KEYENCE SJ-M201 User Manual

0 (0)

96M11367

High-performance

Micro Static Eliminator

SJ-M201

Instruction Manual

Before using this Compact Static Eliminator, be sure to thoroughly read this Instruction Manual.

After you are finished with this Instruction Manual, be sure to store it in a safe place for quick reference.

Introduction

This document describes handling, method of operation and precautions when using the Compact Spot-type Static Eliminator SJ-M201 Series. Before you start to use the SJ-M201 Series, be sure to thoroughly read this document in order to make full use and safely use its functions.

Store this document in a safe place so that you can retrieve it whenever necessary.

Symbols

The following symbols alert you to important messages. Be sure to read these messages carefully.

 

 

 

 

It indicates a hazardous situation which, if not avoided, will result in death or

 

DANGER

 

 

 

 

 

serious injury.

 

 

 

 

 

 

 

 

 

It indicates a hazardous situation which, if not avoided, could result in death

 

WARNING

 

 

 

 

 

or serious injury.

 

 

 

 

 

 

 

 

 

It indicates a hazardous situation which, if not avoided, could result in minor

 

CAUTION

 

or moderate injury.

 

 

 

 

 

 

 

 

 

It indicates a situation which, if not avoided, could result in product damage

 

NOTICE

 

 

 

 

 

as well as property damage.

 

 

 

 

 

 

 

 

 

 

 

 

 

It indicates cautions and limitations that must be followed during operation.

 

Important

 

 

 

 

 

 

 

 

 

 

It indicates additional information on proper operation.

 

Point

 

Reference It indicates tips for better understanding or useful information.

Indicates the reference pages in this manual or the reference pages in separate manuals.

Safety Information for SJ-M Series

n General Precautions

Do not use this product for the purpose to protect a human body or a part of human body.

WARNING

• This product is not intended for use as explosion-proof product. Do not

use this product in hazardous location and / or potentially explosive

 

 

atmosphere.

You must verify that the SJ-M Series is operating correctly in terms of functionality and performance before the start and during the operation of

 

CAUTION

 

the SJ-M Series.

 

 

We recommend that you take substantial safety measures to avoid any

 

 

 

damage in the event of a problem occurring.

 

 

 

 

 

 

KEYENCE never warrants the function or performance of the SJ-M201

 

 

 

Series if it is used in a manner that differs from the SJ-M201 Series

 

 

 

specifications contained in this instruction manual or if the SJ-M201 Series

 

NOTICE

 

 

 

is modified by yourself.

When the SJ-M201 Series is used in combination with other instruments, functions and performance maybe degraded, depending on operating conditions and the surrounding environment.

n SJ-M Series Handling Precautions

Ensure you use only in well-ventilated areas as the ozone released from the device can become harmful if used in an enclosed space. Do not place your face close to the end of the Static Elimination Head. The ozone

 

WARNING

 

released from the head can cause damage to the nose and/or throat.

 

 

Do not touch static elimination head after turning the power on.

 

 

 

High voltage may occur on the surface of this product when neutralizing

 

 

 

highly-charged objects.

 

 

 

 

 

 

 

 

• To prevent electric shock and to ensure accurate static elimination, be sure

 

 

 

to connect a Class D earth (maximum resistance of 100 Ohms).

 

 

The accessory AC power cable to Power SJ-UI/SJ-U2 (sold separately), is

 

 

 

rated for AC 100 to 125 V and is specifically for use in Japan.

 

 

 

When using the SJ-M Series outside of Japan, you cannot use the AC

 

 

 

Power Cable described above. Use an AC Power cable best suited to the

 

 

 

regulations and standards of the country or region the SJ-M Series is

 

 

 

going to be used.

 

 

Do not use this product in locations where there is the risk of ignition or

 

 

 

explosion from flammable solvents or dirt and dust.

 

 

• High voltage is applied to this product. Prevent it from being splashed with

 

 

 

water, oil, or flammable solvents. Failure to do so may cause insulation

 

CAUTION

 

breakdown, which will result in electric shock or malfunction.

Do not bring your fingers, tools, wire or other metallic objects near this product. Doing so may cause injury, electric shock, or malfunction.

Do not operate this product with wet hands. Doing so may cause electric shock.

Before starting inspection or maintenance, be sure to turn the power OFF. Failure to do so might result in electric shock or malfunction.

