Kohler k-10950, k-10951 User Manual

0 (0)

Maintenance Guide

Electronic Faucet

K-10950, K-10951

M product numbers are for Mexico (i.e. K-12345M) Los números de productos seguidos de

M corresponden a México (e.j. K-12345M)

Français, page “Français-1” Español, pagina “Español-1”

1025498-5-H

Thank You For Choosing Kohler Company

Thank you for choosing Kohler Company. Your Kohler Company product reflects the true passion for design, craftsmanship, artistry, and innovation Kohler Company stands for. We are confident its dependability and beauty will surpass your highest expectations, satisfying you for years to come.

All information in this guide is based upon the latest product information available at the time of publication. At Kohler Company, we strive to fulfill our mission of improving the level of gracious living for each person who is touched by our products and services. We reserve the right to make changes in product characteristics, packaging, or availability at any time without notice.

Please take a few minutes to review this guide. Pay special attention to the care and cleaning instructions.

Your Kohler Lavatory Faucet

Your new electronic lavatory faucet blends elegant styling and beauty with exceptional performance and reliability. Each faucet is precision engineered and constructed of premium quality materials to provide trouble-free operation even under the hardest water conditions.

Your electronic faucet includes a vandal resistant aerator and an integral vandal resistant mixing handle or plug button. The technology employed for the activation mechanism allows flawless activation of your electronic faucet. The faucet is rated at 6 V DC 1 W and is powered by a 6 V DC battery or an optional AC power supply.

The electronic faucet also includes a vandalism resistant mode to protect the unit from abuse or items left in front of the sensor. If an item is placed in range of the sensor and remains there in excess of 120 seconds, the faucet will not function. The faucet will resume functioning when the item has been removed for a minimum of 3 seconds.

Care and Cleaning

For best results, keep the following in mind when caring for your KOHLER product:

Use a mild detergent such as liquid dishwashing soap and warm water for cleaning. Do not use abrasive cleaners that may scratch or dull the surface.

Carefully read the cleaner product label to ensure the cleaner is safe for use on the material.

1025498-5-H

2

Kohler Co.

Care and Cleaning (cont.)

Always test your cleaning solution on an inconspicuous area before applying to the entire surface.

Do not allow cleaners to sit or soak on the surface.

Wipe surfaces clean and rinse completely with water immediately after cleaner application. Rinse and dry any overspray that lands on nearby surfaces.

Use a soft, dampened sponge or cloth. Never use an abrasive material such as a brush or scouring pad to clean surfaces.

For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care & Cleaning information, call 1-800-456-4537.

Kohler Co.

3

1025498-5-H

Kohler k-10950, k-10951 User Manual

Cleaning

 

Tab Edge

Strap

 

Limit

 

 

 

 

Stop

 

 

Handle

Handle

 

Right Tab

 

Stop

 

 

Screw

Limit

Housing Setscrew

Stop

 

Vandal-Resistant

Plug Button

Adjust the Water Temperature

CAUTION: Risk of personal injury. Scalding may result if the limit stop is not reinstalled properly.

NOTE: The water temperature does not need to be adjusted if the water temperature is below 105°F (41°C).

NOTE: Use a thermometer rated for 120°F (49°C) or greater.

NOTE: When using a tempered water supply, install the vandal-resistant plug button.

For Handle Installations

Turn on the water and adjust to the full hot position by turning the handle toward the back of the faucet until it stops.

Determine the temperature using a thermometer. If the temperature exceeds 105°F (41°C), complete the following steps.

Turn the handle until vertical.

Attach the cleaning strap over the sensor.

Remove the handle screw using the supplied 2.5 mm hex wrench.

Remove the handle and the limit stop.

Remove the limit stop from the handle splines.

1025498-5-H

4

Kohler Co.

Adjust the Water Temperature (cont.)

Rotate and reposition the limit stop on the handle splines. Rotating the limit stop clockwise toward the back of the faucet will decrease the maximum temperature limit. Each spline represents approximately 10°F (5°C) change in temperature.

Reinstall the handle vertically with the limit stop in place. Do not secure the handle with the screw at this time.

Turn the handle to full hot and check the water temperature.

Repeat the above procedures until the desired temperature is reached.

Secure the handle assembly with the screw.

Remove the cleaning strap and turn on the water.

