FEATURES
•Clock frequency: 166, 133, 100 MHz
•Fully synchronous; all signals referenced to a positive clock edge
•Internal bank for hiding row access/precharge
•Single 3.3V power supply
•LVTTL interface
•Programmable burst length
– (1, 2, 4, 8, full page)
•Programmable burst sequence: Sequential/Interleave
•Self refresh modes
•4096 refresh cycles every 64 ms
•Random column address every clock cycle
•Programmable CAS latency (2, 3 clocks)
•Burst read/write and burst read/single write operations capability
•Burst termination by burst stop and precharge command
•Byte controlled by LDQM and UDQM
•Industrial temperature availability
•Package: 400-mil 54-pin TSOP II
OVERVIEW
ISSI's 64Mb Synchronous DRAM IS42S16400 is organized as 1,048,576 bits x 16-bit x 4-bank for improved performance. ThesynchronousDRAMsachievehigh-speed data transfer using pipeline architecture. All inputs and outputs signals refer to the rising edge of the clock input.
PIN CONFIGURATIONS
54-Pin TSOP (Type II)
VCC |
|
|
1 |
54 |
|
|
|
GND |
||
I/O0 |
|
|
|
53 |
|
|
|
I/O15 |
||
|
|
|
2 |
|
|
|
||||
VCCQ |
|
|
|
52 |
|
|
|
GNDQ |
||
|
|
|
3 |
|
|
|
||||
I/O1 |
|
|
|
51 |
|
|
|
I/O14 |
||
|
|
|
4 |
|
|
|
||||
I/O2 |
|
|
|
50 |
|
|
|
I/O13 |
||
|
|
|
5 |
|
|
|
||||
GNDQ |
|
|
|
49 |
|
|
|
VCCQ |
||
|
|
|
6 |
|
|
|
||||
I/O3 |
|
|
|
48 |
|
|
|
I/O12 |
||
|
|
|
7 |
|
|
|
||||
I/O4 |
|
|
|
8 |
47 |
|
|
|
I/O11 |
|
|
|
|
|
|
|
|||||
VCCQ |
|
|
|
46 |
|
|
|
GNDQ |
||
|
|
|
9 |
|
|
|
||||
I/O5 |
|
|
|
45 |
|
|
|
I/O10 |
||
|
|
|
10 |
|
|
|
||||
I/O6 |
|
|
|
44 |
|
|
|
I/O9 |
||
|
|
|
11 |
|
|
|
||||
GNDQ |
|
|
|
43 |
|
|
|
VCCQ |
||
|
|
|
12 |
|
|
|
||||
I/O7 |
|
|
|
13 |
42 |
|
|
|
I/O8 |
|
|
|
|
|
|
|
|||||
VCC |
|
|
|
14 |
41 |
|
|
|
GND |
|
|
|
|
|
|
||||||
LDQM |
|
|
|
15 |
40 |
|
|
|
NC |
|
|
|
|
|
|
||||||
WE |
|
|
|
16 |
39 |
|
|
|
UDQM |
|
|
|
|
|
|
||||||
CAS |
|
|
|
38 |
|
|
|
CLK |
||
|
|
|
17 |
|
|
|
||||
RAS |
|
|
|
18 |
37 |
|
|
|
CKE |
|
|
|
|
|
|
||||||
CS |
|
|
|
19 |
36 |
|
|
|
NC |
|
|
|
|
|
|
||||||
BA0 |
|
|
|
20 |
35 |
|
|
|
A11 |
|
|
|
|
|
|
|
|||||
BA1 |
|
|
|
21 |
34 |
|
|
|
A9 |
|
|
|
|
|
|
|
|||||
A10 |
|
|
|
22 |
33 |
|
|
|
A8 |
|
|
|
|
|
|
||||||
A0 |
|
|
|
23 |
32 |
|
|
|
A7 |
|
|
|
|
|
|
||||||
A1 |
|
|
|
24 |
31 |
|
|
|
A6 |
|
|
|
|
|
|
||||||
A2 |
|
|
|
30 |
|
|
|
A5 |
||
|
|
|
25 |
|
|
|
||||
|
|
|
29 |
|
|
|
|
|||
A3 |
|
|
|
26 |
|
|
|
A4 |
||
VCC |
|
|
|
27 |
28 |
|
|
|
GND |
|
|
|
|
|
|
|
PIN DESCRIPTIONS
A0-A11 |
Address Input |
BA0, BA1 |
Bank Select Address |
|
|
I/O0 to I/O15 |
Data I/O |
|
|
CLK |
System Clock Input |
|
|
CKE |
Clock Enable |
|
|
CS |
Chip Select |
|
|
RAS |
Row Address Strobe Command |
|
|
CAS |
Column Address Strobe Command |
|
|
WE |
Write Enable |
|
|
LDQM |
Lower Bye, Input/Output Mask |
|
|
UDQM |
Upper Bye, Input/Output Mask |
|
|
Vcc |
Power |
|
|
GND |
Ground |
|
|
VccQ |
Power Supply for I/O Pin |
|
|
GNDQ |
Ground for I/O Pin |
|
|
NC |
No Connection |
|
|
This document contains TARGET SPECIFICATION data. ISSI reserves the right to make changes to its products at any time without notice in order to improve design and supply the best possible product. We assume no responsibility for any errors which may appear in this publication. © Copyright 2001, Integrated Silicon Solution, Inc.
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
1 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
GENERAL DESCRIPTION
The 64Mb SDRAM is a high speed CMOS, dynamic random-access memory designed to operate in 3.3V memory systems containing 67,108,864 bits. Internally configured as a quad-bank DRAM with a synchronous interface. Each 16,777,216-bit bank is organized as 4,096 rows by 256 columns by 16 bits.
The 64Mb SDRAM includes an AUTO REFRESH MODE, and a power-saving, power-down mode. All signals are registered on the positive edge of the clock signal, CLK. All inputs and outputs are LVTTL compatible.
The 64Mb SDRAM has the ability to synchronously burst data at a high data rate with automatic column-address generation, the ability to interleave between internal banks to hide precharge time and the capability to randomly change column addresses on each clock cycle during burst access.
A self-timed row precharge initiated at the end of the burst sequence is available with the AUTO PRECHARGE
function enabled. Precharge one bank while accessing one of the other three banks will hide the precharge cycles and provide seamless, high-speed, random-access operation.
SDRAM read and write accesses are burst oriented starting at a selected location and continuing for a programmed number of locations in a programmed sequence. The registration of an ACTIVE command begins accesses, followed by a READ or WRITE command. The ACTIVE command in conjunction with address bits registered are used to select the bank and row to be accessed (BA0, BA1 select the bank; A0-A11 select the row). The READ or WRITE commands in conjunction with address bits registered are used to select the starting column location for the burst access.
Programmable READ or WRITE burst lengths consist of 1, 2, 4 and 8 locations or full page, with a burst terminate option.