During maintenance, do not directly touch the electrode probe. Doing so may cause personal injury.

Supply air according to the deratings indicated in the specifications. Use without performing derating might result in electric shock or malfunction

If any malfunction is observed in this product, immediately turn it OFF, and contact your nearest agent. You should never repair this product yourself. Doing so may cause electric shock or malfunction.

Use this product for static elimination only. Do not use it for other purposes.

 

Protect the area around the tip of the Static Elimination Head with silicon,

 

 

fluoro-resin or other highly ozone-resistant resin.

 

• Do not use this product in locations where sudden changes in temperature

 

 

or condensation are likely to occur.

 

Do not touch the electrode probe with a tool or other hard object. Damage

 

 

to the electrode probe will prevent static elimination performance from

 

 

being fully demonstrated, and cause accidents or malfunction.

 

When this product is used for a long period of time, the electrode probe

 

 

may become dirty due to the adhesion of dust and dirt. If the ion level

 

 

alarm indicator or condition alarm indicator lights, clean the electrode

CAUTION

 

 

probe. If the product is used with the electrode probe in a dirty or dusty

 

 

state, the static elimination performance can no longer be fully

 

 

demonstrated, resulting in accidents or malfunction. We recommend

 

 

periodically cleaning the electrode probe (as a guideline, once every two

 

 

weeks in a regular operating environment though this depends on the

 

 

installation conditions).

Do not drop or subject this product to shock. Doing so might result in accident or malfunction.

When installing the SJ-M Series, observe the minimum bending radius of all provided cables. Also, do not install the SJ-M with the cables deformed by staples or other objects. Doing so might cause the SJ-M to malfunction.

Air For Supply

 

The only gas that can be supplied to the SJ-M201 is air.

 

The compressed air flowing from the compressor contains drain such as

 

 

water and oil. Please remove drains from air by using filters or air dryers

CAUTION

 

 

before use.

When the gas contains foreign materials, remove them by use of filters or the likes.

Power Supply Precautions

CAUTION Use a rated power supply.

• Noise applied to the power supply may cause this product to malfunction.

If this happens, install an insulated transformer.

NOTICE • When using a switching regulator, be sure to connect a Class D earth to the Frame Ground terminal.

Air Purge Function Precautions

Be sure to use air of pressure 0.001 MPa to 0.5 MPa. Use outside of the rated air pressure range might result in accidents or malfunction.

Be sure to supply clean, dry air of temperature -20°C or more through a

CAUTION filter of mesh size about 0.01μm. Moisture or oil contained in the air or nitrogen may cause discharge inside the Static Elimination Head, which may result in accidents or malfunction.

1

n SJ-M Series Warning label

A WARNING label is affixed on the SJ-M Series to ensure safety. Read the description on this WARNING label to ensure correct use of the SJ-M Series.

WARNING labels in Japanese, German, French, Italian and Chinese (Simplified) are provided. Use them as necessary.

n Installation Precautions

Avoid installing the SJ-M Series in the following locations as this may cause accidents.

 

Locations directly subject to vibration and shock

 

Locations subject to ambient temperature outside of the 0°C to +40°C

 

 

range (excluding the High-voltage Cable Unit)

 

Locations subject to ambient temperature outside of the 0°C to +80°C

 

 

range (High-voltage Cable Unit)

 

Locations subject to ambient humidity outside of the 35 to 65%RH range

 

 

(condensation not allowed) (excluding the High-voltage Cable Unit)

 

Locations subject to ambient humidity outside of the derating range

 

 

(condensation not allowed) indicated in the specifications (High-voltage

CAUTION

 

 

Cable Unit)

 

 

 

Locations subject to sudden changes in temperature

 

Locations subject directly to blasts from air conditioners

 

Locations subject to volatile or flammable substance, solvents or

 

 

corrosive gases

 

Locations subject to large amounts of dirt, and dust, salt, iron and oil

 

 

smoke

 

Locations that may be splashed with water, oil or chemical mist

 

Locations where strong magnetic and electrical fields are generated

n About Warm-up

Point After turning the SJ-M Series ON, wait for about 20 minutes to allow the ion balance to stabilize.

Precautions on Regulations and Standards

n CE Marking

Keyence corporation has confirmed that this product complies with the essential requirements of the applicable EC Directives, based on the following specifications. Be sure to consider the following specifications when using this product in the Member States of European Union.

