Invacare POC1–100B-C, POC1–100B-AZ, POC1–100B, POC1–100B-EU Service Manual

Invacare®Platinum®Mobile
POC1–100B,POC1–100B-EU,POC1–100B-AZ, POC1–100B-C
enOxygenConcentrator
ServiceManual
DEALER:Keepthismanual. TheproceduresinthismanualMUSTbeperformedbyaqualied technician.
©2017InvacareCorporation Allrightsreserved.Republication,duplicationormodicationinwholeorinpartisprohibited withoutpriorwrittenpermissionfromInvacare.Trademarksareidentiedby™and®.Alltrademarks areownedbyorlicensedtoInvacareCorporationoritssubsidiariesunlessotherwisenoted. PlatinumisaregisteredtrademarkintheU.S.A.,EuropeandAustralia. MakingLife’sExperiencesPossibleisaregisteredtrademarkintheU.S.A. Pine-sol,LestoilandCloroxareregisteredtrademarksofTheCloroxCompany. DawnisaregisteredtrademarkofTheProcterandGambleCompany .
Contents
1General.........................................4
1.1Symbols.....................................4
1.2Features.....................................6
1.2.1ControlPanel...............................6
1.2.2Input/OutputConnections.....................7
1.2.3Filters....................................8
1.2.4GeneralInformation..........................8
2Safety..........................................9
2.1GeneralGuidelines.............................9
2.2RadioFrequencyInterference.....................12
3Setup...........................................13
3.1ViewingtheDateandTime.......................13
3.2ChangingtheDateandTime......................13
3.3ChangingtheLanguage..........................15
4Service..........................................18
4.1ServicingGuidelines............................18
4.2ServiceandReplacementParts....................18
4.3ServiceLife...................................18
4.4ReplacingPatientOutletFilter.....................18
4.5ReplacingDCPowerCableFuse....................19
4.6ReplacingtheBatteryPullRing....................20
5Troubleshooting...................................22
5.1AlarmCodes..................................22
5.1.1ViewingtheCurrentAlarmCodeandSoftware
VersionNumber............................22
5.1.2ViewingtheAlarmCodeHistory.................23
5.1.3AlarmCodes...............................23
6Maintenance.....................................42
6.1WearandT ear................................42
6.2ViewingHourMeter............................42
6.3CleaningtheAirIntakeFilterScreen................42
6.4CleaningandDisinfectionBetweenPatients...........43
6.5PreventativeMaintenanceChecklist.................44
6.6CheckingO2Purity.............................46
6.7FunctionT est.................................47
7AfterUse........................................48
7.1Disposal.....................................48
Invacare®Platinum®Mobile
1General
1.1Symbols
Signalwordsareusedinthismanualandapplytohazards orunsafepracticeswhichcouldresultinpersonalinjury orpropertydamage.Refertotheinformationbelowfor denitionsofthesignalwords.
DANGER!
–Dangerindicatesanimminentlyhazardous
situationwhich,ifnotavoided,willresultin deathorseriousinjury .
WARNING!
–Warningindicatesapotentiallyhazardous
situationwhich,ifnotavoided,couldresultin deathorseriousinjury .
CAUTION!
–Cautionindicatesapotentiallyhazardous
situationwhich,ifnotavoided,mayresultin propertydamageorminorinjuryorboth.
IMPORTANT!
–Importantindicatesahazardoussituationthat
couldresultindamagetopropertyifitisnot avoided.
Givesusefultips,recommendationsandinformation forefcient,trouble-freeuse.
Refertothefollowingtableforthemeaningofsymbols markedontheequipmentand/orpackaging.
GeneralWarningSign
Thebackgroundcolorinsidethe triangleisyellowonproductlabels.
FollowInstructionsforUse
Thecolorofthesymbolbackgroundis blueonproductlabels.
Noopename
Thecolorofthecirclewithdiagonal barisredonproductlabels.
DONOTSmoke
Thecolorofthecirclewithdiagonal barisredonproductlabels.
ConsultInstructionsforUse
Thissymbolislocatedonthecannula packing.
DirectCurrent
TypeBFAppliedPart
4
1187375-B
General
ClassIIEquipment
PowerOn/Off
DataOutputT erminal
DONOTdisposeofinhouseholdwaste
EuropeanCommunityAuthorized Representative
Manufacturer
DateofManufacture
Recycle
ReferenceNumber
SerialNumber
DONOTReuse(SinglePatientUseOnly)
Thissymbolreferstothecannula whichisforsinglepatientuseonly.
LatexFree
IndoorUseONLY
ThissymbolisincludedontheAC poweradapter .
DONOTuseoilorgrease
Keepdry
Protectedagainstsolidforeignobjectsof12.5 mmdiameterandgreater .