FUNCTIONAL BLOCK DIAGRAM
CLK |
|
|
|
|
|
|
|
DQM |
|
|
CKE |
|
|
|
|
|
|
|
DATA IN |
|
|
CS |
COMMAND |
|
|
|
|
|
|
|
||
RAS |
DECODER |
|
|
|
|
|
BUFFER |
|
|
|
CAS |
|
& |
|
|
|
|
16 |
16 |
|
|
|
|
|
|
|
|
|
|
|
||
WE |
CLOCK |
MODE |
|
REFRESH |
|
|
I/O 0-15 |
|
||
A11 |
GENERATOR |
|
CONTROLLER |
|
|
|
||||
REGISTER |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11 |
|
SELF |
|
DATA OUT |
Vcc/VccQ |
|
|
|
|
|
|
|
REFRESH |
|
|
|
||
A10 |
|
|
|
|
|
|
BUFFER |
GND/GNDQ |
|
|
|
|
|
|
CONTROLLER |
|
|
|
|||
|
|
|
|
|
|
16 |
16 |
|
|
|
A9 |
|
|
|
|
|
|
|
|
|
|
A8 |
|
|
|
|
|
|
|
|
|
|
A7 |
|
|
|
|
REFRESH |
|
|
|
|
|
A6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
COUNTER |
|
|
|
|
|
|
A5 |
|
|
|
|
|
|
|
|
|
|
A4 |
|
|
|
|
|
|
4096 |
|
|
|
A3 |
|
|
|
|
|
|
4096 |
|
|
|
A2 |
|
|
|
|
|
|
4096 |
MEMORY CELL |
|
|
A1 |
|
|
|
|
|
|
4096 |
ARRAY |
|
|
|
|
|
|
|
11 |
|
|
|
||
A0 |
|
|
|
|
|
|
|
|
|
|
|
ROW |
|
MULTIPLEXER |
|
DECODERROW |
|
BANK 0 |
|
|
|
BA0 |
|
|
ROW |
|
|
|
||||
|
|
|
|
|
|
|||||
BA1 |
|
ADDRESS |
ADDRESS |
|
|
|
|
|||
|
11 |
LATCH |
|
BUFFER |
|
|
|
|
||
|
|
|
|
11 |
|
|
SENSE AMP I/O GATE |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
256K |
|
|
|
|
|
COLUMN |
|
|
|
|
(x 16) |
|
|
|
|
|
|
|
BANK CONTROL LOGIC |
|
|
|
|
|
|
|
|
ADDRESS LATCH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8 |
|
|
|
|
|
|
|
|
|
|
|
BURST COUNTER |
|
|
|
|
|
|
|
|
|
|
COLUMN |
|
|
|
|
COLUMN DECODER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ADDRESS BUFFER |
|
|
|
|
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
||||
|
|
|
|
|
|
|
|
TARGET SPECIFICATION |
Rev. C |
|
|
|
|
|
|
|
|
|
|
|
05/04/01 |
IS42S16400 |
|
ISSI® |
|
PIN FUNCTIONS |
|
|
|
|
|
|
|
Symbol |
Pin No. |
Type |
Function (In Detail) |
|
|
|
|
A0-A11 |
23 to 26 |
Input Pin |
Address Inputs: A0-A11 are sampled during the ACTIVE |
|
29 to 34 |
|
command (row-address A0-A11) and READ/WRITE command (A0-A7 |
|
22, 35 |
|
with A10 defining auto precharge) to select one location out of the memory array |
|
|
|
in the respective bank. A10 is sampled during a PRECHARGE command to |
|
|
|
determine if all banks are to be precharged (A10 HIGH) or bank selected by |
|
|
|
BA0, BA1 (LOW). The address inputs also provide the op-code during a LOAD |
|
|
|
MODE REGISTER command. |
|
|
|
|
BA0, BA1 |
20, 21 |
Input Pin |
Bank Select Address: BA0 and BA1 defines which bank the ACTIVE, READ, |
|
|
|
WRITE or PRECHARGE command is being applied. |
|
|
|
|
CAS |
17 |
Input Pin |
CAS, in conjunction with the RAS and WE, forms the device command. See the |
|
|
|
"Command Truth Table" for details on device commands. |
|
|
|
|
CKE |
37 |
Input Pin |
The CKE input determines whether the CLK input is enabled. The next rising edge |
|
|
|
of the CLK signal will be valid when is CKE HIGH and invalid when LOW. When |
|
|
|
CKE is LOW, the device will be in either power-down mode, clock suspend mode, |
|
|
|
or self refresh mode. CKE is an asynchronous input. |
|
|
|
|
CLK |
38 |
Input Pin |
CLK is the master clock input for this device. Except for CKE, all inputs to this |
|
|
|
device are acquired in synchronization with the rising edge of this pin. |
|
|
|
|
CS |
19 |
Input Pin |
The CS input determines whether command input is enabled within the device. |
|
|
|
Command input is enabled when CS is LOW, and disabled with CS is HIGH. The |
|
|
|
device remains in the previous state when CS is HIGH. |
|
|
|
|
I/O0 to |
2, 4, 5, 7, 8, 10, |
I/O Pin |
I/O0 to I/O15 are I/O pins. I/O through these pins can be controlled in byte units |
I/O15 |
11,13, 42, 44, 45, |
|
using the LDQM and UDQM pins. |
|
47, 48, 50, 51, 53 |
|
|
|
|
|
|
LDQM, |
15, 39 |
Input Pin |
LDQM and UDQM control the lower and upper bytes of the I/O buffers. In read |
UDQM |
|
|
mode, LDQM and UDQM control the output buffer. When LDQM or UDQM is |
|
|
|
LOW, the corresponding buffer byte is enabled, and when HIGH, disabled. The |
|
|
|
outputs go to the HIGH impedance state when LDQM/UDQM is HIGH. This |
|
|
|
function corresponds to OE in conventional DRAMs. In write mode, LDQM and |
|
|
|
UDQM control the input buffer. When LDQM or UDQM is LOW, the corresponding |
|
|
|
buffer byte is enabled, and data can be written to the device. When LDQM or |
|
|
|
UDQM is HIGH, input data is masked and cannot be written to the device. |
|
|
|
|
RAS |
18 |
Input Pin |
RAS, in conjunction with CAS and WE, forms the device command. See the |
|
|
|
"Command Truth Table" item for details on device commands. |
|
|
|
|
WE |
16 |
Input Pin |
WE, in conjunction with RAS and CAS, forms the device command. See the |
|
|
|
"Command Truth Table" item for details on device commands. |
|
|
|
|
VCCQ |
3, 9, 43, 49 |
Power Supply Pin |
VCCQ is the output buffer power supply. |
|
|
|
|
VCC |
1, 14, 27 |
Power Supply Pin |
VCC is the device internal power supply. |
|
|
|
|
GNDQ |
6, 12, 46, 52 |
Power Supply Pin |
GNDQ is the output buffer ground. |
|
|
|
|
GND |
28, 41, 54 |
Power Supply Pin |
GND is the device internal ground. |
|
|
|
|
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
3 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
FUNCTION (In Detail)
A0-A11 are address inputs sampled during the ACTIVE (row-address A0-A11) and READ/WRITE command (A0-A7 with A10 defining auto PRECHARGE). A10 is sampled during a PRECHARGE command to determine if all banks are to be PRECHARGED (A10 HIGH) or bank selected by BA0, BA1 (LOW). The address inputs also provide the op-code during a LOAD MODE REGISTER command.
Bank Select Address (BA0 and BA1) defines which bank the ACTIVE, READ, WRITE or PRECHARGE command is being applied.
CAS, in conjunction with the RAS and WE, forms the device command. See the “Command Truth Table” for details on device commands.
The CKE input determines whether the CLK input is enabled. The next rising edge of the CLK signal will be valid when is CKE HIGH and invalid when LOW. When CKE is LOW, the device will be in either power-down mode, CLOCK SUSPEND mode, or SELF-REFRESH mode. CKE is an asynchronous input.
CLK is the master clock input for this device. Except for CKE, all inputs to this device are acquired in synchronization with the rising edge of this pin.
The CS input determines whether command input is enabled within the device. Command input is enabled when CS is LOW, and disabled with CS is HIGH. The device remains in the previous state when CS is HIGH. I/ O0 to I/O15 are I/O pins. I/O through these pins can be controlled in byte units using the LDQM and UDQM pins.
