Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions. Failure to comply with instructions could result in personal injury and/or damage to product or property. Please retain instruction sheet for future reference.
IMPORTANT SAFETY INSTRUCTIONS
Read completely before beginning. If you feel you do not have adequate electrical wiring experience, have this installed by
a qualied licensed electrican.
All electrical connections must be in accordance with local codes, ordinances and the National Electric Code. This product
operates on 120V AC; always conrm the maximum wattage of the linear xture does not exceed the maximum wattage of the circuit it is connected to. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualied
licensed electrician.
Read and follow all safety instructions.
1.
Read completely before beginning. If you feel you do not have adequate electrical wiring experience, have this
2.
installed by a qualied licensed electrician.
All electrical connections must be in accordance with local codes, ordinances and the National Electric Code.
3.
This product operates on 120V AC; always conrm the maximum wattage of the linear xture does not exceed the
maximum wattage of the circuit it is connected to. If you are unfamiliar with methods of installing electrical wiring,
secure the services of a qualied licensed electrician.
4.
Do not install the linear xture if any damage is seen on the product or power cables.
5.
Prior to starting the installation, disconnect the power by turning off the circuit breaker or removing the appropriate
fuse. (Turning off power using the light switch is not sufcient to prevent electrical shock).
TURN OFF ELECTRICITY
at main fuse box (or circuit breaker box)
before beginning installation by switching circuit breaker off or removing fuse.
MIN 90º C SUPPLY CONDUCTORS.
300W MAX
connected run
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT
RATED 120 VOLT AC
20W per 2 feet xture (15units MAX) 40W per 4 feet xture (7 units MAX) 80W per 8 feet xture (3 units MAX)
MOUNTING OPTIONS
Single or Linearly Connected Ceiling Mounting with Cables
Single or multiple xtures connected linearly. (See page 2)
Multiple Side-by-Side Ceiling Mounting with Cables
Multiple xtures connected side-by-side. (See page 4)
Surface Mounting with Clips
Single or Multiple xtures connected linearly. (See page 7)
FOR ELECTRICAL CONNECTION, SEE PAGE 8
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
JW 06/14/2017
Page 1 of 8
MLX
END FEED TOP FEED
C2
C1
C2
MULTI-LINX LED Fixture
Modular Linkable Linear Fixture
MULTI-LINX
Designed, Developed and Assembled in the U .S.A
CABLE SUSPENSION (LINEARLY CONNECTED) INSTALLATION INSTRUCTIONS
REQUIRED COMPONENTS FOR SINGLE FIXTURE INSTALLATION
A B C D E
MLX-(24/48/96)
MLX-PC(05/10) MLX-PC-HW(05/10) MLX-PC(05/10)-TF MLX-PC-HW(05/10)-TF
MLX-SCK-(1/2) MLX-MEC MLX-FEC
required for top
feed (-TF) input
ADDITIONAL COMPONENTS REQUIRED FOR CONNECTING MULTIPLE FIXTURES
F G H
SUSPENSION WITH CABLES
Single or Multiple xtures connected
linearly.
MLX-DC with MLX-CC-(06/12/18)MLX-DCS
OR
TOOLS REQUIRED HARDWARE INCLUDED with MLX-SCK
1/4” DRILL BIT
1/8” DRILL BIT
MINI PHILLIPS SCREWDRIVER
1
A A
MLX MLX
D D
MLX- MEC
COUPLER MOUNT
C1
2
MASONRY DRYWALL/CEILING TILE METAL STUD WOOD
C2
DRILL 1/4” HOLE
PLASTIC ANCHOR
COUPLER MOUNT
C1
MOUNTING SCREW
COUPLER
CABLE
C3
POWER DRILL WITH:
PHILLIPS BIT
MLX- MEC
MLX-PC(05/10)-TF
B
MLX-PC-HW(05/10)-TF
CABLE GRIP
T-NUT MOUNT
MLX-PC(05/10)
B
MLX-PC-HW(05/10)
COUPLER
Locking Screw
INPUTOUTPUT
A-A B-B
C3
CABLE
C
MLX-SCK
A-A B-B
DRILL 1/8” HOLE
COUPLER MOUNT
MOUNTING SCREW
COUPLER
CABLE
C3
MLX-24 18”(46cm) | MLX-48 44”(112cm) | MLX-96 88”(224cm)Recommended MLX-SCK Spacing:
C4
MOUNTING SCREWS WIRE CUTTER PLASTIC ANCHOR
FOR USE WITH DRYWALL
E
MLX- FEC
1 A-A Plug in MLX-PC or MLX-PC-HW into MLX xture’s
B
A
input port and secure power connector to xture with provided mounting screws with a mini-phillips screwdriver.
