Amplifier Installation and Operation
A400HLX
A600HLX
400
MOSFET Power Supply
4 channel bridgeable
HPF |
|
|
|
|
|
|
|
|
|
|
|
POWER |
FULL |
|
BASS |
L-CHX |
R-CHX |
|
LEVEL |
|
|||||
|
|
|
|
|||||||||
LPF |
3 |
|
5 |
60 |
125 |
60 |
125 |
2 |
|
|
4 |
|
FRONT |
|
|
|
|
|
|
|
|
|
|
|
PROTECT |
REAR |
|
|
|
|
|
|
|
|
|
|
|
2CH |
HPF |
|
0dB |
12dB |
40Hz |
400Hz |
40Hz |
400Hz |
|
8V |
.3V |
|
3CH |
FULL |
3 |
BASS |
L-CHX |
R-CHX |
|
LEVEL |
|
4CH |
||||
LPF |
|
5 |
60 |
125 |
60 |
125 |
2 |
|
|
4 |
MODE |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
0dB |
12dB |
40Hz |
400Hz |
40Hz |
400Hz |
|
8V |
.3V |
|
|
Introduction
Thank you for purchasing a Jensen amplifier. The HLX series amplifiers offer extreme value and performance. Proper installation is essential for optimal performance and long-term reliability. Please read through this manual first to familiarize yourself with your amplifier and its functions.
Warranty Service
If your Jensen amplifier should ever require service, you will need to have the original dated receipt. If you ever need to return the unit for any reason, always include the receipt with the product.
Installation Assistance
1.800.323.0221
REC002_A4n600HLX_E |
1 |
1/9/02, 4:13 PM |
® |
|
A400HLX, A600HLX |
|
|
|
Contents |
|
|
Features ......................................... |
3 |
|
Installation..................................... |
3 |
|
Before You Begin ......................................... |
3 |
|
Disconnect Battery ........................................ |
3 |
|
Supplies and Tools Needed .......................... |
3 |
|
Location and Mounting .................................. |
4 |
|
Routing Wires................................................ |
4 |
|
Wiring ............................................. |
5 |
|
Power ............................................................ |
5 |
|
Power Terminal (+12V) ................................. |
5 |
|
Ground Terminal (GND) ................................ |
5 |
|
Remote Terminal (REM) ............................... |
5 |
|
Fuses ............................................................ |
5 |
|
Inputs, RCA Output, |
|
|
Remote Level Control ................................. |
6 |
|
Input Wiring ................................................... |
6 |
|
Remote Level Control (A600HLX) ................ |
7 |
|
Connecting Other Amps ................................ |
7 |
|
Speaker Wiring Options ............................. |
8 |
|
Indicators and Controls ............................ |
10 |
|
Crossover (X-OVER) .................................. |
10 |
|
Power/Protect Light ..................................... |
10 |
|
2CH / 3CH / 4CH ........................................ |
11 |
|
Level............................................................ |
12 |
|
Bass ............................................................ |
12 |
|
Testing ......................................... |
12 |
|
Reconnect Battery ...................................... |
12 |
|
Test Power Wiring ....................................... |
12 |
|
Test Speaker Connections .......................... |
12 |
|
Troubleshooting........................... |
13 |
|
Specifications .............................. |
14 |
|
Warranty ...................................... |
15 |
|
2
REC002_A4n600HLX_E |
2 |
1/9/02, 4:13 PM |
®
A400HLX, A600HLX
Features
A400HLX/A600HLX 4-channel amplifiers include: |
|
|
||
• |
Easy access top mounted controls |
• |
Traditional input circuitry – low and high level |
|
• |
Continuously variable high pass/low pass |
|
inputs |
|
• |
Pre-amp output for installation flexibility |
|||
|
crossover |
|||
• |
40Hz – 400Hz crossover frequency range |
• |
Dual status LED diagnostic indicator |
|
• |
Crossover mode selector switch |
• |
Thermal, short circuit and low impedance |
|
• |
Continuously variable bass boost, centered |
|
protection circuitry |
|
• PWM MOSFET power supply |
||||
|
at 45Hz |
|||
• |
Input level control |
• |
Discrete amplifier design with complementary |
|
• Remote level control (A600HLX) |
|
high current Bi-polar output stage |
||
|
|
|||
|
|
|
|
Installation
Before You Begin
Before you begin, you will need tools, supplies and adapters. It is best to make sure you have everything you need before you start.