EMC Directive (2004/108/EC)

• Applicable Standard EMI

:

EN61326-1, ClassA

EMS

:

EN61326-1

Be sure to provide a ground when installing the SJ-M Series.

The length of all input/output cables must be less than or equal to 30 m.

Attach a one-loop ferrite core onto the High-voltage Cable Unit and pass the connector cable once through the core.

The following ferrite core is recommended:

SFC-10 made by KITAGAWA INDUSTRIES CO,LTD. Remarks:

These specifications do not give any guarantee that the end-product with this product incorporated complies with the essential requirements of EMC Directive. The manufacturer of the end-product is solely responsible for the compliance on the end-product itself according to EMC Directive.

Low-Voltage Directive (2006/95/EC)

• Applicable Standard : EN61010-1

Overvoltage category I

Use this product under pollution degree 2

Use this product at the altitude of 2000 m or less.

Indoor use only.

Use the following power supply.

-The power supply that satisfies the requirements of the Limited Power Source specifications stipulated in EN60950 and certified by European third-party certification organization

-Keyence Corporation AC adapter (SJ-U1/SJ-U2)

n CSA Certificate

This product complies with the following CSA and UL standards and has been certified by CSA . Be sure to consider the following specifications when using this product as a product certified by CSA.

• Applicable Standard : CAN/CSA C22.2 No.61010-1,

UL61010-1

Overvoltage category I

Use this product under pollution degree 2

Use this product at the altitude of 2000 m or less.

Indoor use only.

Use the following power supply.

-CSA/UL-listed power supply that provides Class 2 output as defined in the CEC (Canadian Electrical Code) and NEC (National Electrical Code)

-CSA/UL power supply that has been evaluated as a Limited Power Source as defined in CAN/ CSA-C22.2 No. 60950-1/UL60950-1

-Keyence Corporation AC adapter (SJ-U1/SJ-U2)

Other Precautions

Be sure to follow all procedures described in each section of this instruction manual.

 

WARNING

• This SJ-M201 Series uses EEPROM. Do not power off the unit while it is

 

 

 

being set.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install the tip of the SJ-M021(G) paying attention to the following point.

 

 

zInstall the Static Elimination Head away from the wall or surrounding

 

 

 

objects.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SJ-M021(G)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 mm or more

 

 

 

 

 

 

 

10 mm or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 mm

 

 

 

 

 

 

 

 

 

 

 

 

10 mm

 

 

 

 

 

 

 

 

 

or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23mm*

 

 

 

Requires 10 mm or more away

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from the air outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The section marked by "*" must not touch the conductor (earthed body).

 

 

 

 

 

 

The adapter nozzle must not touch the conductor (earthed body).

 

 

 

 

 

 

 

zProtect the area around the tip of the Static Elimination Head with silicon,

 

 

 

fluoro-resin or other highly ozone-resistant resin. Ozone that is generated

 

 

 

may cause the metal or resin on the SJ-M021(G) to rust, corrode or

 

 

 

deteriorate.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SJ-M021(G)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 mm or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 mm

 

 

 

 

 

 

200 mm

or more

 

 

 

20 mm or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or more

 

 

 

 

 

 

or more

 

 

 

 

 

 

 

When SJ-MS2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is used

 

 

 

 

20 mm

 

 

 

 

20 mm

20 mm

 

 

20 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or more

 

 

 

or more

or more

 

 

or more

 

 

 

 

 

 

 

20 mm or more

 

 

 

 

 

10 mm

 

 

 

 

 

 

 

 

10 mm

 

 

 

 

 

 

 

 

 

 

 

 

or more

 

 

 

 

 

 

 

 

or more

10 mm

 

 

 

 

 

200 mm or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When SJ-MS1

 

 

20 mm or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is used

 

 

 

 

 

 

 

When SJ-ML1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is used

 

 

 

 

 

200 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or more

 

 

 

200 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 mm

 

 

20 mm

 

 

or more

20 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or more

 

 

or more

 

 

 

 

 

or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 mm

10 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or more

or more

20 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When SJ-MS3 is used

 

 

 

 

When SJ-ML2 is used

 

 

 

 

 

 

 

 

 

 

 

 

Do not install the Static Elimination Head at locations where moving parts of other equipment and machinery may place stress on the cable. Doing so might cause the SJ-M021(G) to malfunction.