B
1 B-B Top feed cable is pre-wired onto MLX xture
A
Single Pendant Installation
INPUTOUTPUT
port. Top feed xture insert: MLX-MEC into MLX’s output port and insert MLX-FEC into MLX’s input port.
C5
Multiple Fixtures Installation Insert (1) MLX-DC or (1) MLX-CC to the output connection of all connecting xtures.
D
E
For the last connecting xture. Insert MLX-MEC to the
End feed xture Insert: MLX-MEC into MLX’s output
AD
A
A
F H
D
output connection.
2 Based on building material of intended mounting surface,
determine the best mounting method. Each MLX xture requires (2) MLX-SCK for installation, recommended distance between each MLX-SCK is determined by
A
MLX xture’s length.
C
C
A
2 A-A Drill a 1/4” hole in mounting surface and make sure
the depth is at least 1/4” past the length of the plastic anchor. Insert plastic anchor in drilled hole. Insert mounting screw through COUPLER MOUNT and screw into plastic anchor. Repeat the process for second COUPLER MOUNT, then secure COUPLER with CABLE to COUPLER
C1
C2 C3
C1
C1
MOUNT by hand.
2 B-B Drill a 1/8” pilot hole and fasten mounting screw and
C1
COUPLER MOUNT on to mounting surface. Repeat the process for second COUPLER MOUNT.
C1
Continue on page 3 ----
>
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
JW 06/14/2017
Page 2 of 8
MLX
G3
F
NUT
RIGID PLATE
T-NUT BAR
G1
G2
G3
A
8 mm| 5/16 in
NUT DRIVER
F
INPUT
OUTPUT
MLX-DC
CABLE GRIP
CABLE GRIP
T-NUT MOUNT
T-NUT MOUNT
C4
C5
C4
C5
MLX-DC
MLX-DCS
NUT
RIGID PLATE
T-NUT BAR
G1
G2
G3
8 mm| 5/16 in
NUT DRIVER
F
INPUT
OUTPUT
MLX-DC
C4
C4
MULTI-LINX LED Fixture
Modular Linkable Linear Fixture
MULTI-LINX
Designed, Developed and Assembled in the U .S.A
CABLE SUSPENSION (LINEARLY CONNECTED) INSTALLATION INSTRUCTIONS
3
4
5
G
MLX-DCS
MLX-DC
C5
A-A
CABLE GRIP
T-NUT MOUNT
A
CABLE GRIP
3 A-A Attach CABLE GRIP to T-NUT MOUNT, do not tighten
C4
all the way.
C4
C5
A
T-NUT MOUNT
3 B-B Slide 2x & assembly into slot on top of MLX xture
C5
B-B
A C3
4 Bring MLX xture up to where CABLES are installed. Insert
C3
CABLE into CABLE GRIP by pushing down on the spring
C4
locking mechanism, pull out CABLE from exit hole on
C3
C4
CABLE
CABLE GRIP
PUSH
C4 C4
CABLE GRIP, release spring mechanism on CABLE GRIP when desired height is reached. Repeat the process with the
second CABLE. Adjust as needed to ensure xture is level.
C3
INSTALLATION OF MULTIPLE LINEAR FIXTURES
5 Installation of Multiple Fixtures with MLX-DC
G1
G2
MLX-DC
F
NUT
RIGID PLATE
T-NUT BAR
OUTPUT
NUT DRIVER
8 mm| 5/16 in
Plug in (1) MLX-DC between every (2) MLX xtures that will
F
be connected. Slide in T-NUT BAR as illustrated onto the slot on
A
top of MLX xture at the output side.