Protectedagainstverticallyfallingwaterdrops whenenclosuretiltedupto15°.
Protectedagainstsolidforeignobjectsof12.5 mmdiameterandgreater .
Protectedagainstverticallyfallingwaterdrops.
TransportandStorageTemperature
1187375-B5
Invacare®Platinum®Mobile
TransportandStorageHumidity
ThisproductcomplieswithDirective 93/42/EECconcerningmedicaldevices.
Thelaunchdateofthisproductisstatedin theCEdeclarationofconformity.
74103
ElectricalSafetyAgencyCerticationMark
1.2Features
1.2.1ControlPanel
A
On/OffButton
Pressforonesecondtoturnconcentratoronoroff.
B
FlowSelectionButton
Presstoadjustthepulsedoxygenowtoyour prescribedsetting.Theselectedowsettingis shownonthedisplayscreen.RefertoAdjustingthe PulseFlowSettinginUsageformoredetails.
C
DisplayBacklightButton
Pressoncetoilluminatethedisplayscreenfor5 seconds.
D
AudioOffButton
Presstomutetheaudiblesignal(beep)forboth alarmsandstatusindications.Theblueindicator lightnexttothebuttonilluminateswhenactivated. Audiooffcanbeactivatedduringorpriortoan alarmconditionoccurring.
E
DisplayScreen
Displaysinformationabouttheoperatingstatusof theconcentrator .
F
AlarmIndicator
Theyellowindicatorlightatthecenterofthe triangularsymbolilluminatestoindicateabnormal operatingconditions.RefertoAlarmConditionsin Troubleshootingformoredetails.
61187375-B
General
G
BatteryGauge
Indicatesthechargestatusofthebattery(s).Refer toReadingtheBatteryGaugeforInstalledand UninstalledBattery(s)inSetupformoredetails.
H
ExternalPowerIndicator
Theorangeindicatorlightnexttotheplugsymbol illuminateswhenanexternalpowersourceis connectedtotheconcentrator.
I
BatteryCompartmentDoor
Usedtoaccesstheremovablebattery(s).
Not
Shown
AudibleSignal(Beep)
Indicatesachangeinoperatingstatusor aconditionwhichrequirestheoperator’s attention.
1.2.2Input/OutputConnections
A
OxygenOutletPort
Usedtoconnectthenasalcannulatothe concentrator .
B
ExternalPowerInputConnector
Usedtoconnectanexternalpowersourcetothe concentrator .
C
USBPort
Usedforserviceonly .
1187375-B
7
Invacare®Platinum®Mobile
1.2.3Filters
Airenterstheconcentratorthroughanairintakelter locatedonthecarrybag.Thislterpreventshairandother largeparticlesintheairfromenteringtheunit.Beforeyou operatetheconcentrator ,makesurethislteriscleanand dry,andtheconcentratorisproperlyinstalledinthecarry bag.
Tocleantheairintakelter ,refertoCleaningtheAirIntake FilterScreeninMaintenance.
Toensuretheconcentratorisproperlyinstalledinthecarry bag,refertoInstallingtheCarryBaginSetup.
1.2.4GeneralInformation
RefertotheUserManualforuserinformationandtechnical data.
81187375-B
Safety
2Safety
2.1GeneralGuidelines
Inordertoensurethesafeinstallation,assemblyand operationoftheconcentratortheseinstructionsMUSTbe followed.
DANGER! RiskOfDeath,InjuryOrDamage
Improperuseoftheproductmaycausedeath, injuryordamage.Thissectioncontainsimportant informationforthesafeoperationanduseofthis product.
–DONOTusethisproductoranyavailable
optionalequipmentwithoutrstcompletely readingandunderstandingtheseinstructions andanyadditionalinstructionalmaterialsuch asusermanuals,servicemanualsorinstruction sheetssuppliedwiththisproductoroptional equipment.
–Ifyouareunabletounderstandthewarnings,
cautionsorinstructions,contactahealthcare professional,dealerortechnicalpersonnel beforeattemptingtousethisequipment.
–THEINFORMA TIONINTHISDOCUMENTIS
SUBJECTTOCHANGEWITHOUTNOTICE.
DANGER! RiskofDeath,InjuryOrDamageFromFire
Textiles,oilorpetroleumsubstances,grease, greasysubstancesandothercombustiblesare easilyignitedandburnwithgreatintensityin oxygenenrichedairandwhenincontactwith oxygenunderpressure.Smokingduringoxygen therapyisdangerousandislikelytoresultin burnsordeath.T oavoidre,death,injuryor damage:
–DONOTSMOKEwhileusingthisdevice.DO
NOTusenearOPENFLAMEorIGNITION SOURCES.
–NOSMOKINGsignsshouldbeprominently
displayed.
