No part of this manual may be reproduced in
any form or by any means (including
electronic storage and retrieval or
translation into a foreign language) without
prior agreement and written consent from
Keysight Technologies, Inc. as governed by
UnitedStates and international copyright
laws.
Trademarks
WiMAXand Mobile WiMAX are US
trademarks of the WiMAXForum.
Manual Part Number
N9041-90006
Edition
Edition: 1, July 2019
Published in USA
Published by:
Keysight Technologies, Inc.
1400 Fountaingrove Parkway
SantaRosa, CA 95403
Technology Licenses
The hardwareand/or software described in
this document arefurnished under a license
and may beused or copied only in
accordance with the terms of such license.
The Software is “commercial computer
software,” as defined by Federal Acquisition
Regulation (“FAR”)2.101. Pursuant to FAR
12.212 and 27.405-3 and Department of
Defense FAR Supplement (“DFARS”)
227.7202, the USgovernment acquires
commercial computer softwareunder the
same terms by which the software is
customarily provided to the public.
Accordingly, Keysight provides the Software
to US government customers under its
standard commercial license, which is
embodiedin its End User License Agreement
(EULA), a copy of which can be found at
http://www.keysight.com/find/sweula. The
licenseset forth in the EULArepresents the
exclusive authority by which the US
government may use, modify, distribute, or
disclose the Software. The EULAand the
licenseset forth therein, does not require or
permit, among other things, that Keysight:
(1) Furnish technical information related to
commercial computer softwareor
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish to,
or otherwiseprovide, the government rights
in excess of theserights customarily
provided to the publicto use, modify,
reproduce, release, perform, display, or
disclose commercial computer software or
commercial computer software
documentation. No additional government
requirements beyond those set forth in the
EULAshall apply, except to the extent that
those terms, rights, or licenses are explicitly
required from all providers of commercial
computer software pursuant to the FAR and
the DFARSand are set forth specifically in
writing elsewhere in the EULA. Keysight shall
be under no obligation to update, revise or
otherwisemodify the Software. With respect
to any technical dataas definedby FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the US
government acquires no greater than
Limited Rights as defined in FAR 27.401 or
DFAR 227.7103-5 (c), as applicablein any
technical data.
THE MATERIALCONTAINED IN THIS
DOCUMENT IS PROVIDED“AS IS,” AND IS
SUBJECT TO BEING CHANGED, WITHOUT
NOTICE, IN FUTURE EDITIONS. FURTHER,
TO THE MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT DISCLAIMS
ALL WARRANTIES, EITHER EXPRESSOR
IMPLIED, WITH REGARD TO THISMANUAL
AND ANY INFORMATION CONTAINED
HEREIN, INCLUDING BUT NOT LIMITED TO
THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESSFOR A
PARTICULAR PURPOSE. KEYSIGHT SHALL
NOT BE LIABLEFOR ERRORS OR FOR
INCIDENTAL OR CONSEQUENTIAL
DAMAGESIN CONNECTION WITH THE
FURNISHING, USE, OR PERFORMANCE OF
THIS DOCUMENT OR OF ANY
INFORMATION CONTAINED HEREIN.
SHOULD KEYSIGHT AND THE USER HAVEA
SEPARATE WRITTEN AGREEMENT WITH
WARRANTY TERMS COVERING THE
MATERIAL IN THIS DOCUMENT THAT
CONFLICT WITH THESE TERMS, THE
WARRANTY TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.
Safety Information
A CAUTION notice denotes a hazard. It calls
attention to an operating procedure,
practice, or the like that, if not correctly
performed or adhered to, could result in
damage to the product or loss of
important data. Do not proceed beyond a
CAUTION notice until the indicated
conditions are fully understood and met.
A WARNING notice denotes a hazard. It
calls attention to an operating procedure,
practice, or the like that, if not correctly
performed or adhered to, could result in
personal injury or death. Do not proceed
beyond a WARNING notice until the
indicated conditions are fully understood
and met.
2User's Guide
Page 3
Contents
1 Keysight Connector Kit5
Connector Kit Overview6
Use of the Test Port Adaptors on Instrument RF Input 27
Input Connector Vise Assembly8
RF Input 1, 2.4 mm adaptor installation10
2 Connector Care11
Visual Inspection12
Obvious defects or damage12
Connector Contacts13
Contact integrity13
Concentricity13
Making Connections15
Connection Procedure15
Cleaning Connectors16
Basic Cleaning Procedure16
Replacement Parts17
User's Guide3
Page 4
4User's Guide
Page 5
Keysight X-Series Signal Analyzer
User's Guide
1 Keysight Connector Kit
"Connector Kit Overview" on page 6
"Use of the Test Port Adaptors on Instrument RF Input 2" on page 7
"Input Connector Vise Assembly " on page 8
5
Page 6
1 Keysight Connector Kit
Connector Kit Overview
Connector Kit Overview
The N9041B, Signal Analyzer has two input connectors, the right side RF Input 1
connector is a 2.4 mm male.
