KROHNE BM102 User Manual

4 (1)
KROHNE BM102 User Manual

© KROHNE 09/2003

7.02239.22.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GR

Supplementary Installation

and Operating Instructions

BM 102

MICROFLEX

KEMA 00 ATEX 1101X

2-WIRE

Variable area flowmeters

Vortex flowmeters

Flow controllers

Electromagnetic flowmeters

Ultrasonic flowmeters

Mass flowmeters

Level measuring instruments

Communications technology

Engineering systems & solutions

Switches, counters, displays and recorders

Heat metering

Pressure and temperature

Contents

 

Nameplate ......................................................................................................................................

3

Range of application .....................................................................................................................

3

Product liability and warranty ......................................................................................................

3

General safety information ...........................................................................................................

4

Standards / Approvals ..................................................................................................................

4

1

Main safety-relevant characteristics .............................................................................

5

1.1

Approved categories .........................................................................................................

5

1.1.1

1 G ....................................................................................................................................

5

1.1.2

1/2 G and 1/2 D.................................................................................................................

5

1.1.3

2 G and 2 D.......................................................................................................................

5

1.2

Maximum safety-relevant values.......................................................................................

5

1.3

Allowable operating pressure............................................................................................

6

1.4

Allowable temperatures.....................................................................................................

7

1.4.1

Process temperature.........................................................................................................

7

1.4.2

Ambient temperature for the electronic equipment............................................................

7

1.4.3

Surface temperature .........................................................................................................

8

2

Installation .......................................................................................................................

9

2.1

Probes...............................................................................................................................

9

2.2

Electrical connection .........................................................................................................

9

3

(Initial) Start-up..............................................................................................................

10

4

Operation .......................................................................................................................

10

5

Service / Maintenance...................................................................................................

11

5.1

Signal converter ..............................................................................................................

11

5.2

Probes.............................................................................................................................

11

5.3

Replacement of complete device ....................................................................................

11

5.4

Maintenance....................................................................................................................

11

Attachment 1 Statement of Conformity to ISO/IEC Guide 22 .............................................

12

Attachment 2 EC Type Test Certificate KEMA 00ATEX1101 X ...........................................

13

If you need to return a device for testing or repair to KROHNE..............................................

15

2

Supplementary Installation and Operating Instructions BM 102 ATEX

Nameplate

The BM 102 level gauge is identified by the following nameplate.

KROHNE S.A. Romans

France

MICROFLEX BM102

0344

II

 

 

KEMA No. 00ATEX1101 X

EEx ia

 

T6 T4

 

TYPE

MANUFACT

N° comm.

COMM.-No.

N° Rep.

TAG No.

N° Fab.

SERIAL No.

Alimentation POWER SUPPLY

Pas de polarité à respecter pour les bornes 1 et 2

NO POLARITY TO BE RESPECTED FOR POWER TERMINALS 1 AND 2

U i <=

30V

C i =

 

nF

I i <=

150mA

 

 

 

 

 

 

P i <=

1W

L i =

 

mH

 

 

 

 

 

Pression Maxi

MAX W. PRESSURE

Degré de protecion

PROTECTION CLASS

Const. électr.

ELECTR. CONST

Temp. Ambiante

AMBIANT TEMP.

Temp. maxi á la bride

MAXI FLANGE TEMP.

Types of protection used in the device; approved Gas Group and Temperature Classes

EEx ia IIC T6…T3 or EEx ia IIB T6…T3

Approved Category:

Ex II 1/2 D T 100°C or Ex II 1 G

Full type code

Date of manufacture

Not relevant to safety

Rated voltage for the device

Maximum device safety values

Maximum pressure of device flange but ≤ 40 bar

Device protection class

Electrical primary constant

Maximum ambient and flange temperatures

Range of application

The BM 102 MICROFLEX level gauge is designed solely for measuring the distance, level and volume of liquids, solids and particulate materials. The device can be operated on storage and process tanks and also on still pipes and reference vessels.

Product liability and warranty

Responsibility for suitability and intended use of these level gauges rests solely with the user.

Improper installation and operation of our devices may lead to loss of warranty.

In addition, the “General conditions of sale“, forming the basis of the purchasing contract, are applicable.

Supplementary Installation and Operating Instructions BM 102 ATEX

3

General safety information

These Supplementary Instructions may only be used in conjunction with the standard Installation and Operating Instructions for the BM 102 level gauge. If you do not have these standard Instructions, please contact your nearest KROHNE office.

Special regulations are applicable to the use of equipment in hazardous locations, and these are described in these Supplementary Instructions (supplied only with “Ex” devices).

The information given in these Instructions contains only the data relevant to explosion protection. The technical details given in the standard Installation and Operating Instructions apply unchanged unless excluded or superseded by these Supplementary Instructions.

Standards / Approvals

In compliance with European Directive 94/9 EC (ATEX 100a), the level gauges described in these Supplementary Instructions are, in conformity with European Standards EN 50014, EN 50020 and EN 50284, certified for use in hazardous locations by the KEMA certification body under KEMA 00 ATEX 1101 X.

It is absolutely necessary that the details contained in this approval certificate, together with its boundary conditions, are observed.

The level gauges of the BM 102 series are suitable for use in explosive atmospheres of all flammable substances of Gas Groups IIA, IIB und IIC (with the exception of the cases named in these Supplementary Instructions) and for applications requiring Category 1G, 1/2G, 1/2D, 2G or 2D equipment.

Assembly, installation, start-up and maintenance may only be carried out by "personnel trained in explosion protection"!

4

Supplementary Installation and Operating Instructions BM 102 ATEX

1 Main safety-relevant characteristics

1.1Approved categories

Plastic-coated probes may not be used in connection with Gas Group IIC substances.

1.1.1 1 G

The BM 102 level gauges are installed in areas requiring Category 1 G equipment. The devices are suitable for use in explosive atmospheres of all flammable substances of Gas Groups IIA, IIB and IIC.

1.1.2 1/2 G and 1/2 D

The signal converter is installed in hazardous locations requiring Category 2 G or 2 D equipment. The probe is installed in hazardous locations requiring Category 1 G or 1 D equipment. The devices are suitable for use in explosive atmospheres of all flammable substances of Gas Groups IIA, IIB and IIC.

Devices with plastic-coated probes may not be used for applications requiring Category 1/2 D equipment, unless effective measures have been taken to avoid electrostatic discharge.

1.1.3 2 G and 2 D

BM 102 devices are installed in locations requiring Category 2 G or 2 D equipment. The devices are suitable for use in explosive atmospheres of all flammable substances of Gas Groups IIA, IIB and IIC.

Devices with plastic-coated probes may not be used for applications requiring Category 2 D equipment, unless effective measures have been taken to avoid electrostatic discharge.

1.2Maximum safety-relevant values

The input terminals of the BM 102 level gauges are not safety-separated from ground. For that reason, only certified electrically isolated intrinsically safe equipment of ignition protection category EEx ia IIC may be connected. This requirement applies independent of the required Category and also if the device is not operated in the hazardous location.

Supplementary Installation and Operating Instructions BM 102 ATEX

5

Loading...