Kenmore Elite 79033269600, 79033263600, 79033263601, 79033243601, 79033249600 Installation Guide

...
0 (0)
iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death. FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
0
Do not try to light any appliance.
0
Do not touch any electrical switch; do not use any phone in your building.
0
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
0
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
30" Min.
Gas Cooktop Dimensions
21/2"
(76.2 cm) _la
Gas Cooktop (6.4 cm) Cutout Dimensions , tt
Figure 1
i_!_iiii__i_i_i_!iii!_i_i_¸i_i_i!_!_!_i_i_i_i_i_i_!ii_!!!!!_i_i_i_i_i_i_i_i_i_i_i_i_i_!_!_!_!_!!!!_ii_
30"GasCooktop 30 (76.2) 213A(55.2) 4_A(10.8) 27(68.6) 19 (48.3) 36"GasCooktop 36 (91.4) 213A(55.2) 4_A(10.8) 33_/4(84.5) 19(48.3)
u
30"GasCooktop 27Y4(69.2) 273A(70.5) 19_/8(48.6) 19s/8(49.8) 8 (20.3) 36"GasCooktop 33_/4(84.5) 333A(85.7) 19_/8(48.6) 19s/8(49.8) 8 (20.3)
All dimensions are stated in inches and (cm). Dimension H includes a 5" (12.7 cm) space underneath the cooktop for connection to gas supply line. NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
Printed in United States
318201470 (0606) Rev.A
Espar_ol- p_qginas 10-18
Wiring Diagram 19-20
English - pages 1-9
Important Notes to the Installer
I. Read all instructions contained in these installation
instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leavethese instructions with the consumer.
5. Note: For operation at 2000 ft. elevations above see level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.
Important Note to the Consumer
Keep these instructions with your Useand Care Guide for future reference.
IMPORTANT SAFETY
INSTRUCTIONS
Installation of this cooktop must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 in the United States, or in Canada, with the Canadian Fuel Gas Code, CAN/CGA
B149 and CAN/CGA B149.2.
When installed in a manufactured (mobile) home
installation must conform with the Manufactured Home Construction and Safety Standard, title 24 CFR,part
3280 [Formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD (part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installation, ANSI/NCSBCS A225.1 or with local codes where applicable.
This cooktop has been design certified by CSA International. As with any appliance using gas and generating heat, there are certain safety precautions you
should follow. You will find them in the Useand Care Guide, read it carefully.
Be sure your cooktop is instaJJed and grounded properly by a qualified installer or service
technician. This cooktop must be electrically grounded in
accordance with local codes or, in their absence, with the National ElectricaJ Code ANSI/NFPA No.
70--latest edition in the United States, or in Canada, with the Canadian Electrical Code, CSA
C22.1 Part 1.
The burners can be lit manually during an electrical power outage. To light a burner, hold a lit match to the burner head, then slowly turn the
Surface Control knob to MTE. Use caution when lighting burners manually.
Do not store items of interest to children in cabinets above the cooktop. Children could be
seriously burned climbing on the cooktop to reach items.
To eliminate the need to reach over the surface burners, cabinet storage space above the burners
should be avoided.
Adjust surface burner flame size so it does not extend beyond the edge of the cooking utensil
Excessive flame is hazardous.
Never use your cooktop for warming or heating the room. Prolonged use of the cooktop without adequate ventilation can be hazardous.
Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance. Explosions or fires could result.
The electrical power to the cooktop
must be shut off while gas line connections are being made. FaiJure to do so could resuJt in serious injury or death.
13" (33 cm)
Max. Depth For Cabinet
Installed Above Cooktop.
B
18" Min,
(45.7 cm)
k
I
11/2"(3.8 cm)Minimum Distance Between RearEdge of Cutout
and Nearest Combustible Surface
Above Countertop,
Clearance
30" (76.2 cm) Min, Clearance
Between the
Top of the
Cooking Platform and
Unprotected
Wood or Metal
Cabinet
24" cm)
\
_To eliminate the risk of burns or fire from reaching over heated
surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the
cabinets.
Drawers Cannot Be Used with This Cooktop Since Burner Box Extends
3s/32'' (8.02 cm) Below Surface of Countertop.