5 A-A Match and insert RIGID PLATE mounting holes to
T-NUT BAR’s screw posts. Partially secure NUT on T-NUT BAR’s screw posts, do not tighten. 5 B-B Connect second MLX xture via input port to direct connector in rst MLX xture
5 C-C Slide RIGID PLATE and T-NUT BAR to the center of 2
G2
connected MLX xtures. Tighten nuts on T-Bar with a NUT DRIVER.
Follow STEP 4 on hanging instructions.
G3
G2
C5
A
C3
A
G3
G3G1
F
G3
A-A
6
B-B
MLX-CC-(6/12/18)
H
INPUT
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
INPUT
C-C
OUTPUT
Instruction sheet subject to change without prior notice.
6 Multiple Fixtures Connected with MLX-CC Follow STEP 4 on hanging instructions then proceed to below instructions
H
Plug in CONNECTING CABLE to input and output port to power
adjacent MLX xtures.
For Electrical Connection, See Page 8 >>>
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
JW 06/14/2017
Page 3 of 8
MLX
C1
C2
C2
C3
C5
CABLE
CABLE GRIP
C3
A
C4
PUSH
MULTI-LINX LED Fixture
Modular Linkable Linear Fixture
MULTI-LINX
Designed, Developed and Assembled in the U .S.A
CABLE SUSPENSION (SIDE-BY-SIDE) INSTALLATION INSTRUCTIONS
COMPONENTS FOR MULTIPLE FIXTURES INSTALLATION (varies by conguration)
A B C D E
MLX-(24/48/96)
MLX-PC(05/10)
MLX-SCK-(1/2) MLX-MEC MLX-FEC MLX-PC-HW(05/10) MLX-PC(05/10)-TF MLX-PC-HW(05/10)-TF
F G H
SUSPENSION WITH CABLES
Multiple xtures connected side by side
MLX-MBCONMLX-FBCON
MLX-XB-(2/3/4/5/6)
TOOLS REQUIRED HARDWARE INCLUDED with MLX-SCK
1/4” DRILL BIT
1/8” DRILL BIT
MINI PHILLIPS SCREWDRIVER
COUPLER MOUNT
C1
1
MASONRY DRYWALL/CEILING TILE METAL STUD WOOD
DRILL 1/4” HOLE
PLASTIC ANCHOR
COUPLER MOUNT
MOUNTING SCREW
COUPLER
CABLE
C3
2
MLX-24 18”(46cm) MLX-48 44”(112cm) MLX-96 88”(224cm)
POWER DRILL WITH:
PHILLIPS BIT
C2
COUPLER
C
MLX-SCK
CABLE
CABLE GRIP
A-A B-B
DRILL 1/8” HOLE
COUPLER MOUNT
C1
MOUNTING SCREW
C3
T-NUT MOUNT
C4
COUPLER
CABLE
2 FIXTURES 2-3/8” (60mm) 3 FIXTURES 4-3/4” (121mm) 4 FIXTURES 7-3/16” (183mm) 5 FIXTURES 9-9/16” (243mm) 6 FIXTURES 11-7/8” (302mm)
MOUNTING SCREWS WIRE CUTTER PLASTIC ANCHOR
FOR USE WITH DRYWALL AND CEILING TILES
MAX SIDE BY SIDE CONNECTED FIXTURES - 300W
MLX-24 MAX-6 FIXTURES (120W) MLX-48 MAX-6 FIXTURES (240W) MLX-96 MAX-3 FIXTURES (240W)
INSTALLING HANGING CABLE 1 Based on building material on intended mounting surface,
determine the best mounting method. Each MLX xture requires (2) MLX-SCK for installation, recommended distance between each MLX-SCK is determined by
A
MLX xture’s length and numbers of xtures connected
C
C
A
as recommended in STEP 2
1 A-A Drill a 1/4” hole on mounting surface and make sure the depth is at least 1/4” pass the length of the plastic anchor. Insert plastic anchor in drilled hole. Fasten mounting screw and COUPLER MOUNT into the plastic anchor. Repeat the process for second COUPLER MOUNT, then secure COUPLER with CABLE to COUPLER
C2 C3
C1
C1
C1
MOUNT by hand.