LDQM and UDQM control the lower and upper bytes of the I/O buffers. In read mode, LDQM and UDQM control the output buffer. When LDQM or UDQM is LOW, the corresponding buffer byte is enabled, and when HIGH, disabled. The outputs go to the HIGH Impedance State when LDQM/UDQM is HIGH. This function corresponds to OE in conventional DRAMs. In write mode, LDQM and UDQM control the input buffer. When LDQM or UDQM is LOW, the corresponding buffer byte is enabled, and data can be written to the device. When LDQM or UDQM is HIGH, input data is masked and cannot be written to the device.
RAS, in conjunction with CAS and WE , forms the device command. See the “Command Truth Table” item for details on device commands.
WE , in conjunction with RAS and CAS , forms the device command. See the “Command Truth Table” item for details on device commands.
VCCQ is the output buffer power supply.
VCC is the device internal power supply.
GNDQ is the output buffer ground.
GND is the device internal ground.
READ
The READ command selects the bank from BA0, BA1 inputs and starts a burst read access to an active row. Inputs A0-A7 provides the starting column location. When A10 is HIGH, this command functions as an AUTO PRECHARGE command. When the auto precharge is selected, the row being accessed will be precharged at the end of the READ burst. The row will remain open for subsequent accesses when AUTO PRECHARGE is not selected. DQ’s read data is subject to the logic level on the DQM inputs two clocks earlier. When a given DQM signal was registered HIGH, the corresponding DQ’s will be High-Z two clocks later. DQ’s will provide valid data when the DQM signal was registered LOW.
WRITE
A burst write access to an active row is initiated with the WRITE command. BA0, BA1 inputs selects the bank, and the starting column location is provided by inputs A0-A7. Whether or not AUTO-PRECHARGE is used is determined by A10.
The row being accessed will be precharged at the end of the WRITE burst, if AUTO PRECHARGE is selected. If AUTO PRECHARGE is not selected, the row will remain open for subsequent accesses.
A memory array is written with corresponding input data on DQ’s and DQM input logic level appearing at the same time. Data will be written to memory when DQM signal is LOW. When DQM is HIGH, the corresponding data inputs will be ignored, and a WRITE will not be executed to that byte/column location.
PRECHARGE
The PRECHARGE command is used to deactivate the open row in a particular bank or the open row in all banks. BA0, BA1 can be used to select which bank is precharged or they are treated as “Don’t Care”. A10 determined whether one or all banks are precharged. After executing this command, the next command for the selected banks(s) is executed after passage of the period tRP, which is the period required for bank precharging. Once a bank has been precharged, it is in the idle state and must be activated prior to any READ or WRITE commands being issued to that bank.
AUTO PRECHARGE
The AUTO PRECHARGE function ensures that the precharge is initiated at the earliest valid stage within a burst. This function allows for individual-bank precharge without requiring an explicit command. A10 to enables the AUTO PRECHARGE function in conjunction with a specific READ or WRITE command. For each individual READ or WRITE command, auto precharge is either
4 Integrated Silicon Solution, Inc. — 1-800-379-4774
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
enabled or disabled. AUTO PRECHARGE does not apply except in full-page burst mode. Upon completion of the READ or WRITE burst, a precharge of the bank/row that is addressed is automatically performed.
AUTO REFRESH COMMAND
This command executes the AUTO REFRESH operation. The row address and bank to be refreshed are automatically generated during this operation. The stipulated period (tRC) is required for a single refresh operation, and no other commands can be executed during this period. This command is executed at least 4096 times every 64ms. During an AUTO REFRESH command, address bits are “Don’t Care”. This command corresponds to CBR Auto-refresh.
SELF REFRESH
During the SELF REFRESH operation, the row address to be refreshed, the bank, and the refresh interval are generated automatically internally. SELF REFRESH can be used to retain data in the SDRAM without external clocking, even if the rest of the system is powered down. The SELF REFRESH operation is started by dropping the CKE pin from HIGH to LOW. During the SELF REFRESH operation all other inputs to the SDRAM become “Don’t Care”.The device must remain in self refresh mode for a minimum period equal to tRAS or may remain in self refresh mode for an indefinite period beyond that.The SELFREFRESH operation continues as long as the CKE pin remains LOW and there is no need for external control of any other pins.The next command cannot be executed until the device internal recovery period (tRC) has elapsed. Once CKE goes HIGH, the NOP command must be issued (minimum of two clocks) to provide time for the completion of any internal refresh in progress. After the self-refresh, since it is impossible to determine the address of the last row to be refreshed, an AUTO-REFRESH should immediately be performed for all addresses.
BURST TERMINATE
The BURST TERMINATE command forcibly terminates the burst read and write operations by truncating either fixed-length or full-page bursts and the most recently registered READ or WRITE command prior to the BURST TERMINATE.
COMMAND INHIBIT
COMMAND INHIBIT prevents new commands from being executed. Operations in progress are not affected, apart from whether the CLK signal is enabled
NO OPERATION
When CS is low, the NOP command prevents unwanted commands from being registered during idle or wait states.
LOAD MODE REGISTER
During the LOAD MODE REGSITER command the mode register is loaded from A0-A11. This command can only be issued when all banks are idle.
ACTIVE COMMAND
When the ACTIVE COMMAND is activated, BA0, BA1 inputs selects a bank to be accessed, and the address inputs on A0-A11 selects the row. Until a PRECHARGE command is issued to the bank, the row remains open for accesses.
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
5 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
|
|
|
|
|
ISSI® |
|
TRUTH TABLE – COMMANDS AND DQM OPERATION(1) |
|
|
|
|
|||
|
|
|
|
|
|
|
|
FUNCTION |
CS |
RAS |
CAS |
WE |
DQM |
ADDR |
DQs |
|
|
|
|
|
|
|
|
COMMAND INHIBIT (NOP) |
H |
X |
X |
X |
X |
X |
X |
|
|
|
|
|
|
|
|
NO OPERATION (NOP) |
L |
H |
H |
H |
X |
X |
X |
|
|
|
|
|
|
|
|
ACTIVE (Select bank and activate row)(3) |
L |
L |
H |
H |
X |
Bank/Row |
X |
READ (Select bank/column, start READ burst)(4) |
L |
H |
L |
H |
L/H(8) |
Bank/Col |
X |
|
|
|
|
|
|
|
|
WRITE (Select bank/column, start WRITE burst)(4) |
L |
H |
L |
L |
L/H(8) |
Bank/Col |
Valid |
|
|
|
|
|
|
|
|
BURST TERMINATE |
L |
H |
H |
L |
X |
X |
Active |
|
|
|
|
|
|
|
|
PRECHARGE (Deactivate row in bank or banks)(5) |
L |
L |
H |
L |
X |
Code |
X |
|
|
|
|
|
|
|
|
AUTO REFRESH or SELF REFRESH(6,7) |
L |
L |
L |
H |
X |
X |
X |
(Enter self refresh mode) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LOAD MODE REGISTER(2) |
L |
L |
L |
L |
X |
Op-Code |
X |
|
|
|
|
|
|
|
|
Write Enable/Output Enable(8) |
— |
— |
— |
— |
L |
— |
Active |
|
|
|
|
|
|
|
|
Write Inhibit/Output High-Z(8) |
— |
— |
— |
— |
H |
— |
High-Z |
|
|
|
|
|
|
|
|
NOTES:
1.CKE is HIGH for all commands except SELF REFRESH.
2.A0-A11 define the op-code written to the mode register.
3.A0-A11 provide row address, and BA0, BA1 determine which bank is made active.