1-1 Features of the SJ-M Series

This section describes an outline of the functions and features of the SJ-M Series.

Outline of the SJ-M Series

Pulse AC method

The SJ-M Series uses a pulse AC method that generates + and – charged air ions from a single electrode probe. This system ensures a maximum ion level per unit time, and therefore high-speed static elimination. The SJ-M Series also automatically controls the level of + and – ions generated based on the charged state of the target object. This enables high-speed and high-precision static elimination.

I.C.C. (Ion Current Control) method

This control method calculates the charged level of the target object by sensing the state of ion current that arises due to the potential difference between the electrode on the Static Elimination Head and GND. Optimum static elimination based on the state of the target object can be performed by rapidly supplying the optimum ions suited to the polarity and charged level of the target object.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elimination of

 

ions

Elimination of

 

ions

Regular state

from target object

from target object

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Target object in

Target object

Target object

non-charged state

charged

charged

Ion monitor functions

Charge monitor

The integrated ion monitor allows you to see how much the target object is charged by + or – ions. This monitor also allows you to confirm at a glance how static elimination is being performed.

Ion level monitor

The ion level currently being generated by the Static Elimination Head is monitored at all times so that drops in the generated ion level can be diagnosed on the unit. The generated ion level is indicated by LEDs and an alarm can be output when the generated ions fall below a certain level. This allows you to monitor the influence of a dirty electrode probe in advance.

"Ion Monitor Functions" (page 10)

2

1-1 Features of the SJ-M Series

Alarm output functions

Alarm output functions

An indicator blinks and an alarm signal is output, for example, when internal circuits are damaged or abnormal discharging occurs. When an alarm signal is output, generation of ions is forcibly stopped.

Ion level alarm output function

An indicator lights and an alarm signal is output when the level of generated ions drops due to a dirty electrode probe, for example.

Condition alarm output function

An indicator lights and an alarm signal is output when static elimination performance is impaired.

"Alarm Output Functions" (page 10)

Abnormal discharge detection function

Abnormal discharge caused by condensation on the electrode probe tip or adhesion of debris is detected. When abnormal discharge is detected, ion generation is forcibly stopped to prevent malfunction at an early stage.

"Abnormal Discharge Detection Function" (page 10)

Ion balance adjustment function

The ion balance zero point can be fine-tuned.

"Ion Balance Adjustment Function" (page 9)

Static elimination stop function

Static elimination only can be turned ON/OFF with the device still powered. This is achieved by shorting the 0V terminal with the static elimination stop input terminal on the Controller Unit (I/O terminal section) or by holding down the two ion balance adjustment keys simultaneously for about three seconds.

"Static Elimination Stop Function" (page 10)

Air purge function

Dirt can be prevented from sticking to the electrode probe on the SJ-M021(G) by attaching a tube to the air duct and supplying clean, dry air. This also extends the static elimination range.

"Air Purge Function" (page 10)

High-temperature static elimination

The High Temperature global setting allows static to be eliminated in hot environments. (ambient operating temperature: SJ-M021(G), 0 to +80°C)

"High temperature use setting" (page 8)

1-2 Checking the Contents of the Package

The package contains the following components and accessories. Before you start using the SJ-M Series, make sure that the package contains everything that it is supposed to contain. A Replacement Electrode Unit and other accessories are available as options.

"List of Options" (page 16)

Package Contents

Static Elimination Head (SJ-M021)

Controller Unit (SJ-M201)

SJ-M021

Mounting Fixture x 1

Instruction Manual

WARNING labels (Japanese, German, French, Italian and Chinese (Simplified)) *

* Use as necessary.

Earth lead

Options

Replacement Electrode Unit for SJ-M021 (OP-51607)

Replacement Electrode Unit for SJ-M021G (OP-75351)

PFA tube 0.5 m (OP-75350)

Discharge Prevention Cap (OP-75354)

AC Adapter SJ-U2

*For details on the AC cable, contact your local Keyence office.

1-3 Names and Functions of Parts

This section describes the names and functions of parts in the SJ-M Series.

Static Elimination Head

SJ-M021(G)

(4)

 

(3)

(1)

(5)

(2)

(1) Electrode probe

Ion charge is emitted from the tip of this probe.

(2) Nozzle mounting fixture

Used for installing a special nozzle.