1 B-B Drill a 1/8” pilot hole and fasten mounting screw and
C1
COUPLER MOUNT on to mounting surface. Repeat the process for all COUPLER MOUNT needed for installation.
C1
Continue on page 5 ----
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
JW 06/14/2017
Page 4 of 8
>
MLX-FBCON
MLX-PC(5/10) MLX-PC-HW(5/10)
D
G
FH1H2
H3
H3
H2
H1
B
A
INPUT OUTPUT
B
110V
GGGGG
D
EFFFF
D
G
F
H1
H2
H3
H3
H2
H1
B
A
8 mm| 5/16 in
NUT DRIVER
MLX
MULTI-LINX LED Fixture
Modular Linkable Linear Fixture
CABLE SUSPENSION (SIDE-BY-SIDE) INSTALLATION INSTRUCTIONS
MULTI-LINX
Designed, Developed and Assembled in the U .S.A
3
H
NUT
H1
CROSS BAR
H2
H3
4”(102mm)
H3
MLX-XB-(2/3/4/5/6)
3 Insert (2) T-NUT onto the slot on top at the ends of each connected MLX xture. Place T-nut 4 inches away from end of MLX xture.
H3 H3
T-NUT
A
A
A
4
MLX-FBCON
NUT
NUT DRIVER
8 mm| 5/16 in
NUT
MLX-XB-(2/3/4/ 5 /6)
T-NUT
MLX-PC(5/10) MLX-PC-HW(5/10)
MLX-XB-(2/3/4/ 5 /6)
T-NUT
MLX-MEC
MLX-MBCON
INPUT OUTPUT
4 Arrange connecting xtures side by side, making sure all input ports are together on one side and all output ports are on the other. Align and place MLX-XB over T-NUT, secure MLX-XB with NUT using a NUT DRIVER.
H2 H2H3 H3
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
Continue on page 6 ----
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
>
JW 06/14/2017
Page 5 of 8
MLX
MLX-FBCON
MLX-FBCON
MLX-PC(5/10) MLX-PC-HW(5/10)
D
G
F
H1
H2
H3
H3
H2
H1
B
A
B
EDG
G
F
INPUT OUTPUT
110V
B
110V
B
110V
B
110V
B
110V
GGGGGGG
D
E
EFF
FFF
T-NUT
MLX-XB-(2/3/4/ 5 /6)
MLX-FBCON
MLX-MBCON
MLX-FBCON
MLX-PC(5/10) MLX-PC-HW(5/10)
NUT
T-NUT
NUT
MLX-MEC
D
G
F
H1
H2
H3
MLX-XB-(2/3/4/ 5 /6)
H3
H2
H1
B
A
INPUT OUTPUT
8 mm| 5/16 in
NUT DRIVER
MLX-DC
MLX-DCS
NUT
RIGID PLATE
T-NUT BAR
G1
G2
G3
A
8 mm| 5/16 in
NUT DRIVER
F
INPUT
OUTPUT
MLX-DC
CABLE GRIP
T-NUT MOUNT
C4
C5
C4
NUT
RIGID PLATE
T-NUT BAR
G1
G2
G3
8 mm| 5/16 in
NUT DRIVER
F
INPUT
OUTPUT
MLX-DC
C4
MULTI-LINX LED Fixture
Modular Linkable Linear Fixture
MULTI-LINX
Designed, Developed and Assembled in the U .S.A
CABLE SUSPENSION (SIDE-BY-SIDE) INSTALLATION INSTRUCTIONS
5
5 Reference above diagam for different side by side connected congurations and determine placement and quantity of MLX-FBON,
G D E
MLX-MBON, MLX-MEC, and /or MLX-FEC required for installation.
6
6 A-A Attach CABLE GRIP to T-NUT MOUNT, do not tighten all the way. 6 B-B Reference diagram for & assembly placement in different side-by-side connected conguration. 6 C-C From the ends of MLX xture, slide & assembly into slot on top as illustrated.