30'_Cooktop 30'_(76.2 cm) 7'_(17.8 cm) 36'_Cooktop 36'_(91.4 cm) 7'_(17.8 cm)
Figure 2 - CABINET DESIGN
7"(17.8 cm) 7"(17.8 cm)
Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Under the Counter
I_---- 18" (45.7 cm) Max.-----_
Wall
Manifold Pi
Flexible Connector
Oven Cabinet
Cabinet sides or
filler panel
5" ,(16.5 cm)
Flare (12.7cm) Min. Union
_J Flare _j Union
J
61_2"
120V/60Hz
Grounded
Outlet
Pressure Regulator
Manual Shutoff Valve
(To be accessible for shut-off valve opera-
tion)
4" (10.2 cm)
Right Side of
Cabinet
Typical Under Counter Installation of an Electric Built-in
Oven with a Cooktop Mounted Above
Side filler panels are necessary to isolate the unit from adjoining
cabinets. Panelheight should allow
for installation of approved cooktop
models. See "Typical Gas Cooktop Installation Over an ElectricBuilt-in
Oven Installed Under the Counter" on previous page.
32" Min.** (81.3 cm)
36"
(91.4 cm)
All mounting hardware must be used to secure
the built-in oven to the cabinets. Refer to the built-in oven installa- tion instructions.
208/240 Volt grounded junction
box for built-in
Junction box must
be located approx. 3" to the left of
the built-in oven cutout,
This cooktop may be installed over
certain built-in elec- tric oven models.
* If no cooktop is installed directly
over the oven unit, 5" (12.7 cm)
maximum is allowed.
** 32" (81.3 cm) min. from top of
cabinet to top of runners must be
maintained.
Use 3/4" (1.9 cm) plywood, installed on two runners, flush with toe plate. Must be capable of supporting 150 Ibs.
Cut an opening in wood base minimum 9" (22.9 cm) x 9" (22.9 cm), 2" (5.1 cm) from left side filler panel, to route armoured cable to junction box.
4 1/2" (11.4 cm)
Max.*
CUTOUT DIMENSIONS (inches)
OVEN SIZE E F G
Min. Max, Min. Max.
30" 27¼" 28s/8 '' 281/2" 29" 231/2"
(76.2 cm) (69.2 cm) - (72.7 cm) (72.4cm) - (73.7 cm) (59.7 cm)
27" 27¼" 28s/8 '' 247/8 '' 25¼" 231/2"
(68.6cm) (69.2cm) - (72.7cm) (63.1cm) (64.1cm) (59.7cm)
Wall Outlet Location
12"_
To clamp down, insert an angle bracket into the slot on each side of the unit as shown.Run thumb screw up through the bracket, up against the bottom of the counter. Tighten until the unit draws down and issecure.
Provide an Adequate Gas Supply
This cooktop is designed to operate on natural gas at 4" of manifold pressure only.
10"
A pressure regulator is connected in series with the manifold on the cooktop and must remain in series with the supply line.
Recommended area for
12OV grounded outlet
on rear wall.
_.._F UEN_T 22"
: NOTE: If an outlet I is not available,
have one installed by
i a qualified technician. _,
OF UNIT
Figure 3
Cooktop Installation
1. Visually inspect the cooktop for damage.
2. Set the cooktop into the countertop cutout.
NOTE: Do not use caulking compound; cooktop should be removable for service when needed.
Clamp Down Information
Once the cooktop is installed in the counter opening, you must clamp the unit down as shown.
Countertop
Cooktop _ t
, _ _ ,
For proper operation, the maximum inlet pressure to the regulator must be no more than 14" of water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at least 1" (or 2.5 kPa) greater than the regulator manifold pressure setting. The regulator is set for 4" of manifold pressure, the inlet pressure must be at least 5".
The gas supply line to the range should be I/2" or 3/4" pipe.
LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/ Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LPgas is supplied with your cooktop. The kit is marked "FOR LP/PROPANEGAS CONVERSION".
The conversion must be performed by a qualified service technician in accordance with the kit instructions and all
local codes and requirements. Failure to follow instructions could result in serious injury or property
damage. The qualified agency performing this work assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and property damage.
Angle ......__Ll_
Bracket_
Figure 4
_ Thumb
Screw
Loading...
+ 14 hidden pages