Jenn-Air S136, S136W, S156, S156W, S176 Dimension Guide

...
4 (1)
Jenn-Air S136, S136W, S156, S156W, S176 Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

This Data Sheet Includes Information On

 

 

Jenn-Air

 

 

 

Product Model Number (s):

 

Downdraft Electric Grill-Range Ovens:

 

 

S136, S136W, S156, S156W, S176 and S176W

 

Dimensions (Actual Size)

 

Width:

29

15/16"

 

 

Depth:

26

3/8"

 

Height: 35 1/2"

Door swing: 20"

Height at full leg adjustment: 36"

Height at 0" leg adjustment: 35 1/2"

Additional Information

Units can be installed as a Freestanding unit or Slide-In unit. Slide-in installation does NOT allow for use of a backsplash or side panels. If either is desired, use the free-standing cutout and instructions.

Units depth including door handle is 28 3/8".

Electrical requirements: 120/240 VAC or 120/208 VAC, 60Hz. 50 amp grounded circuit protection is recommended, 40 amp minimum required.

Cabinetry over cooktop : 30' minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or copper.

To eliminate the hazard of reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.

Range complies with U.L. requirements for 1" clearance from the range to adjacent vertical side walls and 7/8" from rear wall. Abnormal surface unit operation could result in possible scorching of vertical walls and pose potential fire hazard. Therefore, a 6" minimum spacing is recommended.

For Free-standing installations the cutout opening width is 30 1/8" ± 1/16" minimum. The height of the countertop is 36" and countertop depth is 25". The cooktop does NOT need to be notched for Free-standing installations.

See page 2 for Slide-in installation specifications

Accepts Jenn-Air Designer Style cartridges.

See page 1A-5 for additional information

Subject to change without notice. This system is designed to

 

be updated daily if necessary. Dimension Express is not

 

responsible for use of superseded, voided, or outdated data

 

sheets. Because of the difficulty or impracticability of deter-

 

mining actual damages, liability of Dimension Express shall

 

not exceed $50.00.

 

Copyright © Dimension Express, 2000.

174

29 15/16"

26 3/8"

(not to scale)

35 1/2"

20"

 

Locate electrical

 

supply junction

Wall View

box or 60" of

electrical cable

(not to scale)

within shaded

 

area.

4 1/2"

3"

5"

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Upper cabinets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

can only be 13"

Wall View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

deep maximum.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Over range

(not to scale)

 

 

 

30"

Min.

 

 

 

 

 

cabinet is NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

recommended.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearance between the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30"

 

 

 

 

 

 

 

 

 

 

edge of the appliance and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

combustible construction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6" extending from the

 

 

 

 

18"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cooking surface to 18"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

above the cooking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

surface is 1" to the sides

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and 7/8" to the back (see

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

solid areas). 6" Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is recommended.

Countertop

 

 

 

 

 

Range

 

 

 

 

 

 

 

 

 

 

 

height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 1/8" Minimum cutout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

width for Free-standing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

instalations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN221 • A174B282C315D150E123F124 • 31469 • 002906 • 143524 • 12927

associated with reusing old Data Sheets.

www.dexpress.com

 

 

 

This Data Sheet Includes Information On

 

 

DIMENSION EXPRESS

 

 

 

Jenn-Air

 

 

Page 1a

 

Product Model Number (s):

 

 

 

 

 

Fax on Demand (775) 833-3600

 

 

Downdraft Electric Grill-Range Ovens:

 

 

 

 

 

 

 

 

 

 

 

S136, S136W, S156, S156W, S176 and S176W

 

 

Additional Information:

For European style cabinets (flush front) the required clearance for operation of the oven door is a minimum spacing of 7/8" between the cutout and adjacent door, hinge or drawer of the cabinet.

Island or peninsula installations with 24" deep base cabinets must use flush back (no rear toe space) cabinets to avoid range interference,. If rear toe space is desired, use 27" or deeper cabinets.

S136, S156 and S176 : Black.

S136W, S156W and S176W : White.

Kits:

A501WT : 2 White side panels for freestanding range installations.

A501BT : 2 Black side panels for freestanding range installations.

A501LT : 2 Almond side panels for freestanding range installations.

A507 : Custom backsplash for freestanding range installations.

A510 : Trim Kit base for freestanding range installations.

A519 : Deluxe black lighted backsplash for freestanding range installations.

A519W : Deluxe white lighted backsplash for freestanding range installations.

Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.

Copyright © Dimension Express, 2000.

282

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN221 • A174B282C315D150E123F124 • 31469 • 002906 • 143524 • 12927