For Vandal-Resistant Installations

NOTE: If you install the vandal-resistant plug button, save the limit stop and handle to adjust the water temperature at a later date.

Using the handle, adjust the water to the desired temperature.

Remove the handle screw using the supplied 2.5 mm hex wrench.

Position the vandal-resistant plug button and firmly press into place.

Kohler Co.

5

1025498-5-H

 

Handle

 

Screw

 

Limit

 

Stop

Handle

Housing

 

Setscrew

Disassemble the Faucet

Perform this step when prompted by text in the following sections.

Turn off the water supply to the faucet.

If applicable, disconnect the AC power supply.

Remove the housing setscrew from the back of the faucet housing using the supplied 2.5 mm hex wrench.

If applicable, remove the handle. Use the provided 2.5 mm hex wrench to remove the handle screw.

1025498-5-H

6

Kohler Co.

Sensor

 

 

Connector

Battery

Position 2

Connector

 

Connector

Position 1

Valve

Battery Clip

 

Service the Battery

CAUTION: Risk of product damage. Separate the connectors by pulling gently while holding onto each connector. Do not

pull apart by the wires.

Perform the steps in the Disassemble the Faucetsection.

Pull up on the spout to separate it from the valve.

Disconnect the battery connectors by pulling gently on both connectors.

Reach inside the faucet body and gently pull the end of the battery clip up until it comes free from the two tabs.

Pull the battery and battery clip out of the faucet body.

Remove the battery from the battery clip.

Install a new battery into the battery clip.

If the sensor clip comes out with the battery clip, reinstall it according to the steps in the Replace the Sensor section.

Continue to the Reinstall the Battery Clip - DC Models Onlysection.

Kohler Co.

7

1025498-5-H

Service the Battery (cont.)

Reinstall the battery clip inside the faucet body.

NOTE: Connector Position 1is the preferred installation location for the connectors. Connector Position 2may also be used as an alternate installation location. Refer to the above illustration.

Position the connector tight to the battery clip in connector position 1 (DC models have one connector).

Slide the faucet spout over the valve assembly. It is important that the front of the spout line up with the pin at the bottom front of the valve assembly.

IMPORTANT! Verify that all the wires are inside the faucet body and are not pinched.

Convert to Tempered Water

To provide tempered water only, use a wrench to remove the hose for the hot water after first turning off the water supply to the faucet.

Replace the hose with the plug supplied and securely wrench tighten.

If applicable, install the vandal-resistant plug button. Refer to the Disassemble the Faucetsection to remove the handle.

Turn on the water supply to the faucet and check for leaks.

1025498-5-H

8

Kohler Co.

Sensor Clip

2

1

Connector

Position 2

Sensor

Connector

Position 1

 

 

Battery Clip

Battery Clip

 

Installation

Installed

 

Replace the Sensor

CAUTION: Risk of product damage. Do not disconnect the connectors by pulling on the wires.

Carefully disconnect the wires by pulling gently on the connectors.

Pull the loop outward to disengage the clip from the groove.

Rotate the clip counterclockwise.

Remove the old sensor.

Attach the new sensor wires to the connectors.

Install the sensor in the faucet, wire side first.

Align the sensor eyes with the holes in the spout.

Place the straight end of the clip into the hole in the retaining wall of the spout.

Pull the clip out until the bend in the clip is resting at the entrance to the groove. Avoid pinching the wires between the sensor and clip.

Push the clip in until it is firmly seated in the groove.

Kohler Co.

9

1025498-5-H

Replace the Sensor (cont.)

If applicable, see the Reinstall the Battery Clip - DC Models Onlysection to reinstall the battery and battery clip.

Proceed to the Reassemble the Faucetsection.

1025498-5-H

10

Kohler Co.

Flex

Hose

Housing

Screen

Adapter

Service the Filter

IMPORTANT! If the flow from the faucet decreases from its original volume, it is a possible indication that the in-line filters are partially blocked. Follow these procedures to clean the filters.

Turn off the water supplies.

Disconnect the flex hoses from the filter assemblies.

Remove the filter assemblies from the supply stops.

Using two wrenches, separate the housing from the adapter.

Remove the screen and clean all debris from the screen and the housing.

Return the screen to the housing, making sure the convex side of the screen faces the supply stop.

Thread the housing and adapter together.