(3) Allowable mounting fixture range

The unit is fixed in place in this area with the mounting fixture (provided).

(4) High-voltage cable

Ambient operating temperature: 0 to +80°C Minimum bending radius 50 mm

(5) Air Input Unit

Supplies clean, dry air.

1-3 Names and Functions of Parts

Controller Unit (operation/display section)

(1) Ion balance

SJ-M201

 

 

 

indicator

(5) Alarm indicator

(2) Ion level

 

 

indicator

 

 

 

 

(6) Ion level alarm indicator

(3) Ion monitor

 

 

 

 

(7) Condition alarm indicator

 

 

(8)

key

(4)

keys

 

 

 

Enlarged view of display section

Terminal plate cover

 

 

 

(1) Ion balance indicator

Lights when the charged level of the target object is

 

 

displayed.

 

(2) Ion level indicator

Lights when the ion emission level is being displayed.

(3) Ion monitor

Indicates the charged level of the target object.

 

 

Also, indicates the ion emission level.

 

(4)

keys

Used for adjusting the ion balance and for selecting setting

 

 

items.

 

(5) Alarm indicator

Lights when an alarm occurs.

 

(6) Ion level alarm indicator

Lights when the ion emission level has fallen below the set

 

 

value due to dirt or wear of the electrode probe.

(7) Condition alarm indicator

Lights when the charged level of the target object is high

 

 

and static cannot be completely eliminated.

(8)

key

Used for determining setting items and for switching the

 

 

display.

 

3

KEYENCE SJ-M201 User Manual

 

 

 

 

1-3 Names and Functions of Parts

Controller Unit (I/O terminal section)

 

 

(1)

(2)

(3)

 

(4)

(5)

(6)

(7)

Number

Name

 

 

Function

(1)

Condition alarm output

 

Outputs when static elimination performance is influenced by excessive

terminal

 

charge. (N.O.)

 

 

(2)

Ion level alarm output

 

Outputs when the ion emission level drops. (N.O.)

terminal

 

 

 

 

 

(3)

Static elimination stop input

Static elimination can be turned ON/OFF by shorting this terminal with

terminal

 

(6).

 

 

 

 

(4)

Ground terminal

 

Be sure to connect a Class D earth (maximum resistance of 100 Ohms).

(5)

DC power terminal

 

24 VDC ±10%

(6)

0V terminal

 

0V for power and 0V for I/O

(7)

Alarm output terminal

 

Outputs when an alarm occurs. (N.C.)

Input circuit diagram

[ (3) (static elimination stop input)]

+24V

Input a no-voltage contact (relay, etc.)

or NPN open collector across INPUT and 0V.

3kΩ

INPUT( (3) )

0V( (6) )

Output circuit diagram

Open collector output

[ (2) (ion level alarm output), (1) (condition alarm output), (7) (alarm output)]

OUT DC40V 100mA

0V( (6) )

2-1 Before Installation

This section describes the static elimination performance of the SJ-M201 Series.

Before you install the SJ-M201 Series, fully calculate the distance between the Static Elimination Head up to the target object and the time required for static elimination.

About Static Elimination Performance

The following shows a typical example where static is eliminated from an aluminum plate (20 pF) 150 x 150 mm square, charged to +1000 V, by the SJ-M201 Series.

Static elimination time

The following graphs show typical examples of the relationship between static elimination time and static charged voltage.

Measurement condition: Applied voltage +1000 V

150 mm x 150 mm plate monitor (20 pF) used Installation distance 300 mm

Air purge pressure 0.5 MPa Cable length 2 m

SJ-M021

 

 

 

 

 

 

 

SJ-M021G

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

900

 

 

 

 

 

 

 

 

900

 

 

 

 

 

 

 

 

 

(V)

800

 

 

 

 

 

 

 

(V)

800

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

level

600

 

 

 

 

 

 

 

level

600

 

 

 

 

 

 

 

 

 

Charged

500

 

 

 

 

 

 

 

Charged

500

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

0 0

0.2

 

0.4

0.6

 

0.8

1

 

0 0

 

0.1

0.2

 

0.3

0.4

 

0.5

0.6

 

 

 

 

Time (secs)

 

 

 

 

 

 

 

 

Time (secs)

 

 

 

SJ-M021+SJ-MS2

 

 

 

 

 

 