4.A0-A7 (x16) provide column address; A10 HIGH enables the auto precharge feature (nonpersistent), while A10 LOW disables auto precharge; BA0, BA1 determine which bank is being read from or written to.
5.A10 LOW: BA0, BA1 determine the bank being precharged. A10 HIGH: All banks precharged and BA0, BA1 are “Don’t Care.”
6.AUTO REFRESH if CKE is HIGH, SELF REFRESH if CKE is LOW.
7.Internal refresh counter controls row addressing; all inputs and I/Os are “Don’t Care” except for CKE.
8.Activates or deactivates the DQs during WRITEs (zero-clock delay) and READs (two-clock delay).
6 Integrated Silicon Solution, Inc. — 1-800-379-4774
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
|
|
ISSI® |
|
TRUTH TABLE – CKE (1-4) |
|
|
|
|
|
|
|
|
|
CURRENT STATE |
COMMANDn |
ACTIONn |
CKEn-1 |
CKEn |
|
|
|
|
|
Power-Down |
X |
Maintain Power-Down |
L |
L |
|
|
|
|
|
Self Refresh |
X |
Maintain Self Refresh |
L |
L |
|
|
|
|
|
Clock Suspend |
X |
Maintain Clock Suspend |
L |
L |
|
|
|
|
|
Power-Down(5) |
COMMAND INHIBIT or NOP |
Exit Power-Down |
L |
H |
|
|
|
|
|
Self Refresh(6) |
COMMAND INHIBIT or NOP |
Exit Self Refresh |
L |
H |
|
|
|
|
|
Clock Suspend(7) |
X |
Exit Clock Suspend |
L |
H |
|
|
|
|
|
All Banks Idle |
COMMAND INHIBIT or NOP |
Power-Down Entry |
H |
L |
|
|
|
|
|
All Banks Idle |
AUTO REFRESH |
Self Refresh Entry |
H |
L |
|
|
|
|
|
Reading or Writing |
VALID |
Clock Suspend Entry |
H |
L |
|
|
|
|
|
|
SeeTRUTHTABLE–CURRENTSTATEBANKn,COMMANDTOBANKn |
H |
H |
|
|
|
|
|
|
NOTES:
1.CKEn is the logic state of CKE at clock edge n; CKEn-1 was the state of CKE at the previous clock edge.
2.Current state is the state of the SDRAM immediately prior to clock edge n.
3.COMMANDn is the command registered at clock edge n, and ACTONn is a result of COMMANDn.
4.All states and sequences not shown are illegal or reserved.
5.Exiting power-down at clock edge n will put the device in the all banks idle state in time for clock edge n+1 (provided that tCKS is met).
6.Exiting self refresh at clock edge n will put the device in all banks idle state once tXSR is met. COMMAND INHIBIT or NOP commands should be issued on clock edges occurring during the tXSR period. A minimum of two NOP commands must be sent during tXSR period.
7.After exiting clock suspend at clock edge n, the device will resume operation and recognize the next command at clock edge n+1.
TRUTH TABLE – CURRENT STATE BANK n, COMMAND TO BANK n (1-6)
CURRENT STATE |
COMMAND (ACTION) |
CS |
RAS |
CAS |
WE |
|
|
|
|
|
|
Any |
COMMAND INHIBIT (NOP/Continue previous operation) |
H |
X |
X |
X |
|
|
|
|
|
|
|
NO OPERATION (NOP/Continue previous operation) |
L |
H |
H |
H |
|
|
|
|
|
|
Idle |
ACTIVE (Select and activate row) |
L |
L |
H |
H |
|
|
|
|
|
|
|
AUTO REFRESH(7) |
L |
L |
L |
H |
|
|
|
|
|
|
|
LOAD MODE REGISTER(7) |
L |
L |
L |
L |
|
PRECHARGE(11) |
L |
L |
H |
L |
|
|
|
|
|
|
Row Active |
READ (Select column and start READ burst)(10) |
L |
H |
L |
H |
|
|
|
|
|
|
|
WRITE (Select column and start WRITE burst)(10) |
L |
H |
L |
L |
|
PRECHARGE (Deactivate row in bank or banks)(8) |
L |
L |
H |
L |
|
|
|
|
|
|
Read |
READ (Select column and start new READ burst)(10) |
L |
H |
L |
H |
|
|
|
|
|
|
(Auto |
WRITE (Select column and start WRITE burst)(10) |
L |
H |
L |
L |
Precharge |
PRECHARGE (Truncate READ burst, start PRECHARGE)(8) |
L |
L |
H |
L |
|
|
|
|
|
|
Disabled) |
BURST TERMINATE(9) |
L |
H |
H |
L |
|
|
|
|
|
|
Write |
READ (Select column and start READ burst)(10) |
L |
H |
L |
H |
(Auto |
WRITE (Select column and start new WRITE burst)(10) |
L |
H |
L |
L |
|
|
|
|
|
|
Precharge |
PRECHARGE (Truncate WRITE burst, start PRECHARGE)(8) |
L |
L |
H |
L |
|
|
|
|
|
|
Disabled) |
BURST TERMINATE(9) |
L |
H |
H |
L |
|
|
|
|
|
|
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
|
|
|
7 |
|
TARGET SPECIFICATION |
Rev. C |
|
|
|
|
05/04/01 |
|
|
|
|
|
IS42S16400 |
ISSI® |
NOTE:
1.This table applies when CKE n-1 was HIGH and CKE n is HIGH (see Truth Table - CKE) and after tXSR has been met (if the previous state was SELF REFRESH).
2.This table is bank-specific, except where noted; i.e., the current state is for a specific bank and the commands shown are those allowed to be issued to that bank when in that state. Exceptions are covered in the notes below.
3.Current state definitions:
Idle: The bank has been precharged, and tRP has been met.
Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress.
Read: A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. Write: A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated.
4. The following states must not be interrupted by a command issued to the same bank. COMMAND INHIBIT or NOP commands, or allowable commands to the other bank should be issued on any clock edge occurring during these states. Allowable commands to the other bank are determined by its current state and CURRENT STATE BANK n truth tables.
Precharging: Starts with registration of a PRECHARGE command and ends when tRP is met. Once tRP is met, the bank will be in the idle state.
Row Activating: Starts with registration of an ACTIVE command and ends when tRCD is met. Once tRCD is met, the bank will be in the row active state.
Read w/Auto
Precharge Enabled: Starts with registration of a READ command with auto precharge enabled and ends when tRP has been met. Once tRP is met, the bank will be in the idle state.
Write w/Auto
Precharge Enabled: Starts with registration of a WRITE command with auto precharge enabled and ends when tRP has been met. Once tRP is met, the bank will be in the idle state.
5.The following states must not be interrupted by any executable command; COMMAND INHIBIT or NOP commands must be applied on each positive clock edge during these states.
Refreshing: Starts with registration of an AUTO REFRESH command and ends when tRC is met. Once tRC is met, the
SDRAM will be in the all banks idle state.
Accessing Mode
Register: Starts with registration of a LOAD MODE REGISTER command and ends when tMRD has been met. Once tMRD is met, the SDRAM will be in the all banks idle state.
Precharging All: Starts with registration of a PRECHARGE ALL command and ends when tRP is met. Once tRP is met, all banks will be in the idle state.
6.All states and sequences not shown are illegal or reserved.
7.Not bank-specific; requires that all banks are idle.
8.May or may not be bank-specific; if all banks are to be precharged, all must be in a valid state for precharging.
9.Not bank-specific; BURST TERMINATE affects the most recent READ or WRITE burst, regardless of bank.
10.READs or WRITEs listed in the Command (Action) column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled.
