International Power Sources ZCA6C01PAPDI, ZCA6C01PAPDL, ZCA6C01PAPDM, ZCA6C16M, ZCA6C17I Datasheet

...
0 (0)

ZC6.qxd 6/6/03 4:03 pm Page 1

Configurable Power Supply

 

 

 

 

600 Watts

XPiQ inc.

ZC Series

Intelligent Design Quality Product

 

 

 

 

 

 

Meets EN61000-3-2, -3

 

 

 

 

Up to 5 Outputs Plus 5V Standby

 

 

 

 

 

 

Low Voltage Outputs Down to 1.8V

 

 

 

 

 

 

Hot Swap or Chassis Mount

 

 

 

 

 

 

Oring Diodes On All Outputs

 

 

 

(Hot Swap Modules)

 

 

 

 

 

 

1U, 19” Rack Mount for 2 units

 

 

 

 

 

 

International Safety Approvals with CE (LVD)

 

 

 

 

 

Specification

Input

AC Input Voltage

85-264 VAC

Input Frequency

47-63 Hz

DC Input Voltage

• 48 VDC nominal (optional)

Power Factor

0.99

Harmonic Current

Meets EN61000-3-2

Inrush Current

• Limited to 30A peak

Input Protection

Internal 15A fuse

Output

Output Voltage

• 1.8 VDC to 12 VDC

Output Power

600W

Output Voltage Adj

• ±5% min, See models chart

Minimum Load

• 0 minimum load for all outputs

Line/Load Regulation

• ±2% for V1, V2 and V3, ±3%

 

 

for V4 and V5

Ripple & Noise

• >2.5V output: 50mV or 1% whichever

 

 

is greater <=2.5V output:

 

 

2% maximum

Transient Response

• 4% max deviation, 300 µs recovery

 

 

time for a 25% load change

Temperature Co-eff.

0.02%/°C

Hold Up Time

20ms minimum

Remote Sense

• Up to 0.25 V compensation on V1, V2

 

 

and V3

Overvoltage

• V1, V2 and V3 only, recycle

Protection

 

input to reset

Overcurrent

• Standard with auto recovery

Protection

 

 

Overtemperature

• Logic high signal for overtemp

Protection

 

conditions

Current Sharing

• ±10% for V1, V2 and V3 with

 

 

“H” option

General

Efficiency

• 75% typical at full load

Power Density

6.8 W/in3

MTBF

• 200,000 hrs per Bellcore

Isolation Voltage

• 3000 VAC Input to Output

 

 

1500 VAC Input to Ground

 

 

500 VAC Output to Ground

Signals

• PSU Enable, AC Fail, DC OK,

 

 

Global Inhibit, overtemp

LED Indicators

2 status indicators

Size

• 5.0” x 11.0” x 1.6”.

Weight

• 3.3 lbs (1.5 kgs.)

Environmental

Operating

0°C to 70°C, Full power to 50°C

Temperature

 

derate from 50°C to 70°C

 

 

at 2.5%/°C

Cooling

3 Internal ball bearing fans

Humidity

<95% RH, non-condensing

Storage Temperature

-40°C to +85°C

Safety and EMC

Safety Approvals

• UL1950, CSA C22.2 No 950 per cUL,

 

EN60950 CE Mark LVD

EMI/EMC

• EN61000-3-2, -3, EN55022 and FCC

 

20780 part 15J Class B conducted

 

with rack, Class A stand alone

Immunity & Surge

• Meets EN61000-4-4, -5

 

PH: 508

429.9883

 

 

 

 

 

 

FAX: 800

226.2100

 

 

www.XPiQ.com

 

 

Email: sales@xpiq.com

 

 

 

 

Holliston, MA 01746 USA

 

 

 

 

 

International Power Sources ZCA6C01PAPDI, ZCA6C01PAPDL, ZCA6C01PAPDM, ZCA6C16M, ZCA6C17I Datasheet

ZC6.qxd 6/6/03 4:03 pm Page 2

 

 

ORDERING CODES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZC

 

 

CODE

V1

 

V2

 

 

V3

 

CODE

 

 

 

V4

 

CODE

 

V5

 

 

01

 

1.8 V @ 70 A

 

2.5 V @ 50 A

 

12

V @ 10A

 

 

PA

 

+3.3 V @ 3 A

 

PD

 

+1.8 V @ 3 A

 

 

02

 

1.8 V @ 70 A

 

3.3 V @ 50 A

 

12

V @ 10A

 

 

NA

 

 

-3.3 V @ 3 A

 

ND

 

-1.8 V @ 3 A

 