SJ-M021+SJ-MS1

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

900

 

 

 

 

 

 

 

 

900

 

 

 

 

 

 

 

 

 

(V)

800

 

 

 

 

 

 

 

(V)

800

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

level

 

 

 

 

 

 

 

level

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

Charged

500

 

 

 

 

 

 

 

Charged

500

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

0

0.2

0.4

0.6

0.8

1

1.2

1.4

 

0

1

2

3

4

5

6

7

8

9

 

0

 

0

 

 

 

 

Time (secs)

 

 

 

 

 

 

 

 

Time (secs)

 

 

 

2-1 Before Installation

SJ-M021+SJ-MS3 (500 mm)

 

1000

 

 

 

 

 

 

 

 

900

 

 

 

 

 

 

 

(V)

800

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

level

600

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

Charged

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

 

0

 

 

 

 

Time (secs)

 

 

 

SJ-M021+SJ-ML

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

900

 

 

 

 

 

 

 

(V)

800

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

level

600

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

Charged

 

 

 

 

 

 

 

400

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

0

0.2

0.4

0.6

0.8

1

1.2

1.4

 

0

Time (secs)

SJ-M021+SJ-ML1

 

1

 

0.9

(V)

0.8

0.7

level

0.6

 

Charged

0.5

0.4

0.3

0.2

0.1

0

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

 

 

 

 

Time (secs)

 

 

 

 

SJ-M021+SJ-ML4 (500 mm)

 

1

 

0.9

(V)

0.8

0.7

level

0.6

Charged

0.5

0.4

0.3

0.2

0.1

0

0

1

2

3

4

5

6

7

8

9

10

 

 

 

 

Time (secs)

 

 

 

 

SJ-M021+SJ-MS4 (500 mm)

 

1000

 

900

(V)

800

700

level

600

Charged

500

400

300

200

100

0

0

1

2

3

4

5

6

7

8

9

10

11 12

Time (secs)

SJ-M021+SJ-ML2

 

1

 

0.9

(V)

0.8

0.7

level

0.6

Charged

0.5

0.4

0.3

0.2

0.1

0

0

0.5

1

1.5

2

 

 

Time (secs)

 

 

SJ-M021+SJ-ML3 (500 mm)

 

1

 

0.9

(V)

0.8

0.7

level

0.6

Charged

0.5

0.4

0.3

0.2

0.1

0

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

 

 

 

 

Time (secs)

 

 

 

 

2-1 Before Installation

Static elimination area

The following graphs show the relationship between the time required for eliminating static from a target object charged between +1000 and +100 V and the distance from the charged object to the Static Elimination Head.

Model No. SJ-M021

 

 

 

 

 

 

 

 

 

 

 

Air flow rate 20 Nl/min

 

Air flow rate 60 Nl/min

 

Air flow rate 250 Nl/min

(pressure 0.01 MPa)

 

(pressure 0.05 MPa)

 

(pressure 0.5 MPa)

 

 

 

 

 

 

1000 mm

 

 

 

5sec

1500 mm

 

 

 

2sec

 

 

 

 

 

900

 

 

 

 

1350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

700

 

 

 

 

1050

 

 

 

1sec

600 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10sec

600

 

2sec

 

900

 

 

 

 

500

 

 

 

500

 

 

750

 

0.5sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

600

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

5sec

 

300

 

1sec

 

450

 

 

 

 

200

 

2sec

 

200

 

0.5sec

 

300

 

 

 

 

100

 

1sec

 

100

 

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

0.5sec

mm

0

 

 

 

m

0

 

 

 

mm

200 150 100

50

0

50 100 150 200

200 150 100

50

0

50

100 150 200

200 150 100

50

0

50

100 150 200

Model No. SJ-M021G

 

 

 

 

 

 

 

 

 

 

 

Air flow rate 20 Nl/min

 

Air flow rate 60 Nl/min

 

Air flow rate 200 Nl/min

(pressure 0.02 MPa)

 

(pressure 0.12 MPa)

 

(pressure 0.5 MPa)

 

 

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

1.5sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

1sec

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

1000 mm

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

3sec

000

 

 

 

 

 

 

 

 

 

900

 

 

 

900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

 

2sec

 

800

 

0.5sec

 

600mm

 

 

 

 

700

 

 

 

 

700

 

 

 

 

 

 

 

10sec

600

 

 

 