11.Does not affect the state of the bank and acts as a NOP to that bank.
8 Integrated Silicon Solution, Inc. — 1-800-379-4774
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
TRUTH TABLE – CURRENT STATE BANK n, COMMAND TO BANK m (1-6)
CURRENT STATE |
COMMAND (ACTION) |
CS |
RAS |
CAS |
WE |
|
|
|
|
|
|
Any |
COMMAND INHIBIT (NOP/Continue previous operation) |
H |
X |
X |
X |
|
|
|
|
|
|
|
NO OPERATION (NOP/Continue previous operation) |
L |
H |
H |
H |
|
|
|
|
|
|
Idle |
Any Command Otherwise Allowed to Bank m |
X |
X |
X |
X |
|
|
|
|
|
|
Row |
ACTIVE (Select and activate row) |
L |
L |
H |
H |
|
|
|
|
|
|
Activating, |
READ (Select column and start READ burst)(7) |
L |
H |
L |
H |
Active, or |
WRITE (Select column and start WRITE burst)(7) |
L |
H |
L |
L |
|
|
|
|
|
|
Precharging |
PRECHARGE |
L |
L |
H |
L |
|
|
|
|
|
|
Read |
ACTIVE (Select and activate row) |
L |
L |
H |
H |
|
|
|
|
|
|
(Auto |
READ (Select column and start new READ burst)(7,10) |
L |
H |
L |
H |
|
|
|
|
|
|
Precharge |
WRITE (Select column and start WRITE burst)(7,11) |
L |
H |
L |
L |
|
|
|
|
|
|
Disabled) |
PRECHARGE(9) |
L |
L |
H |
L |
Write |
ACTIVE (Select and activate row) |
L |
L |
H |
H |
|
|
|
|
|
|
(Auto |
READ (Select column and start READ burst)(7,12) |
L |
H |
L |
H |
|
|
|
|
|
|
Precharge |
WRITE (Select column and start new WRITE burst)(7,13) |
L |
H |
L |
L |
Disabled) |
PRECHARGE(9) |
L |
L |
H |
L |
|
|
|
|
|
|
Read |
ACTIVE (Select and activate row) |
L |
L |
H |
H |
|
|
|
|
|
|
(With Auto |
READ (Select column and start new READ burst)(7,8,14) |
L |
H |
L |
H |
Precharge) |
WRITE (Select column and start WRITE burst)(7,8,15) |
L |
H |
L |
L |
|
|
|
|
|
|
|
PRECHARGE(9) |
L |
L |
H |
L |
|
|
|
|
|
|
Write |
ACTIVE (Select and activate row) |
L |
L |
H |
H |
|
|
|
|
|
|
(With Auto |
READ (Select column and start READ burst)(7,8,16) |
L |
H |
L |
H |
|
|
|
|
|
|
Precharge) |
WRITE (Select column and start new WRITE burst)(7,8,17) |
L |
H |
L |
L |
|
|
|
|
|
|
|
PRECHARGE(9) |
L |
L |
H |
L |
NOTE:
1.This table applies when CKE n-1 was HIGH and CKE n is HIGH (Truth Table - CKE) and after tXSR has been met (if the previous state was self refresh).
2.This table describes alternate bank operation, except where noted; i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below.
3.Current state definitions:
Idle: The bank has been precharged, and tRP has been met.
Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress.
Read: A READ burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated. Write: A WRITE burst has been initiated, with auto precharge disabled, and has not yet terminated or been terminated.
Read w/Auto
Precharge Enabled: Starts with registration of a READ command with auto precharge enabled, and ends when tRP has been met. Once tRP is met, the bank will be in the idle state.
Write w/Auto
Precharge Enabled: Starts with registration of a WRITE command with auto precharge enabled, and ends when tRP has been met. Once tRP is met, the bank will be in the idle state.
4.AUTO REFRESH, SELF REFRESH and LOAD MODE REGISTER commands may only be issued when all banks are idle.
5.A BURST TERMINATE command cannot be issued to another bank; it applies to the bank represented by the current state only.
6.All states and sequences not shown are illegal or reserved.
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
9 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
7.READs or WRITEs to bank m listed in the Command (Action) column include READs or WRITEs with auto precharge enabled and READs or WRITEs with auto precharge disabled.
8.CONCURRENT AUTO PRECHARGE: Bank n will initiate the AUTO PRECHARGE command when its burst has been interrupted by bank m’s burst.
9.Burst in bank n continues as initiated.
10.For a READ without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CAS latency later (Consecutive READ Bursts).
11.For a READ without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered (READ to WRITE). DQM should be used one clock prior to the WRITE command to prevent bus contention.
12.For a WRITE without auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered (WRITE to READ), with the data-out appearing CAS latency later. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m.
13.For a WRITE without auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered (WRITE to WRITE). The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m.
14.For a READ with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the READ on bank n, CAS latency later. The PRECHARGE to bank n will begin when the READ to bank m is registered (Fig CAP 1).
15.For a READ with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the READ on bank n when registered. DQM should be used two clocks prior to the WRITE command to prevent bus contention. The PRECHARGE to bank n will begin when the WRITE to bank m is registered (Fig CAP 2).
16.For a WRITE with auto precharge interrupted by a READ (with or without auto precharge), the READ to bank m will interrupt the WRITE on bank n when registered, with the data-out appearing CAS latency later. The PRECHARGE to bank n will begin after tWR is met, where tWR begins when the READ to bank m is registered. The last valid WRITE to bank n will be data-in registered one clock prior to the READ to bank m (Fig CAP 3).
17.For a WRITE with auto precharge interrupted by a WRITE (with or without auto precharge), the WRITE to bank m will interrupt the WRITE on bank n when registered. The PRECHARGE to bank n will begin after tWR is met, where t WR begins when the WRITE to bank m is registered. The last valid WRITE to bank n will be data registered one clock prior to the WRITE to bank m (Fig CAP 4).
10 Integrated Silicon Solution, Inc. — 1-800-379-4774
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
|
|
|
|
ISSI® |
ABSOLUTE MAXIMUM RATINGS(1) |
|
|
|
|
|
|
|
|
|
|
|
Symbol |
Parameters |
|
Rating |
Unit |
|
|
|
|
|
|
|
VCC MAX |
Maximum Supply Voltage |
|
–1.0 to +4.6 |
V |
|
VCCQ MAX |
Maximum Supply Voltage for Output Buffer |
–1.0 to +4.6 |
V |
||
|
|
|
|
|
|
VIN |
Input Voltage |
|
–1.0 to +4.6 |
V |
|
|
|
|
|
|
|
VOUT |
Output Voltage |
|
–1.0 to +4.6 |
V |
|
PD MAX |
Allowable Power Dissipation |
|
1 |
W |
|
|
|
|
|
|
|
ICS |
Output Shorted Current |
|
50 |
mA |
|
|
|
|
|
|
|
TOPR |
Operating Temperature |
Com. |
0 to +70 |
°C |
|
|
|
Ind. |
–40 to +85 |
|
|
TSTG |
Storage Temperature |
|
–55 to +150 |
°C |
|
|
|
|
|
|
|
DC RECOMMENDED OPERATING CONDITIONS(2) (At TA = 0 to +70°C)
Symbol |
Parameter |
Min. |
Typ. |
Max. |
Unit |
VCC, VCCQ |
Supply Voltage |
3.0 |
3.3 |
3.6 |
V |
|
|
|
|
|
|
VIH |
Input High Voltage |
2.0 |
— |
VCC + 0.3 |
V |
|
|
|
|
|
|
VIL |
Input Low Voltage |
-0.3 |
— |
+0.8 |
V |
|
|
|
|
|
|
CAPACITANCE CHARACTERISTICS(1,2) (At TA = 0 to +25°C, Vcc = VccQ = 3.3 ± 0.3V, f = 1 MHz)
Symbol |
Parameter |
Typ. |
Max. |
Unit |
CIN1 |
Input Capacitance: A0-A11, BA0, BA1 |
— |
4 |
pF |
|
|
|
|
|
CIN2 |
Input Capacitance: (CLK, CKE, CS, RAS, CAS, WE, LDQM, UDQM) |
— |
4 |
pF |
|
|
|
|
|
CI/O |
Data Input/Output Capacitance: I/O0-I/O15 |
— |
5 |
pF |
|
|
|
|
|
Notes:
1.Stress greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability.
