Kohler K-377, K-16111, K-16109, K-378 User Manual

0 (0)

Installation Guide

Kitchen Sink Faucet

K-377, K-378

 

K-16109, K-16111

M product numbers are for Mexico (i.e. K-12345M)

Los números de productos seguidos de

M corresponden a México (Ej.

K-12345M)

Français, page Français-1

Español, página Español-1

1004636-2-D

Tools and Materials

Plus:

• Water supply tubes or hoses

Adjustable

Plumbers

Tube Cutter

Wrench

Putty

 

Thank You For Choosing Kohler Company

We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don’t hesitate to contact us. Our phone numbers and website are listed on the back cover. Thanks again for choosing Kohler Company.

Before You Begin

Observe all local plumbing and building codes.

Shut off the water supplies.

Before installation, unpack the new faucet and inspect it for damage. Return the faucet to the carton until you are ready to install it.

Carefully inspect waste and supply tubing for any sign of damage and replace if necessary.

For new installations, assemble the faucet to the sink before installing the sink.

Kohler Co. reserves the right to make revisions in the design of faucets without notice, as specified in the Price Book.

1004636-2-D

2

Kohler Co.

Handspray

Spout

Spray Holder

Apply plumbers putty.

 

Mounting Hole

Sink

Spray Holder Nut

Spout

 

Washer

Base

Shank

 

Shank Nut

 

Handspray Hose

Shank Tee

1. Install the Spout and Handspray

IMPORTANT! The maximum sink or counter thickness is 1(2.5 cm) for this installation.

Apply a bead of plumbers putty or other sealant to the underside of the spout base according to the manufacturer’s instructions.

Thread the nut and washer to the bottom of the shank until the nut touches the top of the shank tee.

Insert the shank from the bottom of the sink.

Thread the shank into the bottom of the spout between 16 and 19 turns so it is hand tight.

Loosen the shank 1/8 of a turn.

IMPORTANT! Do not loosen the shank more than 1/2 turn. The spout may not seal, resulting in a leak.

Tighten the nut and washer to secure the shank to the sink.

Slide the spray holder through the mounting hole from above.

Securely hand tighten the nut to the spray holder from under the sink.

Insert the handspray hose through the spray holder.

Attach the handspray hose to the shank tee.

Wrench tighten the nut.

Kohler Co.

3

1004636-2-D

Escutcheon

 

Apply

 

plumbers

 

putty.

 

Valve Body

Shank

 

Tee

Washer

Hose

 

Nut

2. Install the Valve Body

Apply a bead of plumbers putty or other sealant to the underside of the escutcheons according to the manufacturer’s instructions.

Thread the hoses to the valve body outlets and wrench tighten. Do not overtighten.

Insert the valve bodies into the mounting holes from the top of the sink. Make sure the hot valve body is installed in the left-hand hole and the cold valve body is installed in the right-hand hole.

Install a washer and then a nut to the bottom of the valve bodies.

Align the valve bodies so the copper tubing faces the outside.

Wrench tighten the nuts.

Remove any excess plumbers putty.

Connect and wrench tighten the hoses to the shank tee. Do not overtighten.

1004636-2-D

4

Kohler Co.

Kohler K-377, K-16111, K-16109, K-378 User Manual

Compression

Ferrule

Nut

Valve Fitting

Cone Union

Supply Tube

Nut

Cold

Supply

Hot

Supply

3. Install the Supplies

NOTE: If the sink is not installed, install it at this time. Be sure to follow all instructions packed with the sink.

For ground joint connections:

Determine the correct length needed for the supply tubes (not included).

Cut the supply tubes using a tube cutter.

Remove any burrs or sharp edges.

Slip a nut and ferrule onto each supply tube.

Securely tighten all nuts.

Carefully insert a supply tube into each supply water outlet.

Align each ferrule with the supply water outlet.

If the connection is a union connection, align and center the cone on each valve fittings and hand tighten the nut.

If it is a compression connection, align and center a ferrule on each valve fitting and hand tighten the nuts.

Wrench tighten all nuts. Do not overtighten.

For hose connections (not shown):

Attach one end of a hose (not supplied) to the hot valve and one end to the hot supply.

Kohler Co.

5

1004636-2-D

Install the Supplies (cont.)

Attach one end of a hose (not supplied) to the cold valve and one end to the cold supply.

Carefully tighten all connections.

1004636-2-D

6

Kohler Co.

Washer

Aerator

Body

Aerator Insert

4. Installation Checkout

Ensure that both faucet handles are turned off. Hot is clockwise close and cold is counterclockwise close.

Turn on the hot and cold water supplies.

Check for leaks.

Remove the aerator body, aerator insert, and washer from the spout by turning it counterclockwise.

Turn on the hot and cold faucet handles.

Run the water for about one minute to remove any debris. Turn off the hot and cold faucet handles.

Place the aerator insert and then the washer into the aerator body. Reinstall the aerator by turning it clockwise until hand tight. Check for leaks.

Kohler Co.

7

1004636-2-D

Guide d’installation

Robinet d’évier de cuisine

Outils et matériels

Plus:

• Tubes ou tuyaux d'alimentation d'eau

Clé à

Mastic de

Coupe-tubes

molette

plombier

 

Merci d’avoir choisi la compagnie Kohler

Nous apprécions votre engagement envers la qualité Kohler. Veuillez prendre s’il vous plaît quelques minutes pour lire ce manuel avant de commencer l’installation. Ne pas hésiter à nous contacter en cas de problème d’installation ou de performance. Nos numéros de téléphone et notre adresse du site internet sont au verso. Merci encore d’avoir choisi la compagnie Kohler.

Avant de commencer

Respecter tous les codes de plomberie et de bâtiment locaux.

Couper les alimentations d’eau.

Avant l’installation, déballer le nouveau robinet et l’examiner pour en déceler tout dommage. Remettre le robinet dans son emballage de protection jusqu’à être prêt à l’installation.

Vérifier avec soin si l’évacuation ou les tubes d’alimentation pour déceler tout signe d’endommagement et remplacer si nécessaire.

Pour de nouvelles installations, installer le robinet sur l’évier avant d’installer ce dernier.

Kohler Co.

Français-1

1004636-2-D

Loading...
+ 16 hidden pages