Reattach the filter assemblies to the supply stops and flex hoses.

Kohler Co.

11

1025498-5-H

Plug

Diaphragm

Assembly

O-Ring

Faceplate

Screw

Service the Diaphragm

NOTE: Disassemble the faucet following the steps in the Disassemble the Faucetsection.

Disconnect the wire connectors and set the faucet body aside.

Using a Phillips screwdriver, remove the four screws.

Check the O-ring for wear. Replace if worn.

Remove the diaphragm from the back of the faceplate by gently prying it away with your fingers.

Rinse off any debris.

Position the replacement diaphragm and snap it into place.

Reinstall the faceplate and secure with the four screws.

Proceed to the Reassemble the Faucetsection.

Service the Plug

NOTE: Disassemble the faucet following the steps in the Disassemble the Faucetsection.

Disconnect the wire connectors and set the faucet body aside.

Use a hex wrench to remove the plug.

Install the replacement plug assembly and securely wrench tighten.

Proceed to the Reassemble the Faucetsection.

1025498-5-H

12

Kohler Co.

 

Screw

 

Solenoid Unit

Battery

O-Ring

Plug-In

 

O-Ring

 

 

O-Ring

Service the Solenoid

NOTE: Disassemble the faucet following the steps in the Disassemble the Faucetsection.

Disconnect the wire connector and set the faucet body aside.

Remove the two mounting screws using a Phillips screwdriver.

Remove the solenoid unit.

Position the new solenoid unit. Make sure the O-rings are properly positioned on the bottom of the solenoid.

Tighten the two mounting screws using a Phillips screwdriver. Proceed to the Reassemble the Faucetsection.

Kohler Co.

13

1025498-5-H

Vandal Resistant

Plug Button

Remove the Vandal-Resistant Plug

NOTE: Disassemble the faucet following the steps in the Disassemble the Faucetsection.

From inside the faucet body, use a screwdriver to pop out the vandal-resistant plug button.

If you are adjusting the temperature, go to the Optional Temperature Limiting Adjustmentsection and follow the instructions.

If you are installing the handle assembly, refer to the illustration in the Optional Temperature Limiting Adjustmentsection. Otherwise, reinstall the plug button.

Position the plug button and firmly press into place.

1025498-5-H

14

Kohler Co.

Sensor

 

 

Connector

Battery

Position 2

Connector

 

Connector

Position 1

Valve

Battery Clip

 

Reinstall the Battery Clip - DC Models Only

NOTE: When installing the battery and battery clip, make sure the wire and connector are accessible to allow for future connection.

With the battery clip angled slightly, insert it into the faucet body as shown above.

Engage one side of the battery clip into the left tab on the inner wall of the faucet body.

Press down firmly to snap the clip into the other tab. Verify that the clip is resting against the wall of the faucet body.

Proceed to the Reassemble the Faucetsection.

Kohler Co.

15

1025498-5-H

Mixer Valve

Service the Mixer Valve

NOTE: Disassemble the faucet following the steps in the Disassemble the Faucetsection.

Disconnect the connector(s).

Set the faucet body aside.

Remove the valve using an adjustable wrench.

Install the new valve. Tighten securely using an adjustable wrench.

Proceed to the Reassemble the Faucetsection.

1025498-5-H

16

Kohler Co.

 

 

 

Position 1

To Battery/Sensor

 

 

(preferred)

 

 

 

To Sensor

 

 

 

 

 

Position 2

 

AC

Important:

(alternate)

 

Connect with the

 

 

Models

 

 

arrows pointing

 

 

Only

 

 

toward each other.

Wire for

 

AC power

To Valve Assembly

To Power Supply

Reassemble the Faucet

For AC models only: Run the AC power cord through the front hole in the faucet valve to the underside of the deck.

IMPORTANT! Connect the connectors with the arrows pointing directly toward each other.

Reconnect the sensor connector to the valve connector.

NOTE: Position 1is the preferred installation location for the connectors. Position 2may also be used as an alternate installation location. Refer to the above illustration.

Position the valve/sensor connection tight to the battery clip in one of the connector positions illustrated above.

IMPORTANT! Verify that all the wires are inside the faucet body so they are not pinched while installing the valve assembly.

Line up the front of the spout with the pin at the bottom front of the valve assembly.