7
CABLE GRIP
A
C5
T-NUT MOUNT
A-A B-B C-C
C4
C5
C4
A
A
C5
C4
C5
C3
C4
CABLE
CABLE GRIP
PUSH
F
CABLE GRIP
C5
T-NUT MOUNT
A C3
7 Bring side-by-side connected MLX xture up to where CABLES are installed. Insert CABLE into CABLE GRIP by pushing down
on the spring locking mechanism, pull out CABLE from exit hole on CABLE GRIP, release spring mechanism on CABLE GRIP when
desired height is reached. Repeat the process with the all the installed CABLES. Adjust as needed to ensure xture is level.
C3
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
C4 C4
C3
C3
For Electrical Connection, See Page 8 >>>
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
Instruction sheet subject to change without prior notice.
C4
JW 06/14/2017
Page 6 of 8
MLX
MLX
MLX-PC(05/10)-TF MLX-PC-HW(05/10)-TF
MLX- MEC
MLX- FEC
INPUTOUTPUT
MLX-PC(05/10) MLX-PC-HW(05/10)
MLX MLX
MLX- MEC
Locking Screw
INPUTOUTPUT
END FEED TOP FEED
MLX-PC(05/10)-TF MLX-PC-HW(05/10)-TF
MLX- MEC
MLX- FEC
INPUTOUTPUT
MLX-24 18”(46cm) | MLX-48 44”(112cm) | MLX-96 88”(224cm)Recommended MLX-MC Spacing:
PLASTIC ANCHOR
MLX-MC
#8 SELF-TAPPING SCREW
DRILL 1/4” HOLE
MASONRY DRYWALL/CEILING TILE
MLX-PC(05/10) MLX-PC-HW(05/10)
MLX MLX
Locking Screw
METAL STUD WOOD
DRILL 1/8” HOLE
MLX-MC
MLX-DC
OR
MLX-CC-06/12/18
INPUTOUTPUT
END FEED TOP FEED
#8 SELF-TAPPING SCREW
MLX-PC(05/10)-TF MLX-PC-HW(05/10)-TF
MLX- MEC
MLX- FEC
INPUTOUTPUT
MLX MLX
MULTI-LINX LED Fixture
Modular Linkable Linear Fixture
SURFACE MOUNTING INSTALLATION INSTRUCTIONS
MULTI-LINX
Designed, Developed and Assembled in the U .S.A
REQUIRED COMPONENTS FOR SINGLE FIXTURE INSTALLATION
MLX-(24/48/96)
A
MLX-PC(05/10)
B
MLX-PC-HW(05/10)
ADDITIONAL COMPONENTS REQUIRED FOR CONNECTING MULTIPLE FIXTURES
SURFACE MOUNTING WITH CLIPS
Single or Multiple xtures connected
linearly.
E F
MLX-DC MLX-CC-(06/12/18)
TOOLS REQUIRED HARDWARE REQUIRED
1/4” DRILL BIT
#8 SELF-TAPPING SCREWS
CHOOSE SCREW TYPE THAT BEST FOR THE INTENDED MOUNTING SURFACE
(Not INcluded)
1 Plug in MLX-PC or MLX-PC-HW into MLX xture’s input port and secure power connector to xture with provided locking screws with a mini-phillips screwdriver.
Single Fixture Installation Insert MLX-MEC into MLX’s output port.
Multiple Fixtures Installation Insert MLX-DC or MLX- CC into the output port of all connecting xtures, except for the last connecting xture. Insert MLX-MEC to the output port of the last connecting xture.
2 Based on building material on intended mounting surface, determine the best mounting method. Each
A
MLX xture requires two MLX-MC for installation. Recommended distance between each MLX-MC is determined by MLX xture length as noted.
2 A-A Drill a 1/4” hole on mounting surface and make sure the depth is at least 1/4” past the length of the plastic
anchor. Insert plastic anchor in drilled hole. Screw self­tapping screw and MLX-MC into the plastic anchor. Repeat the process for second MLX-MC, then snap in
A
MLX xture on to the two MLX-MC.