 

03

 

1.8 V @ 70 A

 

5.0 V @ 50 A

 

12

V @ 10A

 

 

PB

 

+5.0 V @ 3 A

 

PE

 

+2.5 V @ 3 A

 

 

04

 

2.5 V @ 100 A

 

-

 

 

12

V @ 10A

 

 

NB

 

 

-5.0 V @ 3 A

 

NE

 

-2.5 V @ 3 A

 

 

05

 

2.5 V @ 70 A

 

3.3 V @ 50 A

 

12

V @ 10A

 

 

 

 

PC

 

+12.0 V @ 3 A

 

PF

 

+3.3 V @ 3 A

 

 

06

 

2.5 V @ 70 A

 

5.0 V @ 50 A

 

12

V @ 10A

 

 

 

 

 

NC

 

-12.0 V @ 3 A

 

NF

 

-3.3 V @ 3 A

 

 

07

 

3.3 V @ 100 A

 

-

 

 

12

V @ 10A

 

-

 

 

-

 

PG

 

+5.0 V @ 3 A

 

 

08

 

3.3 V @ 70 A

 

2.5 V @ 50 A

 

12

V @ 10A

 

 

 

-

 

 

-

 

NG

 

-5.0 V @ 3 A

 

 

09

 

3.3 V @ 70 A

 

5.0 V @ 50 A

 

12

V @ 10A

 

 

 

-

 

 

-

 

PH

 

+5.2 V @ 3 A

 

 

10

 

5.0 V @ 100 A

 

-

 

 

12

V @ 10A

 

-

 

 

-

 

NH

 

-5.2 V @ 3 A

 

 

11

 

5.0 V @ 70 A

 

2.5 V @ 50 A

 

12

V @ 10A

 

-

 

 

-

 

-

 

-

 

 

12

 

5.0 V @ 70 A

 

3.3 V @ 50 A

 

12

V @ 10A

 

-

 

 

-

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

1.8 V @ 70 A

 

2.5 V @ 50 A

 

5

V @ 10A

 

 

XX

 

 

 

N/C

 

PD

 

+1.8 V @ 3 A

 

 

14

 

1.8 V @ 70 A

 

3.3 V @ 50 A

 

5

V @ 10A

 

 

-

 

 

-

 

ND

 

-1.8 V @ 3 A

 

 

15

 

2.5 V @ 100 A

 

 

 

 

5

V @ 10A

 

-

 

 

-

 

-

 

-

 

 

16

 

2.5 V @ 50 A

 

3.3 V @ 50 A

 

5

V @ 10A

 

-

 

 

-

 

-

 

-

 

 

17

 

3.3 V @ 100 A

 

 

 

 

5

V @ 10A

 

-

 

 

-

 

-

 

-

 

 

18

 

2.5 V @ 50 A

 

2.5 V @ 50 A

 

5

V @ 10A

 

-

 

 

-

 

-

 

-

 

Notes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. For module codes 13 to 18, V4 may have an unregulated output but this output is not useable. XX is the only option code available for

 

 

V4 and only ±1.8V output is available for V5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. V4 is user adjustable from 2.8 VDC to 14.75 VDC codes define setpoint at factory.

 

 

 

 

 

 

 

3. V5 is user adjustable from 1.7 VDC to 8.12 VDC codes define setpoint at factory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PART NUMBER ORDERING SCHEME

 

 

 

 

 

 

 

 

 

 

 

 

Series

 

AC or DC

 

Hotswap or

 

V1-V3

 

Polarity

 

V4 Output

 

Polarity of

V5 Output

 

Option

 

 

 

 

Input

 

 

Chassis

 

Code

 

of V4

 

Code

 

 

V5

Code

 

Code

 

 

ZC

 

A6=AC

 

H=Hotswap

 

01 to 18

 

P = Positive

 

A to C

 

 

P = Positive

D to H

L = Low Leakage

 

 

 

 

D6=DC

 

C=Chassis

 

 

 

 

N = Negative

 

 

 

N = Negative

 

 

I = I2C Module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M = Low Leakage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

&12C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: ZCA6H06NCNG is AC input, Hotswap chassis with V1 = 2.5V/70A, V2 = 5V/50A, V3 = 12V/10A, V4 = -12V/3A, V5 = -5V/3A.

Mechanical Details

* Note:

Vertical blackplane mounting may not allow for sufficient airflow. Horizontal backplane, or additional spacing with a vertical backplane is recommended.

www.XPiQ.com

PH: 508 429.9883

FAX: 800 226.2100 Email: sales@xpiq.com Holliston, MA 01746 USA