Slide the faucet spout over the valve assembly.

One-Year Limited Warranty — USA and Canada

KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year from date of installation.

Kohler Co. will, at its election, repair, replace or make appropriate

Kohler Co.

17

1025498-5-H

One-Year Limited Warranty — USA and Canada (cont.)

adjustment where Kohler Co. inspection discloses any such defects occurring in normal usage within one (1) year after installation. Kohler Co. is not responsible for removal or installation costs. Use of in-tank toilet cleaners will void the warranty.

To obtain warranty service contact Kohler Co. either through your Dealer, Plumbing Contractor, Home Center or E-tailer, or by writing Kohler Co., Attn.: Customer Service Department, 444 Highland Drive, Kohler, WI 53044, USA, or by calling 1-800-4-KOHLER from within the USA, 1-800-964-5590 from within Canada and 001-877-680-1310 from within Mexico.

Implied warranties including that of merchantability and fitness for a particular purpose are expressly limited in duration to the duration of this warranty. Kohler Co. and/or seller disclaims any liability for special, incidental or consequential damages.

Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state/province to state/province.

This is Kohler Co.’s exclusive written warranty.

Troubleshooting Guide

Symptoms

Probable

Recommended Action

 

Causes

 

 

1. No water

A.

There is a

A.

Remove the spout and check

flow (DC).

 

loose

 

the connection from the battery

 

 

connection.

 

to the solenoid and from the

 

 

 

 

solenoid to the sensor. Make

 

 

 

 

sure that the connector arrows

 

 

 

 

are aligned and that the

 

 

 

 

connection is secure.

 

B.

The wires

B.

Remove the spout and verify

 

 

are

 

that the wires are tucked inside

 

 

pinched or

 

the spout before reassembling.

 

 

damaged.

 

If the wires are cut or

 

 

 

 

damaged, order a new solenoid

 

 

 

 

or sensor assembly.

 

 

 

 

 

 

 

 

 

 

1025498-5-H

 

 

18

Kohler Co.

Troubleshooting Guide (cont.)

 

 

 

 

 

 

Symptoms

Probable

 

Recommended Action

 

Causes

 

 

 

 

C.

There is

 

C.

Remove the spout and check

 

 

water

 

 

for corrosion on the

 

 

leakage on

 

 

connections between the battery

 

 

electrical

 

 

to solenoid and the solenoid to

 

 

components

 

 

sensor. If possible, clean the

 

 

or

 

 

terminals. If unable to repair

 

 

connectors.

 

 

the connection, order a new

 

 

 

 

 

sensor assembly or solenoid

 

 

 

 

 

assembly, as required. Inspect

 

 

 

 

 

the O-ring on the valve for

 

 

 

 

 

cuts, debris, etc. If the O-ring is

 

 

 

 

 

damaged, order a new O-ring.

 

 

 

 

 

The origin of the leak must be

 

 

 

 

 

investigated and repaired.

 

D. The

 

D. Remove the spout and replace

 

 

battery life

 

 

the battery. The spout requires

 

 

has

 

 

a standard 6 Volt lithium

 

 

expired.

 

 

battery. This item is not

 

 

 

 

 

available from Kohler but can

 

 

 

 

 

be purchased at many stores

 

 

 

 

 

locally.

2. No water

A.

The AC

 

A.

Plug the AC wall brick firmly

flow (AC).

 

unit is not

 

 

into a working outlet.

 

 

plugged

 

 

 

 

 

in.

 

 

 

 

B.

The

 

B.

Check that the breaker for the

 

 

ground

 

 

circuit used by the faucet is on.

 

 

fault

 

 

 

 

 

breaker is

 

 

 

 

 

tripped.

 

 

 

 

C.

There is a

C.

Remove the spout and check

 

 

loose

 

 

the connection from the AC

 

 

connection.

 

 

unit to the solenoid and from

 

 

 

 

 

the solenoid to sensor. Make

 

 

 

 

 

sure that the connector arrows

 

 

 

 

 

are aligned and that the

 

 

 

 

 

connection is secure.

 

D. The wires

D. Remove the spout and verify

 

 

are

 

 

that the wires are tucked inside

 

 

pinched or

 

 

the spout before reassembling.

 

 

damaged.

 

 

If wires are cut or damaged,

 

 

 

 

 

order new solenoid or sensor

 

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

 

 

 

Kohler Co.