 

600

 

 

 

 

500

 

 

 

500

 

 

 

 

500

 

 

 

 

 

 

5sec

 

 

1sec

 

 

 

 

 

400

 

 

 

400

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

300

 

 

 

 

300

 

 

 

 

200

 

 

2sec

 

200

 

 

 

 

200

 

 

 

 

 

1sec

 

 

 

 

 

 

 

 

 

100

 

 

100

 

0.5sec

 

100

 

 

 

 

 

0.5sec

 

 

 

 

 

 

 

0

 

mm

0

 

 

 

mm

0

 

 

 

mm

 

 

 

 

 

 

 

 

 

200 150 100

50

0

50 100 150 200

200 150 100

50

0

50 100 150 200

-200 -150 -100 -50

0

50 100 150 200

4

 

 

 

 

 

 

 

 

 

 

2-1

 

Before Installation

 

 

 

 

 

 

2-1

Before Installation

Model No. SJ-M021+SJ-MS1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air flow rate 20 Nl/min

Air flow rate 60 Nl/min

Air flow rate 160 Nl/min

Model No. SJ-M021+SJ-ML

 

 

 

 

 

(pressure 0.03 MPa)

(pressure 0.16 MPa)

(pressure 0.5 MPa)

 

 

 

 

 

Air flow rate 20 Nl/min

Air flow rate 60 Nl/min

Air flow rate 250 Nl/min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

(pressure 0.02 MPa)

(pressure 0.1 MPa)

(pressure 0.5 MPa)

 

 

 

 

 

1000

 

 

 

10sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8sec

 

 

 

 

 

 

 

 

 

 

1500

 

 

 

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

 

1400

 

 

 

 

 

 

 

 

 

 

1500 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

1300

 

 

 

 

 

 

 

 

 

 

1400

 

 

8sec

 

 

 

 

 

 

 

600mm

 

 

 

600

 

 

 

 

1300

 

 

 

 

 

 

 

 

1200

 

 

 

10sec

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

5sec

1100

 

 

7sec

 

 

 

 

 

 

1100

2sec

500

 

 

8sec

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

900

 

 

5sec

 

 

 

 

mm

 

1000

 

400

 

 

 

 

 

 

 

 

800

 

 

 

 

 

1000

 

 

300

 

 

 

 

300

 

 

 

 

700

 

 

 

 

 

 

 

10sec

900

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

900

 

 

 

 

 

 

 

200

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

 

3sec

400

 

 

3sec

 

 

 

800

 

 

800

 

 

 

 

5sec

100

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

200

 

2sec

 

 

 

700

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

mm

0

 

 

 

mm

100

 

 

mm

 

mm

 

 

 

 

 

 

 

 

 

 

 

0

 

 

600

 

600

 

 

600

 

200 150 100

50

0

50 100 150 200

200 150 100

50

0

50 100 150 200

400 350 300 250 200 150 100

50

0

50 100150200250300350400

 

 

 

5sec

 

 

500

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20sec

500

 

 

1sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

400

 

 

400

 

Model No. SJ-M021+SJ-MS2

 

 

 

 

 

 

 

 

 

300

 

15sec

300

 

2sec

300

 

Air flow rate 20 Nl/min

Air flow rate 60 Nl/min

Air flow rate 250 Nl/min

200

 

10sec

200

 

200

 

 

 

 

0.5sec

(pressure 0.02 MPa)

(pressure 0.1 MPa)

(pressure 0.5 MPa)

100

 

3sec

100

 

1sec

100

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

0

 

mm

0

 

mm

0

mm

 

 

 

 

 

1000

 

 

 

mm

 

 

 

 

 

0 50 100 150 200

0 50 100 150 200

 

 

 

 

 

 

 

 

 

 

 

 

200 150 100 50

0 50 100 150 200

200 150 100 50

200 150 100 50

 

 

 

 

 

900

 

 

10sec

1500

 

 

3sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800

 

 

 

8sec

1300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

700

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

1100

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

600

 

 

 

5sec

1000

 

 

2sec

 

 

 

 

 

 

 

 

 

 

20sec

 

 

 

900

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

500

 

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

400

 

 

 

 

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

 

 

 

 

 

 

300

 

 

10sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

500

 

 

1sec

 

 

 

 

 

 

 

 

200

 

 

8sec

 

 

 

 

 