The left side RF Input 2 connector is a special 1.0 mm male Keysight bulk head
connector that has 14 mm wrench flats. This test port connector has external
threads that accept the Keysight Test port adaptors, and has internal threads that
will accept Keysight standard 1.0 mm female adaptor, such as the 11920B.
The Connector Kit contains:
Adaptor - 2.4 Female to K FemaleUsed on RF Input 1 as a connector saver to
connect 3.5 mm or sma devices or cables.
Adaptor 2.4 mm Female- 2.4 mm FemaleUsed on RF Input 1 as a connector saver
1 mm female test port to 1 mm female adaptorUsed on RF Input 2 as a connector saver
1 mm female test port to 1.85 mm female adaptorUsed on RF Input 2 as a connector saver and to
connect 1.85 mm devices or cables
Torque WrenchDouble ended wrench with 10 inch-pound (setting
for test port adaptors) and 4 inch-pound (setting
for Keysight standard 1 mm adaptors)
Connector Vise for RF Input 2If the test port adaptors cannot be used, this vise
will help secure a Keysight standard 1 mm female
adaptor to the instrument RF Input 2 connector.
Open ended wrenches required (not supplied)
– 7 mm (Used on 11900B and 11904B)
– 8 mm (Used on Y1901B)
– 12 mm (Used on Y1900B)
6User's Guide
Page 7
1 Keysight Connector Kit
Use of the Test Port Adaptors on Instrument RF Input 2
Use of the Test Port Adaptors on Instrument RF Input 2
Two, 1mm test port adaptors are supplied in the kit. The 1 mm female test port to
1 mm female adaptor is used as a connector saver to extend the lifespan of the
instrument RF Input 2 connector. The other test port adaptor is a 1mm female test
port to 1.85 mm female adaptor. This adaptor is also a connector saver.
USE CAUTION WHEN INSTALLING ADAPTORS! Rotation of the adaptor after the
connectors are engaged will damage the input connector on the instrument.
1. Align the test port adaptor with the 1 mm RF Input 2 connector on the instrument
and engage the nut of the input connector with the adaptor. Fully engage the
threads, but do not attempt to fully torque the connection.
2. Locate the torque wrench in the kit.
a. If connecting the 1 mm to 1 mm adapter, locate a 12 mm open end wrench.
b.
If connecting the 1 mm to 1.85 mm adapter, locate a 8 mm open end wrench.
3. Place the jaws of the open end wrench onto the test port adaptor wrench flats,
but do not turn this wrench.
4. Place the jaws of the 10-inch-pounds end of the torque wrench onto the
instrument RF Input 2 connector. While holding the test port adaptor still with
the open end wrench, torque the input connector to 10- inch-pounds.
Keysight Technologies recommends the use of the supplied Keysight Technologies
test port adaptors when using RF Input 2, the 1 mm input connector. The test port
adaptors attach to the external threads on the instrument bulkhead input connector.
However, if Keysight Technologies standard adaptors will be used instead of the test
port adaptors, the use of the supplied Connector Vise assembly is recommended to
prevent damage to the 1 mm input connector due to over torque.
Standard adaptors other that those manufactured by Keysight Technologies may
not work with the Vise Clamp.
USE CAUTION WHEN INSTALLING ADAPTORS! Rotation of the adaptor after the
connectors are engaged will damage the input connector on the instrument.
To use Keysight Technologies standard adaptors with the Vise Clamp:
1. Install the Vise Clamp with the two supplied pan-head screws. Tighten the
screws to 9 inch-pounds.
2. Loosen the Vise Clamp screw so that the vise jaws clear the body of the standard
adaptor that is to be used.
3. Align the flats of the 1 mm female end of the adaptor with the vise jaws and
tighten the Vise Clamp screw until the jaws grip the adaptor. Loosen the screw
slightly to allow the adaptor to slide in the jaws.
4. Align the adaptor with the 1 mm input connector on the instrument and engage
the nut of the input connector with the adaptor. Fully engage the threads, but do
not attempt to fully torque the connection.
5. Re-align the jaws of the vise so they make good contact with the flats on the
adaptor. Do this by pulling back on the vise jaws while tightening the vise clamp
screw. DO NOT OVER TIGHTEN.
6. Tighten the input connector nut to 4 inch-pounds using the 4-inch-pounds end of
the 14 mm torque wrench.
7. Re-tighten the vise clamp screw to snugly lock the jaws against the flats of the
adaptor. DO NOT OVER TIGHTEN.
8. If the standard adaptor will remain on the input connector for a long period of
time, periodically check the Vise Clamp screw to ensure that it remains snugly
tightened.
8User's Guide
Page 9
1 Keysight Connector Kit
Input Connector Vise Assembly
The Vise Clamp will now protect the input connector from damage when
connections are made to the adaptor that exceed 4 inch-pounds torque. The Vise
Clamp is only a rotation prevention device. It will not protect the input connector
against damage from bending due to heavy side to side or up/down loading on the
adaptor.
