This Data Sheet Includes Information On

 

 

 

 

 

 

 

 

 

 

 

36"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jenn-Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Model Number (s):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36" Gas Cooktops:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 13/16"

 

 

 

 

21 9/16"

 

JGC8536ADB, JGC8536ADW, JGC8536ADQ and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JGC8536ADS

 

 

 

Side View (not to scale)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions (Actual Size)

 

 

 

 

 

 

 

Overall Dimensions

 

Overall width: 36"

 

 

 

 

 

 

 

 

 

 

Top View (not to scale)

Overall depth: 21 9/16"

Distance from top of counter to bottom of unit: 3 13/16"

 

Cut-Out width: 34 7/8"

 

 

 

Cut-Out Dimensions

 

Cut-Out depth: 20 13/16"

 

 

20 13/16"

 

 

 

Countertop View

Min. spacing from cooktop edge to nearest

 

 

 

 

 

 

(not to scale)

vertical combustible wall to the RIGHT: 8"

 

 

 

 

 

34 7/8"

 

Min. spacing from cooktop edge to nearest

 

 

 

 

 

 

 

vertical combustible wall to the LEFT: 8"

 

 

 

 

Min. spacing from cooktop edge to nearest

 

 

 

 

vertical combustible wall to the REAR: 3/4"

 

 

 

 

Minimum spacing to front edge of counter: 2"

 

 

 

 

Minimum distance between cooktop

 

 

 

 

 

and cabinet directly above: 30" min

 

 

 

Cabinet Requirements

Minimum

width of cabinet directly above: 36"

 

 

 

Wall View

Maximum depth of cabinets directly

 

 

 

(not to scale)

 

 

 

 

 

above and adjacent: 13"

 

 

36"

 

Minimum distance between countertop

 

 

 

Minimum horizontal

 

and adjacent cabinet above: 18"

 

 

30" min

Additional Information

18"

 

clearance between the

 

edge of the appliance

• Distance from top of counter to bottom of gas stub is

 

 

 

 

 

and combustible

4 9/16".

 

 

 

 

 

 

 

 

construction extending

• Distance from top of counter including manifold

 

 

 

 

 

 

from the cooking

entrance is 7 1/2.

 

 

 

 

 

 

surface to 18" above

• Electrical requirements : 110/120 volt AC, 60hz. Must

 

 

 

 

the cooking surface is

be grounded. 15amp circuit required. Locate outlet

 

 

 

 

 

 

8" (see solid areas)

below the cooktop a minimum of 5" below the

 

 

 

 

 

 

 

countertop if not installing over an under counter oven.

 

 

 

Locate outlet below the oven or in an adjacent cabinet

 

 

 

 

when installing over an adjacent under counter oven.

 

 

 

 

• Minimum clearance from top of counter to combustible

 

 

 

material below is 4 7/16"

 

 

 

 

• Countertop must be supported within 3" of cutout.

 

 

 

 

• Unit may be installed over a Jenn-Air under counter

1 3/4" to centerline of pipe from

Top view of cutout

oven.

 

 

 

(not to scale)

 

 

back edge of cutout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See page 2 for additional information

 

 

Gas inlet location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 3/4" from left side

 

 

 

 

 

 

 

 

 

 

 

of cutout to

 

 

 

 

 

 

 

 

 

 

 

 

centerline of pipe.

 

 

 

 

 

 

 

 

Subject to change without notice. This system is designed to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be updated daily if necessary. Dimension Express is not

 

 

 

 

 

 

 

 

 

 

 

 

responsible for use of superseded, voided, or outdated data

 

 

 

 

 

 

 

 

 

 

 

 

sheets. Because of the difficulty or impracticability of deter-

 

 

 

 

 

 

 

 

 

 

 

 

mining actual damages, liability of Dimension Express shall

 

 

Cooktop supplied with 1/2" NPT female inlet on regulator

not exceed $50.00.

 

 

Copyright © Dimension Express, 2003.

321

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

 

 

 

 

BN182.34 • A321B149 • • 031111 • 115727 • 89750

associated with reusing old Data Sheets.

 

 

 

 

 

 

Loading...
+ 1 hidden pages