 

19

 

1025498-5-H

Troubleshooting Guide (cont.)

Symptoms

Probable

Recommended Action

 

Causes

 

 

 

E.

There is

E.

Remove the spout and check

 

 

water

 

for corrosion on connections

 

 

leakage on

 

between AC unit to solenoid

 

 

electrical

 

and the solenoid to sensor. If

 

 

components

 

possible clean terminals. If you

 

 

or

 

are unable to repair the

 

 

connectors.

 

connection, order a new battery

 

 

 

 

assembly or sensor assembly, as

 

 

 

 

required. The origin of the leak

 

 

 

 

must be investigated and

 

 

 

 

repaired.

 

F.

The AC

F.

Measure the voltage of the unit.

 

 

unit does

 

The voltage should measure 6

 

 

not work.

 

Volts. If there is no power or

 

 

 

 

low power is detected, order a

 

 

 

 

new unit.

3. No water

A.

Sensor

A.

Wipe the sensor eyes with a

flow (Either

 

eyes are

 

damp soft cloth. Wipe dry with

AC or DC).

 

dirty.

 

a dry soft cloth.

 

B.

Water not

B.

Verify that the water supply is

 

 

turned on.

 

turned on and that pressure is

 

 

 

 

at least 20 psi (137 kPa).

 

C.

Incorrect

C.

Verify that the faucet is

 

 

installation.

 

mounted flat to the deck

 

 

 

 

surface and that the sensor eyes

 

 

 

 

are aligned to the user area.

 

 

 

 

Ensure that the sensor eyes are

 

 

 

 

above the rim of the lavatory.

 

 

 

 

Refer to the installation

 

 

 

 

instructions.

 

D. The

D. Turn off the water supply and

 

 

filter(s) are

 

disconnect the fittings from the

 

 

plugged.

 

flex hoses. Remove the filter

 

 

 

 

cartridges from both supplies.

 

 

 

 

Clean all debris from the filter

 

 

 

 

screens and reinstall the

 

 

 

 

screens, and reinstall the filter

 

 

 

 

cartridges.

 

E.

The

E.

Remove the aerator and clean.

 

 

aerator is

 

For calcium/mineral deposits,

 

 

plugged.

 

soak the plastic insert in a 50:50

 

 

 

 

mix of water and vinegar. Soak

 

 

 

 

only the plastic insert.

 

 

 

 

 

1025498-5-H

20

Kohler Co.

Troubleshooting Guide (cont.)

 

 

 

 

 

 

Symptoms

Probable

 

Recommended Action

 

 

Causes

 

 

 

 

 

F.

Sensor

 

F.

Replace the sensor assembly.

 

 

 

eyes are

 

 

 

 

 

 

scratched.

 

 

 

 

 

G. The bleed

G. Turn off the water supply.

 

 

 

hole in the

 

 

Remove valve cover and

 

 

 

diaphragm

 

 

diaphragm assembly. Clean any

 

 

 

is plugged

 

 

debris from the area and

 

 

 

or the

 

 

reinstall the components.

 

 

 

plunger is

 

 

 

 

 

 

stuck.

 

 

 

 

 

H. A flex hose

H. Check the flex hoses to make

 

 

 

is kinked.

 

 

certain they are not kinked. If

 

 

 

 

 

 

a flex hose is kinked,

 

 

 

 

 

 

disconnect it from the filter

 

 

 

 

 

 

cartridge, straighten, and

 

 

 

 

 

 

reconnect.

4.

Low flow

A.

Supply

 

A.

Check any filtration systems for

 

(either AC or

 

pressure is

 

 

blockage. Check incoming

 

DC).

 

low.

 

 

water pressure. Pressure should

 

 

 

 

 

 

be at least 20 psi (137 kPa).

 

 

B.

Filters are

 

B.

Turn off water supply and

 

 

 

plugged.

 

 

disconnect fittings from supply

 

 

 

 

 

 

lines. Remove filter cartridges

 

 

 

 

 

 

from both supply lines. Clean

 

 

 

 

 

 

debris from screens and

 

 

 

 

 

 

reinstall the cartridges.

 

 

C.

Aerator is

 

C.

Remove the aerator and clean

 

 

 

plugged.

