THF.qxd 25/6/03 2:28 pm Page 1
AC/DC Din Rail Mount
|
|
|
|
45-240 Watts |
XPiQ inc. |
||
THF Series |
Intelligent Design Quality Product |
||
|
|
||
|
|
|
|
• |
Wide Adjustment Range |
|
|
|
|
• |
|
|
|
Rugged For Industrial Use |
|
|
|
• |
|
|
|
High Efficiency |
|
|
|
• |
|
|
|
Overvoltage Protection |
|
|
|
• |
|
|
|
Overcurrent Protection |
|
|
|
• |
|
|
|
Overtemperature Protection |
|
|
|
• |
|
|
|
Lightweight Design |
|
|
|
|
|
Specification
Input
Input Voltage |
• |
85-264 VAC |
|
|
(120 W model 88-132 VAC/176-264 |
|
|
VAC switch selectable) |
Input Frequency |
• |
47-63 Hz |
Inrush Current |
• |
60 A max |
Input Current |
• 115 VAC - 3.5 A max |
|
|
|
230 VAC - 1.8 A max |
Earth Leakage |
• <1.0 mA at 240 VAC max (45-75 W) |
<3.5 mA at 240 VAC max (120-240 W)
General
Efficiency |
• |
72%-85% (depending on model) |
Isolation |
• |
Input-Output 3000 VAC |
|
|
Input-Earth 1500 VAC |
|
|
Output-Earth 500 VAC |
Environmental
Operating |
• |
See Derating Curves |
Temperature |
|
|
Storage |
• |
-20 °C to +85 °C |
Temperature |
|
|
Output |
|
|
Relative Humidity |
• |
90% RH max |
|
Output Voltage |
• |
See Tables |
Weight |
• |
1.1 kg max |
|
Output Voltage Tol |
• |
±2% max |
EMC & Safety |
|
|
|
Output Voltage |
• |
±10% |
|
|
||
Adjustment |
|
|
EMC |
• EN55022 ‘B’, EN6000-4-2, 3, 4, |
||
Line Regulation |
• |
±1% max |
|
|
5, 6, 8, 11 ENV50204, EN61000-3-2, -3 |
|
Load Regulation |
• |
±1% max |
|
|
EN50082-2 |
|
Safety |
• TUV EN60950, UL508 approved |
|||||
Ripple & Noise |
• |
See Table |
||||
|
|
|
||||
Overload |
• |
105-150% constant current |
|
|
|
|
Protection |
|
|
|
|
|
|
Overvoltage |
• |
125% typical |
|
|
|
|
Protection |
|
|
|
|
|
|
Temperature |
• |
±0.03%/°C |
|
|
|
|
Coefficient |
|
|
|
|
|
• |
|
PH: 508 |
429.9883 |
• |
||
|
||||||
|
||||||
|
|
|
|
FAX: 800 |
226.2100 |
|
|
www.XPiQ.com |
|
|
Email: sales@xpiq.com |
|
|
|
|
|