85-264 VAC
47-63 Hz
• 90 µA max at 115 VAC 60 Hz 150 µA max at 230 VAC 50 Hz
• 10 A max at 115 VAC, 25 A max at 230 VAC
• 0.7 A (rms) at 115 VAC, 0.4 A (rms) at 230 VAC

AC/DC Medical Open Frame

 

 

 

 

 

25 Watts

 

 

XPiQ inc.

PBM25 Series

 

 

Intelligent Design Quality Product

 

 

 

 

 

 

 

 

 

 

Small Size 2.50” x 4.25” x 0.96”

 

 

 

 

 

 

 

 

 

 

Low Leakage Current

 

 

 

 

 

 

 

 

Medical Safety Agency Approvals

 

 

 

 

 

 

 

 

Both Line and Neutral Fused

 

 

 

 

 

 

 

 

Meets Class B, EN55011 Conducted

 

 

 

 

 

 

 

 

Fixed Switching Frequency

 

 

 

 

 

 

Specification

Input

Input Voltage

Input Frequency

Earth

Leakage Current

Inrush Current

Input Current

General

Efficiency

• 70% minimum Vo>=12 V,

 

68% minimum all others

Isolation Voltage

• 4000

VAC Input to Output

 

1500

VAC Input to Ground

 

500 VAC Output to Ground

MTBF

• 500,000 hrs per min MIL-HDBK-217F

Switching Frequency

• 42 KHz ±5 KHz

Size

• 2.50” x 4.25” x 0.96”

 

 

 

Weight

Single output models 163 g,

Output

 

 

 

 

Multi output models: 175 g

 

 

Environmental

 

Output Voltage

5.1 to 28 VDC, See Table

 

Output Power

25/28 Watts, See Table

Operating

0 °C to +70 °C,

Minimum Load

• No minimum for single outputs models

Temperature

 

derate linearly from 100% load at

 

 

+50°C to 50% load at +70 °C

 

 

See Table for multi outputs models

 

 

 

 

Storage

-40 °C to +85 °C

Line Regulation

• ±0.5% max at full load

Temperature

 

 

Total Regulation

See Table

 

 

Cooling

Convection cooled

Ripple & Noise

• ±1% max pk-pk (See Note 2)

Relative Humidity

5-95%, non-condensing

Transient Response

• 4% max deviation, 500 µs recovery

 

 

 

 

 

time for a 25% load change

EMC & Safety

 

 

Temperature

±0.04%/°C

 

 

Safety Approvals

UL2601-1, CSA C22.2 No 601.1,

Coefficient

 

 

 

 

 

 

EN60601-1, IEC 601-1

Hold up Time

• 10 ms minimum at 110 VAC

 

 

EMI/EMC

EN55011 (CISPR11) Class B & FCC

Overvoltage

• Provided on output 1 only; set at

 

 

Class B conducted

Protection

 

112-132% of its nominal output

 

 

 

 

 

 

 

 

voltage

 

 

 

Overcurrent

• All outputs protected to short

 

 

 

Protection

 

circuit conditions Auto restart

 

 

 

 