Align the adaptor with the 2.4 mm input connector on the instrument and engage the
nut of the input connector with the adaptor.
Torque the bulkhead 2.4 mm input connector (with an 8 mm or 5/16" torque wrench)
to 8 inch-pounds while holding the adaptor with a 7 mm open-end wrench.
Refer to "Connector Care" on page 11.
10User's Guide
Page 11
Keysight X-Series Signal Analyzer
User's Guide
2 Connector Care
"Visual Inspection" on page 12
"Connector Contacts" on page 13
"Making Connections" on page 15
"Cleaning Connectors" on page 16
"Replacement Parts" on page 17
11
Page 12
2 Connector Care
Visual Inspection
Visual Inspection
Visual inspection and , if necessary cleaning should be done every time a connection
is made. Metal particles from connector threads may fall into the connector when it
is disconnected. One connection made with a dirty or damaged connector can
damage both connectors beyond repair.
Magnification is helpful when inspecting connectors, but it is not required and may
actually be misleading. Defects and damage that cannot be seen without
magnification generally have no effect on electrical or mechanical performance.
Magnification is of great use in analyzing the nature and cause of damage and in
cleaning connectors, but it is not required for inspection.
Obvious defects or damage
Examine the connectors first for obvious defects or damage:
– Plating
– Bare metal showing
– Burrs or blisters
– Deformed threads
– Center conductors
– Bent
– Broken
– Misaligned
– Concentricity
– Connector nuts should move smoothly and be free of:
– Burrs
– Loose metal particles
– Rough spots
Any connector that has obvious defects should be discarded.
12User's Guide
Page 13
Connector Contacts
Inspect the connector contacts for integrity. It is necessary to use good lighting (such
as a halogen task light) to see the contacts.
Notice the location of the cross hairs in relationship to the center of the figures.
Contact integrity
Refer to the following for visual guidelines when evaluating the contact integrity of a
connector.
2 Connector Care
Connector Contacts
Concentricity
The following examples show the concentricity of both the male and female 1.0 mm
connectors:
Female connector:
User's Guide13
Page 14
2 Connector Care
Connector Contacts
Male connector:
14User's Guide
Page 15
Making Connections
Good connections require a skilled operator. Instrument sensitivity and coaxial
connector mechanical tolerances are such that slight errors in operator technique
can have a significant effect on measurements and measurement uncertainties.
The most common cause of measurement error is poor connections.
Connection Procedure
1. Ground yourself and all devices (wear a grounded wrist strap and work on an
antistatic mat).
2. Visually inspect the connectors (refer to Visual Inspection).
3. If necessary, clean the connectors (refer to Cleaning Connectors).
4. Carefully align the connectors. The male connector center pin must slip
concentrically into the contact fingers of the female connector.
2 Connector Care
Making Connections
5. Push the connectors straight together. Do not twist or screw them together. As
the center conductors mate, there is usually a slight resistance.
6. Do not twist one connector into the other (like insertinga light
bulb). This happens when you turn the device body, rather than the
connector nut. Major damage to the center conductor and the outer
conductor can occur if the device body is twisted.
7. Initial tightening can be done by hand or with an open-end wrench. Tighten until
"snug" or where the connectors are first making contact. The preliminary
connection is tight enough when the mating plane surfaces make uniform, light
contact. Do not over tighten this connection.
At this point, all you want is for the outer conductors to make gentle contact on
both mating surfaces. Use very light finger pressure (no more than 2 inch-pounds
of torque).
8. Relieve any side pressure on the connection from long or heavy devices or
cables. This assures consistent torque.
9. Torque the cable or device to the final value using a torque wrench.
User's Guide15
Page 16
2 Connector Care
Cleaning Connectors
Cleaning Connectors
Basic Cleaning Procedure
1. Inspect the connectors for dust, dirt, metal fragment, oils or film, and debris.
2. Blow off any dust with a filtered, clean supply of compressed air.
3. Add a few drops of high-purity isopropyl alcohol to a small cleaning swab (do not
apply alcohol directly to the parts).
4. When using isopropyl alcohol to clean connectors do not allow the
liquid to flow down inside the connector. This may cause
measurement errors due to residue inside the connector. If possible
keep the connector facing down.
5. Gently wipe connecting surfaces with the end of the cleaning swab.
6. Blow dry with compressed air.
7. Inspect and repeat cleaning procedure if necessary.
16User's Guide
Page 17
Replacement Parts
DescriptionOrdering number
Test Port Adaptor, 1mm (f) to 1mm (f)Y1900B
Test port Adaptor, 1mm (f) to 1.85mm (f)Y1901B
2.4 mm (f) to 2.4 mm (f),11900B
2.4 mm (f) to 2.92 mm (f),11904B
2 Connector Care
Replacement Parts
Wrench-Torque Special Double-end 14mm-open end 4 and
10-lb-in