2.All voltages are referenced to GND.
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
11 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
|
|
|
|
|
ISSI® |
||
DC ELECTRICAL CHARACTERISTICS (Recommended Operation Conditions unless otherwise noted.) |
|
|||||||
|
|
|
|
|
|
|
|
|
Symbol |
Parameter |
Test Condition |
|
|
Speed |
Min. |
Max. |
Unit |
IIL |
Input Leakage Current |
0V ≤ VIN ≤ VCC, with pins other than |
|
|
–5 |
5 |
µA |
|
|
|
the tested pin at 0V |
|
|
|
|
|
|
IOL |
Output Leakage Current |
Output is disabled, 0V ≤ VOUT ≤ VCC |
|
|
–5 |
5 |
µA |
|
VOH |
Output High Voltage Level |
IOUT = –2 mA |
|
|
|
2.4 |
— |
V |
VOL |
Output Low Voltage Level |
IOUT = +2 mA |
|
|
|
— |
0.4 |
V |
ICC1 |
Operating Current(1,2) |
One Bank Operation, |
CAS latency = 3 |
|
-6 |
— |
140 |
mA |
|
|
Burst Length=1 |
|
Com. |
-7 |
— |
125 |
mA |
|
|
tRC ≥ tRC (min.) |
|
Ind. |
-7 |
— |
145 |
mA |
|
|
IOUT = 0mA |
|
Com. |
-10 |
— |
110 |
mA |
|
|
|
|
Ind. |
-10 |
— |
125 |
mA |
ICC2P |
Precharge Standby Current |
CKE ≤ VIL (MAX) |
tCK = tCK (MIN) |
Com. |
— |
— |
3 |
mA |
|
|
|
tCK = ∞ |
Ind. |
— |
— |
4 |
mA |
ICC2PS |
(In Power-Down Mode) |
|
Com. |
— |
— |
2 |
mA |
|
|
|
|
|
Ind. |
— |
— |
3 |
mA |
ICC2N |
Precharge Standby Current |
CKE ≥ VIH (MIN) |
tCK = tCK (MIN) |
|
— |
— |
30 |
mA |
ICC2NS |
(In Non Power-Down Mode) |
|
tCK = ∞ |
Com. |
— |
— |
10 |
mA |
|
|
|
|
Ind. |
— |
— |
15 |
mA |
ICC3P |
Active Standby Current |
CKE ≤ VIL (MAX) |
tCK = tCK (MIN) |
Com. |
— |
— |
3 |
mA |
|
|
|
Ind. |
Ind. |
— |
— |
7 |
mA |
ICC3PS |
(In Power-Down Mode) |
|
tCK = ∞ |
Com. |
— |
— |
3 |
mA |
|
|
|
|
Ind. |
— |
— |
5 |
mA |
ICC3N |
Active Standby Current |
CKE ≥ VIH (MIN) |
tCK = tCK (MIN) |
|
— |
— |
40 |
mA |
ICC3NS |
(In Non Power-Down Mode) |
|
tCK = ∞ |
Com. |
— |
— |
20 |
mA |
|
|
|
|
Ind. |
— |
— |
25 |
mA |
ICC4 |
Operating Current |
tCK = tCK (MIN) |
CAS latency = 3 |
|
-6 |
— |
130 |
mA |
|
(In Burst Mode)(1) |
IOUT = 0mA |
|
Com. |
-7 |
— |
100 |
mA |
|
|
|
|
Ind. |
-7 |
— |
120 |
mA |
|
|
|
|
Com. |
-10 |
— |
80 |
mA |
|
|
|
|
Ind. |
-10 |
— |
100 |
mA |
|
|
|
CAS latency = 2 |
|
-6 |
— |
130 |
mA |
|
|
|
|
Com. |
-7 |
— |
100 |
mA |
|
|
|
|
Ind. |
-7 |
— |
120 |
mA |
|
|
|
|
Com. |
-10 |
— |
80 |
mA |
|
|
|
|
Ind. |
-10 |
— |
100 |
mA |
ICC5 |
Auto-Refresh Current |
tRC = tRC (MIN) |
CAS latency = 3 |
|
-6 |
— |
150 |
mA |
|
|
|
|
Com. |
-7 |
— |
130 |
mA |
|
|
|
|
Ind. |
-7 |
— |
150 |
mA |
|
|
|
|
Com. |
-10 |
— |
110 |
mA |
|
|
|
|
Ind. |
-10 |
— |
130 |
mA |
|
|
|
CAS latency = 2 |
|
-6 |
— |
130 |
mA |
|
|
|
|
Com. |
-7 |
— |
100 |
mA |
|
|
|
|
Ind. |
-7 |
— |
120 |
mA |
|
|
|
|
Com. |
-10 |
— |
80 |
mA |
|
|
|
|
Ind. |
-10 |
— |
100 |
mA |
ICC6 |
Self-Refresh Current |
CKE ≤ 0.2V |
|
|
— |
— |
1 |
mA |
Notes:
1.These are the values at the minimum cycle time. Since the currents are transient, these values decrease as the cycle time increases. Also note that a bypass capacitor of at least 0.01 µF should be inserted between Vcc and GND for each memory chip to suppress power supply voltage noise (voltage drops) due to these transient currents.
2.Icc1 and Icc4 depend on the output load. The maximum values for Icc1 and Icc4 are obtained with the output open state.
