Kathrein VGO 939-1G, VGF 9030-9040, VGP 9033-1G-9041, VOS 952-1G-953-1G, VGF 939-1G User Manual

0 (0)

Compact amplifiers

VGP 9033-1G/9041 VGF 9030/9040

VGO 939-1G/VGF 939-1G VOS 952-1G/953-1G

Antennen · Electronic

CONTENTS

VGP 9033-1G/9041-VGF 9030/9040

Product description

Page 3

Details, Block diagram, Accessories

Page 4-5

Technical Data

Page 6

VGO 939-1G/VGF 939-1G

Product description

Page 7

Details, Block diagram, Accessories

Page 8-9

Technical data

Page 10

VOS 952-1G/953-1G

Product description

Page 11

Details, Block diagram, Accessories

Page 12-13

Technical data

Page 14-15

Accessories

 

 

 

 

 

 

TVM 850/H, TVM 1000

Page 16

 

 

HTE 10

Page 17

 

 

Splitters, Taps, Equalisers

Page 18-19

 

 

Connectors

Page 20

 

 

 

 

 

 

 

 

 

 

 

 

 

VGP 9033-1G/9041

 

VGF 9030/9040

DESCRIPTION

VGP 9033-1G/9041 – VGF 9030/9040

Modern, monitorable compact amplifiers for interactive HFC networks

Innovative operational concept: Using electronic tuning elements, set using HTE 10 hand-held unit (fewer plug-in cards and attenuation pads required, repeatable device settings)

Integrated frequency-agile 2-pilot control in

VGP 9033-1G/9041enables quick commissioning:

-Automatic levelling in the forward path, thus no need for time-consuming manual levelling

-Automatic presetting of the return path is possible

Remote configuration of all setting parameters via monitoring system (can be activated/deactivated)

High gain (up to 40 dB), variable in interstage position

Latest GaAs-MMIC technology

Very high output levels at lowest intermodulation products, even for interstage operation

Loop-through input (only for VGP 9033-1G/9041) and output splitter can be configured

De-emphasis (inverse-equalisation) insert position

Remote feeding: 7 A per input/output, local feeding: 10 A

Insert position for monitoring transponder (HMS/DOCSIS)

Test sockets on input/output and in return path amplifier

Integrated return path amplifier, settable gain

Ingress Control Switch

Aluminium die-cast housing with PG 11 connections

The compact amplifiers with electronic tuning elements –

VGP 9033-1G/9041 and VGF 9030/9040

With the VGP 9033-1G/9041 and VGF 9030/9040 Kathrein offers a latest-generation compact amplifier series. A wide range of settings, electronic operation and excellent technical data – at an unbeatable price/performance ratio.

"Plug-and-Play" redefined

Electronic setting of all important parameters, automatic levelling (only for VGP 9033-1G/9041) as well as remote configuration via HMS or DOCSIS monitoring ensure the shortest start-up and maintenance times. The copy function enables one to copy all settings and transfer them to another device at the press of a button.

The absence of plug-in cards for gain and slope not only accelerates start-up, but also simplifies logistics and saves warehousing costs.

Another advantage during modifications:

new values are taken over without any interruptions. Multimedia services remain undisturbed.

Start-up without a measuring instrument

– it doesn't get any easier than this

Due to automatic levelling, the compact amplifiers VGP 9033/9041 can be put into operation

with just a few steps:

-Simply enter the desired output level for the lower and upper pilot frequency and start levelling

-After a few seconds, the device automatically sets the desired values, whereby optimal technical data are continuously reached.

Manual vernier adjustment is still possible at any time.

-Subsequently, automatic presetting can also be effected in the return path.

-For the next devices, levelling runs even more quickly. The copy function enables desired settings to be automatically incorporated.

Kathrein VGO 939-1G, VGF 9030-9040, VGP 9033-1G-9041, VOS 952-1G-953-1G, VGF 939-1G User Manual

VGP 9033-1G/9041 VGF 9030/9040

Insert position for monitoring transponder

(not included in delivery scope)

Insert position "Forward 1" e.g. for additional C-line pre-emphasis

F-type test socket internal (-20 dB)

Insert position "Forward 2"

Connection socket for hand-held unit HTE 10

Image: VGP 9033-1G/9041

 

 

 

F-type

 

 

 

 

 

 

 

 

 

test socket

 

 

 

 

 

 

 

 

 

 

internal

 

 

 

 

 

(-20 dB)

 

 

F-type broadband input

 

 

 

 

 

 

 

 

for the return path with

 

 

Input insert position

protective cap (-10 dB)

 

 

 

 

 

 

 

 