–Keepallopenames,matches,lighted
cigarettes,electroniccigarettesorothersources ofignitionatleast10ft(3m)awayfromthis concentratororanyoxygencarryingaccessories suchascannulasortanks.
1187375-B9
Invacare®Platinum®Mobile
DANGER! RiskofDeath,InjuryOrDamageFromFire
Textiles,oilorpetroleumsubstances,grease, greasysubstancesandothercombustiblesare easilyignitedandburnwithgreatintensityin oxygenenrichedairandwhenincontactwith oxygenunderpressure.Toavoidre,death, injuryordamage:
–Avoidcreationofanysparknearoxygen
equipment.Thisincludessparksfromstatic electricitycreatedbyanytypeoffriction.
–Useonlyoxygencompatiblewater-based
lotionsorsalvesbeforeandduringservicing. Toverify ,refertothelotion/salvecontainer foroxygencompatiblewater-basedstatement. Ifnecessary,contactthemanufacturer .DO NOTuseanylubricantsonconcentratorunless recommendedbyInvacare.
–Keeptheoxygentubing,cord,ACadapterand
concentratorawayfromheatedorhotsurfaces includingspaceheaters,stoves,andsimilar electricalappliances.
–Makesureconcentratorisoffwhennotinuse.
WARNING! RiskOfInjuryOrDamage
–Invacareproductsarespecicallydesigned
andmanufacturedforuseinconjunction withInvacareprovidedorInvacarespecied accessories.Anyotheraccessorieshave notbeentestedbyInvacareandarenot recommendedforusewithInvacareproducts.
–Nomodicationofthisequipmentisallowed.
WARNING! RiskofInjuryorDamage
Toavoidinjuryordamagewhichwillvoid warranty:
–UseonlyInvacarespeciedpowersupplies.
DANGER! RiskofDeath,Injury,fromElectricShock
Toreducetheriskofburns,electrocution,death orinjurytopersons:
–DONOTcomeincontactwiththeconcentrator
whilewet.
–DONOTplaceorstoreconcentratorwhereit
candropintowaterorotherliquid.
–DONOTreachforconcentratorthathasfallen
intowater .UnplugIMMEDIATELY .
–DONOTblockaccesstopoweroutletneeded
tounplugtheACpowercord. –DONOTusefrayedordamagedpowercords. –DONOTuseACpoweradapterifitshousingis
crackedorseparated.
101187375-B
Safety
WARNING! RiskofDeath,InjuryorDamage
Topreventinjuryordamagefromcordmisuse:
–DONOTmoveorrelocateconcentratorby
pullingonthecord.
–DONOTuseextensioncordswithACpower
adaptersprovided.
–Properlystoreandpositionelectricalcords
and/ortubingtopreventatrippingand strangulationhazards.
WARNING! RiskofInjuryorDamage
Asasafetyfeature,thisappliancemayhavea polarizedplug(onebladeiswiderthantheother). Toavoidinjuryordamagefromelectricalshock:
–Thisplugwilltinapolarizedoutletonlyone
way.Iftheplugdoesnottfullyintheoutlet, reversetheplug.Ifitstilldoesnott,contact
aqualiedelectrician. –DONOTalterthepluginanyway . –DONOTuseifthecordorplugaredamaged.
Callaqualiedelectricianforrepair .
WARNING! RiskofInjuryorDamage
Topreventdamagefromliquidingress:
–NEVERdroporinsertanyobjectorliquidinto
anyopening. –DONOTuseifcabinetofconcentratoror
housingofACpoweradapteriscrackedor
separated.
WARNING! RiskofInjuryorDamage
Toavoidinjuryordamagefromairborne pollutantsand/orfumesandforoptimal performance:
–Locateandpositiontheconcentratorinawell
ventilatedspacesothattheairintakeandthe airexhaustopeningsarenotobstructed.
–NEVERblocktheairopeningsofthe
concentratororplaceitonasoftsurface,such asabedorcouch,wheretheairopeningmay beblocked.
–Keeptheopeningsfreefromlint,hairand
similarforeignitems.
–Keepconcentratoratleast12in(30.5cm)away
fromwalls,draperiesandfurniture.
–DONOTuseinpresenceofpollutants,smoke
orfumes,ammableanesthetics,cleaning agentsorchemicalvapors.
1187375-B
11
Invacare®Platinum®Mobile
2.2RadioFrequencyInterference
MedicalElectricalEquipmentneedstobeinstalledandused accordingtotheEMCinformationinthismanual.
Thisequipmenthasbeentestedandfoundtocomplywith EMClimitsspeciedbyIEC/EN60601-1-2.Theselimits aredesignedtoprovideareasonableprotectionagainst electromagneticinterferenceinatypicalhomehealthcare environment.