400

 

 

 

 

 

 

 

 

 

 

 

 

200

 

 

 

2sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

100

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

mm

0

 

 

 

mm

100

 

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 150 100

50

0

50 100 150 200

200 150 100

50

0

50 100 150 200

300 250 200 150 100

50

0

50 100150200250300

 

 

 

 

 

 

 

 

SJ-M021+SJ-MS2/ML2

Static elimination area

280mm

100mm

-50mm

14-50mm

100mm 500mm

2-1 Before Installation 2-1 Before Installation

Model No. SJ-M021+SJ-MS3/ML3 (500 mm)

 

 

 

Appropriate static elimination method

 

Air flow rate 140 Nl/min

Air flow rate 230 Nl/min

Pay attention to the following points to ensure that static elimination is performed appropriately.

(pressure 0.3 MPa)

 

(pressure 0.5 MPa)

Static elimination cannot be performed accurately at locations where the target object is

 

 

 

 

mm

 

 

 

touching a metallic body (earthed body).

 

 

 

 

 

1500

 

 

8sec

Eliminate static from the target object at locations where it is not directly touching a metallic body

 

 

 

 

1400

 

 

7sec

 

 

 

 

 

 

(earthed body).

 

 

 

 

 

 

1300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

1000mm

 

 

 

1100

 

 

 

 

 

 

 

 

7sec

1000

 

 

5sec

 

 

 

 

 

 

 

 

 

 

 

 

900

 

 

 

900

 

 

 

 

 

 

800

 

 

 

800

 

 

 

 

 

Board

700

 

5sec

700

 

 

 

 

Board

 

600

 

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

500

 

 

 

 

 

 

400

 

 

 

400

 

 

3sec

 

Metal

Insulating mat

300

 

 

 

300

 

 

 

 

 

 

200

 

3sec

200

 

 

2sec

Static will be eliminated from only the surface of the insulated body (board, etc.) that is facing

100

 

100

 

 

the Static Elimination Head.

 

 

 

mm

 

 

 

 

0

 

 

0

 

 

mm

When eliminating static from both sides of a target object, install two SJ-M Series as one SJ-M Series

50

0

50 100 150 200

50

0

50 100 150 200

200 150 100

200 150 100

must be installed on either side of the target object.

 

 

 

 

 

 

 

 

 

 

Model No. SJ-M021+SJ-MS4/ML4 (500 mm)

 

 

 

NOTICE

Install the Static Elimination Head so that it can be easily accessed, for

 

 

 

example, for replacement of parts and cleaning.

 

Air flow rate 145 Nl/min

Air flow rate 240 Nl/min

 

 

 

 

(pressure 0.3 MPa)

(pressure 0.5 MPa)

 

 

 

 

mm

 

 

 

 

 

 

 

1500

 

 

15sec

 

 

 

 

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

1300

 

 

 

 

 

 

 

1200

 

 

10sec

1000mm

 

 

 

1100

 

 

 

 

 

13sec

1000

 

 

 

900

 

 

900

 

 

 

 

 

 

 

 

 

800

 

 

 

800

 

 

 

700

 

10sec

700

 

 

 

600

 

 

 

600

 

 

 

500

 

 

 

500

 

 

5sec

400

 

 

 

400

 

 

 

300

 

 

 

300

 

 

 

200

 

 

7sec

200

 

 

 

 

 

 

 

 

 

100

 

 

 

100

 

 

 

0

50

0

mm

0

50

0

mm

200 150 100

50 100 150 200

200 150 100

50 100 150 200

Installation Precautions

Installation site

NOTICE

5

Install the tip of the SJ-M021(G) paying attention to the following point.

Install the Static Elimination Head away from the wall or surrounding objects.

SJ-M021(G)

10 mm or more

10 mm or more

 

 

 

 

 

 

 

 

10 mm

 

 

 

10 mm

or more

 

 

 

 

 

 

or more

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Requires 10 mm or more away

 

 

 

 

 

 

 

23mm*

 

 

from the air outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The section marked by "*" must not touch the conductor (earthed body). The adapter nozzle must not touch the conductor (earthed body).

Protect the area around the tip of the Static Elimination Head with silicon, fluoro-resin or other highly ozone-resistant resin. Ozone that is generated may cause the metal or resin on the SJ-M021(G) to rust, corrode or deteriorate.

Loading...