Output insert position

DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS

Image: VGP 9033-1G/9041

Delivery status

Note: The input and output plug-in positions must each be equipped with a EBC/EAC xx for operation. The other plug-in positions are already equipped with null cards

Input and output cable fittings not included in the delivery scope (see page 20)

Please note that the VGF 9030/9040 does not include remote-feed fuses in its delivery scope (see page 20)

Accessories

EBC 01E-1G (Order no. 24510121): Null card input

EBC 00-1G (Order no. 24510119): Null card output, for operation with one output

EBC 90-1G (Order no. 24510113): Splitter (2 outputs symmetrical)

EAC 93-1G (Order no. 24510115): Tap (3/6 dB)

EAC 90-1G (Order no. 24510116): Tap (1.5/10 dB)

EAC 94-1G (Order no. 24510114): Tap (0.8/20 dB)

ERC 22 (Order no. 24510085):

C-line pre-emphasis equaliser for VGP 9041/VGF 9040

• ERZ 630 (Order no. 24510108): Equaliser 630 MHz

• ERS 800 (Order no. 24510109): System equaliser 862 MHz

• ERD 810 (Order no. 24510110): De-emphasis equaliser switchable, 862 MHz

• ERD 813 (Order no. 24510117): De-emphasis equaliser

ERD 814 (Order no. 24510120): Attenuation pad

TVM 850/H (Order no. 26210077):

Monitoring transponder HMS (5-24 MHz), frequency-agile

• TVM 1000 (Order no. 26210086): Monitoring transponder DOCSIS

• FUN 15 (Order no. 25010017):

FUN remote-feed fuse 15A/125 VDC

• HTE 10 (Order no. 25010005): Hand-held unit For details see pages 16-20

VGP 9033-1G/9041

 

 

 

 

 

VGF 9030/9040

 

 

 

 

DATA

Technical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

VGF 9030

 

VGF 9040

 

 

VGP 9033-1G

 

VGP 9041

 

 

 

 

 

 

 

 

 

 

Order no.

 

24410108

 

24410109

 

 

24410103

 

24410054

 

 

 

 

 

 

 

 

 

 

FORWARD PATH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency range

MHz

85-862

 

85-862

 

85-1000

 

85-862

 

 

 

 

 

 

 

 

 

 

Gain (at 1000 MHz)

dB

33

 

40

 

33

 

40

 

 

 

 

 

 

 

 

 

Return loss

dB

 

 

19-1.5 dB/oct.

 

 

 

 

 

 

 

 

 

 

 

Frequency response (85-1000 MHz at 25 °C)

dB

 

 

 

± 0.5

 

 

 

 

 

 

 

 

 

 

 

 

Max. output level according to CENELEC 1) - CTB > 60 dB

dBµV

 

 

 

114

 

 

 

 

 

 

 

 

 

 

 

 

Max. output level to CENELEC 1) - CSO > 60 dB

dBµV

 

 

 

116

 

 

Attenuation range, electronically settable in 0.5 dB steps 5)

dB

0-16

 

 

0-15

 

0-16

Slope range, electronically settable in 0.5 dB steps 5)

dB

0-20

 

0-15

 

0-20

Interstage attenuation, settable in 1 dB steps

 

-

 

 

0-5

 

-

 

 

 

 

 

 

 

 

 

 

Interstage pre-emphasis, electronically settable in 2.5 dB steps

dB

2-9

 

 

2,5-10

 

2-9

 

 

 

 

 

 

 

 

 

 

Noise figure at minimum pre-emphasis

dB

6

 

 

6.5

 

6

 

 

 

 

 

 

 

 

 

 

Adjustment range, sloped at 85 MHz

dB

-

 

 

± 2

 

 

 

 

 

 

 

 

 

 

 

Adjustment range, parallel

dB

-

 

 

± 3

 

 

 

 

 

 

 

 

 

 

 

Frequency range lower pilot Pu ²)

MHz

85-230

 

 

85-230

 

82.5-230

 

 

 

 

 

 

 

 

 

 

Frequency range upper pilot Po ²)

MHz

570-870

 

 

570-870 5)

 

Pilot level (PAL/CW/QAM)

dBµV

 

 

 

83-112

 

 

 

 

 

 

 

 

 

 

 

 

Hum modulation ratio at 7 A

dB

70

 

 

> 67

 

70

 

 

 

 

 

 

 

 

 

 

RETURN PATH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency range

MHz

 

 

 

5-65

 

 

 

 

 

 

 

 

 

 

 

 

Gain

dB

30

 

 

28

 

30

 

 

 

 

 

 

 

 

 

 

Frequency response at 25 °C

dB

± 0.5

 

 

± 0.3

 

± 0.5

 

 

 

 

 

 

 

 

 

 

Input level density (CINR = 50 dB), at 28 dB gain 6)

dBµV/Hz

 