12 Integrated Silicon Solution, Inc. — 1-800-379-4774
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
|
|
|
|
|
|
ISSI® |
||
AC ELECTRICAL CHARACTERISTICS (1,2,3) |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
-6 |
|
-7 |
|
-10 |
|
|
Symbol |
Parameter |
|
Min. |
Max. |
Min. |
Max. |
Min. |
Max |
Units |
|
|
|
|
|
|
|
|
|
|
tCK3 |
Clock Cycle Time |
CAS Latency = 3 |
6 |
— |
7 |
— |
10 |
— |
ns |
tCK2 |
|
CAS Latency = 2 |
8 |
— |
10 |
— |
10 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tAC3 |
Access Time From CLK(4) |
CAS Latency = 3 |
— |
5.5 |
— |
6 |
— |
7 |
ns |
tAC2 |
|
CAS Latency = 2 |
— |
6 |
— |
6 |
— |
9 |
ns |
|
|
|
|
|
|
|
|
|
|
tCHI |
CLK HIGH Level Width |
|
2 |
— |
2.5 |
— |
3.5 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tCL |
CLK LOW Level Width |
|
2 |
— |
2.5 |
— |
3.5 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tOH3 |
Output Data Hold Time |
CAS Latency = 3 |
2.5 |
— |
2.5 |
— |
2.5 |
— |
ns |
tOH2 |
|
CAS Latency = 2 |
2.5 |
— |
2.5 |
— |
2.5 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tLZ |
Output LOW Impedance Time |
|
0 |
— |
0 |
— |
0 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tHZ3 |
Output HIGH Impedance Time(5) |
CAS Latency = 3 |
— |
5.5 |
— |
6 |
— |
7 |
ns |
tHZ2 |
|
CAS Latency = 2 |
— |
6 |
— |
6 |
— |
9 |
ns |
|
|
|
|
|
|
|
|
|
|
tDS |
Input Data Setup Time |
|
1.5 |
— |
1.5 |
— |
2.0 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tDH |
Input Data Hold Time |
|
0.8 |
— |
0.8 |
— |
1 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tAS |
Address Setup Time |
|
1.5 |
— |
1.5 |
— |
2.0 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tAH |
Address Hold Time |
|
0.8 |
— |
0.8 |
— |
1 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tCKS |
CKE Setup Time |
|
1.5 |
— |
1.5 |
— |
2.0 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tCKH |
CKE Hold Time |
|
0.8 |
— |
0.8 |
— |
1 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tCKA |
CKE to CLK Recovery Delay Time |
1CLK+3 |
— |
1CLK+3 |
— |
1CLK+3 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
|
tCS |
Command Setup Time (CS, RAS, CAS, WE, DQM) |
1.5 |
— |
1.5 |
— |
2.0 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
|
tCH |
Command Hold Time (CS, RAS, CAS, WE, DQM) |
0.8 |
— |
0.8 |
— |
1 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
|
tRC |
Command Period (REF to REF / ACT to ACT) |
60 |
— |
63 |
— |
70 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
|
tRAS |
Command Period (ACT to PRE) |
|
35 |
120,000 |
37 |
120,000 |
44 |
120,000 |
ns |
|
|
|
|
|
|
|
|
|
|
tRP |
Command Period (PRE to ACT) |
|
15 |
— |
15 |
— |
18 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tRCD |
Active Command To Read / Write Command Delay Time |
15 |
— |
15 |
— |
18 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
|
tRRD |
Command Period (ACT [0] to ACT[1]) |
14 |
— |
14 |
— |
15 |
— |
ns |
|
|
|
|
|
|
|
|
|
|
|
tDPL3 |
Input Data To Precharge |
CAS Latency = 3 |
2CLK |
— |
2CLK |
— |
2CLK |
— |
ns |
|
Command Delay time |
|
|
|
|
|
|
|
|
tDPL2 |
|
CAS Latency = 2 |
2CLK |
— |
2CLK |
— |
2CLK |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tDAL3 |
Input Data To Active / Refresh |
CAS Latency = 3 |
2CLK+tRP |
— |
2CLK+tRP |
— |
2CLK+tRP |
— |
ns |
|
Command Delay time (During Auto-Precharge) |
|
|
|
|
|
|
|
|
tDAL2 |
|
CAS Latency = 2 |
2CLK+tRP |
— |
2CLK+tRP |
— |
2CLK+tRP |
— |
ns |
|
|
|
|
|
|
|
|
|
|
tT |
|
Transition Time |
1 |
10 |
1 |
10 |
1 |
10 |
ns |
|
|
|
|
|
|
|
|
|
|
tREF |
Refresh Cycle Time (4096) |
|
— |
64 |
— |
64 |
— |
64 |
ms |
|
|
|
|
|
|
|
|
|
|
Notes:
1.When power is first applied, memory operation should be started 100 µs after Vcc and VccQ reach their stipulated voltages. Also note that the power-on sequence must be executed before starting memory operation.
2.Measured with tT = 1 ns.
3.The reference level is 1.4 V when measuring input signal timing. Rise and fall times are measured between VIH (min.) and VIL (max.).
4.Access time is measured at 1.4V with the load shown in the figure below.
5.The time tHZ (max.) is defined as the time required for the output voltage to transition by ± 200 mV from VOH (min.) or VOL (max.) when the output is in the high impedance state.
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
13 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
|
|
|
ISSI® |
|
OPERATING FREQUENCY / LATENCY RELATIONSHIPS |
|
|
|
|
|
|
|
|
|
|
|
SYMBOL |
PARAMETER |
-6 |
-7 |
-10. |
UNITS |
|
|
|
|
|
|
— |
Clock Cycle Time |
6 |
7 |
10 |
ns |
|
|
|
|
|
|
— |
Operating Frequency |
166 |
133 |
100 |
MHz |
|
|
|
|
|
|
tCCD |
READ/WRITE command to READ/WRITE command |
1 |
1 |
1 |
cycle |
|
|
|
|
|
|
tCKED |
CKE to clock disable or power-down entry mode |
1 |
1 |
1 |
cycle |
|
|
|
|
|
|
tPED |
CKE to clock enable or power-down exit setup mode |
1 |
1 |
1 |
cycle |
|
|
|
|
|
|
tDQD |
DQM to input data delay |
0 |
0 |
0 |
cycle |
|
|
|
|
|
|
tDQM |
DQM to data mask during WRITEs |
0 |
0 |
0 |
cycle |
|
|
|
|
|
|
tDQZ |
DQM to data high-impedance during READs |
2 |
2 |
2 |
cycle |
|
|
|
|
|
|
tDWD |
WRITE command to input data delay |
0 |
0 |
0 |
cycle |
|
|
|
|
|
|
tDAL |
Data-in to ACTIVE command |
5 |
5 |
4 |
cycle |
|
|
|
|
|
|
tDPL |
Data-in to PRECHARGE command |
2 |
2 |
2 |
cycle |
|
|
|
|
|
|
tBDL |
Last data-in to burst STOP command |
1 |
1 |
1 |
cycle |
|
|
|
|
|
|
tCDL |
Last data-in to new READ/WRITE command |
1 |
1 |
1 |
cycle |
|
|
|
|
|
|
tRDL |
Last data-in to PRECHARGE command |
2 |
2 |
2 |
cycle |
|
|
|
|
|
|
tMRD |
LOAD MODE REGISTER command |
2 |
2 |
2 |
cycle |
|
to ACTIVE or REFRESH command |
|
|
|
|
|
|
|
|
|
|
tROH |
Data-out to high-impedance from |
CL = 3 |
3 |
3 |
3 |
cycle |
|
|
|
|
|
|
PRECHARGE command |
CL = 2 |
2 |
2 |
2 |
|
|
|
|
|
|
AC TEST CONDITIONS (Input/Output Reference Level: 1.4V)
Input Load |
Output Load |
|
|
|
tCK |
|
|
|
tCHI |
tCL |
|
|
2.0V |
|
|
|
CLK |
1.4V |
|
|
50 Ω |
|
0.8V |
|
|
|
|
|
I/O |
+1.4V |
|
|
tCS |
tCH |
||
|
|
|
||
|
2.0V |
|
|
50 pF |
INPUT |
1.4V |
|
|
|
|
|
|
||
|
0.8V |
|
tAC |
|
|
tOH |
|
|
|
|
|
|
|
|
OUTPUT |
|
1.4V |
1.4V |
|
14 |
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
FUNCTIONAL DESCRIPTION
The 64Mb SDRAMs (1 Meg x 16 x 4 banks) are quad-bank DRAMs which operate at 3.3V and include a synchronous interface (all signals are registered on the positive edge of the clock signal, CLK). Each of the 16,777,216-bit banks is organized as 4,096 rows by 256 columns by 16 bits.
Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an ACTIVE command which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed (BA0 and BA1 select the bank, A0-A11 select the row). The address bits (A0-A7) registered coincident with the READ or WRITE command are used to select the starting column location for the burst access.
Prior to normal operation, the SDRAM must be initialized. The following sections provide detailed information covering device initialization, register definition, command descriptions and device operation.
Initialization
SDRAMs must be powered up and initialized in a predefined manner.