Disconnect Battery
Before you begin, always |
|
disconnect the battery |
|
negative terminal. |
+ |
|
– |
Supplies and Tools Needed
Supplies
•Black electrical tape
•Amplifier Installation Kit
Tools
•Cordless drill with assortment of bits
•Flat and Phillips screwdrivers
•Wire cutters/strippers
•Crimping tool
•12-volt test light or digital multimeter
•Wire brush, sandpaper or scraping tool (ground connection to vehicle should be a clean, unpainted metal surface)
3
REC002_A4n600HLX_E |
3 |
1/9/02, 4:13 PM |
®
Location and Mounting
The A400HLX/A600HLX amplifier’s compact design allows greater flexibility in mounting. It can be mounted under a seat or in the trunk.
When selecting a location, remember that amplifiers generate heat. Select a location where air can circulate around the amplifier. Do not cover the amplifier with carpets or enclose it behind interior trim panels. Do not mount the amplifier in an inverted or upside down configuration. Every installation will be a bit different based upon vehicle design. Check all locations and placements carefully before making any cuts or connections.
Important
Allow air circulation around the amplifier.
4
A400HLX, A600HLX
Routing Wires
Battery
|
|
Battery |
|
|
|
Connector |
|
|
Fuse or |
|
|
|
Circuit |
|
|
|
Breaker |
Grommet |
|
|
|
||
|
|
To prevent |
|
|
|
damage to |
|
|
|
power wire |
|
Receiver |
|
||
RCA Cables |
Power Antenna |
Power Wire |
|
(8 gauge |
|||
|
Turn-on Wire |
(18 gauge wire) |
wire or |
|
larger) |
||
|
||
Speakers |
|
Amplifier
Ground Screw
Drill 1/8" hole in chassis sheet metal
Use the same ground if using multiple amplifiers
Important
If wiring connections are made wrong, the unit will not operate properly and it could be damaged. Follow the installation instructions carefully, or have the installation handled by an experienced technician.
REC002_A4n600HLX_E |
4 |
1/9/02, 4:13 PM |
®
A400HLX, A600HLX
Wiring
Power
|
BRIDGE |
|
|
|
BRIDGE |
|
|
RF |
RF – |
LF |
LF + |
RR |
RR – |
LR |
LR + |
GND REM + 12V
FUSE
Power Terminal (+12V)
Connect directly to the vehicle battery+ terminal with 8 gauge wire (minimum).
|
|
GND |
REM |
+ 12V |
|
Fuse: |
|
|
|
|
|
A400HLX 50 AMP |
|
|
|
|
|
A600HLX 70 AMP |
|
|
|
Spade |
|
|
|
|
|
|
|
|
|
|
|
|
Connector |
|
Fuse or |
|
|
|
|
|
Circuit Breaker |
|
|
|
|
|
|
|
|
|
8 Gauge |
Battery |
Install as close |
To Battery+ |
Wire |
||
|
|||||
|
Terminal |
|
|
||
Terminal |
to the battery |
|
|
|
|
|
|
|
|
||
Adapter |
as possible |
|
|
|
|
Remote Terminal (REM)
Connect the power antenna/amplifier turn-on lead from the receiver to the AMPLIFIER REMOTE terminal.
GND |
REM |
+ 12V |
Spade
Connector
18 Gauge
Wire
To Receiver
Power
Antenna Lead
Ground Terminal (GND)
Connect to a good chassis ground. The ground connection should be to clean, unpainted metal to provide a good electrical connection.
GND |
REM |
+ 12V |
Spade
Sheet Metal Connector
Screw
8 Gauge
Wire
Drill 1/8" hole in chassis sheet metal
Fuses
Use only blade-type fuses.
Fuse:
A400HLX 2 x 25 AMP
A600HLX 2 x 35 AMP
FUSE
5
REC002_A4n600HLX_E |
5 |