PortableandmobileRFcommunicationsequipmentcan affecttheoperationofthisequipment.Useofthis equipmentadjacenttoorstackedwithotherequipment shouldbeavoidedasitcouldresultinimproperoperation. Theconcentratoroperationshouldbeobservedtoverify normaloperationinthepresenceofsuchequipment.
Otherdevicesmayexperienceinterferencefromeven thelowlevelsofelectromagneticemissionspermittedby theabovestandards.T odetermineiftheemissionsfrom theconcentratorarecausingtheinterference,turnthe concentratoroff .Iftheinterferencewiththeotherdevice(s) stops,thentheconcentratoriscausingtheinterference.In suchrarecases,interferencemaybereducedorcorrected byoneofthefollowingmeasures:
Reposition,relocate,orincreasetheseparationbetween theequipment.
Connecttheequipmentintoanoutletonacircuit differentfromthattowhichtheotherdevice(s)is connected.
RefertoElectromagneticCompliance(EMC)inTechnical Dataforadditionalinformation.
12
1187375-B
Setup
3Setup
3.1ViewingtheDateandTime
Thisproceduredisplaysthedateandtime.
TheconcentratormustbeOffandconnectedto externalpowertoperformthisprocedure.
SampleDateandTimeDisplayScreen
1.Ensureunitisoffandconnectedtoanexternalpower source.
2.PressandholdthedisplaybacklightbuttonC.
After5secondsthedateandtimeareshownon thedisplayscreenB.
3.Pressthedisplaybacklightbuttontocancelviewingthe dateandtime.
3.2ChangingtheDateandTime
Thisproceduredescribestheprocesstochangethe dateandtime.
TheconcentratormustbeOffandconnectedto externalpowertoperformthisprocedure.
Thetimeisdisplayedtothenearestsecond.The timeissettothenearestminute.
Theformatofthedateandtimearedependent ontheselecteddisplaylanguage.ForEnglish,the dateismm/dd/yyyyandtimeishh:mm:ssAM/PM. ForlanguagesotherthanEnglish,thedateis dd/mm/yyyyandtimeishh:mm:ss,wherehh=24 hour.
SampleDateandTimeDisplayScreens
FormatforEnglishFormatforOtherLanguages
ExceptEnglish
1187375-B13
Invacare®Platinum®Mobile
1.Ensureunitisoffandconnectedtoanexternalpower source.
2.PressandholdthedisplaybacklightbuttonC.
After5secondsthedateandtimeareshownon thedisplayscreenB.
3.Whilethedateandtimeareshownonthedisplay screen,pressandreleasethepowerbuttonA.
Pressingthepowerbuttonactivatesthedate andtimechangemode. Theselecteditemishighlighted.
4.PresstheowselectionbuttonDtoincreasethe selectedvaluebyoneuntilthemaximumisreachedand thenrollsovertothelowestvalue.
5.Pressthedisplaybacklightbuttontodecreasethe selectedvaluebyoneuntiltheminimumisreachedand thenrollsovertothehighestvalue.
6.Pressthepowerbuttontohighlightthenextitem.
7.Presstheaudiooff(mute)buttonEtohighlightthe previousitem.
14
1187375-B
Setup
8.Whenthetimeanddatehavebeenadjustedasdesired, pressthepowerbuttontohighlightSet.
9.Presstheowselectionbuttontosavethedateand timeandtoexitthetimeanddatescreen.
10.HighlightCancelandpresstheowselectionbuttonto cancelsettingthetimeanddateandtoexitthetime anddatescreen.
3.3ChangingtheLanguage
Thisproceduredescribestheprocesstochangethe displaylanguage.
Changingthedisplaylanguagemayalsochangethe dateandtimeformat.RefertoChangingtheDate andTimeformoreinformation.
TheconcentratormustbeOffandconnectedto externalpowertoperformthisprocedure.
Thefollowinglanguagesareavailableforselection:English, Danish,German,Finnish,French,Norwegian,Swedish, Spanish,Italian,Dutch,Polish,Latvian,Hungarian,Croatian andPortuguese.
1187375-B15
Invacare®Platinum®Mobile
1.Ensureunitisoffandconnectedtoanexternalpower source.
2.Simultaneouslypressandholdthedisplaybacklight buttonCandaudiooff(mute)buttonEforatleast vesecondstoentertheCurrentLanguageScreen.
TheCurrentLanguageScreenwillcontinueto displayuntilthebacklightbuttonispressed againtoexitthisscreen.
3.PressandreleasetheOn/OffbuttonAtoenterthe LanguageChangeScreen.
Theproposedlanguageselectionishighlighted.
4.PresstheowselectionbuttonDtomovetothenext languageselection.PressthedisplaybacklightbuttonC tomovetothepreviouslanguageselection.
5.Whenthedesiredlanguagehasbeenselected,pressthe On/Offpowerbuttontohighlight“SET” .
161187375-B
Loading...