DEMO MODE USER’S MANUAL

Premium High Definition Touch Screen Communicating Control

Models: S1-TTSCC01

POWER-UP SEQUENCE

The communicating control will load the following screens upon initial power up:

Screen 1 – Set date and time by selecting a field and using the up/down arrows provided. See figure at right.

Screen 2 – The control will display the Software Revision.

Screen 3 – The control “listens” for network traffic for a random interval between 1 – 10 seconds. Screen 4 – The control “gathers” system information.

Screen 5 – Set the Mode of Operation to Demo Mode. See figure at right. Screen 6 – Select the type of indoor equipment to demo.

Screen 7 – Select the type of outdoor equipment to demo.

NON-ADJUSTABLE SETTINGS/FUNCTIONALITY

Homeowner:

Setting / Functionality

Access Path

Notes

View Equipment / Accessory Details

Menu > Status

Device icons are not selectable.

Service:

Setting / Functionality

Access Path

Notes

View Equipment / Accessory Details

Main Status screen

Device icons are not selectable.

Edit Dealer Information / Logo

Menu > Tools/Settings > Dealer Information

Edit button is not present.

System Event:

The communicating control will display the following system event 2 minutes after power up:

Air Filter Reminder Expired – applies to all systems

Equipment Faults:

The communicating control will display the following equipment faults 3 and 4 minutes after power up: Limit Switch Open – applies to all Air Handler applications

Soft Limit Warning – applies to all Furnace applications Ambient Sensor Open – applies to all Heat Pump applications HPS Lockout – applies to all Air Conditioner applications

Status Screen:

With each Refresh button press, the system will toggle through pre programmed states for all devices:

9 States – applies to Heat Pump application

 

 

 

 

 

 

 

 

 

 

UV

EAC

 

 

Thermostat

Humidifier

(HP4)

(HP15)

AH

AC

ON

OFF

ON

OFF

FAULT

OFF

 

 

 

 

 

TIME

ON

OFF

ON

ON

FAN

DELAY

ON

OFF

10%

10%

FAN

LO COOL

ON

OFF

10%

10%

FAN

HI COOL

ON

ON

ON

ON

FAN

LO HEAT

ON

ON

ON

ON

FAN

HI HEAT

ON

OFF

10%

10%

4.8KW

DEFROST

ON

10%

10%

10%

14.4KW

HI HEAT

ON

10%

ON

ON

14.4KW

FAULT

6 States – applies to Air Conditioner applications

 

Humidifier

 

 

 

 

Thermostat

(AC8)

UV

EAC

AH

AC

ON

OFF

ON

OFF

FAULT

OFF

 

 

 

 

 

TIME

ON

OFF

ON

ON

FAN

DELAY

 

 

 

 

 

LO

ON

OFF

10%

10%

FAN

COOL

 

 

 

 

 

HI

ON

OFF

ON

10%

FAN

COOL

ON

10%

ON

ON

4.8KW

OFF

ON

ON

ON

ON

14.4KW

FAULT

AVAILABLE SETTINGS

Reference the User’s Information and Installation Manuals for adjusting the all other settings not listed above.