 

 

it. For calcium/mineral

 

 

 

 

 

 

deposits, soak the aerator

 

 

 

 

 

 

plastic insert in a 50:50 mixture

 

 

 

 

 

 

of vinegar and water. Soak only

 

 

 

 

 

 

the insert and no other

 

 

 

 

 

 

components.

5.

Constant

A.

Battery life

 

A.

Remove spout and replace

 

water flow

 

expired.

 

 

battery. Use a standard 6 Volt

 

(DC).

 

 

 

 

lithium battery. This item is not

 

 

 

 

 

 

available from Kohler but can

 

 

 

 

 

 

be purchased at many stores

 

 

 

 

 

 

locally.

6.

Constant

A.

The power

 

A.

Once the power is stable,

 

water flow

 

source is

 

 

unplug the unit and plug back

 

(AC).

 

unstable,

 

 

into wall.

 

 

 

off, or the

 

 

 

 

 

 

circuit is

 

 

 

 

 

 

blown.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kohler Co.

 

21

 

1025498-5-H

Troubleshooting Guide (cont.)

 

 

 

 

 

Symptoms

Probable

Recommended Action

 

 

Causes

 

 

7.

Constant

A.

The

A.

Turn off the water supply and

 

water flow

 

diaphragm

 

purge the faucet. Remove the

 

(Either AC or

 

seal dirty

 

valve front plate and check the

 

DC).

 

or

 

diaphragm and surrounding

 

 

 

damaged.

 

area for debris. Clean out any

 

 

 

 

 

debris. If the diaphragm is

 

 

 

 

 

damaged, order a replacement.

 

 

B.

The

B.

Remove the spout and

 

 

 

solenoid is

 

solenoid. Check the solenoid

 

 

 

plugged.

 

holes for debris.

 

 

C.

The

C.

Remove the spout and

 

 

 

solenoid is

 

solenoid. Replace the solenoid.

 

 

 

does not

 

 

 

 

 

work.

 

 

 

 

D. The

D. Turn off the water supply and

 

 

 

filter(s) are

 

disconnect the fittings from the

 

 

 

plugged.

 

flex hoses. Remove the filter

 

 

 

 

 

cartridges from both supplies.

 

 

 

 

 

Clean all debris from the

 

 

 

 

 

screens and replace them in the

 

 

 

 

 

unit.

8.

Sporadic

A.

The faucet

A.

Verify that the faucet is

 

water flow.

 

is installed

 

mounted flat to the deck

 

 

 

at wrong

 

surface and that the sensor eyes

 

 

 

angle to

 

are aligned to the user area.

 

 

 

deck or

 

Ensure that the faucet is

 

 

 

misaligned

 

installed in a position that is

 

 

 

with user

 

above the rim of the lavatory.

 

 

 

area.

 

 

 

 

B.

The wires

B.

Remove the spout and verify

 

 

 

are

 

that the wires are tucked inside

 

 

 

pinched or

 

the spout before reassembling.

 

 

 

damaged.

 

 

9.

Water is

A.

The valve

A.

Order a new O-ring for the

 

dripping on

 

O-ring is

 

valve and install.

 

deck

 

missing,

 

 

 

 

 

cut, or

 

 

 

 

 

damaged.

 

 

 

 

 

 

 

 

 

 

 

 

1025498-5-H

 

 

22

Kohler Co.

Troubleshooting Guide (cont.)

Symptoms

Probable

Recommended Action

 

 

Causes

 

10.

Sensor

A.

The

A. Replace the battery. The

 

flashes once

 

battery

product may continue to

 

approximately

 

power is

operate for several days with

 

every 8

 

low.

low battery power. The product

 

seconds. The

 

 

requires a 2CR5 6 V lithium

 

product

 

 

battery. This item is not

 

continues to

 

 

available from Kohler Co. but

 

operate.

 

 

can be purchased at a local

 

 

 

 

retail store.

11.

Sensor

A.

The

A. Replace the battery. The

 

flashes once

 

battery

product requires a 2CR5 6 V

 

approximately

 

power is

lithium battery. This item is not

 

every 2

 

insufficient

available from Kohler Co. but

 

seconds. The

 

to allow

can be purchased at a local

 

product does

 

the

retail store.

 

not operate.

 

product to

 

 

 

 

operate.

 

 

 

 

 

 

Kohler Co.