 

 

-9

 

 

Dynamic range: CINR > 50 dB, 5-65 MHz, at 28 dB gain 6)

dB

 

 

 

21

 

 

Dynamic range: CINR > 50 dB, 5-65 MHz, at 18 dB gain 7)

dB

 

 

 

26

 

 

Noise figure

dB

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

Attenuation, switchable in 1 dB steps

dB

 

 

 

0-30

 

 

 

 

 

 

 

 

 

 

 

 

Slope, switchable in 7 steps

dB

 

 

 

1-8

 

 

 

 

 

 

 

 

 

 

 

 

ICS switch (attenuation switchable over EMS or

dB

 

 

 

0/6/> 45

 

 

HTE 10 hand-held unit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hum modulation ratio at 7 A/> 15 MHz

dB

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage supply

V AC

 

 

 

30-72

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

W

21

 

 

23

 

 

 

 

 

 

 

 

 

 

 

Max. remote feed current per connection

A

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. remote feed current in local feeding (power passing)

A

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

RF connections

 

 

 

 

PG 11

 

 

 

 

 

 

 

 

 

 

 

Housing protection category

 

IP 54

 

 

 

IP 67

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature range

°C

 

 

 

-20 to +55

 

 

 

 

 

 

 

 

 

 

Screening factor

 

 

 

Conforms to CENELEC EN 50083-2

 

 

 

 

 

 

 

 

 

 

Overvoltage protection acc. to IEC 60-2

 

 

 

2 kV (1.2/50 µs)

 

 

 

 

 

 

 

 

 

 

Dimensions (W x H x D)

mm

 

 

240 × 95 × 240 3)

 

 

NETWORK MANAGEMENT (optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operational voltage; current; temperature; electronic tuning elements; pilot setting and

Monitorable/settable parameters

 

alarm; automatic levelling of forward path; automatic presetting of return path; return

 

 

 

path gain; ICS switch; remote inventory data

 

 

 

 

 

 

 

 

 

 

 

1) 9 dB slope 2) Set using HTE 10 hand-held unit 3) Width incl. hinges: 267 mm 4) As of device version Bxx from 570-870 MHz 5) For VGP 9033-1G in 1 dB steps

 

6) For VGF 90xx at 30 dB gain

7) For VGF 90xx at 20 dB gain

 

VGO 939-1G/

 

VGF 939-1G

DESCRIPTION

VGO 939-1G/VGF 939-1G

Latest GaAs-MMIC technology

Innovative operational concept:

-Settings via slide switches

-Device settings can be reproduced exactly

-Fewer plug-in cards and variable attenuators needed

Integrated diplexers allow optimised data

Very high output level at lowest intermodulation products (also for interstage attenuation)

Pluggable loop-through output

One or two output(s) configurable

Built-in active return path with various setting possibilities

Return path can also be operated passively

15 MHz high pass can be activated in the return path

Ingress Control Switch (ICS)

Monitorable with HMS or DOCSIS transponder (option)

Insert position for additional functions in the forward path (e.g. de-emphasis)

Bi-directional test socket on the amplifier input

Directional coupler test socket on amplifier output and in return path

Test signals can be coupled in for the return path

LED as function indicator

Highly efficient switched-mode power supply unit

Advanced remote power concept in the VGF 939-1G:

-Newly developed remote feed coils

-Remote feed current: Max. 7 A per connection, local insertion max. 10 A totally

-Remote feeding possibilities: By choice via all RF connections or local connector (power passing)

Surge absorber on all RF connections and in switched-mode power supply unit

Power management: Unused amplifier stage switch-off for reduced power consumption

Die-cast housing with PG 11 connectors

Easy connection of large cable fittings due to extended thread distance

Outdoor operation possible, housing protection class: IP 54

Test sockets: F-type connectors (internal)

The compact amplifier with slide switches –

VGO 939-1G/VGF 939-1G

In addition to the devices with electronic setting, Kathrein offers yet another highly innovative compact amplifier platform. This particularly economical series requires no equaliser cards

or attenuation pads. All adjustments can be easily carried out using slide switches.

Simple, yet effective

The required attenuation and slope values are set with a combination of several slide switches. The advantages are obvious. Besides saving plug-in cards, this allows exact reproduction of setting values without requiring a measuring instrument.

Replacement of the device, for example, is thus much easier.

When slide switches are shifted, a virtually uninterrupted signal flow is guaranteed – multimedia services remain undisturbed.

Maximum reliability

The implemented slide switches fulfil the highest demands regarding reliability and endurance. Dual gold-plated contact reeds, increased contact pressure and a separate catch spring ensure ultimate reliability of the switches, which have been proven and tested 100,000 times.