 60 Decarbonised water 120 Calcium acetate, acid-free 10 60
Fire-fighting water
4)
60 Calcium nitrate, acid-free 10 60 River water 60 Diethylene glycol 100
Heating water
5)
140
4)
General criteria for results of water analysis: pH value 7; chloride content (Cl) 250 mg/kg. Chlorine (Cl 2) 0.6 mg/kg
5)
Treatment to VdTÜV 1466; additional requirement: O2 0.02 mg/l
Monitoring
Intelligent Pressure Sensor
PumpMeter
5
Page 6
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Fluid handled
Concentration
[%]
Max. temperature
[°C]
Ferric sulphate (II) 5 80 Boiler feed water to VdTÜV1466 140 Iron phosphating solution (alkaline phosphating) approx
. 5
70
Cooling water
4)
(without anti-freeze)
60
Acetic acid 10 60 Closed circuit cooling water 100 Acetic acid 5 60 Open circuit cooling water 100 E-coating (water), anaphoresis 35 Cooling water pH value > 7.5 (with anti-
freeze)
6)
110
E-coating (water), cataphoresis 35 Paint-laden water containing residues of wood
paints
30
Ethanol 60 Paint-laden water containing residues of
plastics paints
30
Ethylene glycol 100 Paint-laden water containing residues of metal
paints
30
Ethylene glycol base anti-freeze, inhibited, closed system
50 110
Slightly contaminated water
4)
60
Tannic acid 20 80 Tap water 60 Glycerine 40 80
Clean water
7)
60 Potassium hydroxide 5 40
Raw water
4)
60 Potassium nitrate, acid-free 5 30
Swimming pool water (fresh water)
4)
60 Potassium sulphate, acid-free 3 20 Lake water (fresh water) 60 Kerosene (jet fuel) 80 Barrier water 70 Condensate
5)
120 Fresh water 60 Condensate, not conditioned 120 Dam water 60 Conventional paint on solvent basis 10-40 Partly desalinated water 120 Copper sulphate 5 80
Drinking water
4)
60 Magnesium sulphate 10 80 Permeate (osmosis) 140 Maleic acid 10 60 Ultrafiltrate = permeate, pure filtrate, solids
content <1 %
30
Milk 60 Deionised water, free of solids 60 Lactic acid 5 60 Fully desalinated water 120 Lactic acid 40 60 Hot water (brewery) 60 Sodium carbonate 6 60 Water treated to VdTÜV1466 140 Sodium hydroxide 5 40
Water with anti-freeze, pH value > 7.5
4) 6)
110 Sodium nitrate, acid-free 10 60 Water, waste water, slightly contaminated
water, surface water
60
Sodium sulphate, acid-free 5 60 Water, fire-fighting water 60 Sodium hydroxide 15-20 20 Water, surface water 60 Oils/emulsions Water, rainwater, with strainer 60 Peanut oil 90 Water, raw water 60 Corn oil 100 Water, drinking water 60 Linseed oil 60 Tartaric acid 8 40 Rapeseed oil 100 Citric acid 25 30 Soybean oil 100 Lye for bottle rinsing 90
Spare parts
List of spare parts
Description Ident. No. Pressure sensor
-1..3 bar 0.6 m cable (red)
01146960
Pressure sensor
-1.0.10 bar 0.6 m cable (blue)
01146961
Description Ident. No. Pressure sensor
-1.0.16 bar 0.6 m cable (light grey)
01146962
Pressure sensor
-1..25 bar 0.6 m cable (green)
01146963
Pressure sensor
-1..40 bar 0.6 m cable (black)
01146965
6)
Anti-freeze on ethylene glycol basis with inhibitors. Content: >20 % to 50 % (e.g. Antifrogen N)
7)
No ultra-pure water! Conductivity at 25 °C: < 800 µS/cm, neutral with regard to chemical corrosion
Monitoring
Intelligent Pressure Sensor
6
PumpMeter
Page 7
Description Ident. No. Pressure sensor
-1..3 bar 1.2 m cable (red)
01146895
Pressure sensor
-1..10 bar 1.2 m cable (blue)
01146896
Pressure sensor
-1..16 bar 1.2 m cable (light grey)
01146957
Pressure sensor
-1..25 bar 1.2 m cable (green)
01146958
Pressure sensor
-1..40 bar 1.2 m cable (black)
01146959
Joint ring A 8 X 11.5 01015232 Display unit 01146894 Adapter R 1/4 - M8 01146970 Adapter G 1/4 - M8 01146971 Adapter NPT 1/4 - M8 01146972 Adapter R 3/8 - M8 01146973 Adapter G 3/8 - M8 01146974 Adapter NPT 3/8 - M8 01146975 Adapter R 1/2 - M8 01146976 Adapter G 1/2 - M8 01146977 Adapter NPT 1/2 - M8 01146978 Adapter R 1/4 - M8 01186472 Adapter G 1/4 - M8 01186474 Adapter R 3/8 - M8 01191765 Adapter R 1/2 - M8 01191766 Adapter G 3/8 - M8 01191857 Adapter G 1/2 - M8 01191858
Accessories
Overview of accessories
Description Ident. No. Extension cord
Length 5 mFor extending the sensor cables
01146980
Extension cord
Length 10 mFor extending the sensor cables
01146981
Connection cable
Length 1 m5-pole cable with M12 plug for power supply
and signal output
01146982
Connection cable
Length 5 m5-pole cable with M12 plug for power supply
and signal output
01146983
Connection cable
Length 10 m5-pole cable with M12 plug for power supply
and signal output
01146984
Power supply unit for the PumpMeter
24 V / 750 mA (for maximum 5 PumpMeter
devices)
01147695
Monitoring
Intelligent Pressure Sensor
PumpMeter
7
Page 8
KSB Aktiengesellschaft
67225 Frankenthal • Johann-Klein-Str. 9 • 67227 Frankenthal (Germany) Tel. +49 6233 86-0 • Fax +49 6233 86-3401 www.ksb.com
4072.5/2-10 10.11.2010