The 64M SDRAM is initialized after the power is applied to VCC and VCCQ (simultaneously) and the clock is stable.
A 100µs delay is required prior to issuing any command other than a COMMAND INHIBIT or a NOP. The COMMAND INHIBIT or NOP may be applied during the 100us period and continue should at least through the end of the period.
With at least one COMMAND INHIBIT or NOP command having been applied, a PRECHARGE command should be applied once the 100µs delay has been satisfied. All banks must be precharged. This will leave all banks in an idle idle state where two AUTO REFRESH cycles must be performed. After the AUTO REFRESH cycles are complete, the SRDRAM is then ready for mode register programming.
The mode register should be loaded prior to applying any operational command because it will power up in an unknown state.
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
15 |
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
REGISTER DEFINITION
Mode Register
The mode register is used to define the specific mode of operation of the SDRAM. This definition includes the selection of a burst length, a burst type, a CAS\ latency, an operating mode and a write burst mode, as shown in MODE REGISTER DEFINITION.
The mode register is programmed via the LOAD MODE REGISTER command and will retain the stored information
MODE REGISTER DEFINITION
until it is programmed again or the device loses power.
Mode register bits M0-M2 specify the burst length, M3 specifies the type of burst (sequential or interleaved), M4M6 specify the CAS latency, M7 and M8 specify the operating mode, M9 specifies the WRITE burst mode, and M10 and M11 are reserved for future use.
The mode register must be loaded when all banks are idle, and the controller must wait the specified time before initiating the subsequent operation. Violating either of these requirements will result in unspecified operation.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A11 A10 |
A9 A8 |
|
|
A7 A6 |
A5 |
|
A4 A3 |
|
|
|
A2 |
A1 |
A0 |
Address Bus |
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Mode Register (Mx) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
Reserved(1) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burst Length |
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M2 |
M1 |
M0 |
M3=0 |
M3=1 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
0 |
0 |
|
1 |
1 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
0 |
1 |
|
2 |
2 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
1 |
0 |
|
4 |
4 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
1 |
1 |
|
8 |
8 |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
0 |
0 |
|
Reserved |
Reserved |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
0 |
1 |
|
Reserved |
Reserved |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
1 |
0 |
|
Reserved |
Reserved |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
1 |
1 |
|
Full Page |
Reserved |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burst Type |
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M3 |
|
|
|
|
Type |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
Sequential |
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
|
|
|
Interleaved |
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Latency Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M6 |
M5 |
M4 |
|
|
CAS Latency |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
0 |
0 |
|
0 |
|
|
|
Reserved |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
0 |
0 |
|
1 |
|
|
|
Reserved |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
0 |
1 |
|
0 |
|
|
|
|
|
2 |
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
0 |
1 |
|
1 |
|
|
|
|
|
3 |
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
1 |
0 |
|
0 |
|
|
|
Reserved |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
1 |
0 |
|
1 |
|
|
|
Reserved |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
1 |
1 |
|
0 |
|
|
|
Reserved |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
1 |
1 |
|
1 |
|
|
|
Reserved |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
Operating Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
M8 M7 |
M6-M0 |
Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
0 |
0 |
Defined |
Standard Operation |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
— |
— |
|
— |
All Other States Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
Write Burst Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M9 |
|
Mode |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
0 |
|
|
Programmed Burst Length |
|
|
|
|
|
|
|
|
|
1. To ensure compatibility with future devices, |
|
|||||||||||||||||||
|
1 |
|
|
Single Location Access |
|
|
|
|
|
|
|
|
|
|
|
|
|
should program M11, M10 = "0, 0" |
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16 Integrated Silicon Solution, Inc. — 1-800-379-4774
TARGET SPECIFICATION Rev. C
05/04/01
IS42S16400 |
ISSI® |
Burst Length
Read and write accesses to the SDRAM are burst oriented, with the burst length being programmable, as shown in MODE REGISTER DEFINITION. The burst length determines the maximum number of column locations that can be accessed for a given READ or WRITE command. Burst lengths of 1, 2, 4 or 8 locations are available for both the sequential and the interleaved burst types, and a full-page burst is available for the sequential type. The full-page burst is used in conjunction with the BURST TERMINATE command to generate arbitrary burst lengths.
Reserved states should not be used, as unknown operation or incompatibility with future versions may result.
When a READ or WRITE command is issued, a block of columns equal to the burst length is effectively selected.
All accesses for that burst take place within this block, meaning that the burst will wrap within the block if a boundary is reached. The block is uniquely selected by A1-A7 (x16) when the burst length is set to two; by A2-A7 (x16) when the burst length is set to four; and by A3-A7 (x16) when the burst length is set to eight. The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. Full-page bursts wrap within the page if the boundary is reached.
Burst Type
Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the burst type and is selected via bit M3.
The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column address, as shown in BURST DEFINITION table.
BURST DEFINITION
Burst |
Starting Column |
Order of Accesses Within a Burst |
|||
Length |
|
Address |
|
Type = Sequential |
Type = Interleaved |
|
|
|
|
|
|
|
|
|
A0 |
|
|
|
|
|
|
|
|
2 |
|
|
0 |
0-1 |
0-1 |
|
|
|
|
|
|
|
|
|
1 |
1-0 |
1-0 |
|
|
|
|
|
|
|
|
A1 |
A0 |
|
|
|
|
|
|
|
|
|
|
0 |
0 |
0-1-2-3 |
0-1-2-3 |
|
|
|
|
|
|
4 |
|
0 |
1 |
1-2-3-0 |
1-0-3-2 |
|
|
|
|
|
|
|
|
1 |
0 |
2-3-0-1 |
2-3-0-1 |
|
|
|
|
|
|
|
|
1 |
1 |
3-0-1-2 |
3-2-1-0 |
|
|
|
|
|
|
|
A2 |
A1 |
A0 |
|
|
|
|
|
|
|
|
|
0 |
0 |
0 |
0-1-2-3-4-5-6-7 |
0-1-2-3-4-5-6-7 |
|
|
|
|
|
|
|
0 |
0 |
1 |
1-2-3-4-5-6-7-0 |
1-0-3-2-5-4-7-6 |
|
|
|
|
|
|
|
0 |
1 |
0 |
2-3-4-5-6-7-0-1 |
2-3-0-1-6-7-4-5 |
|
|
|
|
|
|
8 |
0 |
1 |
1 |
3-4-5-6-7-0-1-2 |
3-2-1-0-7-6-5-4 |
|
|
|
|
|
|
|
1 |
0 |
0 |
4-5-6-7-0-1-2-3 |
4-5-6-7-0-1-2-3 |
|
|
|
|
|
|
|
1 |
0 |
1 |
5-6-7-0-1-2-3-4 |
5-4-7-6-1-0-3-2 |
|
|
|
|
|
|
|
1 |
1 |
0 |
6-7-0-1-2-3-4-5 |
6-7-4-5-2-3-0-1 |
|
|
|
|
|
|
|
1 |
1 |
1 |
7-0-1-2-3-4-5-6 |
7-6-5-4-3-2-1-0 |
|
|
|
|
|
|
Full |
n = A0-A7 |
|
Cn, Cn + 1, Cn + 2 |
Not Supported |
|
Page |
|
|
|
Cn + 3, Cn + 4... |
|
(y) |
(location 0-y) |
|
…Cn - 1, |
|
|
|
|
|
|
Cn… |
|
|
|
||||
|
|
|
|
|
|
Integrated Silicon Solution, Inc. — 1-800-379-4774 |
17 |
||||
TARGET SPECIFICATION |
Rev. C |
|
|
|
|
05/04/01 |
|
|
|
|
|