MINI PHILLIPS
POWER DRILL WITH:
SCREWDRIVER
1
MLX- MEC
D
2
MASONRY DRYWALL/CEILING TILE
A-A B-B
DRILL 1/4” HOLE
PLASTIC ANCHOR
MLX-MC
#8 SELF-TAPPING SCREW
1/8” DRILL BIT
PHILLIPS BIT
MLX-PC(05/10) MLX-PC-HW(05/10)
B
MLX
A
Locking Screw
INPUTOUTPUT
METAL STUD WOOD
DRILL 1/8” HOLE
MLX-MC
CC
#8 SELF-TAPPING SCREW
B
OR
C D
MLX-MC MLX-MEC
PLASTIC ANCHOR
FOR USE WITH DRYWALL AND CONCRETE SURFACES
(Not Included)
A
D
E F
D
C
C
C
C
A
MLX MLX
A A
MLX-24 18”(46cm) | MLX-48 44”(112cm) | MLX-96 88”(224cm)Recommended MLX-MC Spacing:
3
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
E
F
2 B-B Drill a 1/8” pilot hole. Screw self-tapping screw and
C
MLX-MC into mounting surface. Repeat the process for second MLX-MC, then snap in MLX xture on to the two MLX-MC.
C
C
A
3 Multiple Fixture Installation Once all the connecting
A
MLX xtures are mounted on MLX-MC, connect (1) MLX-DC or (1) MLX-CC to every (2) connecting MLX
E
F
C
A
xtures.
For Electrical Connection, See Page 8 >>>
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
JW 06/14/2017
Page 7 of 8
PLASTIC ANCHOR
COUPLER MOUNT
MOUNTING SCREW
DRILL 1/4” HOLE
DRILL 1/8” HOLE
COUPLER
MOUNTING SCREW
BLACK (HOT) WHITE (NEUTRAL) GREEN OR COPPER (GROUND)
SUPPLY WIRES
B-B
MLX-PC-HW(05/10) MLX-PC-HW(05/10)-TF
MLX-24 18”(46cm) | MLX-48 44”(112cm) | MLX-96 88”(224cm)Recommended MLX-SCK Spacing:
MLX-SCK
C
C1
C2
CABLE
C3
CABLE
C3
COUPLER MOUNT
COUPLER
C1
C2
C3
C5
MASONRY DRYWALL/CEILING TILE METAL STUD WOOD
DRILL 1/8” HOLE
MOUNTING SCREW
CABLE
C3
COUPLER MOUNT
COUPLER
C1
C2
C5
MLX
MULTI-LINX LED Fixture
Modular Linkable Linear Fixture
MULTI-LINX
Designed, Developed and Assembled in the U .S.A
ELECTRICAL WIRING INSTRUCTIONS
TURN OFF ELECTRICITY
at main fuse box (or circuit breaker box)
before beginning installation by switching circuit breaker off or removing fuse.
MIN 90º C SUPPLY CONDUCTORS.
300W MAX
connected run
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT
RATED 120 VOLT AC
20W per 2 feet xture (15units MAX) 40W per 4 feet xture (7 units MAX) 80W per 8 feet xture (3 units MAX)
A-A
MLX-PC (05/10) MLX-PC (05/10)-TF
A-A PLUG AND PLAY APPLICATIONS
Plug in MLX-PC(5/10) or MLX-PC(05/10)-TF to a
3 prong outlet.
SUPPLY WIRES
BLACK (HOT) WHITE (NEUTRAL) GREEN OR COPPER (GROUND)
B-B
MLX-PC-HW(05/10) MLX-PC-HW(05/10)-TF
B-B HARD WIRING APPLICATIONS
Connect MLX-PC-HW(5/10) or MLX-PC­HW(05/10)-TF to supply wires in a junction box. BLACK to BLACK
WHITE to WHITE GREEN to GREEN or COPPER
Secure all connections with wire nuts
(not included)
www.jescolighting.com support@jescolighting.com Tech Support: 855.592.0029
Instruction sheet subject to change without prior notice.
219 South 6th Ave City of Industry, CA 91746
Main Line: 855.654.0110 Fax Line: 626.333.2955
JW 06/14/2017
Page 8 of 8